Tank Top Return-Line Filter Pi 530

Similar documents
HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

15/40/80CN Series Medium Pressure Filters

Return line filters. Return line filters

Hydraulic Control Solutions

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

15/40/80CN Series Coreless Medium Pressure Filters

Filter Elements E /05.06

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

2/2 and 3/2 Way Size 6 Seat Valves

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

SOLENOID VALVES 3-4 WAY

Duplex Filters 40 FLDK 0008(C)-0120(C)

Pressure reducing valve, direct operated, Type ZDR 6 D

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Automatic Back-Flushing Filter AutoFilt RF9.

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar

Hydraulic control unit series

Plastic tube flowmeters Series PT/PS

type V46, solenoid or pneumatic operated

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Instruction Manual Differential Pressure Transmitter

Pressure relief valves Size 6

Control- and feedback head for integrated mounting on Robolux valves Type 2036

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Chapter 5: Flow Valves

3/2- and 2/2-way cartridge valve type BVE

Breathers and Filler Breathers.

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Aerospace and Defence

SunMaxx Solar Filling Station Operating Instructions

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Digital inductive conductivity transmitter

Variable Displacement Pump AA10VSO

Series TMM Axial Piston Motor. Technical Information

2-way flow control valve Type 2FRM 6

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

SAFETY BLOCK type BS 9.3 E 01-12

In-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters

Fixed displacement vane pumps

Cooling system components, removing and installing

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Auxiliary Rams USERS MANUAL

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Assisted lift operated 2/2-way solenoid valves Type EV250B

PBX Series Quick Fit Connector Bimetallic Steam Traps

System 8. ü ( System 8

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Flow divider (flow distributor), type TQ

How To Use A Flowmeter

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

ACCUMULATOR INSTALLATION

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

Machine needle shut-off nozzle type-a

Laddomat Charging unit

SISTO-16TWA/HWA/DLU. Type Series Booklet

Cooling system components, removing and installing

Open center control block in monoblock design MO-40

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

Description of functions

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

Backflush filter R8-30W

Rotary screw compressors kw 5,5 7, , bar MODULO

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

3/2-way Solenoid Valve, direct-acting, NC or NO

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

SERIES FRI. Maximum working pressure 20 bar F l o w r a t e t o l / m i n. s. p. a

DATA PD RE21.., KX..., Quick Release Valves. Product. Function. Technical Features. Range Overview

Assembly overview - fuel tank

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Standard Hydraulic Piping Flushing Procedure

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

Operating Instructions

V47 Series Temperature Actuated Modulating Water Valves

SureSite Magnetic Liquid Level Indicator

Transcription:

Tank Top Return-Line Filter Pi 530 Nominal size 35 and 50 1.Features High performance filters for modern hydraulic systems - Provided for tank top installation Modular system Compact design Minimal pressure drop through optimal flow design Visual/electrical/electronic maintenance control Threaded alt. hose connections - Quality filters, easy to service Equipped with highly efficient glass fibre Sm-x filter or umweltfreundlichen, voll veraschbaren Mic Filterelementen Beta rated elements according to ISO 16889 multipass test Elements with high differential pressure stability and dirt holding capacity Worldwide distribution

2. Flow rate/pressure drop curve complete filter y = differential pressure p [bar x = flow rate V [l/min] Tank top return-line filter Pi 530 NG 35+50 2

3. Separation grade characteristics 4. Filter performance data tested according to ISO 16889 (multipass test) Sm-x-elements with max. p 10 bar Sm-x 3 β 5(C) 200 Sm-x 10 β 10(C) 200 Sm-x 25 β 20(C) 200 values guaranteed up to 5 bar differential pressure y = beta-value x = particle size [µm] determined by multipass tests (ISO 16889) calibration according to ISO 11171 (NIST) 5. Quality assurance MAHLE filters and filter elements are produced according to the following international standards: Norm DIN ISO 2 941 DIN ISO 2 942 DIN ISO 2 943 DIN ISO 3 723 DIN ISO 3 724 ISO 3 968 ISO 10 771.1 ISO 16 889 Designation Hydraulic fluid power filter elements; verification of collapse/burst resistance Hydraulic fluid power filter elements; verification of fabrication integrity Hydraulic fluid power filter elements; verification of material compatibility with fluids Hydraulic fluid power filter elements; method for end load test Hydraulic fluid power filter elements; verification of flow fatigue characteristics Hydraulic fluid power-filters-evaluation of pressure drop versus flow characteristics Fatigue pressure testing of metal containing envelopes in hydraulic fluid applications Hydraulic fluid power filters-multi-passmethod for evaluation filtration performance of a filter element 6. Symbols Tank top return-line filter Pi 530 NG 35+50 3

