Central Air and Heating Systems

Similar documents
Bring the fresh in. Dedicated Outside Air Systems

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

ECOCIAT. Domestic hot water heat recovery unit

york air-conditioning products Residential & VRF News 2015

FTQ. Daikin Inverter Ducted Heat Pump

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Nordic Heat Pump Product Guide

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Glossary of Heating, Ventilation and Air Conditioning Terms

HVAC Systems: Overview

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

LG Electronics AE Company, Commercial Air Conditioning

Geothermal Comfort Systems

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

HVAC Processes. Lecture 7

Natural geothermal energy.

THE ORIGINAL HIGH VELOCITY CENTRAL AIR CONDITIONING SYSTEM

We have been working in an ideal climate for thirty years.

Combi Unit Genius. The energy efficient Building Service Centre

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Cooling kw Heating kw

Energy Efficiency. Energy Efficient Home Cooling:

Nirvana. Cycling Refrigerated Dryers

MAC-120HE-01 Air-Cooled Chiller

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

HVAC Basic Science - System Capacity

Hot Water. Heat pump water heaters. Residential and Commercial R410a

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

The Benefits Really Add Up

ARMSTRONG AIR HEAT PUMPS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Innovent LASER Packaged Fresh Air Conditioning Units

FTXS. Wall Mount Heat Pump or Cooling Only

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Lesson 36 Selection Of Air Conditioning Systems

3/29/2012 INTRODUCTION HVAC BASICS

Think Green Think Renewable Think

Cased/Uncased Coils For Gas And Oil Furnaces

SECTION HEAT PUMPS

Greensource iseries HY Model Unitary Air Handler/Fan Coil

CRAC Precision climate control units for data centres

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Selection Tips For Air-Conditioning Cooling Systems

catalog Single Package Vertical Air Conditioners and Heat Pumps

NEW 3-PIPE ECOi MF2 SERIES

Creating Efficient HVAC Systems

PRODUCT CATALOG. Indoor Units

LG AIR CONDITIONING SYSTEMS

Condensing Boiler Efficiency

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DUCTED AIR CONDITIONING SOLUTIONS

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

An air conditioner that redefines comfort and efficiency.

DAikin Altherma low temperature heat pump. end user leaflet

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

HVAC Simplified Approach Option

Air-Conditioning Buying Guide

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

EHDC. Cooling system for Data Center and server cabinets.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Electric Flow Boiler

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Trane EnviroWise Geothermal Systems. Renewable energy keeps the comfort coming.

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

YUTAKI S. Domestic Heating

Single Zone LCD Thermostat Operating Instructions

Building Energy Systems. - HVAC: Heating, Distribution -

Inverter Air Conditioning for Light Commercial Use

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Operation and Installation Manual. Max Series

CoolTeg Plus Chilled Water (CW) version: AC-TCW

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

How To Design A Building In New Delhi

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

FCQ. Roundflow Cassette Heat Pump or Cooling Only

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Commissioning - Construction Documents (Page 1 of 6)

EnergyPro Building Energy Analysis. Assisted Living Building

News in Data Center Cooling

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

GEOTHERMAL HEATING AND COOLING INTRODUCTION

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Transcription:

Central Air and Heating Systems COMFORT When You NEED IT "Water is far superior to air when it comes to moving heating or cooling through buildings." -John Siegenthaler

COMFORT When You NEED IT SpacePak Hydronics is taking the comfort and flexibility of water-based central heating and cooling systems to new levels of performance. In any season, SpacePak units provide perfectly conditioned air with reliability and efficiency. Hydronic Heating & Cooling Hydronic technology has long been known for providing unsurpassed heating comfort. New innovative technologies have allowed hydronic equipment manufacturers the opportunity to provide complete packaged solutions for both space heating and central cooling using the known advantages of hydronics over that of traditional forced air systems. Using the same physical properties that make water ideal for conveying heat also make it ideal for conveying cooling. Cooling is simply the removal of heat from an occupied space. Water is capable of absorbing substantially more (almost 3500X more) heat than air for the same temperature change. Therefore, chilled water circulated through a high efficiency terminal unit is ideal for absorbing heat from an occupied space without the intrusive ductwork associated with forced air systems. Small Scale Hydronics The concept of using water as a heat transfer medium for cooling is not new and has long been used by commercial engineers through the use of chillers, which reduce circulated water to the range of 40 to 50 F and then disperse the conditioned air through various types of terminal units into the occupied space in a much more efficient and environmentally friendly process than all-air systems. Small scale hydronic (chilled water) cooling in residential and light commercial applications is done safely and easily through much smaller space requirements than that of traditional ducted systems with increased operating efficiencies and is more aesthetically pleasing at the same time. 2

