FRONIUS IG PLUS TRANSFORMER INVERTER

Similar documents
/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

Fronius IG Plus. The next generation grid-connectedpvinverter.

How To Make A Fronius Cl Power Inverter

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL

Fronius IG Plus. The next generation grid-connected PV inverter

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

SUNNY TRIPOWER 5000TL 12000TL

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB central inverters PVS to 1000 kw

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Quick Connect. quick - simple - efficient.

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

SolarMax P series The power package for residential solar plants

Actuator-Sensor-Interface

Safety technique. Emergency stop module BO 5988 safemaster

Solar Inverters Product Catalogue. Solar inverters, monitoring and support for residential / commercial installations and power plants

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Photovoltaic Solar Energy Unit EESFB

Solar Inverter Product Overview. Solar inverters, monitoring and support for PV installations of all sizes.

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

3753 en /b VE/B - VE/RG Va V riable speed drives

Inverters. The product range.

Technical data UNIBLOCK UBSF

vacon 8000 solar inverter a driving force in solar energy

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

EGSTON Standard E2xFxWx 12W

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

ADM1TE 5/30A DIN rail single phase two wire energy meter

RM4TG20 three-phase network control relay RM4-T - range V

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SYSTEM MONITORING Locally and remotely

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

Thyristor-controlled power supplies and battery chargers

Technical Information POWER PLANT CONTROLLER

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Sunny Family 2012 PRODUCT CATALOG

SRS2025. Home & small Business. Energy Storage Solution

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Innovation Powers Efficiency

Data Sheet. PIKO-Inverter

INVERTER SYSTEM PRODUCT BROCHURE

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

SURGE PROTECTIVE DEVICES

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

E-STOP relays, safety gate monitors

EFC Frequency converters

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Pluggable interface relays CR-P Pcb relays

The solution for Europe: Type 2 charging socket with or without shutter

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

BB800 Off-Grid Solar System

Thermistor motor protection

Servo drives. Compact converter IndraDrive Cs

Contact expander modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

PNOZsigma - Base units

Power Meter Series 700

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

User s Manual Before using the inverter, you need to read and save the safety instructions.

Re-defining the utility-scale inverter

Operating Manual UWAPS-TINY Series

RY2 miniature industrial relays

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Redundancy Module QUINT-DIODE/40

Three-phase monitoring relay CM-PFE

Yield Reduction due to Shading:

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

WVC300 Micro-inverter solar grid system (Power line communications)

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Type: DILM9 10(24VDC) Article No.:

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

HERZ-Thermal Actuators

Frequency Converter Fv

Contact expansion modules

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Counter for Energy. We make energy measurable and secure your future.

Power Supplies 3. SDN-P DIN Rail Series

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Type: DILM32 10(24V50HZ) Article No.:

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Electronic Control Devices The European Product Catalogue 2007

Transcription:

12 / Fronius IG Plus transformer inverters TRANSFORMER INVERTER / The allrounder with maximum yield. 30 V-1 / 35 V-1 / 50 V-1 / Powerful and compact: the three single-phase devices rated at 3 to 4 kw are suitable, for example, for PV systems in single-family homes. 70 V-2 / 100 V-2 / The big brother: the two-phase connection ensures a phase load unbalance of less than 4 kva. Rated at 6.5 or 8 kw. 100 V-3 / 120 V-3 / 150 V-3 / Maximum power: three phases in a single device for PV systems right into the megawatt range rated at 8, 10 and 12 kw. 100 V-3 AVAILABLE FROM JULY 2011!

