TECHNICAL CATALOGUE ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS

Similar documents
stainless steel pre-assembled manifolds

Automatic control equipment for HVAC systems

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

MOTORIZED BALL VALVES

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

3/2-way Solenoid Valve, direct-acting, NC or NO

THERMOSTATIC ACTUATORS WITH LIQUID-FILLED SENSITIVE ELEMENTS AND TEMPERATURE LOCKING

Self-operated Temperature Regulators Temperature Regulator Type 1u

ORLANDO srl. M P R OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

2- and 3-port valves with flanged connections, PN 10

Butterfly Valves PN 6/10/16 for flanged connection

kymanual or Automatic - it s your Choice

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Overview of types. Technical data

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Fully Pumped Systems

Hydraulic Control Solutions

Unit 24: Applications of Pneumatics and Hydraulics

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Guidelines for operation of minimum flow control valves

Cooling system components, removing and installing

SISTO-16TWA/HWA/DLU. Type Series Booklet

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Mixing Valves. ARGUS Application Note: Mixing Valves

Cooling system components, removing and installing

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

Oil - kerosene burners

Data sheet ECC 12 and 22

SOLAR HEATING SYSTEMS.

RUBBER SLEEVE KNIFE GATE VALVE

MFP14, MFP14S and MFP14SS Automatic Pumps

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

Thermostatic valve Type AVTA

HERZ-Thermal Actuators

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Floor Heating Warehouse.co.uk

1 DESCRIPTION OF THE APPLIANCE

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

FLANGED END BALL VALVE

Electric Rotary Actuator - On/Off or programmable control actuator

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Wall boiler spare parts

Automatic Bypass Control AVDO

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

POWERS Controls No. 4 Pneumatic Damper Actuator

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

ARB AIR LOCKER Air Operated Locking Differentials

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Digital inductive conductivity transmitter

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Volkswagen Golf > VW Rabbit GTI 2006->

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

AIR LINE VALVES AND GAUGES

PRESSURE REDUCING CONTROL VALVE

! WARNING. Before using product, read and understand instructions.

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

3/2- and 2/2-way cartridge valve type BVE

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Zenith Solar thermal 4.5m pump station Installation manual

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Cooling system components, removing and installing

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Unit 24: Applications of Pneumatics and Hydraulics

Mikrotherm. Manual radiator valves. To be precise.

STABITHERM INSTALLATION & SERVICE BOOKLET

Frequently Asked Questions

BRASS FITTINGS FOR THREADED PIPES

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

We have been working in an ideal climate for thirty years.

NITROUS TRANSFER PUMP INSTRUCTIONS

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

A descriptive definition of valve actuators

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

HEAT INTERFACE UNITS (Modular)

VOYAGER 570G. 744A Sprayer Control

Cooling system components, servicing

Transcription:

TECHNICAL CATALOGUE ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS

TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution manifolds for plumbing and heating systems. Thanks to fully automated production processes, with 72 tooling machines and 51 assembly lines, we are able to produce 200,000 pieces per day. Our innate pursuit for innovation and observance of technical regulations is supported by the company certification ISO 9001: 2008. The company has always considered its focus on quality as the main tool to obtain significant business results: today ITAP SpA is proud to offer products bearing the approval of numerous international certifying bodies. THE COMPANY

ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS

TEC ZONE BALL VALVES

ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS

TEC The motorised zone valves are used to intercept fluid inside the mechanical systems. These can be for heating/air conditioning systems of a building or for sanitary water (hot and cold) distribution. These valves have the function of closing or deviating the fluid passage inside piping. They are especially useful in the following systems: Heating and air conditioning systems, in order to interrupt the heat carrier fluid entry in the distribution manifold, once the temperature set on the environment thermostat is reached Sanitary water distribution systems, in order to stop the flow of water when it is not necessary Solar heat plants, in case the integration of a boiler is needed to use sanitary hot water The motorised zone valves have an ON/OFF type operation: they cannot be used as mixing valves. The advantages of the zone ball valves are the following: High capacity (they are in fact total passage valves) High working pressure (up to 16 bar) High differential pressure (up to 10 bar) Quick manoeuvre times (25 seconds or 50 seconds) The actuators proposed by ITAP SpA are available in two models: Art. 990 Bidirectional actuator with microswitch and relay: it controls opening and closing of valves only if connected to a control (for example, an environment thermostat) Art. 991 Bidirectional actuator with microswitch and relay: it controls opening and closing of valves, not only if connected to a control (for example, an environment thermostat), but also without electrical power. It is in fact equipped with a manual release lever, through which the ball is activated directly by means of the manoeuvre stem OPERATION AND PRODUCT LINE

980 2-way zone ball valve Available sizes: 3/4, 1 and 1 1/4 981 2-way zone ball valve with double union connection Available sizes: 3/4, 1 and 1 1/4 ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS 982 3-way diverter zone ball valve Available sizes: 3/4 and 1. 984 3-way zone ball valve Available sizes: 3/4 and 1.