Packaged Solutions SpacePak Hydronics offers a total packaged solution for all residential and light commercial applications. Solstice Heat Pumps (air to water) in combination with our various styles of modern aesthetically pleasing emitters provide the ultimate in total year-round comfort. Chiller or heat pump based systems are the environmentally friendly choice for both heating and cooling by keeping all refrigerant safely contained outside of the occupied space. Benefits Energy Efficient Ease of Installation Minimally Invasive Aesthetically Pleasing Easily Zoned Environmentally Friendly Types of Emitters Hydronic Fan Coils AirCell HighWall ThinWall Chilled-beams Radiant Ceiling Panels System Layout Solstice Key: = Supply = Return Illustration depicts heating application. In cooling applications chilled water replaces hot water supply lines. 3

AIR DISTRIBUTION MODULE Standard Features ECM Variable Speed Fan Technology 110v Power Supply Heating & Cooling Hydronic Coil Lightweight Heavy-Duty Molded Plastic Shell Outer Insulation Jacket Internal Drain Pan Silent Operation (22dBA @ 3 ) Integrated Control Platform WiFi Enabled Devices / Laptops / Smart Phones Fan Speed Control Auto Timed Zone Control Fresh Air Induction Control (Optional) Temperature Set-Points Alarm Settings Specifications Heating Cooling Entering Water Temperature 160 F 42 F Btu/h 24,000 Tons 1.2 Fan Watts 90W 90W CFM 330 300 EER 13.7 14.0 Flow Rate GPM 3.5-5 Weight lbs. 39 Dimensions 4

AirCell Simplicity - Aspiration Through the use of high efficiency variable speed EC motors and a unique low temperature hydronic coil design, AirCell distributes perfectly conditioned air to any occupied space. Whether heating, cooling or ventilation, AirCell does it all. Working in conjunction with any hydronic supply system including boilers, reverse cycle chillers, heat pumps and geothermal AirCell allows full control and distribution of conditioned air with ultra-low energy consumption while reducing harmful CFC s by up to 40-60% over conventional DX systems. When connected to today s high efficiency condensing boilers AirCell guarantees ultra-efficiency utilizing lower supply water temperatures maximizing the performance of your boiler investment. Each AirCell ships with a thermal insulation cover Superior Insulation Minimizes Heat Gains / Losses Reduces Sweating in Humid Conditions Easy Snap Together Durable Design AirCell s integrated control platform continuously monitors the return air and water coil sensors while controlling the fan speed in response to the programmed set-points (including on/off times, fresh air, temperature and numerous other custom variables). Communication and programming is performed through either wall-mount thermostat controls or using a WiFi 802.11 enabled device including smart phones and computers. AirCell Cooling Capacity AirCell Heating Capacity Entering Water Temp F Data based upon 300 CFM air entering at 80 DB, 67 DB, 3.5-5 GPM Entering Water Temp F Data based upon 330 CFM air entering at 70 DB, 3.5-5 GPM water flow 5

EXTREME Solstice Extreme, SpacePak s low ambient heat pump provides primary heating and cooling even in severe weather climates. Its environmentally friendly design uses EVI technology and the clean efficient characteristics of hydronics as its primary energy source to deliver perfectly conditioned air to any occupied space. Standard Features Enhanced Vapor Injection Technology (EVI) 48,000 BTU/h at 0 F at 140 F Heating Supply 4 Ton at 95 F at 47 F Cooling Supply Highest R-410A COP and EER Simple Piping & Pumping Installation & Service Friendly Easily Zoned Proven Integrated Control Low Amp Requirements Outdoor Reset Green Hydronic Energy No Refrigerant in Occupied Space Low Ambient Freeze Protection Enhanced Vapor Injection (EVI) The award winning EVI technology and high efficiency condenser used in SpacePak low ambient heat pumps, provides improved efficiency, reliability and heating capacities. EVI increases heating capacity by over 30%, making it the perfect compressor for severe ambient conditions (0 F) in cold climates, while maintaining the ability to cool during the summer months. EVI Tube Motor Dynamic Exhaust Valve Dynamic Scroll 6 +30% Heating Performance at 140 F Supply 50% Larger Condenser Coil Energy Efficient Reliable Specifications Model LAHP - 048 COP Heating Capacity *48000 BTUh 14.06 kw 2.42 Cooling Capacity **48,000 BTUh 13.5 kw 3.00 Voltage 230v/1ph/60Hz Min Supply Temp 42 F 7 C Max Supply Temp 140 F 60 C Min Water Flow 10 gpm 1.80 m3/hr Max Water Flow 14 gpm 3.20 m3/hr dp @ Max Flow 20.7 ft 62 kpa Heating Current 21.2 amps Cooling Current 23.5 amps Noise Level 62 db(a) Compressor Scroll X 2 Installed Weight 386 lbs 175 Kg * at 0 F ambient, 120 F supply water (-16 C / 52 C) ** at 95 F ambient, 47 F supply water (35 C / 12 C)

