PRODUCT DATA SHEET Sikafloor -81 EpoCem

Similar documents
3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

2-part Epoxy primer, levelling mortar and intermediate layer

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

PRODUCT DATA SHEET Sika Cable System

2-part epoxy textured roller and seal coat

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Low viscosity, solvent free elastic adhesive for wood flooring

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

High-performance, 2-part epoxy anchoring adhesive

Wecryl Waterproofing System under surfacing supplied by others

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Tecnoepo Flooring System 185

WATERPROOFING OF WET ROOMS

weber.floor 4660 Marine Elastic (EN)

Sikagard -203 W (Steridex)

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

GigaCrete Specification PlasterMax

Concrete Repair. Applications and Procedures

PRODUCT DESCRIPTION 29/08/2014

Minor Cracks in Horizontal Surfaces

SC2000 CEMENT BONDING PROCEDURES

Division 9. SignaFlor Pad and Pour Flooring System

CA-48 TECHNICAL SPECIFICATION

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

WATERPROOFING FOR CONCRETE STRUCTURES

SECTION RESURFACING CAST IN PLACE CONCRETE

TECHNICAL DATA SHEET. TOPECA, Lda Rua do Mosqueiro Cercal Ourém PORTUGAL. Tel.: Fax.:

SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM

DECLARATION OF PERFORMANCE

BLACK JACK ALL WEATHER ROOF COATING

Epoxy Floor Coating Problem Solving Guide

Mold Preventing I nterior System

Solvent Cementing Instructions For Plastic Pipe & Fittings

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

BENTLEY ELEMENTS COLLECTION LVT

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Black epoxy paste adhesive system

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Document Library TS Data Sheet

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

Construction. Use. Planning. Construction. Product. Environment. Safety. Service. Sika Technology and Concepts for Industrial Flooring

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

SECTION POLISHED CONCRETE FINISHING

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Resurfacing Concrete. Page 1 of 5

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Construction. Sika -1 Waterproofing System. Waterproofing Above and Below Ground for both New and Refurbishment Works

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

12 POLYURETHANE ADHESIVE (PU 105)

Mineral waterproof coating PCI Dichtschlämme

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Ultracolor CG2. Fast setting and drying grout for 2 to 20 mm joints, available in 26 colours; does not produce efflorescence

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

(T indicates a Tropicalised version with extended workability. No change has been made to the formulation)

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

Document Library TS Data Sheet M Windo-Weld Super Fast Urethane. Data Sheet. Public

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

USER GUIDE Easier, Safer, Betta! WATERPROOFING

Mapei systems for radiating floor heating with high thermal efficiency

WOOD FLOORING ADHESIVES

G4 is browny translucent in colour and is effected by UV light. Therefore it is for internal use unless top coated to protect it from UV light

RECOATING AND RENEWING SPF ROOFING SYSTEMS

RESTORATION + DECORATION OF BALCONIES AND TERRACES. Decorative, Easy to Maintain and Slip-Resistant Surfaces

Care and Maintenance for Wood Flooring

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

RAPTOR TRUCK BED LINER - BLACK

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

Sikaflex Sealant Installation. Sika Corporation

flooring sin materiali protettivi milano

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

RTV162. Electronic Grade Silicone Adhesive Sealant

Colorado State University. Durrell Center Roof Repair

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

10P20-44 High Solids Epoxy Primer

Retail Price List 2015

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

How To Test A Base Axe

Vinyl Composition Tile Installation System

LATICRETE 290 Premium Floor and Wall Thin-set Adhesive PRODUCT DESCRIPTION

Two component epoxy paste adhesive

Transcription:

3- PART CEMENT AND EPOXY COMBINATION MORTAR FOR SELF- SMOOTHING FLOOR SCREEDS OF 1.5 TO 3 MM DESCRIPTION New HC is a three part, epoxy modified cementitious, fine textured mortar for self smoothing floor screeds in thin layers of 1.5 to 3 mm. USES As a Temporary Moisture Barrier (min. 2 mm thick) allowing the application of Epoxy, Polyurethane and resin floors requiring dry substrates, over high moisture content substrates, even green concrete, for a lasting solution. As a self-smoothing screed for: Levelling or patching horizontal concrete surfaces, in new work or repairs, in aggressive chemical environments Floor topping on non ventilated damp substrates without particular aesthetic requirements Levelling layer under Epoxy and Polyurethane floor coatings / screeds, tiles, sheet floors, carpets or wooden floors Repair and maintenance of monolithic and vacuum concrete floors Extended with quartz sand, as a patching and repair mortar: Under Epoxy and Polyurethane floor coatings / screeds Designed for use on cementitious substrates. CHARACTERISTICS / ADVANTAGES Simple application system Prevents osmotic blistering of resin based coatings over damp substrates Can be overcoated with epoxy resin compounds after 24 hours (20 C, 75 % r.h.) Economical in use and easy to install Good leveling properties Impervious to liquids but permeable to water vapour Frost and de-icing salt resistant Thermal expansion properties similar to concrete Excellent adhesion to damp and green concrete Excellent early and final mechanical strengths Excellent resistance to water and oil Will not corrode reinforcement Pre-dosed sets For internal or external use Contains no solvents 1 / 6

