Universal isolated USB to serial converter and RS232 to RS485/422 converter.

Similar documents
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

USB to RS-422/485 Serial Adapter

TX2123 RS485 TO ETHERNET ADAPTOR

Bluetooth to Serial Adapter

LBNP RS-232/485/422 serial device server. User manual

MS830 / MS833 Barcode Reader v1.0 9-December-2014

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Connecting the Console Port to a PC

Application/Connection Examples

Advanced Data Capture and Control Systems

User manual Compact Web PLC WP240 series IEC-line

1-Port R422/485 Serial PCIe Card

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

User Manual IC-485AI

Using HyperTerminal with Agilent General Purpose Instruments

1 Port RS232 Serial over IP Device Server

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

PCMCIA 1 Port RS EDITION OCTOBER 1999

User Guide Reflow Toaster Oven Controller

TX OPEN RS232/485 module

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

PM1122 INT DIGITAL INTERFACE REMOTE

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Technical description MX-1 VB Edge

Bluetooth HC-06 with serial port module Easy guide

Cable Pinouts. SRP I/O Module

s!nus-elektrotechnikai bt. Industrial IT & Automation

By4750. USB Serial Converter (RS232 RS485)

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

NPort DE-311 Hardware Installation Guide

IntesisBox Modbus Server Fidelio IP

1 Serial RS232 to Ethernet Adapter Installation Guide

RS-232/422/485, Power over Ethernet

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

SecureLinx Spider Duo Quick Start Guide

IP Link Device Interface Communication Sheet

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008

ATC-2000WF User s Manual

Bluetooth UART/RS232 Module

Moxa TCC-100/100I User s Guide

Warnings: This manual is intended to guide a technicians or customers who would like to repair DBL's

Telephone- and leased line modem for industrial applications TD-36

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

How to setup a serial Bluetooth adapter Master Guide

One Port Serial Server Users Manual Model ESP901, ESP901E

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Manual Serial PCI Cards

RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

OWNERS MANUAL. WattsVIEW. Power Monitor Model: DC WattsVIEWTM. Models: DC Serial DC-1000 USB DC-25000

Connecting instruments serially to your computer

1. SAFETY INFORMATION

2-Port RS232/422/485 Combo Serial PCI Card

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Connecting and Setting Up Your Laptop Computer

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Microprocessor Project Laboratory

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

Rack mounted telephone- and leased line modem for industrial applications

GSM Interfacing Board

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

s!nus-elektrotechnikai bt. Industrial IT & Automation

RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO

2/4/8 Port USB to Serial Adapter Hub with COM Retention

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Cabling Guide for Console and AUX Ports

CENTRONICS interface and Parallel Printer Port LPT

Keep it Simple Timing

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

VOICE RECORDING SYSTEM ISDN PRI / BRI

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Orbit PCI Mk 2 Network Card. User Manual. Part No Issue 4

Serial over Ethernet Device Server. User s Manual

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

Driver Pant 8 and antenna switcher Ant 8. User manual

Cable Specifications and Information

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Serial to Bluetooth Adapter

HARTING econ 3000 Introduction and features

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

4-CH Video Server SED-2310Q. Ver User s Manual

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

AUDITVIEW USER INSTRUCTIONS

Transcription:

GS180 Universal isolated USB to serial converter and RS232 to RS485/422 converter. Multifunctional unit, converts: USB RS232/485/422 or RS232 RS485/422 Powered via USB port or external power adaptor Compact unit, easily hand-held or wall/din rail mounted Application auto-detection! Simply wire up your GS180 to suit your needs, and let the unit configure itself! 1

Specifications Available sockets USB (B type) DB9 male (or female) 3-pin screw terminal 5-pin screw terminal USB 2.0 (5V DC) RS232 to RS485/422 RS232 RS485/422 Converts USB RS232/485/422 or RS232 RS485/422 Kit contains 1x GS180 1x USB type A to type B cable 1x 4-core RS232 cable + 2x DB9-female to RJ11 adaptors 1x Power adaptor (250V/5V 1A with USB connector) Supply voltage 5V DC. Powered via USB port or external power adaptor Current 130mA max Operating temperature 10 + 70 C Isolated data transmission RS485/422 isolation galvanic and RF coupling eliminates long term optocoupler drift. 2500V RMS 1 minute. Simplified configuration program, with 1-click conversion from RS232 RS485/422 Supports multiple baud rates USB RS232/485/422 300 230.4K baud RS232 RS485/422 300 115.2K baud Default settings for RS232 to RS422/485 conversion Baud: 9600, Parity: None, Data bits: 8, Stop bits: 1 Casing 25H x 70W x 108D (mm). IP rating 20. Mounting DIN rail 35mm. Requires GS180-DR bracket ( standard) Wall mount Requires GS180-WM wall bracket (optional) Accessories (Optional) Wall mount bracket (order code GS180-WM) 2