986 4-way zone ball valve Available sizes: 3/4 and 1. 988 By-pass kit for zone ball valves Available sizes: 3/4 and 1. 990 Electric actuator for zone ball valves Available with 230V 25 seconds and 230V 50 seconds power supply 991 Electric actuator for zone ball valves with manual unlocking device Available with 230V 25 seconds, 230V 50 seconds and 24V 50 seconds power supply. TEC OPERATION AND PRODUCT LINE

ZONE BALL VALVES Nickel-plated brass body Chrome-plated brass ball, full flow PTFE ball seat EPDM O-ring Maximum working pressure: 16 bar Maximum differential pressure: 10 bar Minimum and maximum working temperatures: -10 C (with antifreeze solution), 100 C Threaded connections ISO 228 (equivalent to DIN EN ISO 228 and BS EN ISO 228) Fluid of use: water (maximum glycol percentage: 50%) ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS ACTUATORS Bidirectional synchronous motor Rotation angle: 90 Power supply: 230V, 24V Absorbed power: 4 VA Inrush current: 21 ma Auxiliary microswitch capacity: 2 A Protection degree: IP 54 Operating temperature: -5 C, 70 C Rotation time: 25 seconds, 50 seconds Starting torque: 5 Nm for 25 second version, 10 Nm for 50 second version

3-way diverter zone ball valve art. 982 TEC 3-way zone ball valve art. 984 Open operation 4-way zone ball valve art. 986 Open operation Bypass operation Bypass operation TECHNICAL SPECIFICATIONS

COMPONENTS 13 1211 9 8 14 10 5 1 2 7 ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS 1 Body 2 Nozzle 3 Nut 4 By-pass body 5 End adapter 6 Washer 7 Union 8 Nut 9 Seat 10 O-ring 11 Ring 12 Stem 13 O-ring 14 Ball 15 O-ring 16 O-ring 6 3 15 4 16 Nickel-plated brass CW617N Brass CW614N Nickel-plated brass CW614N Nickel-plated brass CW617N Nickel-plated brass CW617N Fibre Nickel-plated brass CW617N Nickel-plated brass CW617N PTFE EPDM PTFE Brass EPDM Chrome-plated brass CW617N EPDM EPDM

TECHNICAL BENEFITS The ITAP SpA zone ball valves are characterised by some technical benefits. The following are special constructive details of these valves. TEC Stem Nozzle O-ring The manoeuvre stem is mounted from the inside, according to the blow-out proof stem technique. This is to avoid that, in case of high working pressure, the stem is expelled from its seat, resulting in water leaking out. This practice is commonly applied in assembling the ball valves intended for use with combustible gas, where maximum safety of used components is needed. To improve manoeuvring in time, a PTFE ring is placed between the stem and the valve body to reduce static and dynamic friction to a minimum between the stem and the seat. The use of an O-ring coupled with the PTFE seats avoids the possibility that after a long idle time of the valve, the ball could remain blocked, even when the actuator receives consent for a manoeuvre. The zone ball valves with bypass (Art. 984 and 986) are used when the flow in the piping must be diverted and not totally closed. This possibility is especially requested in centralised plants, in which any negative effect due to hydraulic misbalancing must be avoided. Especially when the ball activated by the actuator is placed in closing position, a small bypass hole opens up, diverting the flow directly along the return path of the plant. In order to keep the value of the loss of load attributed to the zone valves constant, a fixed calibration nozzle is placed inside the bypass duct. When the water is transiting through the nozzle, a loss of load similar to that of the plant controlled by the zone valve is generated. TECHNICAL BENEFITS

990 B A / A 85 B 112,5 C 55 C 991 B ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS 980 A / A 91 B 120 C 55 3/4 1 1 1/4 DN 20 25 32 A 90,5 103 116,5 B 60,5 68,5 78 C 40,5 44,5 49,5 D 39 47,5 58 Kg/cm 2 bar 16 16 16 C B A C D LBS - psi 232 232 232

981 D TEC C 3/4 1 1 1/4 DN 20 25 32 A 129 148,5 163 B 20,25 24,5 27,5 B C 40,5 44,5 49,5 D 70 81,5 87,5 Kg/cm 2 bar 16 16 16 A LBS - psi 232 232 232 982 A B 3/4 1 DN 20 25 A 140 163 B 80 94 C D C 64,5 75,5 D 40,5 44,5 Kg/cm 2 bar 16 16 LBS - psi 232 232 984 A B 3/4 1 DN 20 25 A 140 163 B 80 94 C G 3/4 G 3/4 D 43 39,75 E 40,5 44,5 Kg/cm 2 bar 16 16 LBS - psi 232 232 C D E SIZES

