Heat cool system. Take control of your pool heating and cooling with the Calorex 34 and new Pro-Pac ranges

Similar documents
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ECOCIAT. Domestic hot water heat recovery unit

ACCENT AIR COMMERCIAL HEAT PUMPS

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

marine/bespoke split applications

Cooling kw Heating kw

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -


SWIMMING POOL HEAT PUMP Owners Manual

Natural geothermal energy.

Split units TH with hermetic compressors

CRAC Precision climate control units for data centres

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

LG Electronics AE Company, Commercial Air Conditioning

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Technical data. Danfoss DHP-A

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

IV. Rear Mount System

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

HP switch LP switch Discharge thermo Comp. Surface thermo

MAC-120HE-01 Air-Cooled Chiller

Heat Pumps for Swimming Pools

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

We have been working in an ideal climate for thirty years.

Versati Air to Water Heat Pump

Local Dealer:

TWE+TTA TWE+TWA T.R.

Commercial Hot Water. Make a difference...

ROTEX gas hybrid heat pump. A strong team.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Heating, cooling and irrigation system for a house. Control with two controllers TS-55T + 2 depending on the seasons. option 1 Functional scheme

FTQ. Daikin Inverter Ducted Heat Pump

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

HEATING, VENTILATION & AIR CONDITIONING

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Daikin Altherma. hybrid heat pump. The natural combination

Nordic Heat Pump Product Guide

Refrigeration Compressed Air Dryer Buran Ultrapulse

Product Data. Split System Cooling F-EN. March 2015

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Split System Cooling Product Data

Cooking at the Speed of light!

Information Guide Domestic Air Source Heat Pumps

Hot Water. Heat pump water heaters. Residential and Commercial R410a

FULL DC INVERTER SYSTEMS

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

ThermoStar Refrigeration Air Dryers

UDSA - UDSBD unit heater

Daikin Altherma hybrid heat pump. The natural combination

Hybrid heat pumps. saving energy and reducing carbon emissions

Heating when you need it Cooling when you don t. NIBE SPLIT Air/water heat pump

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

york air-conditioning products Residential & VRF News 2015

SustainE(Sustainable Energy)

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Combi Unit Genius. The energy efficient Building Service Centre

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

HEAVY DUTY STORAGE GAS

Split System Cooling Product Data

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Glossary of Heating, Ventilation and Air Conditioning Terms

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Air-cooled Chillers with High Speed Centrifugal Compressors

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

HVAC Systems: Overview

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

Air conditioners Heating & Cooling

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Split System Heat Pump Product Data

Failure code manual. content

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Why Daikin? 2015 Houston, Texas USA

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Chilled Water Precision Air Conditioner For Critical Application

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

SWIMMING POOL HEAT PUMP

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors

Selection Tips For Air-Conditioning Cooling Systems

Aerona Air Source Heat Pumps

Building Energy Systems. - HVAC: Heating, Distribution -

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

Are these noise cancelling devices needed to make your chiller quiet??

Product Overview Benefits

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Energy Efficiency HOSPITALITY.

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Transcription:

Heat cool system Take control of your pool heating and cooling with the Calorex 34 and new Pro-Pac ranges Full range of heat pumps for indoor and outdoor use Zero ozone depleting refrigerant Specifically designed for Gulf conditions

SWIMMING POOL HEAT PUMPS HEAT COOL The challenge To provide the swiing pool design engineer with a solution to temperature control which will reliably and economically heat or cool a swiing pool, regardless of ambient air temperature and location. Calorex are world leaders in heat pump technology and were the first to develop heat cool units for swiing pools Enjoyable swiing Dependable swiing pool temperature control is a key feature to enjoyable swiing. For a swim to be refreshing and invigorating the pool water must be the right temperature for the swier, regardless of the influence of seasonal weather. Winter heating During winter, swiing pools continually evaporate water and radiate heat. The combination of these factors causes heat loss which must be replaced through a heater if comfortable water temperatures are to be maintained. Suer cooling During suer, swiing pools are subjected to massive solar gain. Coupled with high ambient humidities which prevent pools from cooling through evaporation, swiing pool water will become uncomfortably hot unless dynamically cooled. THE HEAT PUMP CYCLE HOT GAS COMPRESSOR COOL GAS Key benefits of a Calorex heat cool system: WATER OUT Designed for the Gulf climate WATER IN HEAT EXCHANGER EVAPORATOR AMBIENT AIR Reduced energy consumption No additional equipment required Simple installation & long service life CONDENSED REFRIGERANT HIGH PRESSURE SIDE EXPANSION VALVE COLD LIQUID REFRIGERANT LOW PRESSURE SIDE Suitable for all year round pool use Minimal maintenance Low operating costs

