Steam Sterilization Autoclaves. Series SteriMega Plus

Similar documents
LyoBeta. R+D Freeze-Dryers

BSL3 and BSL4 Autoclaves. Laboratory Line

FVA/A1 saturated-steam sterilizer

Steripro cgmp. Steam Sterilizers

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

Questionnaire Pure Media Systems

German engineering under high pressure

Medical Waste Autoclaves. Medical Waste Autoclaves

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line

FOF INDUSTRIAL SATURATED STEAM STERILIZERS

Large Steam Sterilizers for the Life Sciences. Laboratory Line

Hospital Sterilizers. T-Max Line

AUTOCLAVE STEAM STERILIZERS

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you

Animal Laboratory and Vivarium Steam Sterilization Autoclaves

LABOKLAV. Autoclaves Made in Germany.

STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA

Horizontal Steam Sterilizers. Healthcare Line. Since

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Sterilizers with extra class

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Material test chamber with mechanical convection

Heating oven with mechanical control

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Specifications. Amaro 5000 & Steri 21 MD009/04 EN. A. J. COSTA (IRMÃOS), LDA. Desde 1953 ao Serviço Médico-Hospitalar

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

GE STEAM STERILIZERS FOR PHARMACEUTICAL PRODUCTION

STEAM STERILIZERS FOR THE LIFE SCIENCES

GETINGE GEW cgmp WASHER/DRYERS SECURING CRITICAL CLEANING IN THE MANUFACTURING ENVIRONMENT

Heating oven with mechanical convection

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Touchclave-Lab... the revolutionary new range of square-section laboratory sterilizers from LTE Scientific

Incubator with mechanical convection

solarplus solar systems general features

Clinic Washer-Disinfectors. Washer-Disinfector Line

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

RPV - RP - RA air handling units

Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior

LTE Scientific Ltd. Touchclave-Lab... the revolutionary range of square-section laboratory sterilizers from LTE Scientific

Laboratory Division. Product Range Cold Storage Clean Air Lyo

Vacuum drying oven for non-flammable solvents

AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave

MFP14, MFP14S and MFP14SS Automatic Pumps

OT 40L / 90L. Laboratory Steam Sterilizers

Freezers - Ultrafreezers. Platilab & Irilab Series

High Capacity Hot Air Dryer

ECOCIAT. Domestic hot water heat recovery unit

How To Control A Medical Device With A Pc System

Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Product-friendly and fast...

Cooking at the Speed of light!

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Desuperheater Online Program Sizing Guidance

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

MUELLER FALLING FILM CHILLERS

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Pharmaceutical Rotary Presses. PharmaPress 800. High Speed Double Rotary Press

Sterilizers for the pharmaceutical industry, research and laboratories

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Trocknungs_Prozess_engl_04_ :14 Uhr Seite 1 YOUR COMPETENT PARTNER. Drying- and Processing Technology

Getinge GEB Series Biosafety Sterilizers. Safe, reliable decontamination in biocontainment facilities

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Steripro cgmp. Steam Sterilizers

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Digital inductive conductivity transmitter

PBX Series Quick Fit Connector Bimetallic Steam Traps

Corrugated Tubular Heat Exchangers

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical

VAD Variable Area Desuperheaters

Thermo Scientific Heratherm Microbiological Incubators. Safe,

How To Use A Flowmeter

Commercial Semi-Instantaneous Water Heaters

Laboratory- and sterilisation equipment HMC EUROPE

The Power of Innovation. For better Sterilization. Autoclaves: Systec V-Series

Autoclave Design Considerations

IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

Monitoring the autoclaving process in the pharmaceutical industry

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

Laminar Flow Cabinets and Workstations

Commercial Gas Furnace Upflow

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Laminar Flow Cabinets

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

LARGE PROJECTS REQUIRE STRONG TEAMS

Drainage and Grease Management for the Commercial Kitchen

Steam Sterilization and the 2007 Revision of PDA Technical Report 1

Penetration tests according to the ISO 11140

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Transcription:

