CAGED ALUMINUM ACCESS LADDERS

Similar documents
SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

PART 1 GENERAL 1.1 SECTION INCLUDES

Chapter 3 Pre-Installation, Foundations and Piers

CLEAR-DIVISIONS CENTERFOLD

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SCOPE This guideline applies to all construction projects on Emory University properties, including renovation projects.

CLEAR-DIVISIONS APERTO

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

SECTION GUARDA SECURITY WINDOW SCREENS

CLEAR-DIVISIONS VARIOFOLD

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Wall braces with a swivel head are included to accommodate all roof pitches.

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION WINDOW WASHING SYSTEMS

The following symbol denotes a generally compliant condition: The following symbol denotes a generally noncompliant condition:

SECTION GROUND WATER STORAGE TANKS

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

PUBLIC RESTROOMS, DESIGN INTENT

TARIFF CODE and updates standard

SECTION 6. Glass Storefront Doors:

Introduction...COMB-2 Design Considerations and Examples...COMB-3

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Garden Windows Builders Vinyl

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Fixed and Portable Ladders- A Guide to OSHA Rules

SECTION PIPE HANGERS AND SUPPORTS

SECTION STANDING SEAM METAL ROOFING

Walking and Working Surface Checklist:

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Residential Deck Safety, Construction, and Repair

High Strain Dynamic Load Testing of Drilled Shafts

Fixed Vertical Access Ladders

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Mobile Home Pre-Inspection Checklist

RZ Guardrail System Installation Manual

CT-02 CABLE TRAY SYSTEMS

DESIGN CLARIFICATION (DC)

COMMONLY USED RESIDENTIAL BUILDING CODES

Simplified Steel Stair Design for Commercial and Institutional Buildings

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Phoenix-3W Series One-Way Security Revolving Doors

1.02 SYSTEM DESCRIPTION

James M. Pleasants Company

DENVER MODEL 30 X 30 SPECIFICATIONS

Preformed Metal Roofing and Siding

Chapter 10 - Scaffolding Systems

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

Steel Door Frame Installation in Steel Stud Construction

Residential Decks. Planning and Development Services Department

Horizontal Cable Systems

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Base Cabinet with Self-storing Folding Doors and Floor

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

SECTION CHAIN LINK FENCES AND GATES

PUMP JACK SYSTEM AND ACCESSORIES

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

WALKING-WORKING SURFACES (SLIPS, TRIPS, AND FALLS)

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

DE Frame with C Series Sidelight

How to secure your property after a disaster

One-third of all fatalities in the U.S. construction

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

H-Stud Area Separation Wall System

Roof Curbs, Extensions and Equipment Supports

City of San Diego, CWP Guidelines

INSTALLATION INSTRUCTIONS

Sun Windows General Information Sun New Construction Window Installation Instructions

STANDARD OPEN PATIO COVER

Mark Cramer Inspection Services, Inc.

GUARDRAIL POST STEEL

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

ATI Evaluation Service A Division of Architectural Testing Certification Services

Clad Direct Glaze Window Installation Instructions

S&W Race Cars and Components, Inc.

Automatic Door Selection Guide

SECTION 4: Cable Ladder Stainless Steel & Aluminium

MONDOATHENS BASKETBALL SET (Reference PK110)

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

PRO PANELS the artist s choice in display designed by artists, for artists. voice: fax:

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

SECTION SERIES 1500 VINYL PATIO DOORS

Rooflight INSTALLATION INSTRUCTIONS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

FALL PROTECTION WORK PLAN

Chapter 3: Fall Protection/ Scaffolding Safety

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

Transcription:

