Air Conditioning Laboratory Unit A660

Similar documents
P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Incubator with mechanical convection

Refrigeration Compressed Air Dryer Buran Ultrapulse

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Climate Test Chamber. System Weiss. Type WK3-2000/40

CRAC Precision climate control units for data centres

Test equipment for temperature and its reduction

Heat Transfer Service Unit H112

Climate chamber with illumination

Material test chamber with mechanical convection

Heating oven with mechanical convection

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

OT 40L / 90L. Laboratory Steam Sterilizers


Heating oven with mechanical control

GenStore Archive Cabinet

Hand-held thermometer Model CTH7000

ECOCIAT. Domestic hot water heat recovery unit

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Vacuum drying oven for non-flammable solvents

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Chilled Water Precision Air Conditioner For Critical Application

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Solenoid valves Type EVU

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

USB-500 Series Stand-Alone, Low-Cost Data Loggers

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CYMAQ Marking System AS200 + DS7050 N-14

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

CE6500 Energy Recovery Ventilator

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

USB-500 Series Low-Cost Data Loggers and Accessories

IV. Rear Mount System

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

جامعة البلقاء التطبيقية

The most comfortable air-conditioning systems for yachts and superyachts

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Environment-Laboratory Ambient Conditions

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

NMC Pro System Manager

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Thermostatic valve Type AVTA

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Adsorption air dryers ADS 1 215

GTS PRODUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. Gas-to-Steam Humidification System

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Air Conditioning Sign-Off Sheet

A/C refrigerant system, overview

Defining Quality. Building Comfort. Precision. Air Conditioning

Top Technology for Industry, Agriculture, Business and Communities

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Building Services Engineering Technician

How is Dew Point Measured Reliably?

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Technical Guide. Thermostats Air Conditioning

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

Photovoltaic Solar Energy Unit EESFB

, User s Manual

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

USB-500/600 Series Low-Cost Data Loggers and Accessories

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Combi Unit Genius. The energy efficient Building Service Centre

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Assisted lift operated 2/2-way solenoid valves Type EV250B

Laboratory Autoclave SN210/310/510,SQ510/810

KNC Model 3666 Automatic Pressure Calibration System

Air-conditioning and climate-control technology

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

AIR-CONDITIONER SPLIT TYPE

QuickSpecs. HP IP Console Switch with Virtual Media Overview

ThermoStar Refrigeration Air Dryers

On-line Machine Condition Monitoring [The CMS System]

HP Server Console Switch with Virtual Media Overview

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Simplify Data Acquisition with a Built-in LXI Web Server

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Electronic Control Devices The European Product Catalogue 2007

Series 8146/5-V37 and Series 8150/5-V37

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

VSO MAX HP High Flow Proportional Valve

Mitos P-Pump. product datasheet

QuickSpecs. HP IP Console Switches. Overview

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Direct steam injection humidifiers

STERILIZERS, LABORATORY DRYING OVENS

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

heat treatment equipment & accessories

Transcription:

Air Conditioning Laboratory Unit A660 Figure 1: A660 Base Unit shown with optional extra A661B fitted High accuracy wet and dry bulb sensors before and after each process to determine air condition. All processes fully instrumented to allow energy and mass balances across each process of heating cooling and humidity change. Reaches stability rapidly after a change of operating conditions. May be upgraded at any time to reduce capital outlay. Upgrade options available include: 1. Digital Temperature, 2. Re-circulation, 3. Computer linking (with software), 4. PID control and Environmental Chamber. Two year Warranty. Page 1

Figure 2: A660 with All Upgrade Options Introduction The range of temperature, humidity and air movement which the majority of individuals regard as comfortable is extremely narrow. It is therefore increasingly common for close controlled air conditioning to be applied to new and refurbished buildings and transport facilities. This increasing use of air conditioning, if not carefully designed, installed and maintained could be a major contributor to the causes of global warming. Therefore student engineers training for careers involved in the design, operation or servicing of air conditioning plant must be completely familiar with the processes occurring between air inlet and its discharge to the conditioned space. The Hilton Air Conditioning Laboratory Unit A660 is an expandable teaching and experimental unit that enables students to investigate the basic air conditioning processes of heating, cooling, humidification, dehumidification and air movement that are of fundamental importance to undergraduate engineers. The addition of optional upgrades, which may be added at any stage in the units extensive life, allow students to investigate air re-circulation and mixing, computer monitoring, dynamic humidity and temperature control and the environmental control of a test chamber. The unit is applicable for the teaching of students in: Refrigeration and air conditioning Building services Mechanical Engineering Marine engineering Plant and process engineering Food processing Chemical engineering Mining engineering Control engineering Air conditioning laboratory Unit A660 Demonstration of the processes and components used in heating, cooling, humidification, dehumidification of an airstream. Measurement of air psychrometric condition before and after humidification, heating, de-humidification / cooling using pairs of precision wet and dry bulb sensors. Determination of a heat and mass balance across each process resulting in heating, cooling and humidity change using the instrumentation fitted. Construction of a complete refrigeration cycle diagram for the air-cooling plant plus an energy balance between the refrigeration circuit and the change in air enthalpy and its mass flow across the evaporator. Investigation of the volumetirc efficiency of the refrigeration compressor under varying load. Determination of the specific heat capacity of air, by measurement of the change in psychrometric condition across a heating or cooling process. Page 2

