FOF INDUSTRIAL SATURATED STEAM STERILIZERS
|
|
|
- Lynette Fields
- 9 years ago
- Views:
Transcription
1
2 PROCESS In the early 1950s, the pharmaceutical industry entered a highly dynamic stage of evolution which required machines and production process that had been unthinkable up to then. Fedegari immediately realized that the autoclaves begin used at the time in pharmaceutical work were hospital machines which had been modified only in a few details of their operation and proposed the first saturated-steam sterilizer specifically designed for the pharmaceutical industry, introducing construction and process-control concepts which were absolutely innovative in those years. This spirit has been a constant trait of Fedegari since then; the company chose to grow thanks to continuing innovation, despite being aware of the risk of being later imitated by many competitors. Since those early years, and despite the adoption of more specific sterilization processes, such as superheated water spray or steam-air mixture methods, the steam autoclave is still among the favorite staples of Fedegari production. Even today it is still the simplest, cheapest, and most flexible process for treating most of the products and items ordinarily used in pharmaceutical work. Faithful to its principle of innovation, Fedegari offers this folder to present its saturated-steam autoclaves in their latest development. The high operating flexibility of these autoclaves arises from the intrinsic characteristics of the saturated-steam process, from the features of the autoclave's construction and from the process controller's flexibility. Every sterilizer is equipped with a water-ring vacuum pump which operates during various steps of the process, such as: initial evacuation of the air by vacuum/steam pulses or by steam injection constant draining of the condensate from the chamber, according to the principle of "dynamic steam" treatments below 100 C final drying of the loads. Another special feature - one which used to be opposed but is now adopted by other manufacturers as well - is the control of the sterilization stage according to a pressure signal, rather than temperature. Obviously, the temperature readout varies as a function of the position of the sensor, whilst the pressure is uniform throughout the chamber. However, process control is performed by detecting in the chamber (and from inside the product) temperature signals whose match with the pressure value, as constantly verified by the controller, demonstrates that the autoclave is operating correctly. This principle, in saturated-steam conditions, that is to say, when there is a two-way T/P correspondence, allows to obtain uniformities in sterilization temperature which are far better than the currently required level of ± 0,5 C. Fedegari can certify this uniformity also thanks to the availability of sophisticated instruments.
3 The flexibility of the sterilizers of the series, once the suitable plant options have been selected, makes them suitable for a wide range of treatments, some of which are mentioned below: sterilizations of various solid materials. sterilizations of porous materials. sterilizations of filled ampoules with fast vacuum for tightness test. sterilizations of filled ampoules, vials or bottles with cooling by means of D.I. water spray under counter-pressure of sterile air. sterilizations as above, with cooling by means of: - heat-sterilized and cooled D.l. water spray - circulation of cold water in jacket with optional circulation of the air by magnetically driven fan(s). tyndallizations, pasteurizations, inactivations. ampoule tightness test with penetration of dye solutions. chamber vacuum/pressure tightness tests. programmed developments of vacuum/steam pulsing and heating/cooling phases. When treating LVP, especially if stored in deformable containers, it is often convenient to use superheated water spray or steam-air mixture sterilization processes in order to prevent the effects of differential pressures between the inside and the outside of the containers. Accordingly, we strongly suggest to discuss every potential application with the Supplier. and of new doors, solving the problems that at the time affected these structures (FIG 1). At the same time, Fedegari began to manufacture the autoclave piping using only stainless steel (AISI 316L), introduced the dovetail-shaped section pneumatic gasket and the machining of the door frames by NC miling. And more, our welding methods: by using the latest automatic and robotized system, over 90% of all the welds on an autoclave of this kind are performed automatically. This has led to the standardization of construction models which flawlessly withstand the repeated heat and pressure cycles as well as localized and diffused corrosion. Depending on the dimensions and/or kind of process, the chambers can have a circular or rectangular cross-section; they have a jacket which surrounds them almost entirely and the inside surface of the chambers is mechanically polished until a roughness Ra < 0,1 µm is achieved. The doors can be of the automatic sliding type or of the semiautomatic hinged type. Both versions use the same construction model, with the characteristics outward camber and the same type of patented gasket (fig. 2-3). fig.2 CONSTRUCTION Fedegari has introduced innovations not only in processes but also in construction. Over time, these innovations have become established standards. In 19 Fedegari acquired the firs CAD workstations to study, by means of finite-element programs, the fatigue behavior of rectangular chambers fig.1 fig.3