7. Order numbers Example for ordering filters: 1. Housing design 2. Filter element Housing NG 35 with hose connection, bypass valve, breather and pressure gauge Type: Pi 53003/1-141 Mic 10 Type: 852 939 Mic 10 7.1 Housing design with with with pressure pressure Nominal with bypass switch switch size Version bypass and normally normally NG [l/min] Type filter head 1.5 bar with breather gauge closed open 35 50 Pi 53003/1-009 Pi 53003/1-020 Pi 53003/1-144 Pi 53003/1-145 Pi 53003/1-146 Pi 53003/1-141 Pi 53003/1-142 Pi 53003/1-143 Pi 53003/2-009 Pi 53003/2-020 Pi 53005/1-009 Pi 53005/1-020 Pi 53005/1-044 Pi 53005/1-145 Pi 53005/1-146 Pi 53005/1-141 Pi 53005/1-142 Pi 53005/1-143 Pi 53005/2-009 Pi 53005/2-020 Filter head PA 6 with hoseconnection DN20 Al-filter head G½ Filter head PA 6 with hoseconnection DN20 Al-filter head G½ 7.2 Filter elements* Nominal size Order max. p Filter surface NG [l/min] number Type Filter material [bar] [cm²] 78309387 852 939 Mic 10 Mic 10 78206781 852 939 Mic 25 Mic 25 5 870 35 79312117 852 588 Sm-x 3 Sm-x 3 79312125 852 588 Sm-x 10 Sm-x 10 10 650 79312133 852 588 Sm-x 25 Sm-x 25 78309395 852 940 Mic 10 Mic 10 79312315 852 940 Mic 25 Mic 25 5 1100 50 79312158 852 945 Sm-x 3 Sm-x 3 79312166 852 945 Sm-x 10 Sm-x 10 10 810 79312174 852 945 Sm-x 25 Sm-x 25 * a wider range of element types is available on request Tank top return-line filter Pi 530 NG 35+50 4

7.3 Breather element (only for filter head PA 6, batch size 3 pcs.) Nominal size NG [l/min] Order number Type Filter material Filter surface [cm²] 35 50 78206831 852 937 Mic 40 8. Technische Daten Design: tank mounting filter Nominal pressure: 6 bar (90 psi) Test pressure: 9 bar (130 psi) Temperature range: -10 C to +80 C (other temperature ranges on request) Bypass setting: p 1.5 bar Filter head material: plastic-pa 6/Al Filter housing material: plastic PA 6 Filter cover material: plastic PA 6 Indication range of pressure gauge: 0 to 4 bar Activating pressure of pressure switch: 1.2 bar Electrical data of pressure switch: Max. voltage: 42 V Max. current 2 A Contact load: 100 VA Type of protection: IP 65 - with protection cap Contact: normally open/closed Electrical connection: AMP 6,3 DIN 46248 connector according to DIN 46247, connection method 2-pole We draw attention to the fact that all values indicated are average values which do not always occur in specific cases of application. Our products are continually being further developed. Values, dimensions and weights can change as a result of this. Our specialized department will be pleased to offer you advice. We recommend to contact us concerning applications of our filters in areas governed by the EU Directive 94/9 EC (ATEX 95). The standard version can be used for liquids based on mineral oil (corresponding to the fluids in Group 2 of Directive 97/23 EC Article 9). If you consider to use other fluids please contact us for additional support. Subject to technical alteration without prior notice. Tank top return-line filter Pi 530 NG 35+50 5

9. Dimensions Version with filter head Al All dimensions except "D" in mm. Typ A B C D E Pi 53003/1 203 133,5 DN20-130 Version with filter head PA 6 *E= Minimum clearance for filter element removal * Ø 60= Mounting hole Ø 60 *G¼= Option Pi 53003/2 203 135,5 - G½ 130 Pi 53005/1 241 171,5 DN20-180 Pi 53005/2 241 173,0 - G½ 180 Tank top return-line filter Pi 530 NG 35+50 6

10. Installation, operating and maintenance instructions 10.1 Filter installation When installing the filter make sure that : a) Sufficient space is available to remove filter element and filter housing b) The mounting hole in the tank top is not excessively large, to ensure proper sealing, c) The filter is free of tension after installation, max. torque 7 Nm. Preferably the filter should be installed with the filter housing pointing downwards. 10.5 Replacement of air breather filter element (plastic filter head only) Push slightly on the lid and air breather element downwards (lid A). Remove lid and element from the lower hook. Pull out element from the lid. Install new element in the lid. Installation in reverse order. Check correct position of the lid. 10.2 Connecting the electrical pressure switch The electrical pressure switch is connected via connectors according to DIN 46247. 10.3 When should the filter element be replaced? 1. Filters equipped with pressure gauge: When the dynamic pressure reaches 1.2 bar (red/green indication), the filter element must be replaced. 2. Filters equipped with pressure switch: During cold starts, the pressure switch may give a signal. If the electrical signal has not switched off after reaching operating temperature, the filter element must be replaced after the end of the shift. 3. Filters without indicator: The filter element should be replaced after trial run or flushing of the system. Afterwards follow instructions of manufacturer. 4. Please, always ensure that you have original MAHLE spare elements in stock: Disposable elements (MIc, Sm-x) cannot be cleaned. 10.4 Element replacement 1. Stop system and relieve filter from pressure. 2. Unscrew cover, turning counter-clockwise. 3. Remove filter housing and filter element by pulling upwards. 4. Remove filter element with a side-to-side motion. 5. Clean the filter housing with a suitable medium. 6. Check O-rings on filter cover and filter housing for damage. Replace, if necessary. 7. Make sure that the order number on the spare element corresponds to the order number of the filter name-plate. 8. Remove filter element from plastic bag and reassemble in reverse order (items 1 to 4). 9. Contaminated Mic elements can be reduced to ashes. Sm-x filter elements must be disposed in another way. Note: Filter element and air breather element should be always replaced at the same time. Subject to technical alteration without prior notice. Tank top return-line filter Pi 530 NG 35+50 7

11. Spare parts list Order numbers for spare parts Type Order number Seal kit NBR Pi 530.../1 78309072 Pi 530.../2 78209062 Pressure gauge 79358326 Pressure switch normally closed 77870587 normally open 77863814 Breather element for Pi 530.../1 (batch size 3 pcs.) 78206831 Eigenbrodt AB Web: www.eigenbrodt.se Tel:+46 (0)8-594 63 400 E-mail: kontakt@eigenbrodt.se Tank top return-line filter Pi 530 NG 35+50 8