Description A complete, upgradeable, instrumented air conditioning laboratory unit mounted on a steel frame and castor wheels. Upgrades may be added at any stage in the unit s long life to spread the investment costs. The base unit comprises a variable speed radial acting axial flow fan discharging into a 250mm square duct with steam humidifier, electrical pre-heaters, direct expansion cooling coil/de-humidifier, electrical reheaters and orifice plate for airflow measurement. Aircooling is provided by vapour compression refrigeration system with pressure, temperature and refrigerant flow measurement. This allows the construction of a full cycle diagram and the balancing of refrigerant system energy balance against the airside energy transfer. Air condition is recorded before and after each process using precision wet and dry bulb thermometers. Instrumentation allows the electrical power to each resistive load to be measured and balanced against the air enthalpy change and mass flow. An upgradeable fully instrumented air conditioning laboratory unit incorporating steam humidification, direct expansion refrigeration cooling and de-humidification, reheating, variable speed radial acting axial flow fan and airflow measurement. All parts in corrosion proof plastic, stainless steel, galvanised steel, brass or copper. Psychrometric condition measured before and after each process by high precision wet and dry bulb sensors with 0 to 100% RH measurement capability. Airflow is adjustable to at least 0.14m3/s with switchable heating up to 4kW and switchable steam injection up to 5kW electrical equivalent. Cooling is by a fully instrumented vapour compression cycle with nominally 2kW capacity. Optional upgrade paths include: Digital Temperature Upgrade Recirculating Duct Upgrade PID Control Upgrade Environmental Chamber Upgrade Computer Linked Upgrade A661A A661B A660C A660D AC661A Supplied with a detailed experimental operating and maintenance manual giving example experimental results and sample calculations. Accessories and spares for two years normal operation together with a full two-year warranty. Dimensions Height 126cm Depth 53cm Width 237cm Weight: 165kg Width 363cm with addition of A661B Recirculating duct Weight 224 kg with addition of A661B Recirculating duct Services Required Electrical: A: 380/415V, 3 Phase, 50Hz 5 wire system comprising 3 phase, neutral and earth. Line current up to 20A per phase. B: 208/220V, 3 Phase, 50 or 60Hz. 4 wire system comprising 3 phases and earth. Line current up to 32 Amps per phase. Clean water: Up to 10 litres per hour at a minimum 2m head. May be mains or tank source. Order as: A660 Air Conditioning Laboratory Unit Electrical Either: A: 380/415V, 3 Phase, 50Hz 3 phase, neutral and earth. Or B: 208/220V, 3 Phase, 50 or 60Hz. 3 phase and earth. Language Either: English, Spanish or French Shipping s A660 Base unit only without optional upgrades: Net Weight (approx.) 165 kg Gross Weight (approx.) 226 kg Packing Case Volume (approx.) 1.57 m3 Packing Case Dimensions (approx.): 165 x 65 x 146 cm Accessories and Spares Unit supplied with: One experimental operating and maintenance manual in English, Spanish, French. Accessories and spares for 2 years normal operation. List available on request. Also Available On Request Further detailed specification. Additional copies of instruction manual. Recommended list of spares for 5 years operation. Page 3