Steam Sterilization Autoclaves Series SteriMega Plus

SteriMega Plus A choice of quality Telstar has been developing sterilization systems for the pharmaceutical and medical devices industries as well as for R&D laboratories and animal facilities for over 30 years. We have focused our experience in the field of sterilisation equipment under cgmp guidelines so we are nowadays one of the market leaders and trendsetters in this segment worldwide. Engineering and manufacturing practices follow ISO 9001 procedures, ASME BPE criteria, GAMP guidelines, etc. Design and construction meets the most stringent Regulations and Codes from Europe, USA and others concerning Safety and Pressure Vessels. To ensure the equipment meets your requirements, we work in partnership with you and a dedicated team follows your order as a unique project. We develop specific Quality Plans (DQ, IQ and OQ) and undertake factory acceptance testing (FAT). Multiple cycle possibilities SteriMega Plus steam autoclaves offer you a high degree of cycle versatility: dry goods and porous loads are available as standard. The control system allows you to adjust vacuum/pressure rates, number of pulses, dwell time, etc. Standard configuration also includes pre-programmed cycles such as Bowie & Dick test, Automatic chamber leak test and Automatic SIP vent filter. Standard and Cycle options Cycle types available T ype of load SM- V SM- H Gravity displacement (fast exhaust) S Standard Standard Gravity displacement (slow exhaust) LV, SV Standard Standard Saturated steam with vacuum drying S, P Standard Standard Saturated steam with assisted cooling by water in jacket LV, SV Option Option Saturated steam with heated pressurised pulses BRS Option Option Saturated steam with assisted cooling by direct water cooling with/without ΔT control LS - Option Saturated steam with assisted cooling by fan and cooling coils LS - Option Steam + Air mixture with smart ΔP control LS - Option Superheated water shower with smart ΔP control LS - Option SteriMega Plus Autoclaves Range S: Solid items P: Porous loads LV: Liquids in vented containers LS: Liquids in sealed containers BRS: Bagged rubber stoppers

Design & construction features Durable Construction The chamber, doors and process pipe work are constructed in stainless steel AISI 316L for better resistance to stress fatigue and corrosion. Door seals by means of a special silicone gasket which does not require permanent lubrication. Option it is coupled with a compressed air back up system. Design for GMP The chamber and door inner surfaces are mechanically polished to Ra 0.76 µm as standard, with the longitudinal edges rounded to facilitate cleaning. Option to Ra 0.51 is also available. Piping joints are orbital or TIG welded. Removable connections are preferred, with in-line sanitary fittings sealed with pharmaceutical grade gaskets. All pipe work connected to the chamber and chamber floor slopes towards the drainage and dead legs are minimised to avoid fluids stagnation. An air differential seal separates the technical area from the cleanroom or contained laboratory.

Process Reliability The chamber internal surfaces are insulated and heated by means of separated black steam flowing through a full dimple jacket. Pure steam inlet is controlled with a PID valve and condensates are continuously evacuated of through the drainage offering you excellent uniformity of temperatures; better than ± 0.5 C during all the sterilisation phase. Fulfilling the requirement of EN-285. Safety and Ergonomic Design for Users The double access hinged panels at the front-side of the equipment are unique feature in that they provide unrestricted access for maintenance without the need to provide additional space at the side of the equipment. This enables installation in a very compact space compared to the more traditional approach. In fact, 95% of the steam autoclaves on the market are designed access to the technical area from the side, which means providing space additional to the footprint of the equipment. The compact technical area is designed to save space but keeping in mind ease of maintenance, allowing access to components and replacement of spares. Potential hot piping is insulated. Option in addition to the hinged front-facing access panels, the chamber access door is also able to be swung on hinges when in the open position, irrespective of whether its motion is side-to-side or vertical. This action further facilitates maintenance access and enables a more thorough cleaning process. The OEM components like valves, filters and measuring instruments and so, are of the highest quality and state of the art technology. They are sourced from first brands widely available in the marketplace. Full material certificates, instrumentation calibration certificates are traceable to national standards and certificates of conformity are provided.