Dimensions EXTREME Performance Cooling Operation at 47 F Water Ambient Temp Capacity Electrical Heat Pump Heat Pump BTU/hr Power Watts COP EER 82 F 56,000 4,800 3.4 11.7 95 F 48,000 5,200 2.7 9.2 105 F 38,000 6,200 1.8 6.1 Heating Operation at 120 F Water Ambient Temp Capacity Electrical Heat Pump Heat Pump BTU/hr Power Watts COP EER 45 F 61,500 5000 3.5 12.3 20 F 53,500 5437 2.8 9.8 0 F 47,500 5407 2.5 8.8 65,000 LAHP Heating Performance 7.0 75,000 LAHP Cooling Performance 8 Heating Capacity, BTU/hr 60,000 55,000 50,000 45,000 6.0 5.0 4.0 Water Supply Temp, ºF 110 120 130 Cooling Capacity, BTU/hr 65,000 55,000 45,000 35,000 7 6 5 4 Water Supply Temp, ºF 47 55 42 42 COP 47 COP 55 COP 25,000 3 40,000 35,000 2.0-10 -5 0 5 10 15 20 25 30 35 40 45 50 Outdoor Ambient Temperature, ºF 3.0 Coefficient of Performance 15,000 2 5,000 1 75 80 85 90 95 100 105 Ambient Temperature, ºF Coefficient of Performance 7

SE Standard Features Dual Refrigeration Circuits Simple Piping & Pumping Installation & Service Friendly Easily Zoned 30% Larger Condenser Coil than Traditional Units Self Diagnostic Control Programmable Low Amp Requirements Quiet Operation Soft Start Package Standard Green Hydronic Energy - No Refrigerant in Occupied Space Low Ambient Freeze Protection Sophisticated. but Simple Control Platform Intelligent recovery factory programmed control platform, with state of the art self diagnostic microprocessor allow staging of compressors for seamless operation. Amp draw starts low and stays low with no spike at start-up and use a smaller breaker than other heat pump units for even more efficiency benefits. 8 Specifications Model SCM - 036 COP SCM - 060 COP Heating Capacity 3.95 **44,000 BTUh 13.0 kw **60,000 BTUh 17.0 kw 3.97 Cooling Capacity 10.0 kw 13.5 kw ***34,000 BTUh ***46,000 BTUh Voltage 230v/1ph/60Hz 230v/1ph/60Hz Min Supply Temp 36 F 2.5 C 36 F 2.5 C Max Supply Temp 125 F 52 C 125 F 52 C Min Water Flow 7 gpm 1.60 m3/hr 10 gpm 2.27 m3/hr Max Water Flow 12 gpm 2.75 m3/hr 15 gpm 3.41 m3/hr dp @ Max Flow 21 ft 28 ft 63 kpa 84 kpa Heating Current 13.1 amps 21.3 amps Cooling Current 17.6 amps 26.4 amps Noise Level 56 db(a) 56 db(a) Compressor Scroll x 2 Scroll x 2 Installed Weight 354 lbs 407 lbs 161 Kg 185 Kg ** at 95 F ambient, 47 F supply water (35 C / 12 C) *** at 45 ambient, 115 F supply water

Dimensions SE A B D D1 D2 E F Model Leg height Front to return Cabinet depth Mounting Mounting Bottom lug depth lug centers to return Bottom to supply SCM-036 1 10 17 3 /4 17 3 /8 15 3 /4 5 1 /2 15 1 /4 SCM-060 1 10 17 3 /4 17 3 /8 15 3 /4 5 1 /2 15 1 /4 G H J K W W1 W2 Model Base to bottom edge of lower fan Overall Height Return connection Supply connection Overall width Mounting lug centers Lug center to edge SCM-036 SCM-060 25 53 1 NPT 1 NPT 43 3 /8 27 1 /2 7 15 /16 25 53 1 NPT 1 NPT 43 3 /8 27 1 /2 7 15 /16 Performance 3 Ton Cooling Operation at 47 F Water Ambient Temp Capacity Chiller Chiller Chiller COP BTU/hr Power Watts EER 82 F 38,553 2,523 4.47 15.28 95 F 29,694 3,873 2.25 7.67 105 F 22,880 4,912 1.36 4.66 3 Ton Heating Operation Water Supply Capacity Chiller Ambient Temp Temp. BTU/hr Power Watts Chiller COP 45 F 115 F 35,536 3,855 2.70 32 F 110 F 26,295 3,472 2.22 20 F 105 F 20,245 3,103 1.91 5 Ton Cooling Operation at 47 F Water Ambient Temp Capacity Chiller Chiller Chiller COP BTU/hr Power Watts EER 82 F 61,526 5,150 3.50 11.95 95 F 54,621 5,881 2.72 9.29 105 F 45,668 6,643 2.01 6.87 5 Ton Heating Operation Water Supply Capacity Chiller Ambient Temp Temp. BTU/hr Power Watts Chiller COP 45 F 115 F 60,256 6,919 2.55 32 F 110 F 42,770 5,927 2.11 20 F 105 F 24,769 4,125 1.76 45000 SCM-036 Heating Performance 11 55000 SCM-036 Cooling Performance 11 Heating Capacity, BTU/hr 40000 35000 30000 25000 10 9 8 7 6 Water Supply Temp, ºF 105 110 115 42 COP 47 COP Cooling Capacity, BTU/hr 50000 45000 40000 35000 30000 10 9 8 7 6 Water Supply Temp, ºF 42 47 55 42 COP 47 COP 20000 5 55 COP 25000 5 55 COP 4 20000 4 15000 10000 5000 3 2 1 Coefficient of Performance 15000 10000 5000 3 2 1 Coefficient of Performance 20 25 30 35 40 45 75 80 85 90 95 100 105 Ambient Temperature, ºF Ambient Temperature, ºF 9