Optional Extra A661A Digital Temperature Upgrade Optional Extra A661B Recirculating Duct Upgrade Allows the proportion of recirculated air to be varied and its effect upon the energy requirements for air conditioning to be investigated. Additional psychrometric measuring points supplied allow the enthalpy of two-mixed streams to be investigated. Allows all of the above experiments with all temperatures displayed on a single switched digital temperature indicator to 0.1 C resolution. Order as: Digital Temperature Upgrade A661A Investigation of the effects of air recirculation proportion on the energy requirement of the air conditioning process. Investigation of the enthalpy of mixing of two airstreams. Order as: Recirculating Duct Upgrade A661B Shipping A661B option only: Net Weight (approx.) 59 kg Gross Weight (approx.) 148 kg Packing Case Volume (approx.) 1.67 m 3 Packing Case Dimensions (approx.) 203 x 107 x 77 cm Page 4

Optional Extra A660C PID Control Upgrade Note: the A660C must be preceded by the A661B. Allows investigation of the individual and combined effects of Proportional, Integral and Derivative control of temperature and humidity and the components that are required for the process. Additional software allows the process to be computer controlled and monitored as in a Building Energy Management System. Investigation of proportional, integral and derivative (PID) control of humidity and temperature in the Recirculated air. Investigation of computer control of two PID controllers and the system response time. Order as: PID Control Upgrade A660C Optional Extra A660D Environmental Chamber Upgrade Note: the A660D must be preceded by the A661B. A 1m 3 environmental chamber which adds considerable realism to the air conditioning process by providing a significant volume that may be heated cooled and humidified either under manual control or by PID control with the addition of the A660C upgrade. Investigation of humidity and temperature in an enclosed test chamber. Investigation of the effect of temperature and humidity on materials and substances. Order as: Environmental Chamber Upgrade A660D Page 5

Optional Extra AC661A Data Acquisition Upgrade Note: The AC661A must be preceded by the A661A. Hardware details The Optional Computerised Data Acquisition Upgrade AC661A consists of a 21 channel Hilton Data logger (D103), together with pre-configured, ready to use, Windows TM compatible educational software. Factory fitted coupling points on the A660 allow installation of the upgrade to the unit at any time in the machine s extensive life. The Hilton Data logger (D103) connects, using the cable supplied, to a standard USB port on the user-supplied PC. If more than one logger is required connection is via a second USB port or standard USB hub. The combined educational software and hardware package allows immediate computer monitoring and display of all relevant parameters on the A660. Software Details The pre-configured menu driven Software supplied with the Computer Upgrade AC661A allows all recommended experiments involving the electronic transducers and instruments on the A660 to be carried out with the aid of computerised data acquisition, data storage and on-screen data presentation. This enhances student interest and speeds comprehension of the principles being demonstrated. Students are presented with either raw data for later hand calculation or alternatively data may be transferred to most spreadsheets for computerised calculation and graphical presentation. Data may be stored on disc and displayed at any time using the software supplied. Alternatively data may be transferred to any compatible spreadsheet together with individual time and date stamp on each reading for complex analysis. Additional Data Logging Facility Supplied As Standard The D103 is the third generation of Hilton Data Logger. It comprises an industrially proven 21 channel interface with 8 thermocouples (type T and K as standard) / differential voltage inputs (±100mv DC), 8 single ended DC voltage inputs (±8v), 4 logic or frequency inputs and one mains voltage input. In addition there are on board 12v DC, ±5V DC and ±15v DC power supplies for most commercially available transducers. The Hilton Data Logging software supplied as standard with the AC661A package allows the D103 to be disconnected from the A660 and used together with most standard transducers as a stand-alone computer data logger for the instrumentation and monitoring of existing laboratory equipment using locally sourced industrial transducers. The software is also backwards compatible with our many second generation D102 data loggers that are already in use worldwide. Full data logger command protocol and communications details are provided in an extensive user manual that allows other software applications to communicate with the logger via the USB interface. Users can write their own software, typically in LabView, Matlab, C, C++, Visual Basic etc. This further expands the student project capabilities of the AC661A package from teaching and demonstration into the field of research and postgraduate study. New for 2013: p-h software also available. Contact a sales representative for more details Computer Hardware Requirements The menu driven Software supplied with the Computer Upgrade AC661A will operate on a PC which has at least 0.5Gb Mb ram, VGA graphics, 1Gb hard drive, CD drive and an available USB port. The software is Windows 2000, XP and 7 compatible. Order as: Data Acquisition Upgrade AC661A P.A.HILTON Ltd. Horsebridge Mill, King s Somborne, Stockbridge, Hampshire, SO20 6PX, England. Telephone: National (01794) 388382 International +44 1794 388382 Fax: National (01794) 388129 International +44 1794 388129 E-mail: Website: sales@p-a-hilton.co.uk www.p-a-hilton.co.uk Page 6