Control systems The unit is controlled by a PLC, which contains the operating programme and parameters for creating and storing recipes or cycles. The control panel features: Colour touch-screen that displays the main functions and performs as human-machine interface (HMI). Control lights: Locked doors, Alarm, Cycle running, End of cycle Push buttons: Open/Close door, Alarm acknowledgement Chart recorder (option) The supervisory and control system has two versions: HMI MicroSter The Microster is the simplest version, accurate and easy to use, ideal for research laboratories, quality control and auxiliary service equipment. This version includes a thermal printer for recording main events and parameters of the cycle: Cycle parameters, readings, alarms, etc. SCADA PharmaSter As option, the unit is supplied with our complete SCADA control system PharmaSter. This system includes an industrial PC with touch-screen colour display. The software allows not only for supervision and control of the process, but also compiling, storing and processing the whole information in a batch oriented mode. The system is fulfilling 21 CFR Part 11 guidelines.

Technical data MODEL Inner c hamber dimensions Chamber Overall dimensions Approx. Door Width Height Depth Volume Width Height Depth weight sliding mm mm mm l mm mm mm kg motion 5512 V 500 500 1.200 300 1.345 2.200 1.620 1.200 Vertical 6612 V 600 600 1.200 432 1.545 2.200 1.620 1.500 Vertical 6617 V 600 600 1.700 612 1.545 2.200 2.120 1.700 Vertical 8812 V 800 800 1.200 768 1.785 2.200 1.620 2.100 Vertical 8817 V 800 800 1.700 1.088 1.785 2.200 2.120 2.350 Vertical 81012 H 800 1.000 1.200 960 2.250 2.200 1.620 2.700 Horizontal 81017 H 800 1.000 1.700 1.360 2.250 2.200 2.120 3.000 Horizontal 101212 H 1.000 1.250 1.200 1.500 2.650 2.500 1.660 3.500 Horizontal 101217 H 1.000 1.250 1.700 2.125 2.650 2.500 2.160 4.200 Horizontal 101512 H 1.000 1.500 1.200 1.800 2.750 2.500 1.660 3.900 Horizontal 101517 H 1.000 1.500 1.700 2.550 2.750 2.500 2.160 5.100 Horizontal 101520 H 1.000 1.500 2.000 3.000 2.750 2.500 2.460 5.300 Horizontal 122112 H 1.200 2.100 1.200 3.024 3.280 3.000 1.700 5.900 Horizontal 122117 H 1.200 2.100 1.700 4.284 3.280 3.000 2.200 7.600 Horizontal 122120 H 1.200 2.100 2.000 5.040 3.280 3.000 2.500 7.800 Horizontal Note: Other chamber sizes are available under request. Please contact telstar@telstar.com for further information. Options and accessories Beside of the optional cycles already stated, these are the different P&ID, layout or mechanical options available under request. Additional temperature probes for control/monitoring/ independent recording Additional pressure transducer for back-up/independent recording EN 285 steam test connectors EN 285 air detector FWIT front panel connections Hinged door instead of sliding motion type Chamber mechanical polished to Ra < 0.51 µm Pit mounted arrangement Left-hand sided chamber Delivery in two pieces Gas-tight barrier (bioseal), one or both sides Integrated electric steam generator Automated cart loading-unloading systems Headquarters Av. Font i Sagué, 55 Parc Científic I Tecnològic Orbital 40 08227 Terrassa (Spain) T +34 937 361 600 u+34 937 861 380 United Kingdom Unit 4, Shaw Cross Business Park Horace Waller VC Parade Dewsbury West Yorkshire WF12 7RF (UK) T +44 (0) 1924 455 339 North America 1504 Grundy s Lane Unit 1 Bristol, PA 19007 (USA) T +1 215 826 0770 u+1 215 826 0222 China No. 30 Jin Wen Road, Zhu Qiao Airport Ind. Zone, Nanhui District 201323 Shanghai T +86 21 58 093 731 u+86 21 58 092 857 i www.telstar-lifesciences.com ISO 9001: Certified Company BR-STERIMEGAPLUS-EN-0515 Telstar reserves the right to improvements and specifications changes without notice.