4 These constructive solutions are highly sophisticated yet conceptually very simple, being the result of years of experience and of a fair dose of original thinking. The difference between the two versions lies in the opening method. In the first version, a motor provides horizontal or (in smaller sterilizers) vertical sliding of the door. In the second version, the motor moves the door through 45, disengaging/engaging it with respect to the recesses of the chamber and leaving it to the operator to manually open/close the door by rotating it on hinges. There is no difference in price between the two versions. SPECIAL CONSTRUCTIONS ROTATING LOAD (FIG. 4) The load constantly rotates by virtue of a special drum which revolves inside the chamber - which contains the trolleys. The drum is rotated through a magnetic coupling and its speed, direction and intermittent motion can be adjusted. Some of the possible applications of the system are: treatment of suspensions and emulsions better performance in vacuum tightness tests for ampoules better transmission of heat into the load. AUTOMATED LOADING/UNLOADING SYSTEMS (FIG. 4) Our solution is simple and reliable like no other. The pallets travel on benches which have freewheeling rollers made of solid stainless steel. A rack-rod, coupled with a motor provided with a pinion outside the autoclave, automatically pushes the load into the chamber or pulls it out. The entire system requires no lubrication. LOADING SURFACE AT FLOOR LEVEL This solution is sometimes required to allow direct loading/unloading of the chamber by using external/internal trolleys and requires an installation pit. fig.4 COMPLETE ELASTOMERIC STOPPER TREATMENT This treatment includes washing, rinsing, siliconizing, sterilization, thorough drying and automatic unloading into the sterile area. The method uses a special drum which is slowly turned inside the autoclave chamber by a magnetic coupling. The special internal shape of the drum ensures: highly effective washing, siliconizing and drying automatic unloading of the product into the sterile area by reversing the direction of rotation and by means of the special self-sterilizing chute on the unloading door. TREATMENT OF HIGH PATHOGEN (HP) RISK MATERIALS These materials require highly specialized processes which must completely avoid any risk of external contamination. The principle applied by Fedegari is the most reliable since: the air that is initially present is kept in the chamber until sterilization ends and is mixed with the steam by fans driven by a patented magnetic coupling (Fig. 2) the condensate which accumulates on the bottom of the chamber is discharged, when sterile, only at the end of the sterilization process. PROCESS CONTROLLER A high-performance process controller (described in a separate folder) is provided. ACCESSORIES AND OPTIONS various kinds of external and internal trolley boxes for ampoules and bottles of various kinds built-in electric steam generator (available for chambers up to 1 m 3 ) water pump for supplying steam generator and/or for spray in chamber mains steam filtration system system for the closed-circuit sterilization/cooling of the load cooling spray water. fig.5
5 1 Magnetic coupling for rotating the stopper treatment drum. 2 Sterilizing and filtration system for chamber air; 8 can be sterilized in place with an automatic program. An automatic filter integrity control system can be added Two ports for validation sensors. 9 4 Vacuum pump with safety against lack of water, equipped with special silicone connections to eliminate the transmission of vibrations Piping entirely made of AISI 316L stainless steel, 1 equipped with sanitary-type quick couplings with automatic orbital welds and sanitary-type valves made by Fedegari AISI 316Ti stainless steel sterilization chamber and AISI 304 (optionally AISI 316) jacket with external reinforcements. Steam supply and temperature control are separate for the two chambers Patented pneumatic door gasket ensures flawless operation without requiring vacuum for retraction. Requires no lubrication. 4 8 Self-supporting cabinet made of AISI 304 stainless steel, formed on a bending press and satin-finished externally. All supporting structures are made of AISI Pt100 four-wire flexible RTDs, class 0.1, IEC 751, which can be calibrated by means of the process controller by comparison with a reference instrument - Standard version: 3 product RTDs+3 fixed plant RTDs, expandable total of Safety thermometer with independent flexible RTD: ensures redundant temperature measurements with functional safeties which are independent of the process controller. 11 Thin-film pressure transducer with separation membrane; can be calibrated by means of the process controller by comparison with a reference instrument.