Fronius IG Plus transformer inverters / 13 / MIX concept / HF transformer switchover / Module Manager / PC board replacement / Mounting system / Ventilation concept concept DEPENDABLE YIELD, RELIABLE AND COMPLETELY VERSATILE: / The Fronius IG Plus generation of inverters represents an evolution of the proven Fronius IG product family. Power categories from 3 to 12 kw promise suitability for every possible system size. With a maximum efficiency of 95.9%, the Fronius IG Plus range achieves one of the highest values for transformer inverters. / Compatible with practically all module configurations and technologies: Works perfectly with every type of module and is particularly suitable for thin-layer modules. The wide input voltage range, electrical isolation and standard integral earthing option means the inverter is extremely flexible in terms of system sizing and planning. / Sophisticated ventilation concept The air required for cooling is sucked in through the side panel and fed over the cooling element through a sealed channel. Dust and moisture therefore never come into contact with the PC board and the inverter will operate reliably in the long term. / Involved in grid management: The provision of reactive power, three-phase feed-in and dynamic grid backup means the inverters can be connected to the grid more easily and become actively involved in grid management. / Integrated string collection box with safety monitoring: Simplifies installation. Up to six strings can be connected directly; if a fuse is faulty a message appears instantly on the display. / Power-Plug system The connection and power module compartments are fitted separately. The Power-Plug connects both parts to create a fixed unit. During servicing, the connector remains on the wall all settings and configurations are thus retained.

14 / Technical data: Fronius IG Plus TECHNICAL DATA: INPUT DATA 30 V-1 35 V-1 50 V-1 70 V-2 100 V-2 DC maximum power at cos φ = 1 3,170 W 3,710 W 4,260 W 6,880 W 8,520 W Max. input current (I dc max) 13.8 A 16.1 A 18.5 A 29.9 A 37.0 A Min. input voltage (U dc min ) 230 V Feed-in start voltage (U dc start ) 260 V Nominal input voltage (U dc,r ) 370 V Max. input voltage (U dc max ) 600 V MPP voltage range (U mpp min U mpp max ) 230 500 V Number of DC inputs 6 OUTPUT DATA 30 V-1 35 V-1 50 V-1 70 V-2 100 V-2 AC nominal output (P ac,r ) 3,000 W 3,500 W 4,000 W 6,500 W 8,000 W Max. output power 3,000 VA 3,500 VA 4,000 VA 6,500 VA 8,000 VA Max. output current (I ac max ) 13.0 A 15.2 A 17.4 A 14.1 A (28.3 A) 1) 17.4 A (34.8 A) 1) Grid connection (U ac,r ) 1~NPE 230 V 2~NPE 400 V / 230 V (1~NPE 230 V) 1) Min. output voltage (U ac min ) 180 V Max. output voltage (U ac max ) 270 V Frequency (f r ) 50 Hz / 60 Hz Frequency range (f min f max ) 46 Hz 65 Hz Distortion factor < 3 % Power factor (cos ϕ ac,r ) 0.85 1 ind. / cap. 1) Single-phase (opt.) GENERAL DATA 30 V-1 35 V-1 50 V-1 70 V-2 100 V-2 Dimensions (height x width x depth) 673 x 434 x 250 mm 968 x 434 x 250 mm Weight 23.8 kg 36.9 kg Degree of protection IP 54 2) Protection class 1 Overvoltage category (DC / AC) 2 / 3 Night-time consumptioncl < 1 W Inverter concept HF transformer Cooling Regulated air cooling Installation Indoor and outdoor installation Ambient temperature range from 20 C to +55 C Permitted humidity 0% to 95% DC connection technology Screw terminal connection 1.5 mm² 16 mm² AC connection technology Screw terminal connection 2.5 mm² 35 mm² Certificates and compliance with standards DIN V VDE V 0126-1-1, ÖVE/ÖNORM E 8001-4-712, UTE C15-712, EN 50438, G83, G59, C 10 / 11, CER 06-190, Guida per le connessioni alla rete elettrica di ENEL Distribuzione, AS 4777-1, AS 4777-2, AS 4777-3 2) Please refer to the information in the operating instructions regarding correct installation of the inverter.

