CALIBRATION OR VERIFICATION OF MEASURING INSTRUMENTS WHAT NEEDS FOR INDUSTRY?

Similar documents
OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Measuring instruments in industry.

Measuring equipment in a laboratory.

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

Selection and use of ISO 9000

GUIDANCE ILAC-G24 INTERNATIONAL OIML D 10 SERIES Edition 2007 (E) DOCUMENT Edition 2007 (E)

ISO/IEC QUALITY MANUAL

Gravimetric determination of pipette errors

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

Enhanced calibration High quality services from your global instrumentation partner

Checklist. Standard for Medical Laboratory

REFERENTIEL- SODERN. Autre référence / Other reference :

American Association for Laboratory Accreditation

Why System Suitability Tests Are Not a Substitute for Analytical Instrument Qualification

Quality Assurance Manual January 2008 Revision I Revision date of 01/17/13. Pi Tape Corporation. 344 North Vinewood St. Escondido CA USA

(Uncertainty) 2. How uncertain is your uncertainty budget?

Procedure for Equipment Calibration and Maintenance

Regulatory Requirements for Medical Device Calibration Programs

NABL NATIONAL ACCREDITATION

Non-Controlled Copy. Quality Manual Revision Log. Rev # Date Description

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD position paper from SG17 - EN :2009

Quality Assurance System Manual

MINIMUM AUTOMOTIVE QUALITY MANAGEMENT SYSTEM REQUIREMENTS FOR SUB-TIER SUPPLIERS

Check-list for auditors. Audit visit at candidate registered laboratories

UNCONTROLLED COPY FOR REFERENCE ONLY

CALIBRATION PRINCIPLES

Of all the physical properties, it is temperature, which is being measured most often.

Copies of this document shall be classified either as Controlled or Uncontrolled, and shall be identified as such on the cover sheet.

calibrate confidence with Metrology Concepts: Understanding Test Uncertainty Ratio (TUR) Abstract Introduction White Paper

Experience with taximeters with a look at the corresponding tables

QUALITY MANAGEMENT SYSTEM REQUIREMENTS General Requirements. Documentation Requirements. General. Quality Manual. Control of Documents


Length measuring instruments

Quality Management System Policy Manual

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

Quality Management System Manual

Terms and conditions for the invitation by the Danish Emergency Management Agency to submit tenders for a contract concerning the purchase of a mass

Guidelines on the Reporting of Compliance with Specification

Eagle Machining, Inc. Quality Management System

New OIML Document Surveillance of utility meters in service based on sampling inspections

Brown Hills College of Engineering & Technology Machine Design - 1. UNIT 1 D e s i g n P h i l o s o p h y

Row Manufacturing Inc. Quality Manual ISO 9001:2008

RECOMMENDATION. on the Evaluation of Quality Management System of National Metrology Institutes

NIST HANDBOOK 150 CHECKLIST

Recognition of my Product (Testing Laboratory) Why I need recognition, what is the effect?

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

SUPPLIER Form #: 007 AUDIT QUESTIONNAIRE

Quality Management System Manual ISO9001:2008

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

OD-2017-Ed.1.5 CHECK LIST FOR TESTING AND CALIBRATION LABORATORIES

G & R Labs. Quality Assurance Manual. G&R Labs Scott Boulevard Santa Clara CA Light Meters and Calibration

Quality Procedures and Work Instructions Manual

Interpretation of Financial Statements

Space Project Management

Quality Management System

ISO 9001 Quality Systems Manual

QUALITY MANUAL ISO 9001:2015

Forth Engineering (Cumbria) Limited QUALITY MANUAL. Quality Manual Issue 4 Updated April Authorised by: Managing Director.

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

User checks and maintenance of laboratory balances

Concept for an Algorithm Testing and Evaluation Program at NIST

Quality Management System Manual

PUBLICATIONS. Introduction

PRODUCT CERTIFICATION REQUIREMENTS

General Description of The CMC- Services

Keywords: inspection; nuclear material control and accountancy (NMC&A); quality management system

ISO 9001: 2008 Construction Quality Management System Sample - Selected pages (not a complete plan)

and Drug Administration/Office of Regulatory Affairs (FDA/ORA) laboratories.