SECTION 05512 CAGED ALUMINUM ACCESS LADDERS ***** UPNO VR, Inc. manufactures several types of aluminum access ladders. This guide specification section can be used to specify fixed, wall mounted, vertical access ladders with integral safety cages. Ladders over 20 feet high are required to have safety cages. Vertical ladders less than 20 feet high can be specified in SECTION 05511 - FIXED ALUMINUM ACCESS LADDERS. Ship ladders can be specified in SECTION 05513 - ALUMINUM INCLINED LADDERS. ****************************************************************************** PART 1 - GENERAL 1.1 SUMMARY ***** UPNO VR, Inc. manufactures five models of caged aluminum access ladders. Select required type in the following paragraph and delete nonapplicable types. ***** A. Section includes: Fixed, wall mounted, vertical, aluminum, [roof hatch rail extension ladder with integral safety cage.] [roof over rail extension ladder with integral safety cage.] [return to rear of parapet ladder with integral safety cage.] [ladder with platform, return to rear of parapet, and integral safety cage.] [ladder with intermediate platforms, roof over rail, and integral safety cage.] B. Related sections: ***** List other specification sections dealing with work directly related to this section such as the following. ***** 1. Section 06100 - Rough Carpentry: Blocking in metal stud walls and partitions for anchorage of access ladders. 2. Section 07725 - Roof Hatch: Manufactured roof hatch to be accessed by aluminum ladder. ***** Safety post extensions are often used in conjunction with roof hatch access ladders. They can be provided separately or with ladder. ***** 3. Section 07726 - Ladder Safety Post Extension: Manufactured safety post extension to be attached to roof access ladder. 1.2 REFERENCES **** List by number and full title reference standards referred to in remainder of specification section. Delete non-applicable references. ***** CAGED ALUMINUM ACCESS LADDERS 05512-1

A. American National Standards Institute (ANSI): 1. ANSI A14.3 - Ladders, Fixed, Safety Requirements. B. American Society for Testing and Materials (ASTM) Publications: 1.3 SUBMITTALS 1. ASTM B209 - Aluminum and Aluminum-Alloy Sheet and Plate. 2. ASTM B221 - Aluminum-Alloy Extruded Bar, Rod, Wire, Shape, and Tube. A. Provide in accordance with Section 01330 - Submittal Procedures: 1. Product data for access ladders and accessories. 2. Shop drawings showing elevations, dimensions, safety cage, connections, size and type of fasteners, and fabrication and installation details. 3. Installation and maintenance instructions. 1.4 QUALITY ASSURANCE A. Access ladders shall be designed and installed to comply with ANSI A14.3. PART 2 - PRODUCTS 2.1 ACCEPTABLE MANUFACTURERS A. UPNO VR, Inc., 3 Crane Way, Hooksett, New Hampshire 03106; 603-625-8639. B. Manufacturers of equivalent products submitted and approved in accordance with Section 01630 - Product Substitution Procedures. 2.2 MATERIALS A. Extruded aluminum: ASTM B221, Alloy 6063 Temper T-6, non-spark. B. Sheet aluminum: ASTM B209 6063 Temper T-6. ***** Standard access ladder finish is mill finished aluminum. Electrostatically applied, powder paint color coatings can be provided as a special order. Contact UPNOVR, Inc. for information and assistance in specifying this special finish. ***** C. Finish: Mill finished aluminum. CAGED ALUMINUM ACCESS LADDERS 05512-2

2.3 GENERAL FABRICATION A. Field verify ladder dimensions prior to fabrication. B. Fabricate to designs indicated on Drawings and to meet performance requirements specified in Paragraph 1.4. C. Components shall be welded. Ladder shall not require field assembly. 2.4 VERTICAL CAGED ACCESS LADDER ***** UPNO VR, Inc. manufacturers 6 models of fixed, wall mounted, vertical access ladders with integral safety cages. Select required type from the following options and delete non-applicable options. ***** A. Type: Fixed, wall mounted, vertical, caged, aluminum, [roof hatch rail extension ladder; Model No. U-300] [roof over rail extension ladder; Model No. U- 301] [return to rear of parapet ladder; Model No. U-302] [ladder with platform and return to rear of parapet; Model No. U-303] [ladder with intermediate platforms and roof over rail; Model No. U-390] as manufactured by UPNO VR, Inc. ***** Include the following paragraphs to specify caged roof hatch rail extension ladder; Model No. U-300. This model is used for heights from 20 to 30 feet maximum and is mounted with side rails 3 inches above finish floor. ***** B. Nominal height: [[ ] feet.] [As indicated on Drawings.] C. Side rails: 1-3/4 inches by 3 inches tubes with 1/8 inch wall thickness. D. Rungs: 1-1/4 wide by 1-1/4 inches tube by [18] [24] inches long with corrugated surfaces and capable of 1,000 pounds load. Space 12 inches on center. Attach rungs in centerline of side rails by welding. ***** Include the following paragraphs to specify caged roof over rail extension ladder; Model No. U-301. This model is used for heights from 20 to 30 feet maximum and is mounted with side rails 3 inches above finish floor. ***** B. Nominal height: [[ ] feet.] [As indicated on Drawings.] C. Side rails: 1-3/4 inches by 3 inches tubes with 1/8 inch wall thickness. Extend rails 42 inches above [roof line.] [parapet.] D. Extension: At top of side rails provide 19 inches extension, 28 inches high, CAGED ALUMINUM ACCESS LADDERS 05512-3