986 A B D E 3/4 1 DN 20 25 C A 140 163 B 80 94 C 40,5 49 D 49-63 55-63 ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS E 40,5 44,5 Kg/cm 2 bar 16 16 LBS - psi 232 232 988 D G 3/4 12 C Ø 18 B A G 3/4 A 3/4 1 DN 20 25 A 140 163 B 80 94 C 41 50 D 188 195 Kg/cm 2 bar 10 10 LBS - psi 145 145

Installation TEC The zone ball valves are particularly useful in the context of radiator and radiant floor heating systems. In order to control the temperature of one zone, the electric actuator must be connected to an environment thermostat: once the set temperature is reached, the valve will close automatically, activated by its own actuator. To avoid any technical problem in case of use in plants with the detected presence of condensate, it is advised not to install the electric actuator upside down. ATTENTION: OPENING THE COVER COMPROMISE THE PRODUCT GUARANTEE. INSTALLATION

PRESSURE DROP CHART The pressure drop chart relative to the following items are reported as follows: 980-981 - 3/4, 1 and 1 1/4 982-3/4 and 1 984-986 Bypass - 3/4 and 1 984-986 - 3/4 and 1 Art. 980-981 - 3/4, 1 and 1 1/4 10000 3/4 1 1 1/4 1000 ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS Pressure drop [mm c.a.] Art. 982-3/4-1 Pressure drop [mm c.a.] 10000 1000 100 100 10 100 1000 10000 100000 Flow rate [l/h] Art. 980-981 Kv [m3/h] 3/4 20,2 1 37,3 1 1/4 51,5 10 100 1000 10000 100000 Flow rate [l/h] Art. 982 3/4 3/4 1 1 Kv [m3/h] 9,44 16,07

Art. 984-986 - By-pass - 3/4, 1 TEC 10000 3/4 1 Pressure drop [mm c.a.] 1000 100 Art. 984-986 - 3/4-1 Pressure drop [mm c.a.] 10000 10 10 100 1000 10000 1000 100 Flow rate [l/h] Art. 984-986 By-pass Kv [m3/h] 3/4 1,2 1 2,15 3/4 1 10 100 1000 10000 100000 Art. 984-986 Kv [m3/h] Flow rate [l/h] 3/4 17,1 1 30,6 INSTALLATION / DIAGRAMS

INTERNAL DIAGRAM - R relay - MC1 opening limit microswitch - MC2 closing limit microswitch - MC3 auxiliary free microswitch with normally closed and normally open contact 1) Brown wire always connected to phase 2) Blue wire always connected to neutral 3) Black wire for command connection 4) Purple wire closed valve phase output 5) Red wire open valve phase output 6) Grey wire common auxiliary microswitch 7) White wire N.C. auxiliary microswitch 8) Pink wire N.A. auxiliary microswitch Valve opening Valve closing ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS ENVIRONMENT THERMOSTAT (TA - ET) CONNECTION AND ELECTRICAL POWER SUPPLY DIAGRAM The thermostat works by means of the zone valve, which opens or closes the distribution circuit of the interested zone based on environment needs. The Figure illustrates the electrical connection of the actuator with the environment thermostat.

HOUR COUNTER (CO - HC) ENVIRONMENT THERMOSTAT (TA - ET) AND ELECTRICAL POWER CONNECTION DIAGRAM The count is carried out by means of an hour counter, totalling the valve opening times. The Figure illustrated the electrical connection of the actuator with the hour counter. TEC BLU PUMP MANAGEMENT DIAGRAM The figure illustrates the connection of different actuators with the environment thermostat, the hour counter and the pump. In this diagram, the pump is fed by the phase available on the red wire. The special flexibility of the internal actuator wiring model allows you to have different plant solutions. WIRING DIAGRAMS

ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS OPERATION DIAGRAMS

TEC OPERATION DIAGRAMS

ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS OPERATION DIAGRAMS

TEC OPERATION DIAGRAMS

ZONE BALL VALVES WITH BIDIRECTIONAL ACTUATORS

NOTES TEC We reserve the right to make improvements and changes to the products described herein and to the relative technical data, at any time and without forewarning.

ITAP S.p.A. Via Ruca 19 25065 Lumezzane Brescia (ITALIA) Tel 030 89270 Fax 030 8921990 www.itap.it-info@itap.it 09/2016