MAQUET SAS GENERAL TERMS AND CONDITIONS OF PURCHASE

On-site Measurement of Load and No-load Losses of GSU Transformer

Quality Assurance (QA) & Quality Control (QC)

ISO How to Meet. Requirements for Method Verification. Prepared by:

ISO 9001:2008 Quality Management System Requirements (Third Revision)

Guidelines for the Acceptance of Manufacturer's Quality Assurance Systems for Welding Consumables

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

EA IAF/ILAC Guidance. on the Application of ISO/IEC 17020:1998

An Analysis of The Road Not Taken. The Road Not Taken is one of Robert Frost s most famous poems. The

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

MEAT GRADING AND CERTIFICATION BRANCH QUALITY MANUAL

EA Document on. Accreditation. For Notification Purposes

GENERAL WELDING & FABRICATING, INC. 991 Maple Road Elma, New York 14059

ISO 9001:2000 AUDIT CHECKLIST

Generic CMMS Quality Assurance Plan

Measuring Electric Phenomena: the Ammeter and Voltmeter

Quality & Safety Manual

Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1

Preparing for Unannounced Inspections from Notified Bodies

Managing Foreign Exchange Risk with EDC Guarantees

DAVID THOMAS LTD GUIDE TO COMPANY INSOLVENCY

Welcome! Frank Teleso. Quality Manager

Safety and Quality Assurance and Management Systems in Food Industry: An Overview

ISO 9001 (2000) QUALITY MANAGEMENT SYSTEM ASSESSMENT REPORT SUPPLIER/ SUBCONTRACTOR

PROPOSED DOCUMENT. Quality management system Medical devices Nonconformity Grading System for Regulatory Purposes and Information Ex-change

Company Quality Manual Document No. QM Rev 0. 0 John Rickey Initial Release. Controlled Copy Stamp. authorized signature

Measurement and Calibration

Supplier quality guideline. VOSS Automotive Group Issue Rev00

Configuration Management One Bite At A Time

Transcription:

CALIBRATION OR VERIFICATION OF MEASURING INSTRUMENTS WHAT NEEDS FOR INDUSTRY? P. Barbier Collège Métrologie Mouvement Français pour la Qualité 6 allée de la Lyre 33160 Saint Aubin De Medoc, France Abstract: For a long time the terms calibration and verification and verification have often been used as synonyms. Sometimes the difference of meaning is connected with the application in legal metrology or in industry. Today the international Vocabulary of Basic and General Terms in Metrology (second edition 1993) doesn t speak about verification but other standards make its definition clear. In industry what is to be done in the context of Quality assurance implementation? From our point view the user has to choose between calibration and verification in order to demonstrate the traceability to national or international standards. The purpose of this paper is to propose a clear scheme of application in industry taking in consideration a third possibility: the application of Statistical Process Control Techniques in place of or together with calibration or verification. Keywords: Metrology, calibration, verification 1 INTRODUCTION Everybody is always commonly measuring something in everyday life. People measure lengths, weights, speeds, time and they expect the indications of their measuring instruments to be reliable. In industry, for the manufacturing of products as well as for the provision of services, careful measuring is an element of the quality of the manufactured product or of the service provided. To carry out measurements, instruments are used, which no matter how sophisticated and modern they may be, have hall a common drawback: their readings are not constant in time. The causes of this drifting are many and the major one is definitely obsolescence. But there are other reasons: mechanical wear, oxidation, wrong handling A typical example shows that responsible manufacturers are aware of the drift and they can find how large it is. Figure 1 represents the specifications of a multimeter. If can be noted that its accuracy decreases with time and that it will be roughly 3 times less good after one year s operation than after three months. Accuracy: (% of Rdg + Counts) Range 24 Hours 90 Days 1 Year 10 Ω 0.003 + 20 0.005 + 20 0.01 + 20 100 Ω 0.002 + 2 0.003 + 2 0.006 + 2 1 kω 0.002 + 1 0.003 + 1 0.006 + 1 10 kω 0.002 + 1 0.003 + 1 0.006 + 1 100 kω 0.002 + 1 0.003+ 1 0.006 + 1 1 MΩ 0.002 + 1 0.003+ 1 0.006 + 1 10 MΩ 0.01 + 1 0.02 + 1 0.04 + 1 100 MΩ 0.03 + 1 0.05 + 1 0.1 + 1 Figure 1. Evolution of the accuracy of a multimeter Another example can be mentioned. If is about the burettes which are used to measure volumes of liquids. Undeniably this measuring instrument- a bit special drifts more slowly than a multimeter, but there is one question that after it has been used five or ten years glass distortion may occur and the graduations may be altered, thus producing erroneous measurements.