6 MODEL CHAMBER SECTION CHAMBER NOMINAL DIMENSIONS WIDTH [cm] WEIGTH [cm] DEPTH [cm] CAPACITY [ l ] OPERATIVE PRESSURE [abs. barr] SELECTABLE DOORS SEMIAUT. HINGED VERTICAL SLIDING HORIZONTAL SLIDING 1/A CIRCULAR /A CIRCULAR /9 3/1 3/2 3/3 3/ /A 3S/2 3/B 3/C CIRCULAR /9 4/1 4/2 4/3 4/ /9 5/1 5/2 5/3 5/ /9 6/1 6/2 6/3 6/ /9 7/1 7/2 7/3 7/ /9 8/1 8/2 8/3 8/ The above mentioned data are to be intended as indicative. The manufacturer reserves itself the right to change them without notice. Other models available. Slightly lower working pressure for pressure vessels with ASME testing. Albuzzano (PV) - Italia - tel fax
FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS
The key difference between a small vertical or bench-top sterilizer and industrial sterilizer is performance. Small saturated-steam sterilizers with vertical or horizontal chambers were devised many years
STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:
STEAM STERILIZERS DLOV & DLOM series DE LAMA s Quality Management System is certified: more than fifty years of experience in sterilization UNI EN ISO 9001:2000 - Cert. n 0351 UNI EN ISO 13485 - Cert.
BSL3 and BSL4 Autoclaves. Laboratory Line
BSL3 and BSL4 Autoclaves Laboratory Line BSL3 and BSL4 Autoclaves In today s society the need for safe bio-containment systems is increasingly important. This is especially true in the sterilization process
Laboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
FVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line
Vertical and Benchtop Autoclaves for Life Sciences Laboratory Line Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide
Laboratory & Scientific Line. Horizontal Steam Sterilizers
Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The
Clinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
Hospital Sterilizers. T-Max Line
Hospital Sterilizers T-Max Line Hospital Sterilizers Sterilization is a complex process. Like any complex process, many things can go wrong. A Hospital depends on its CSSD: Central Sterile Services Department.
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES Always with you 2 Getinge GEB Sterilizers LIGhTS ON FOR ThE NEw GENERATION STERILIZERS The new Getinge
Laboratory Line. Vertical and Bench-Top Life Science Autoclaves
Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.
Specifications. Amaro 5000 & Steri 21 MD009/04 EN. A. J. COSTA (IRMÃOS), LDA. Desde 1953 ao Serviço Médico-Hospitalar
Specifications Amaro 5000 & Steri 21 1 1. GENERAL INFORMATION 1.1. Technical Introduction A. J. Costa (Irmãos), Lda. steam sterilizers are designed to cover a large field of applications for hospitals
Steam Sterilization and the 2007 Revision of PDA Technical Report 1
Steam Sterilization and the 2007 Revision of PDA Technical Report 1 14 November 2007 Presented By: Mike Finger (Tunnell Consulting) Don Drew (Abbott Bioresearch Center) Agenda: Introduction Sterilization
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory
Getinge GEB Series Biosafety Sterilizers. Safe, reliable decontamination in biocontainment facilities
Getinge GEB Series Biosafety Sterilizers Safe, reliable decontamination in biocontainment facilities A new sense of reality In light of the biohazards we live with today, and may be faced with in the future,
Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical
Vakulab PL All-rounder for laboratory and research Long life time and short cycle times Space saving and ergonomical Model diversity and tailored to specific application MMM. Protecting human health. Vakulab
Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves
Partnership Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Keep your environment safe from Medical Waste with high performance Tuttnauer Medical Waste
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line
Partnership Large Steam Autoclaves for the Life Sciences Laboratory Line Large Steam Autoclaves for the Life Sciences Sterilization in a laboratory environment has its unique requirements. Tuttnauer laboratory
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
German engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Horizontal Steam Sterilizers. Healthcare Line. Since
Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,
Questionnaire Pure Media Systems
1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold
Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.
Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the
Large Steam Sterilizers for the Life Sciences. Laboratory Line
Large Steam Sterilizers for the Life Sciences Laboratory Line Large Steam Sterilizers for the Life Sciences Sterilization in a laboratory environment has its unique requirements. The types of loads that
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
MUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
ASPHALT PLANT, NOMINAL PRODUCTION OF 160 T/H, IN
ASPHALT PLANT, NOMINAL PRODUCTION OF 160 T/H, IN Equipments are designed to reach the nominal production based in the following standard : - 3% aggregate moisture ; - sea level operation ; - aggregate
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
Fact Sheet on Steam Sterilizers at Stanford University
Fact Sheet on Steam Sterilizers at Stanford University By: Environmental Quality and Water Efficiency Group, Stanford University; December 2013 Jennifer Fitch, Marty Laporte, Julia Nussbaum, Adam Kern,
Mechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
Medical Waste Autoclaves. Medical Waste Autoclaves
Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small,
Automatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
Sterilization methods and equipment Lab 1-2
Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
GE STEAM STERILIZERS FOR PHARMACEUTICAL PRODUCTION
GE STEAM STERILIZERS FOR PHARMACEUTICAL PRODUCTION 2 Getinge GE Getinge Steam GE Sterilizers Steam Sterilizers LIGHTS ON FOR THE NEw GENERATION STERILIZERS The new Getinge GE Steam Sterilizers is a range
Steripro cgmp. Steam Sterilizers
Steripro cgmp Steam Sterilizers Steripro cgmp Steam Sterilizers BMT worldwide QUALITY, RELIABILITY, INNOVATIO N BMT USA is a member of the MMM Group, one of the world s leading suppliers of sterilization
VALVE TECHNOLOGY ONE STEP AHEAD. www.sed-flowcontrol.com
VALVE TECHNOLOGY ONE STEP AHEAD COMPANY SED is an internationally operating company, leading in the development, production and worldwide sales of sophisticated valve technologies. YOUR PARTNER FOR AUTOMATED
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
VALVE TECHNOLOGY ONE STEP AHEAD. www.sed-flowcontrol.com
VALVE TECHNOLOGY ONE STEP AHEAD SED FLOW CONTROL COMPANY SED is an internationally operating company, leading in the development, production and worldwide sales of sophisticated valve technologies. YOUR
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
solarplus solar systems general features
SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN Application 1 The first step in selecting an industrial oven is defining the required heat application that your oven will be used for. Heat processing is extensively
Washing knitwear in spray - dwelling compartments
J. Ströhle, G. Schramek /Benninger AG, CH- 9240 Uzwil / Switzerland Washing knitwear in spray - dwelling compartments 1. Summary This paper describes washing of knitwear in spray - dwelling compartments.
Boiling Water Reactor Systems
Boiling Water (BWR) s This chapter will discuss the purposes of some of the major systems and components associated with a boiling water reactor (BWR) in the generation of electrical power. USNRC Technical
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
ENGLISH FORK GUIDE 2013
FORK GUIDE 2013 ENGLISH 1 With a brand which is synonymous with specialists in forest products handling attachments, BOLZONI AURAMO offers its expertise and market leading attachments for all requirements,
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
VAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA
STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA We Listen to Your Needs For over 35 years R-V Industries, Inc. has partnered our engineering and manufacturing expertise with customer ideas to produce
SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents
English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force
Trocknungs_Prozess_engl_04_05 26.09.2005 16:14 Uhr Seite 1 YOUR COMPETENT PARTNER. Drying- and Processing Technology
Trocknungs_Prozess_engl_04_05 26.09.2005 16:14 Uhr Seite 1 YOUR COMPETENT PARTNER Drying and Processing Technology Trocknungs_Prozess_engl_04_05 26.09.2005 16:15 Uhr Seite 2 2 Trocknungs_Prozess_engl_04_05
Filter Aid Filtration
Filter Aid Filtration Filtration is the separation of solids from liquids by forcing the liquid to flow through a porous medium and depositing the solids on the medium. A filter aid (finely divided material
Section 5: Machine Overview
Section 5: Machine Overview Machine Floor Plan Machine Specifications Sequence of Operation Theory of Operation Sensor Location Floor Plan 2007 Douglas Machine Inc. 5.1 Machine Floor Plan Figure 5.1: Machine
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com
EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need
Desuperheater Online Program Sizing Guidance
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Validation Guide. USTR 805j (5) Steam sterilization of Pall filter assemblies which utilize replaceable filter cartridges
Validation Guide USR 805j (5) Steam sterilization of Pall filter assemblies which utilize replaceable filter cartridges CONENS 1. Important Recommendations 4 1.1 Installation 4 1.2 Integrity esting 4 1.3
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations
Stephen Lowe ASHRAE Hampton Roads Chapter Past President AECOM Design Mechanical Engineering Discipline Manager, Virginia Beach Division Professional Engineer Commonwealth of Virginia, NCEES BSME University
Manual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
Pipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
GetinGe 88-SerieS WaSher DiSinfectorS
CUSTOMER:... REFERENCE:... GetinGe 88-SerieS WaSher DiSinfectorS ProDuct SPecification ProDuct The Getinge 88-Series (GETINGE 88 TURBO) is a fully automatic, microprocessor controlled, Washer Disinfector
All Processes Dr. Paul Ruffieux Consultant
PSI-L Isolator Platform All Processes Dr. Paul Ruffieux Consultant 1 Requirements Is it possible to have one Isolator for Filling under aseptic conditions (Grade A) Use of isolator technology in ISO8 room
OUTCOME 1 TUTORIAL 1 - MECHATRONIC SYSTEMS AND PRODUCTS
Unit 57: Mechatronic System Unit code: F/601/1416 QCF level: 4 Credit value: 15 OUTCOME 1 TUTORIAL 1 - MECHATRONIC SYSTEMS AND PRODUCTS 1. Understand the applications of a range of mechatronic systems
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
Some Criteria for Choosing a Steam Boiler for a Microbrewery
Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Originators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible
Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior
Liquid II Cell Culture Media Manufacturing Plant Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior Overview History of BioConcept and Amimed BioConcept has close
LINEAR MOTION CONTROL
LINEAR MOTION CONTROL Technical Data Sheet Static Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these
TECHNOLOGIES FOR SLEEVE APPLICATIONS. English catalogue
TECHNOLOGIES FOR SLEEVE APPLICATIONS English catalogue COMPANY Clever s.r.l. designs and manufactures sleeve applicator machines, with the style and philosophy of a dynamic company that looks to the future
The Power of Innovation. For better Sterilization. Autoclaves: Systec V-Series
The Power of Innovation. For better Sterilization. Autoclaves: Systec V-Series t h e a u t o c l a v e c o m p a n y Systec V-Series: Vertical autoclaves. These autoclaves don't just seem to be different;
GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE
GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE GETINGE GEW 2100LS Cage and Rack Washer - Preventing contamination in animal care 3 CLEAN CAGES, RACKS AND BOTTLES WITH
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
PTFE Slide Bearings 04/10 149
04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL
WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL Siniša Stojan, Ph.D. student Damir Dražić, Ph.D. student Brodotrogir, HR - 21220 Trogir, Croatia [email protected],
A Guide to Trouble-Free Cooling Towers
A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic
LyoBeta. R+D Freeze-Dryers
LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that
40 Vacuum drying ovens
40 Vacuum drying ovens Vacuum drying ovens 41 VD VDL Absolutely reliable drying. Drying with no residues, no danger of incrustation, no oxidation all under gentle cycle conditions. We have also developed
11th International Conference on Urban Drainage, Edinburgh, Scotland, UK, 2008 MONITORING EQUIPMENT AND RESULTS The flow monitoring and sampling programme was conducted over two one week periods, with
T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC EUROPE PROFILE HMC EUROPE Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges,
Guidance on safe use of Autoclaves
Safety Office Reviewed: Dec 2013 Reviewed: DD Month Year Guidance on safe use of Autoclaves 1. Hazards & Uses There are several different types of hazard associated with the use of autoclaves. The main
Sterilizers for the pharmaceutical industry, research and laboratories
Sterilizers for the pharmaceutical industry, research and laboratories Flexible solutions for unique applications MMM. Protecting human health. MMM sterilizers individual in design, equipment and processes
STEAM STERILIZERS FOR THE LIFE SCIENCES
STAM STRILIZRS FOR TH LIF SINS W LISTN TO YOUR NDS For over 30 years R-V Industries, Inc. has partnered our engineering and manufacturing expertise with customer ideas to produce a quality product. We