constructed from 1-1/4 inches square tube grab bars with corrugated surfaces. E. Rungs: 1-1/4 inches square tube by [18] [24] inches long with corrugated surfaces and capable of 1,000 pounds load. Space 12 inches on center. Attach rungs in centerline of side rails by welding. ***** Include the following paragraphs to specify caged return to rear of parapet ladder; Model No. U-302. This model is used for heights from 20 to 30 feet maximum and is mounted with side rails 3 inches above finish floor. ***** B. Nominal height: [[ ] feet.] [As indicated on Drawings.] ***** Cross over span will be determined by width of parapet wall. ***** C. Cross over span: [[ ] inches.] [As indicated on Drawings.] D. Side rails: 1-3/4 inches by 3 inches tubes with 1/8 inch wall thickness. Extend rails 42 inches above parapet. Provide rails on opposite side mounted to rear of parapet and extending 42 inches above parapet and below parapet to roof line. E. Grab bars: Connect front and rear side rails with 4 pairs of 1-1/4 inches square tube grab bars with corrugated surfaces. F. Rungs: 1-1/4 inches square tube by [18] [24] inches long with corrugated surfaces and capable of 1,000 pounds load. Space 12 inches on center. Attach rungs in centerline of side rails by welding. ***** Include the following paragraphs to specify caged ladder with platform and return to rear of parapet; Model No. U-303. This model is used for heights from 20 to 30 feet maximum is mounted with side rails 3 inches above finish floor. ***** B. Nominal height: [[ ] feet.] [As indicated on Drawings.] ***** Cross over span will be determined by width of parapet wall. ***** C. Cross over span: [[ ] inches.] [As indicated on Drawings.] D. Side rails: 1-3/4 inches by 3 inches tubes with 1/8 inch wall thickness. Extend rails 42 inches above parapet. Provide rails on opposite side mounted to rear of parapet CAGED ALUMINUM ACCESS LADDERS 05512-4

and extending 42 inches above parapet and below parapet to roof line. E. Grab bars: Connect front and rear side rails with 4 pairs of 1-1/4 inches square tube grab bars with corrugated surfaces. F. Platform: Provide cross over platform fabricated from 6 inches wide by 1-3/4 inches deep aluminum treads with corrugated surface. G. Rungs: 1-1/4 inches square tube by [18] [24] inches long with corrugated surfaces and capable of 1,000 pounds load. Space 12 inches on center. Attach rungs in centerline of side rails by welding. ***** Include the following paragraphs to specify caged roof over rail extension ladder with intermediate platforms; Model No. U-390. This model is used for heights over 30 feet is mounted with side rails 3 inches above finish floor. ***** B. Configuration: Ladder shall be configured with [2] [ ] caged vertical ladder segments offset from each other and connected with intermediate platform with guardrail as indicated on Drawings. Nominal heights of ladder segments: 1. Lower segment: [ ] feet. 2. Upper segment: [ ] feet. C. Side rails: 1-3/4 inches by 3 inches tubes with 1/8 inch wall thickness. Extend rails of upper ladder segment 42 inches above [roof line.] [parapet.] D. Extension: At top of upper segment side rails provide 19 inches extension, 28 inches high. Construct from 1-1/4 inches square tube grab bars with corrugated surfaces. E. Rungs: 1-1/4 inches square tube by [18] [24] inches long with corrugated surfaces and capable of 1,000 pounds load. Space 12 inches on center. Attach rungs in centerline of side rails by welding. F. Intermediate platform: Provide intermediate cross over platform fabricated from 6 inches wide by 1-3/4 inches deep aluminum treads with corrugated surface. G. Guardrail: At intermediate platform provide guardrail constructed from 1-1/4 inches square tube grab bars with corrugated surfaces. Guardrail shall be 42 inches high CAGED ALUMINUM ACCESS LADDERS 05512-5

