Wall Lining Systems Wall liner

Similar documents
Partitioning & Ceiling Product Information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

PART 1 GENERAL 1.1 SECTION INCLUDES

Energy Company Obligation (ECO): Technical Monitoring Questions

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

12.1 Schlüter -KERDI-BOARD

Manual lifting and handling

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Guidelines for Earthquake Bracing of Residential Water Heaters

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

FireWall. High performance fireresistant. FireWall.

Module 3.7. Thermal bridging

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Guidelines for Earthquake Bracing Residential Water Heaters

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Composite Panel Firewall Systems

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Sports Buildings: budget costs for the Flood Relief Fund

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP)

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

plumbing products guide

Technical Data Sheet W13. Edition Knauf Fire Walls

Internal wall insulation in existing housing

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Rockwool Flexi Insulation Application Guide

PB301 July Lightweight Building Solutions. Bushfire Protection.

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

PANELIZED HOME INSTALLATION GUIDELINE

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

CertainTeed. Shaftliner For A rea Separation Firewalls

PUBLIC RESTROOMS, DESIGN INTENT

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Saferand easierinstallation

FIRE RATED GLAZING System Guide

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

6mm Two Door Offset Quadrant

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Mark Cramer Inspection Services, Inc.

Gypsum Board Systems Manual

Fiberglas, Exterior Wall Thermal Insulation

Seismic Installation for Attic Storage System

Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

NARRATIVE REPORT. The Asbestos Bulk Sample Results Table includes asbestos sampling data.

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)

Inspecting to a higher standard.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Building Regulations for the Conservation of Fuel and Power

Renovating Your Basement

Ceilings without fi ller. VoglFuge / VoglJoint. Acoustic design ceilings

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

17,280 square feet Overview:

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Fire Resistance of Brick Masonry

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Guide to domestic building renovation. Telephone: Fax:

Light Steel Framing (LSF) Product Information

DE Frame with C Series Sidelight

British Gypsum Guide to Timber Frame Construction. March 1998

sound reduction systems for commercial, educational and industrial environments

Services Enclosures and Protected Shafts - Maintaining Compartmentation

March 14, Installation of Bay, Bow and Garden Windows

HORIZONTAL INSTALLATION

MRI RF SHIELDING DESIGN

HDA

H-Stud Area Separation Wall System

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

GYPSUM BOARD AND PLASTER

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Moisture Control. System Solutions to Prevent Mold

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Installation Guide. Bath and Wall Surrounds SERIES B

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Batibox TM flush-mounting boxes for dry partitions

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Transcription:

Wall Lining Systems Quick, simple and cost-effective to use, the Speedline dry wall liner is suitable for internal use in all commercial and domestic applications. It can be used to dry line masonry backgrounds, uneven walls or walls with surface-fixed services, for concealing services, cavity walls and where the cavity width between the wall and the back of the plasterboard lining ranges from 25 to 180mm. Perimeter Track (WL60) Wall Liner (WL507) Fixing (AWL03B, AWL04B or AWL08) Wall Board A completely dry system using secure mechanical fixings Surface-mounted services can easily be accommodated Mineral wool can be incorporated within the cavity for thermal or acoustic insulation Suitable for fixing all types of plasterboard Before installation, walls must be treated for any damp Secure fixing into existing background is essential when installing this system 50

Partitioning Systems 18 Wall/Ceiling Liner 6.0 6.0 18 45 Perimeter Track 28 18 Wall Liner System Product Product Description Stock Lengths Weight per Code Metre Length Kgs WL507 Wall/Ceiling Liner x 0.5mm 2.400 0.83 2.700 0.94 3.000 1.04 3.600 1.24 WL60 Perimeter Track x 0.5mm 3.000 0.74 Accessories (Wall Liner System) Product Product Description Weight per Code Box Kgs AWL03B Fixing 75mm leg 3.70 19 AWL04B Fixing 125mm leg 5.60 AWL08B Fixing 175mm leg 7.50 AWL05B Wall/Ceiling Liner Connector 1.35 51

Wall Lining Systems Wall Liner System By replacing the wet trade alternative, with all the Speedline partition and quality system offers practical, cost-effective lining to meet the needs of fast-track building methods. It also has a low thermal capacity with a crack-resistant surface so paint or ceramic tiles can be applied directly. Compatible with all our partition and suspended ceiling systems, wall liner can be used with a range of gypsum wallboards and thermal laminates to line brick, block and concrete walls that are reasonably dry and protected within the building envelope. Wall (AWL03, AWL04 or AWL08) Plasterboard (WL507) Wall Liner (WL60) Track (AWL03 or AWLOF) Suitable for fixing all types of plasterboard, the wall liner system is easily cut to length, fits easily together and creates a seamless surface that will receive most decorative finishes. It creates a void for services, mineral wool can be incorporated for thermal or acoustic insulation. It is also an excellent system for levelling poor quality blockwork. AWL04 Fixing 125mm legs AWL03 Fixing 75mm legs AWL08 Fixing 175mm legs 52