HighWall Heating & Cooling HighWall fan coils are the perfect indoor complement to our Solstice heat pumps. HighWall fan coils provide optimum heating and cooling in one classic design. HighWall fan coils are designed for higher volume flow for primary heating in colder climates and use an electronic 3-way valve for reduced energy consumption and increased efficiency. All HighWall fan coils feature high efficiency EC motors with Step-less speed modulation which operate from 50-70% more efficient than traditional on/off motors. Standard Features Quiet Space-Saving Design Heating & Cooling Energy Efficient 3-Way Valve Low Ambient Capable Heat Emitter Hydronic Based No Refrigerant Remote Control Thermostat Auto-Swing Damper for Uniform Air Distribution Easy Installation EC Step-Less Speed Modulation (15% - 100%) 7,400 20,000 BTUh Heating Capacity* 3,200 12,600 BTUh Cooling Capacity** ThinWall Heating & Cooling ThinWall fan coils are the ultra-sleek alternative to HighWall fan coils or can be used in conjunction with them for optimum flexibility. Perfectly conditioned air is quietly distributed through a cross-flow blower configuration with integrated airguiding technology. ThinWall units offer versatility for both heating and cooling while operating up to 30% more efficient than traditional emitters. 10 Units offer custom zoning through integrated intelligent controls which can modulate based on environmental conditions. Standard Features Quiet Modern Space-Saving Design Heating & Cooling Energy Efficient 3-Way Valve Hydronic Based No Refrigerant Remote Control Thermostat (Optional) Cross-Flow Blower Easy Installation Active Carbon Air Filtration 8500 14,600 BTUh Heating Capacity* 1900 3500 BTUh Cooling Capacity** * 122 Supply Water Temp ** 45 Supply Water Temp

ThermaQuiet Heating Only Engineered specifically for low-temperature hydronic applications, ThermaQuiet fan coils are an ideal complement to today's high-efficiency condensing boilers, heat pumps, and solar equipment. This stylish design uses the latest variable-speed fan technology to reduce energy consumption by up to 35% when compared to traditional heating systems, while providing one of the most efficient heat distribution systems on the market. Standard Features Sleek Profile Offers Application Flexibility Compatible with Solar and Heat Pumps "Insta-Heat" Overrides Setting for Immediate "Boost" of Heat Microprocessor Control Platform Cool-Touch Exterior for Safe Operation Diagnostic and Performance LED Indicators Less Expensive than Radiant Flooring 1,400-16,200 BTU/h Solstice BT Hydronic buffer tanks are used as both hydraulic separators and hydronic buffer tanks. As a hydraulic separator, BT's separate the hydronic from the energy source loop (heat pump / boiler) from the hydronic flow in the distribution system (air handlers / emitters). Hydraulic separation is used primarily in systems where flow rates from the source to the distribution vary or with applications utilizing variable speed pumps. The heating or cooling source can be hydraulically decoupled from the distribution system. BT's are used as hydronic buffer tanks in systems having several low BTU cooling or heating loads calling at different times or systems operating below the design load condition. BT's store the additional system volume and energy currently not utilized by the system for use on additional calls for heat leading to more efficient system performance and longer equipment life. All tanks are durable stainless steel construction with R12 insulation and offered in 26 and 40 gallons with optional 3kW electric heating elements. There are four connections (1-1/2 NPT) built into the BT units. Two connections can be piped to the heat pump / boiler, and two connections can be piped to the distribution system. 11

260 North Elm Street Westfield, Ma 01085 (800) 465-8558 Fax (413) 564-5815 www.spacepak.com 7555 Tranmere Drive Mississauga, Ontario L5S 1L4 Canada (905) 670-5888 Fax (905) 670-5782 SHYD-1