and connect side rails of 2 ladder segments as detailed on Drawings and reviewed shop drawings. 2.5 SAFETY CAGE A. Equip ladders with safety cages as detailed on Drawings and reviewed shop drawings. B. Fabricate from 2 inches wide by 1/4 inch thick aluminum vertical strips and horizontal loops welded to form cage around ladder. 1. Bottom loop radius: 17-1/2 inches. 2. Radius of other loops: 13-1/2 inches. 3. Provide 7 vertical strips equally spaced around perimeter of cage. 4. Space horizontal loops at 48 inches maximum. C. Minimum clearance from ladder to back of cage: 27 inches. D. Start cage [7] [8] [ ] feet above [grade] [intermediate platform] [roof level]. E. Extend safety cage 42 inches minimum above top rung and attach to side rails as detailed on Drawings and reviewed shop drawings. 2.6 ACCESSORIES A. Support brackets: 1. Wall brackets: Support ladder at top and bottom and at 48 inches maximum intermediate points with 2 by 1/4 inch minimum flat bar aluminum wall brackets. Allow 7 inches minimum clearance from wall to center line of rungs. ***** As an option, a hinged security door can be provided to cover bottom ladder rungs and prevent unauthorized roof access. Include the following paragraph for this option. ***** B. Security door: Provide hinged security door to cover bottom rungs and prevent unauthorized roof access. 1. Construction: Fabricate from 11 gage flat aluminum sheet covering front of ladder. Provide side flanges extending toward wall and meeting aluminum flange mounted to wall. 2. Equip door with continuous stainless steel hinge and padlock hasp. CAGED ALUMINUM ACCESS LADDERS 05512-6

***** Safety post extension can be provided in conjunction with roof hatch and specified in other sections. As a option, safety post extension can be provided by UPNO VR, Inc. with access ladder. Include the following paragraph to specify this option. ***** C. Safety post extension: Post extension for fixed ladders constructed of tubular aluminum sections with adjustable mounting brackets for attachment to top of ladder. 1. Operation: Upward and downward movement controlled by spring balancing mechanism activated by release rod. Automatically locks when fully extended. 2. Permanently mount operating instructions on safety post to be plainly visible to ladder users. ***** Fall arrest system can be provided in lieu of safety cage and specified in other sections. As a option, a fall arrest system can be provided by UPNOVR, Inc. with access ladder. Include the following paragraph to specify this option. ***** D. Safety post extension: Post extension for fixed ladders constructed of tubular aluminum sections with adjustable mounting brackets for attachment to top of ladder. 1. Operation: Upward and downward movement controlled by spring balancing mechanism activated by release rod. Automatically locks when fully extended. 2. Permanently mount operating instructions on safety post to be plainly visible to ladder users. PART 3 - EXECUTION 3.1 PREPARATION A. Prior to fabrication, field verify required dimensions. B. Coordinate provision of access ladder with provision of roof hatch specified in Section 07725 - Roof Hatch to ensure height and position of ladder is compatible with roof hatch curb. C. Coordinate ladder installation with construction of [CMU walls specified in Section 04220 - Concrete Unit Masonry to ensure block walls are adequately reinforced and cells grouted] [metal stud walls specified in Section 05400 - Cold Formed Metal Framing to ensure adequate support and blocking] [stud partitions specified in Section 09260 - Gypsum Board Assemblies to ensure adequate support and blocking] for attachment of brackets and support of ladder. CAGED ALUMINUM ACCESS LADDERS 05512-7

D. Insulate dissimilar metals to prevent electrolysis with bituminous paint or non-absorptive isolation pad to prevent contact. 3.2 INSTALLATION A. Install ladder and safety cage in accordance with manufacturer's instructions and reviewed shop drawings. B. Position ladder such that side rails end 3 inches above floor and center of rungs are 7 inches from wall. C. Securely anchor support brackets with fasteners of type and size recommended by manufacturer. Place wall brackets at top and bottom of ladder. Place intermediate wall brackets at 48 inches maximum. D. Ensure ladder and safety cage are vertical, plumb, [aligned with center of roof hatch,] and rigid. ***** Include the following paragraph is security door is required. ***** E. Install security door assembly and adjust for smooth operation. ***** Include the following paragraph if safety post extension is required. ***** F. Safety post extension: Attach to top 2 rungs of ladder and centered between side rails. Adjust post to extend 42 inches above top rung when roof hatch is open and post is fully extended. G. After installation inspect ladder to verify proper, secure, and safe installation. H. Clean ladder using clean water and mild detergent. Do not use abrasive agent, steel wool, or harsh chemicals. Rinse with clean water. END OF SECTION CAGED ALUMINUM ACCESS LADDERS 05512-8