Partitioning Systems Construction Establish the depth of the cavity and fix wall liner track WL60 at 600mm centres to the floor and ceiling with the shallow leg towards the wall. At max 800mm centre,fix brackets AWL03, AWL04 or AWL08 to the wall. Cut Wall Liner Section WL507 to length and slot it into the top and bottom track. Adjust brackets to suit board tolerances before final tightening, then fix with self-drilling screws to the side of the Wall Liner Section. If a bracket protrudes beyond the face, simply bend the overhang over. Fix plasterboard using correct length drywall screws. Fixtures Heavy or medium to heavy fixtures such as heating units, radiators, cupboards and washbasins must be fixed with proprietary anchors which are long enough to pass through the cavity and penetrate the masonry background to a suitable depth. Installation Easy to cut to length using tin snips Door frames simply formed Frames easily fit together Ceiling (AWL03, AWL04 or AWL08) Insulation if required (WL507) Wall Liner Plasterboard (AWL03, AWL04 or AWL08) (WL60) Track 53

Wall Lining Systems Wall Lining I Stud Tracks Wall Lining Systems Wall Lining I Stud Tracks Independent Wall Lining The Speedline independent wall lining systems combine the features of other metal systems to give high strength and quickly assemble dry linings. They are designed to be installed clear of a variety of existing backgrounds. Dry lining reinforced concrete walls, steel framed walls and renovation work where existing walls may form an unsuitable substrate for other systems. Walls must be treated for any damp before installation. Independent wall using I Stud I Stud Insulation if required Track Speedline systems allow space for services, and also for high levels of thermal and acoustic insulation Speedline systems offer a range of I stud widths of 50mm, 60mm, 70mm, 92mm & 146mm to accommodate a wide range of height requirements and can achieve a maximum height without bracing of 7.2 metres Speedline systems are suitable for fixing all types of plasterboard Free-standing from masonry to allow for services I stud holds insulation well ready made holder Sight line for easy installation of board panels Bracing to the structure not required Service holes for cables or pipes Wall board 54

Partitioning Systems Wall Lining I Stud Tracks I Stud Applications Upgrade to existing masonry walls I Stud I Stud Max Nom Nom Width Height Weight Width mm m kg/m 2 mm 50 2.4* 10 190 MD 100mm brickwork and I Studs 60 3.0* 11 200 One layer of 12.5mm standard MD 70 3.6* 11 210 wallboard 25mm Glass mineral wool 92 4.5* 12 230 146 6.9* 12 286 100mm brickwork and I Studs Two layers of 12.5mm standard wallboard 25mm Glass mineral wool * Denotes Unbraced to background Performance is dependent on substrate behind 50 2.7* 19 203 60 3.9* 20 213 SD 70 4.5* 20 223 92 5.4* 21 243 146 7.2* 21 299 Extra Deep Track Installation Wall Lining Systems Wall Lining I Stud Tracks 38 70 Free standing from masonry to allow for services Available in 50, 60, 70, 92 or 146 wide Available in 72, 94 or 148 wide Flat Bracing Strip 70 Partition Brace 0.5 Deep Track 50 I Studs holds insulations well. Ready made holder 6 70 Available in 52, 62, 72, 94 or 148 wide Joining of I Studs To join lengths of I Studs together use a short length of Deep Track approximately 300mm long. I Stud Sight line for easy installation of board panels Deep Leg Track 55

Wall Lining Systems Wall Lining Systems Wall Furring Wall Furring The Speedline Wall Furring section offers a practical, cost-effective lining solution that meets the needs of fast-track building methods by replacing the wet trade alternative. The sections can be used in combination with a range of gypsum wallboards and thermal laminates to line reasonably dry and protected brick, block and concrete backgrounds. General purpose adhesive Wall Furring Section (WF559) Site line to line boards Lining new masonry walls for domestic or commercial use Lining old masonry walls which have an even background Quick and cost effective to install No mechanical fixing is needed with standard wallboard Suitable for fixing all types of plasterboard Easy to fit Quick installation to cover problem walling Wall Furring Section 48 9.5 38 This system is a low thermal capacity lining, which has a crack-resistant surface suitable for either direct decoration or ceramic tiles and is compatible with our partition and suspended ceiling systems. This system should not be used to isolate dampness or in persistently humid environments Wall Furring System Product Code WF559 Product Description Wall Furring Section x 0.5mm Construction The Speedline Wall Furring Section (WF559) is fixed into place using dabs of general purpose adhesive approximately 200mm long at 450mm centres. Wall Furring (WF559) must be fitted horizontally at the floor and ceiling. The vertical lengths of sections must be fitted at 600mm centres. If ceramic tiles are being installed the centres must be reduced to 400mm. 56 Stock Lengths Metre 2.100 2.800 Fixtures Weight per Length Kgs 0.59 0.78 Heavy or medium to heavy fixtures such as heating units, radiators, cupboards and wash basins must be fixed with proprietary anchors long enough to pass through the cavity and penetrate the masonry background to a satisfactory depth.