LED Indicators PWR lights up when power is supplied to the GS180 USB 5V DC port via your computer s USB port or the external power adaptor. USB lights up when a USB or power cable is connected to the GS180 USB 5V DC port, and there is no RS232 cable connected to the GS 18 0 RS232 DB9 port. This indicates that the GS180 converter is ready to convert from USB RS232/485/422. RS232 lights up when an RS232 cable is connected to the GS180 RS232 DB9 port. (Please note that the USB cable or external power adaptor must also be connected, as this supplies power to the unit.) RX lights up when the GS180 converter is receiving data from the RS232 Screw Terminal or RS485/422 ports. TX lights up when GS180 converter is transmitting data to the RS232 Screw Terminal or RS485/422 ports. 3

Port Pinouts USB Type B Socket Pin 1 + 5V Pin 2 Data Pin 3 Data + Pin 4 GND RS232 DB9 Socket Pin 1 No Connection Pin 2 Tx Pin 3 Rx Pin 4 No Connection Pin 5 GND Pin 6-9 No Connection RS232 3-pin Screw Terminal Pin 1 Rx Pin 2 Tx Pin 3 GND RS485/422 6-pin Screw Terminal RS422: Pin 1 T (Tx ) Pin 2 T + (Tx +) Pin 3 R (Rx ) Pin 4 R + (Rx +) Pin 5 GND Pin 6 No Connection RS485: Pin 1 D (Data ) Pin 2 D + (Data +) Pin 3-4 No Connection Pin 5 GND Pin 6 No Connection 4

Installing The Driver & GS180 Configurator Program Double click on the GS180.msi installer and follow the on-screen instructions. This will install the GS180 Configurator and driver. The GS180 Configurator program is used to change the default baud rate, bits or parity of the the GS180 converter to convert from RS232 RS485/422, and to install the driver/comport for the USB interface. Using the GS180 Configurator to Check the COM Port Number The GS180 Configurator can be used to check the COM port number after connecting the GS180 converter to your computer: Double click the GS180 Configurator icon on your computer s desktop to launch the program. If a GS180 converter is already connected to your computer, then the program will detect it automatically and display the COM port number as shown (right) If you have not yet connected a GS180 converter to your computer, then the program will display a message which reads No devices were discovered. 5

At this point you may connect a GS180 converter and then click Search again to find the COM port number. If you have more than one GS180 converter connected to your computer, then the program will find all of them and display their COM port numbers in a drop down list as shown (right). Converting from USB RS232/485/422 No configuration is necessary when using the GS180 to convert from USB RS232 or RS485/422. Once you have installed the driver and connected the GS180 to one of USB ports on your computer, you may start to use it immediately. The GS180 converter detects which cables are plugged in, so it is important to disconnect all cables that you are not using. 6

When converting from USB RS485/422, the RS232 serial cable must not be connected to the RS232 Screw Terminal, as this will prevent conversion to RS485/422. Please check the LED indicators before starting your transmission. If the USB LED is off but the RS232 LED is on, disconnect the RS232 cable from the RS232 DB9 port on the GS180 converter. Converting from RS232 RS485/422 You need to use the GS180 Configurator program to set the Baud rate on the GS180 converter to your desired value before starting any transmission. Once the Baud rate is set, it will be saved until you set it again. The factory default setting is 9600 Baud. Please note that the GS180 converter must be powered (via your computer s USB port or the external power adaptor) in order to convert from RS232 RS485/422. Double click the GS180 Configurator icon on your computer s desktop to launch the program. After the program is fired up, it will find the new COM port number, which is used to configure the GS180 converter. For more information on detecting your COM port number, see p5. 7

Choose your desired Baud rate from the Select Baud Rate drop down list, then click Set. A message will be shown at the bottom of the window to indicate whether the operation was successful or not. Once the Baud rate is set successfully, you can start your transmission. The GS180 converter may be shifted to any other computer or device which has standard USB ports, or it may be connected to the external power adaptor to convert between RS232 and RS485/422 at your desired Baud rate. To check the current Baud rate configuration, click Read Current Setting. A message will appear at the bottom of the window. When converting from RS232 RS485/422, the RS232 serial cable must not be connected to the RS232 RJ11 port, as this will just pass the data from RS232 to RS232. www.gedgesystems.com.au +61 (3) 9791 8944 27 Rhur Street, Dandenong South 3175, Australia Copyright 2012 Gedge Systems GS180-MAN-12V03 (0320)