Technical data: Fronius IG Plus / 15 EFFICIENCY 30 V-1 35 V-1 50 V-1 70 V-2 100 V-2 Max. efficiency 95.7 % 95.7 % 95.7 % 95.7 % 95.7 % European efficiency (η EU ) 94.8 % 95.0 % 95.0 % 95.1 % 95.2 % η at 5% P ac,r 87.9 / 87.6 / 87.2 % 88.2 / 88.1 / 87.4% 88.7 / 88.6 / 88.2 % 90.4 / 91.1 / 90.3 % 90.9 / 91.4 / 90.5 % η at 10% P ac,r 90.4 / 90.8 / 90.2 % 91.6 / 92.3 / 91.5 % 92.1 / 92.7 / 92.1 % 93.0 / 93.2 / 92.0 % 93.6 / 93.7 / 92.5 % η at 20% P ac,r 93.6 / 94.2 / 93.2 % 94.1 / 94.6 / 93.4 % 94.4 / 94.7 / 93.5 % 94.7 / 94.7 / 94.0 % 94.7 / 95.1 / 94.4 % η at 25% P ac,r 94.3 / 94.6 / 93.5 % 94.6 / 94.8 / 93.7 % 94.8 / 94.9 / 94.0 % 94.9 / 95.1 / 94.4 % 94.9 / 95.3 / 94.8 % η at 30% P ac,r 94.7 / 94.9 / 93.8 % 94.9 / 95.0 / 94.1 % 95.1 / 95.2 / 94.5 % 95.0 / 95.3 / 94.8 % 94.9 / 95.4 / 95.0 % η at 50% P ac,r 95.2 / 95.5 / 94.9 % 95.3 / 95.7 / 95.3 % 95.2 / 95.7 / 95.3 % 95.3 / 95.5 / 94.9 % 95.2 / 95.7 / 95.2 % η at 75% P ac,r 95.1 / 95.7 / 95.4 % 94.9 / 95.6 / 95.4 % 94.7 / 95.5 / 95.4 % 95.0 / 95.7 / 95.3 % 94.7 / 95.5 / 95.3 % η at 100% P ac,r 94.7 / 95.5 / 95.4 % 94.4 / 95.2 / 95.1 % 94.0 / 95.0 / 95.0 % 94.5 / 95.4 / 95.2 % 94.0 / 95.1 / 95.0 % MPP adaptation efficiency >99.9 % and at U mpp min / U dc,r / U mpp max PROTECTIVE EQUIPMENT 30 V-1 35 V-1 50 V-1 70 V-2 100 V-2 DC insulation measurement Overload behaviour DC circuit breaker Warning/shutdown (depending on country setup) at R ISO < 500 kohm Operating point shift, power limitation Integrated 100 V-2 EFFICIENCY CURVE V TEMPERATURE DERATING EFFICIENCY [%] 96 95 94 93 OUTPUT POWER [W] 9.000 8.000 7.000 6.000 5.000 Fronius IG Plus 100 V-2 92 4.000 Fronius IG Plus 50 V-1 3.000 91 2.000 90 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1.000 20 25 30 35 40 45 50 55 STANDARDISED OUTPUT POWER P AC /P AC,R AMBIENT TEMPERATURE [ C]

