Introdução ao DAS e SCSI



Similar documents
Ambiente de Armazenamento

Armazenamento Inteligente

03 infra TI RAID. MTBF; RAID Protection; Mirroring and Parity; RAID levels; write penalty

Chapter 13 Selected Storage Systems and Interface

SCSI The Protocol for all Storage Architectures

Redundancy in enterprise storage networks using dual-domain SAS configurations

iscsi: Accelerating the Transition to Network Storage

Hewlett Packard - NBU partnership : SAN (Storage Area Network) или какво стои зад облаците

REDES DE ARMAZENAMENTO E ALTA DISPONIBILIDADE

M.Sc. IT Semester III VIRTUALIZATION QUESTION BANK Unit 1 1. What is virtualization? Explain the five stage virtualization process. 2.

SAN Conceptual and Design Basics

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

SAN and NAS Bandwidth Requirements

SCSI vs. Fibre Channel White Paper

Open-E Data Storage Software and Intel Modular Server a certified virtualization solution

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Optimizing Large Arrays with StoneFly Storage Concentrators

HBA Virtualization Technologies for Windows OS Environments

Using Multipathing Technology to Achieve a High Availability Solution

Direct Attached Storage

EVOLUTION OF NETWORKED STORAGE

Storage Area Network Configurations for RA8000/ESA12000 on Windows NT Intel

Backup Exec 9.1 for Windows Servers. SAN Shared Storage Option

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems

N_Port ID Virtualization

Block based, file-based, combination. Component based, solution based

Storage Networking Foundations Certification Workshop

Chapter Introduction. Storage and Other I/O Topics. p. 570( 頁 585) Fig I/O devices can be characterized by. I/O bus connections

Using High Availability Technologies Lesson 12

SAP Solutions on VMware Infrastructure 3: Customer Implementation - Technical Case Study

VERITAS Backup Exec 9.0 for Windows Servers

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

Best Practice and Deployment of the Network for iscsi, NAS and DAS in the Data Center

HP iscsi storage for small and midsize businesses

How To Write A Target Midlevel For A Scsi Commandline (For Linux) To Be A Target (For Microsoft) To A Target For A Microsoft Microsoft Sci) (For Awn) ( For Microsoft (For

IOmark- VDI. Nimbus Data Gemini Test Report: VDI a Test Report Date: 6, September

Future technologies for storage networks. Shravan Pargal Director, Compellent Consulting

The PCIe solution from ExaSAN

Storage Area Network Architectures. Technology White Paper. Heng Liao Technical Advisor

Storage Basics. Storage is a huge topic, but this article will give you a high-level look at how it all fits together.

Traditionally, a typical SAN topology uses fibre channel switch wiring while a typical NAS topology uses TCP/IP protocol over common networking

Improving Application Performance, Scalability, and Availability using Microsoft Windows Server 2008 and NLB with Sanbolic Melio FS and SAN Storage

Introduction to MPIO, MCS, Trunking, and LACP

High Availability Server Clustering Solutions

Overview and Frequently Asked Questions Sun Storage 10GbE FCoE PCIe CNA

Computer Organization & Architecture Lecture #19

Symantec FileStore N8300 Clustered NAS Storage System V100R002. Glossary. Issue 01 Date Symantec Corporation

Date: March Reference No. RTS-CB 018

Designing HP SAN Networking Solutions

OVERVIEW. CEP Cluster Server is Ideal For: First-time users who want to make applications highly available

Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.

A Not So Short iscsi Tutorial. Ming Zhang HPCL, University of Rhode Island 10/03

Achieving High Availability & Rapid Disaster Recovery in a Microsoft Exchange IP SAN April 2006

File System & Device Drive. Overview of Mass Storage Structure. Moving head Disk Mechanism. HDD Pictures 11/13/2014. CS341: Operating System

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server

Chapter 12: Mass-Storage Systems

ANZA Formación en Tecnologías Avanzadas

Xanadu 130. Business Class Storage Solution. 8G FC Host Connectivity and 6G SAS Backplane. 2U 12-Bay 3.5 Form Factor

Why Use 16Gb Fibre Channel with Windows Server 2012 Deployments

Storage Solutions Overview. Benefits of iscsi Implementation. Abstract

Managing a Fibre Channel Storage Area Network

IP SAN Best Practices

an introduction to networked storage

Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage

CompTIA Storage+ Powered by SNIA

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

Introduction to Storage Technologies and Terminology

Serial ATA in Servers and Networked Storage

Violin Memory Arrays With IBM System Storage SAN Volume Control

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

DCICT: Introducing Cisco Data Center Technologies

Unit of Learning # 2 The Physical Layer. Sergio Guíñez Molinos sguinez@utalca.cl

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

Implementing Network Attached Storage. Ken Fallon Bill Bullers Impactdata

Windows Host Utilities Installation and Setup Guide

I/O Virtualization Using Mellanox InfiniBand And Channel I/O Virtualization (CIOV) Technology