2 MEASUREMENT AND QUALITY OF INDUSTRIAL PRODUCTS Measurements, in industry, are carried out at the four stages of the elaboration of a product: - Beforehand, at the stage of research often linked to applied research in a laboratory. - When prototypes are tested or the qualification of products is tested. - When the products are manufactured. - When these products are verified. At these different stages, the operator has to be able to rely on the reading of the measuring instrument, he has to have evidence that instrument has not drifted beyond some limits. The must, in other words, be in a position to show that the traceability of the measurement to national standards is complied with. What does this person need not to remain in doubt? The language of the metrologists of the various countries makes use of the following terms: - Calibration - Verification - Confirmation - Validation - Qualification. For some authors, these different terms are equivalent, or more exactly each one of these terms is used indifferently to describe the fact there is traceability to national standards. This confusion, or lack of clarity, has been going on for time, at least some thirty years, probably more. During this period, the International Vocabulary of Metrology was published by ISO, it has the advantage of giving a clear definition of the word calibration, but it doesn t mention the other terms (verification, confirmation ). Let us then try to analyse the definitions of each term, when they exist, and attempt to draw a conclusion about the real needs for industry, the one and only aim being to make sure of the quality of measurements to guarantee the quality of products. 3 CALIBRATION This is the definition from the V.I.M: Set of operation that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system, or values represented by a material measure or a reference material, and the corresponding values realized by standards. 1. The result of a calibration permits either the assignment of values of measurands to the indications or the determination of corrections with respect to indications. 2. A calibration may also determine other metrological properties such as the effect of influence quantities. 3. The result of a calibration may be recorded in a document, sometimes called a calibration certificate or a calibration report. Therefore - a calibrated operation does not entail any conclusion of conformity or non-conformity to a specification - a calibrated instrument, even if its deviation from the standard is big, can be used on condition a correction is applied. - a calibrated instrument cannot be used without its calibration certificate. It goes without saying that a metrology laboratory which makes measurements for which each influencing parameter is important to reduce the ultimate measurement uncertainty will use calibrated references which by the way are called standards. On the other hand in a workshop where the major influencing factor will be temperature for instance, the operator will only need to rely on his measuring instrument, then to know whether it is good or bad. Hence the notions of verification, confirmation, validation 4 VERIFICATION Three definitions taken from two ISO documents and an American norm deserve full quotation. ISO 8402 Quality management and quality assurance vocabulary. Verification: Confirmation by examination and provision of objective evidence that specified requirements have bee fulfilled. 1. In design and development, verification concerns the process of examining the result of a given activity to determine conformity with the stated requirements for that activity.. 2. The term verified is used to designate the corresponding status.

ISO Guide 25 general requirements for the competence of calibration and testing laboratories. Verification: confirmation by examination and provision of evidence that specified requirements have been met. NOTE - In connection with the management of measuring equipment, verification provides a means for checking that the deviations between values indicated by a measuring instrument and corresponding known values of a measured quantity are consistently smaller than the maximum allowable error defined in a standard, regulation or specification peculiar to the management of the measuring equipment. - The result of verification leads to a decision either to restore to service, or to perform adjustments, or to repair, or to downgrade, or to declare obsolete. In all cases it is required that a written trace of the verification performed be kept on the measuring instrument s individual record. ANSI/NCSL 2540-1 1994 American National Standard for Calibration. Calibration Laboratories and measuring and test equipment. General requirements. Verification: Evidence by calibration that specified requirements have been met.. 1 and 2..identical to the note of ISO guide 25 3. The term verification as defined in this standard is frequently referred to as calibration in the United States. The first two definitions are very close, the one of ISO guide 25 has the advantage to be specific to measuring equipment. On the contrary, the American definition reveals that in the United States the amalgam calibration verification is solid and that the norm is likely to maintain the confusion for a long time! Then if we consider the definition of ISO guide 25 verification permits to decide whether a measuring instrument satisfies its specifications, if it does not it should be either repaired or corrected, or downgraded, or even decommissioned. It must be noted that in the definition of ISO guide 25 the word calibration is not used. This means that you can verify a measuring instrument without calibrating it. This seems obvious, but unfortunately this evidence is not accepted in every country. 5 METROLOGICAL CONFIRMATION Only one document defines the term confirmation, it is Project ISO 10012 (CD1). Its title is Measurement Control System and the definition is: - Set of operations required to ensure that an item of measuring equipment is in a state of compliance with the requirements for intended use. 1. Metrological confirmation normally includes calibration and/or verification, any necessary adjustment or repair, and subsequent recalibration, comparison with the metrological requirements for the intended use of the equipment as well as any required sealing and labeling. 2. Metrological confirmation is not achieved until and unless the fitness of the measuring equipment for the intended use has been demonstrated and documented. 3. The requirements for intended use may include such considerations as range, resolution, maximum permissible errors, etc. 4. Metrological confirmation requirements are usually distinct from and are not specified in product quality requirements. 5. A diagram of the processes involved in metrological confirmation is given. 6. For brevity in ISO 10012, this term may be referred to as confirmation A new element is introduced, it is the notion of intended use. Is the measuring instrument, either verified or calibrated, fit to do the job the user wants it to do or, more precisely, is it reliable to make the measurement intended? For instance, is the uncertainty provided by the instrument sufficient with the measurement margins compared? Figure 2 Simply illustrates the difference between the two notions of calibration and verification. This diagram was first published in the French norm NFX 07010 entitled The metrological function in the firm, it has been taken up again and supplemented in the revision draft of norm ISO 10012-1 in a slightly different form, introducing the notion of metrological confirmation. This latter version has not been published.