PRODUCT INFORMATION Chemical Base Packaging Epoxy modified cementitious mortar. Pre-batched 23 kg units. Part A 1.14 kg plastic container Part B 2.86 kg plastic container Part C 19.00 kg plastic or aluminium lined double paper bags Appearance / Colour Part A-resin: white liquid Part B - hardener transparent yellow liquid Part C - filler: natural grey aggregate powder Colour: light grey Finish Colour: Matt grey Shelf Life Part A, part B: 12 months Part C: 9 moths Storage Conditions The product must be stored in original, unopened and undamaged sealed packaging, in dry conditions at temperatures between +18 C and +30 C. Part C: Protect from humidity Density Part A ~ 1.05 kg/l (at +20 C) Part B ~ 1.03 kg/l (at +20 C) Part C ~ 1.72 kg/l (at +20 C) Mixed A+B+C: ~ 2.10 kg/l (at +20 C) (EN 1015-6) TECHNICAL INFORMATION Compressive Strength (+27 o C / 75 % r.h.) 1 day ~15 N/mm 2 7 days ~38 N/mm 2 28 days ~44 N/mm 2 Tensile Strength in Flexure ~10 N/mm 2 (at 28 days, +27 o C) (EN 13892-2) Pull of Strength 1 days Not measurable 7 days > 1.5 N/mm² (concrete failure) 28 days > 1.5 N/mm² (concrete failure) E-Module Static +20 o C ~20 000 N/mm 2 (at 28 days, 23 o C) Coefficient of Thermal Expansion Chemical Resistance ά ~15.10-6 m/m C The Sikafloor EpoCem product range has improved chemical resistance over plain concrete in aggressive environments, but is not designed as a chemical protection. For specific chemical resistance, always overcoat with a suitable product from the Sikafloor and Sikagard range. For occasional exposure or spillages, consult technical department. 2 / 5

SYSTEM INFORMATION Systems The system configuration as described must be fully complied with and may not be changed. Primer indicated below is suitable for each of these substrates: Green concrete (as soon as mechanical preparation is possible) Damp concrete (> 14 days old) Damp aged concrete (rising moisture) APPLICATION INFORMATION Mixing Ratio Consumption Layer Thickness Ambient Air Temperature Relative Air Humidity Substrate Temperature Substrate Moisture Content Dew Point Pot Life Part A : part B : part C - packing size : 1.14 : 2.86 : 19 kg Primer Sikafloor -155 WN (parts A+B), thinned with 10% water, ~ 0.3-0.5 kg/m 2 dependent on the substrate conditions, when repairing monolithic or vacuum concrete, or without a broadcast finish or when Sikafloor -81 EpoCem is over coated with itself. Self smoothing screed: New HC ~2.25 kg/m 2 /mm ~4.5 kg/ m2 for a 2 mm thick application (minimum for T.M.B) Extended mortar mix New HC ~ 2.4 kg/m2/mm These figures are theoretical and do not allow for any additional material due to surface porosity, surface profile, variations in level or wastage, etc 1.5 mm min. / 3.0 mm max. If New HC is used as a Temporary Moisture Barrier (TMB), a minimum of 2 mm must be applied. +8 C min. / +30 C max. 20% min. / 80% max. +8 C min. / +30 C max. Can be applied on green or damp concrete, without any standing water. Although the product can be applied onto green concrete surfaces (> 24 hours), it is advised to allow at least 3 days for early shrinkage of concrete to occur in order to prevent concrete shrinkage cracks from appearing on the screed surface. Beware of condensation! The substrate and uncured floor temperature must be at least 3 C above the dew point to reduce the risk of condensation or blooming on the floor finish. ~20 minutes ( 23 kg) Reactivity (75% r.h.): 30 o C Waiting Times Can be walked on after: ~15 hours Light mechanical loading after: 2 days Fully cured after: 7 days Can be overcoated with epoxy based materials as soon as surface 1 days moisture content of EpoCem is less than 4%, however not earlier than: 3 / 5