16 / Technical data: Fronius IG Plus TECHNICAL DATA: INPUT DATA 100 V-3 1) 120 V-3 150 V-3 DC maximum power at cos φ = 1 8,430 W 10,590 W 12,770 W Max. input current (I dc max ) 36.7 A 46.0 A 55.5 A Min. input voltage (U dc min ) 230 V Feed-in start voltage (U dc start ) 260 V Nominal input voltage (U dc,r ) 370 V Max. input voltage (U dc max ) 600 V MPP voltage range (U mpp min U mpp max ) 230 500 V Number of DC inputs 6 OUTPUT DATA 100 V-3 1) 120 V-3 150 V-3 AC nominal output (P ac,r ) 8,000 W 10,000 W 12,000 W Max. output power 8,000 VA 10,000 VA 12,000 VA Max. output current (I ac max ) 11.6 A 14.5 A 17.4 A Grid connection (U ac,r ) 3~NPE 400 V / 230 V Min. output voltage (U ac min) 180 V Max. output voltage (U ac max ) 270 V Frequency (f r ) 50 Hz / 60 Hz Frequency range (f min f max ) 46 Hz 65 Hz Distortion factor < 3 % Power factor (cos ϕ ac,r ) 0.85 1 ind. / cap. GENERAL DATA 100 V-3 1) 120 V-3 150 V-3 Dimensions (height x width x depth) 1,263 x 434 x 250 mm Weight 49.2 kg Degree of protection IP 54 2) Protection class 1 Overvoltage category (DC / AC) 2 / 3 Night-time consumption < 1 W Inverter concept HF transformer Cooling Regulated air cooling Installation Indoor and outdoor installation Ambient temperature range from 20 C to +55 C Permitted humidity 0% to 95% DC connection technology Screw terminal connection 1.5 mm² 16 mm² AC connection technology Screw terminal connection 2.5 mm² 35 mm² Certificates and compliance with standards DIN V VDE V 0126-1-1, ÖVE/ÖNORM E 8001-4-712, UTE C15-712, EN 50438, G83, G59, C 10 / 11, CER 06-190, Guida per le connessioni alla rete elettrica di ENEL Distribuzione, AS 4777-1, AS 4777-2, AS 4777-3 1) Fronius IG Plus 100 V-3 devices may only be used in Europe (except Italy). 2) Please refer to the information in the operating instructions regarding correct installation of the inverter. 100 V-3 AVAILABLE FROM JULY 2011!

Technical data: Fronius IG Plus / 17 EFFICIENCY 100 V-3 1) 120 V-3 150 V-3 Max. efficiency 95.9 % 95.9 % 95.9 % European efficiency (η EU ) 95.3 % 95.4 % 95.4 % η at 5% P ac,r 91.7 / 91.9 / 90.3 % 91.5 / 92.2 / 90.7 % 91.8 / 92.5 / 91.1 % η at 10% P ac,r 93.1 / 93.1 / 92.0 % 93.4 / 93.7 / 92.6 % 94.0 / 94.3 / 93.2 % η at 20% P ac,r 94.3 / 94.9 / 94.2 % 94.6 / 95.2 / 94.5 % 94.7 / 95.1 / 94.6 % η at 25% P ac,r 94.6 / 95.2 / 94.5 % 94.7 / 95.3 / 94.7 % 95.1 / 95.3 / 94.7 % η at 30% P ac,r 94.7 / 95.2 / 94.5 % 95.0 / 95.4 / 94.7 % 95.1 / 95.3 / 94.9 % η at 50% P ac,r 95.3 / 95.8 / 95.0 % 95.3 / 95.9 / 95.1 % 95.3 / 95.9 / 95.3 % η at 75% P ac,r 95.3 / 95.9 / 95.3 % 95.0 / 95.5 / 95.4 % 94.7 / 95.6 / 95.4 % η at 100% P ac,r 94.9 / 95.7 / 95.4 % 94.6 / 95.5 / 95.3 % 94.0 / 95.2 / 95.1 % MPP adaptation efficiency >99.9 % and at U mpp min / U dc,r / U mpp max PROTECTIVE EQUIPMENT 100 V-3 1) 120 V-3 150 V-3 DC insulation measurement Overload behaviour DC circuit breaker Warning/shutdown (depending on country setup) at R ISO < 500 kohm Operating point shift, power limitation Integrated 150 V-3 EFFICIENCY CURVE V TEMPERATURE DERATING EFFICIENCY [%] 96 94 92 OUTPUT POWER [W] 13.000 11.000 9.000 7.000 Fronius IG Plus 150 V-3 90 5.000 88 3.000 86 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 1.000 20 25 30 35 40 45 50 55 STANDARDISED OUTPUT POWER P AC /P AC,R AMBIENT TEMPERATURE [ C]