VERIFICATION OR CALIBRATION M.T.E. STANDARD TECHNICAL COMPARISON RESULTS COMPARISON TO THE DOCUMENTED REQUIREMENTS BAD GOOD Corrective action Removal service Downgrading Information and appropriate action on products VERIFICATION LABELLING Or / and VERIFICATION DOCUMENT CALIBRATION LABELLING and CALIBRATION CERTIFICATE METROLOGICAL SHEET UPDATING RETURN TO THE USER The M.T.E. may be used without any significant risk Either : The result are used by the to improve the measurement process. Or : The user decides whether or not the M.T.E. by used Figure 22. Verification and and Calibration calibration 6 QUALIFICATION, VALIDATION These terms which are sometimes used are defined in norm ISO 8402. To my mind, they are synonyms of verification in metrological language; validation is close to confirmation as it brings in the notion of distinctive specifications for a specific use.

7 CONTROL OF MEASUREMENT PROCESSES Another concept developed in norm ISO 10012-2 entitled Control of measurement processes. If is based on the SPC (Statistical Process Control) type supervision principle; it consists in regular controls of the measuring equipment over short periods (once a day or once a week for instance) using a check standard. Keeping track of the evolution of the result, within upper and lower limits, makes it possible to undertake either a correcting action or a repair of the measuring instrument. (Figure 3) Upper limit T1 T2 T3 T4 Figure 3. Interesting result are obtained by this method for laboratory scales or three dimensional measuring machines, for instance. 8 WHAT NEEDS FOR INDUSTRY After over 30 years of experience, watching the metrology problems which rise in industry, there are good reasons to believe it is advisable to minutely analyse the requirements before deciding what is the best solution to ensure the quality of the measurements made. A choice has to be made between four possible solutions - Calibration - Verification - Confirmation - Control of measurement processes Calibration - for the firm s standards and the transfer standards used as references. Verification - for most measuring instruments that the user needs to know they are reliable, regardless of the specifications of the measurement to carry out. Confirmation - for the measuring instruments used to make measurements allowing a margin, when the ratio between margin and measurement uncertainty is low, lower than 4 or 3, for example. Control of measurement processes every time it can be done and the user is motivated, trained and takes part in the follow up of result. A possible division of the different cases in a firm manufacturing aeronautical materials is a follows : 3% calibration 2% metrological confirmation 4% control of measurement processes 93% verification. 9 CONCLUSION There is still a long way to go before the concepts exposed in this paper are accepted by metrologists all over the world. The different cultures, the countries economic past, custom, the practices of legal metrology cause that the different notions mentioned are not accepted by all. It is unquestionably the role of normalization organization, ISO especially, to attempt to make clear these various concepts, with the purpose of improving the quality of measurements and lowering the costs of metrology. Work is being done in this direction by the TC 176 of ISO. It is to be wished that it will soon show results, and particularly that the documents produced will be clear for everybody. AUTHOR: P. BARBIER, Collège Métrologie, Mouvement Français pour la Qualité, 6 allée de la Lyre, 33160 Saint Aubin De Medoc, France