APPLICATION INSTRUCTIONS SUBSTRATE QUALITY / PRE-TREATMENT The concrete substrate must be sound and of sufficient compressive strength (minimum 25 N/mm 2 ) with a minimum pull off strength of 1.5 N/mm 2. The substrate can be damp but must be free of standing water and free of all contaminants such as oil, grease, coatings and surface treatments etc. If in doubt, apply a test area first. holes and voids must be fully exposed. SUBSTRATE PREPARATION Concrete substrates must be prepared mechanically using abrasive blast cleaning or scarifying equipment to remove cement laitance and achieve an open textured surface. Weak concrete must be removed and surface defects such as blow holes and voids must be fully exposed. Repairs to the substrate, filling of blowholes/ voids and surface levelling must be carried out using appro-priate products from the Sikafloor, SikaDur and Sikagard range of materials. High spots can be removed by grinding. All dust, loose and friable material must be complete-ly removed from all surfaces before application of the product, preferably by brush or vacuum. MIXING Flooring Screed: At temperatures between +12 o C to +25 o C: 1 : 2.5 : 17 (by weight) Parts (A+B) : C = 4 kg : 19 kg At temperatures between +8 o C to +12 o C and +25 o C to +30 o C: The amount of Part C can be reduced to 18 kg in order to improve workability. Please note: Never reduce Part C by more than this amount. 1 : 2.5 : 15.8 (by weight) Parts (A+B) : C = 4 kg : 18 kg Extended mortar mix. Repair mortar: To repair surface irregularities and holes 3 to 5 cm in diameter and deeper than 3 mm and up to 9 mm the standard mix can be ex- tended with dry quartz sand. * Please contact Technical Department for details. For this application, to achieve a good bond of the mortar to the substrate, SikaTop -Armatec -110 EpoCem must be used as bonding bridge. Apply the mortar wet on wet to the primer. MIXING TIME Prior to mixing, shake part A (white liquid) briefly until homogenous, then pour into container of part B and shake vigorously again for at least 30 seconds. When dosing out of drums, stir and homogenise first. Pour the mixed binder mixture (A+B) into a suitable mixing container (capacity of about 30 litres) and gradually add part C to the mixer while stirring with a power mixer. Mix thoroughly for 3 minutes until a uniform mix has been achieved with no lumps. Mix only full units of A+B+C components. Do not mix smaller amounts. Do not add water. When dosing with additional aggregates, add them after adding part C to the mix. Mix thoroughly for 3 minutes until a uniform mix has been achieved. MIXING TOOLS Mix using a slow speed electric mixer (300-400 rpm) with helical paddle or other suitable equipment. For mixing 2 3 bags at once, single or counter rotating double mortar (basket type) and forced action (pan type) mixers are also recommended. Free fall mixers must not be used. APPLICATION Place mixed New HC onto the primed substrate and spread evenly to the required thickness uniformly with a rubber or metal trowel or spatula and immediately roll with a spike roller to remove entrapped air and obtain an even thickness layer. Workability can be adjusted by varying slightly the amount of part C. See Mixing above. Do not use additional water, which would disturb the surface finish and cause discolouration. A seamless finish can be achieved if a wet edge is maintained during application. CLEANING OF TOOLS Clean all tools and application equipment with water immediately after use. Hardened / cured material can only be removed mechanically. MAINTENANCE Due to the texture of its surface, Sikafloor -81 Epo- Cem is not suitable to be used as wearing layer where easy staining can occur. A seal coat of the Sikafloor range with suitable cleaning capabilities is advisable. Remove dirt using a brush and/or vacuum. Do not use wet cleaning methods until the product is fully cured. Do not use abrasive methods or cleaners. 4 / 5

FURTHER DOCUMENTS Substrate quality & Preparation Please refer to Sika Method Statement: EVALUATION AND PREPARATION OF SURFACES FOR FLOORING SYS- TEMS. Application instructions Please refer to Sika Method Statement: MIXING & AP- PLICATION OF FLOORING SYSTEMS. LIMITATIONS If New HC is used as TMB (Temporary Moisture Barrier), a layer of a minimum 2 mm thick must be applied. (~ 4.5 kg/m 2 ) Always ensure good ventilation when using Sikafloor - 81 EpoCem New HC in a confined space to remove excess moisture. Freshly applied New HC must be protected from damp, condensation and water for at least 24 hours. Prevent premature drying by protecting from strong wind and do not expose to direct sun light while fresh. Apply primer and New HC on a falling temperature. If applied during rising temperatures pin holing can occur. Applications under extreme conditions (high temperature and low humidity) which can cause fast drying of the product must be avoided as the product does not allow the use of curing compounds. Under no circumstances add water to the mix. Non moving construction joints require pre-treatment with a stripe of primer and New HC. Treat as follows: Static Cracks: Prefill and level with SikaDur or Sikafloor epoxy resin. Dynamic Cracks (> 0.4mm): To be assessed on site and if necessary apply a stripe coat of elastomeric material or design as a movement joint. The incorrect assessment and treatment of cracks can lead to a reduced service life and reflective cracking. Colour variations can occur on unsealed Sikafloor -81 EpoCem New HC through exposure to direct sun light. This however, will not adversely influence the mechanical properties. The TMB effect in Sikafloor -EpoCem New HC is limited in time, without additional preparation. Always verify the surface moisture content if more than 5-7 days have passed since application. BASIS OF PRODUCT DATA All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. LOCAL RESTRICTIONS Please note that as a result of specific local regula- tions the declared data for this product may vary from country to country. Please consult the local Product Data Sheet for the exact product data. ECOLOGY, HEALTH AND SAFETY For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Safety Data Sheet (SDS) containing physical, ecological, toxicological and other safety-related data. LEGAL NOTES The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika re- serves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. 5 / 5