Copyright 2002 Concord Communications, Inc. Network Health is a registered trademark of Concord Communications, Inc. Concord, the Concord logo,

Virtualization, Business Continuation Plan & Disaster Recovery for EMS -By Ramanj Pamidi San Diego Gas & Electric

Configuration Maximums VMware Infrastructure 3

Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server

Support for Storage Volumes Greater than 2TB Using Standard Operating System Functionality

Certification: HP ATA Servers & Storage

Transcription:

06 infra TI Introdução ao DAS e SCSI DAS; Elements, Benefits and Challenges; Management options; Evolution of SCSI; SCSI 3 architecture; SCSI addressing and communication model; DAS e SCSI comparation

What is DAS? Uses block level protocol for data access Internal Direct Connect External Direct Connect

DAS Benefits Ideal for local data provisioning Quick deployment for small environments Simple to deploy Low capital expense Low complexity

DAS Connectivity Options ATA (IDE) and SATA Primarily for internal bus SCSI Parallel (primarily for internal bus) Serial (external bus) FC High speed network technology Buss and Tag Primarily for external mainframe Precursor to ESCON and FICON

DAS Management Internal Host provides: Disk partitioning (Volume management) File system layout Direct Attached Storage managed individually through the server and the OS External Array based management Lower TCO (Total Cost of Ownership) for managing data and storage Infrastructure

DAS Challenges Scalability is limited Number of connectivity ports to hosts Difficulty to add more capacity Limited bandwidth Distance limitations Downtime required for maintenance with internal DAS Limited ability to share resources Array front-end port Unused resources cannot be easily re-allocated Resulting in islands of over and under utilized storage pools

Evolution of Parallel SCSI ANSI acknowledged SCSI as an industry standard Developed by Shugart Associates & named as SASI (Shugart Associates System Interface) SCSI versions SCSI 1 Defined cable length, signaling characteristics, commands & transfer modes Used 8-bit narrow bus with maximum data transfer rate of 5 MB/s SCSI 2 Defined Common Command Set (CCS) to address non-standard implementation of the original SCSI Improved performance, reliability, and added additional features SCSI 3 Latest version of SCSI Comprised different but related standards, rather than one large document

SCSI 3 Architecture SCSI command protocol Primary commands common to all devices Transport layer protocol Standard rules for device communication and information sharing Physical layer interconnect Interface details such as electrical signaling methods and data transfer modes SCSI Architectural SCSI-3 Command Model Protocol SCSI Primary Command s SCSI Specific Commands Common Access Method Transport Layer SCSI-3 Protoco l Physical Layer SCSI-3 Parallel Interfac e Fibre Channel Protoco l IEEE Serial Bus Serial Bus Protoco l Fibre Channe l Generi Packetized Protoco c l

SCSI Device Model SCSI communication involves: SCSI initiator device Issues commands to SCSI target devices Example: SCSI host adaptor SCSI target device Executes commands issued by initiators Examples: SCSI peripheral devices SCS Initiator Device I Application Client Device Service Reques t Device Service Response Task Management Reques t Task Management Response SCS Target I Device Logical Unit Device Server Tas Manager k

SCSI Device Model (Cont.) Device requests uses Command Descriptor Block (CDB) 8 bit structure Contain operation code, command specific parameter and control parameter SCSI Ports SCSI device may contain initiator port, target port, target/initiator port Based on the port combination, a SCSI device can be classified as an initiator model, a target model, a target model with multiple ports or a combined model (target/initiator model). Example: Target/initiator device contain target/initiator port and can switch orientations depending on the role it plays while participating in an I/O operation To cater to service requests from multiple devices, a SCSI device may also have multiple ports (e.g. target model with multiple ports)

SCSI Addressing Initiator Target LUNs Initiator ID Target ID LUN Initiator ID - a number from 0 to 15 with the most common value being 7. Target ID - a number from 0 to 15 LUN - a number that specifies a device addressable through a target.

SCSI Addressing Example Port Target (Front-end port) Target t0 Port Port Port Port LUN LUN LUN d0 d1 d2 Storage Volumes Host Initiator (HBA) Controller c0 Storage Array Host Addressing: Storage Volume 1 - c0t0d0 Storage Volume 2 - c0t0d1 Storage Volume 3 - c0t0d2 Initiator ID Target ID LUN c0 t0 d0

Discussão e exercícios Em que cenários devemos empregar soluções de DAS? Quais as vantagens oferecidas pelas conexões de armazenamento SCSI e em que cenários melhor de aplicam? Conexões paralelas são sempre mais rápidas que conexões seriais? Há um algum paralelo dos protocolos SCSI com os protocolos de rede de comunicações de dados (TCP/IP)? Qual o papel de um iniciator device?

Leitura recomendada Capítulo 5 Information Storage and Management Storing, Managing, and Protecting Digital Information in Classic, Virtualized, and Cloud Environments 2nd Edition Edited by Somasundaram Gnanasundaram, Alok Shrivastava