The solution The Calorex answer to this challenge is the 34 range and the Pro-Pac range - providing a heat cool unit for every size of pool and plant room. Why heat pumps? Heat pumps are widely accepted as the most economic and effective method of heating and cooling your swiing pool. Unlike electric flow heaters and boilers that can only provide pool heating. Calorex heat cool pumps will automatically either heat or cool your pool without the need for additional equipment. As an added bonus, a Calorex heat cool pump will produce up to five times the energy it consumes, dramatically reducing the energy consumption of your swiing pool. Why Calorex? Calorex were the first to develop heat cool units for swiing pools and in doing so set the standard for proven performance and reliability. We have thousands of units in operation throughout the Gulf States, the oldest installed in 1981. 6 5 4 3 2 1 Heating method effiency comparison Free energy Paid for energy Gas boiler Oil boiler Heat pump Electricity As further testament to our coitment for manufacturing quality, Calorex is an ISO 91 accredited company under Lloyds register and all our products are tested in accordance with EU standards. Calorex is also a founder member of the Microgeneration Scheme (MCS), a UK Government controlled initiative that demands independent product witness testing as part of a tough quality control procedure. Our heat cool pumps are specifically designed for swiing pool heating and cooling; they are not converted air conditioning units. This means that all components used in their construction are designed to give maximum efficiency and reliability at swiing pool conditions, even in the toughest climates.components used in their construction are designed to give maximum efficiency and reliability at swiing pool conditions, even in the toughest climates.

34 range Our 34 range heat cool pumps are specifically designed for swiing pool heating and cooling - proven over the years to set the benchmark standard. Designed for ducted installation within a plant room or for outdoor installation Designed for plant room installation Over the years, the 34 range has proven to set the benchmark standard for swiing pool heating and cooling. Given the challenges that swiing pool designers face in locating a plant so that it cannot be seen or heard, the 34 range is designed with plant room installation in mind, alleviating the difficulties associated with external siting. Thanks to its centrifugal fan with variable external pressure capabilities, the 34 range can be ducted without loss of performance and comes with a stainless steel drip tray and heavily insulated cabinet as standard. Key points at a glance Capacities from 8 to 7 Zero ozone depleting refrigerant - unlike R22 and R47C, will operate reliably throughout every possible Gulf climatic condition Designed and manufactured in the UK to CE standards Fully automatic operation compressors Water flow switch (only 4 & 734 models) Weather and corrosion resistant construction including plastisol coated galvanised steel cabinet and epoxy coated coils 9/1 marine grade heat exchangers Manufactured under ISO 91 Accreditation - the correct refrigerant in harsh conditions is a non ozone depleting refrigerant which is specifically designed for high temperature applications. The refrigerant within a heat pump circuit is the life blood of its operation and will determine operational efficiency and reliability. The operating envelope of is far greater than that of other coonly used refrigerants. This ensures that the heat pump will have a larger safety margin and always operate well within its capabilities, even in temperatures of 55 C and beyond. Calorex heat pumps are charged with non-toxic, biodegradable, CFC-free refrigerant, which has no detrimental impact on the earth s protective ozone layer.

Pro-Pac range Our Pro-Pac range, which is designed for non ducted installations, shares the same core technology as our well proven 34 range. Heat cool units designed for non-ducted plant rooms or outdoor installation Reliability and efficiency Designed for external installation, Pro- Pac units offer an economic solution to swiing pool heating and cooling, with the same reliability and efficiency as 34 range units. Key points at a glance Capacities from to 14 Zero ozone depleting refrigerant ensures reliable, efficient operation regardless of air temperature Titanium or CuNi heat exchanger Designed and manufactured in the UK Fully automatic operation compressors Water flow switch on all models Comprehensive circuit protection Quiet, efficient owlet axial fans Weather-proof construction Digital thermostat Typical operating envelope, demonstrating the benefit of high temperature refrigerant. Condensing temperature (CT) 7 6 5 4 3 (ET15, CT75) R47c (ET15, CT65) & R22 (ET15, CT65) o C -2-15 -1-5 5 1 15 Evaporating temperature (ET)

Technical data 34 range Specifications Units AW634AHC AW1234BHC AW1834BHC AW4BHC AW734BHC AW4EHC AW734EHC Performance @ Air on 2 C/85%RH Heat output to water (@28 C) Electrical input @ Air on 45 C/5%RH Cooling to water (@ 32 C) Electrical input Heating Cooling 8 1.7 6.5 2. 3.5 1.2 4.1 19 5. 5.5 44 8.2 27 9.2 7 12.8 45 15.7 44 8.2 27 9.2 7 12.8 45 15.7 Electrical data Electrical supply Recoended maximum supply & fuse capacity Maximum starting current standard (LRA) v/ph/hz 24/1/5 32 4/3/5 16 4/3/5 16 4/3/5 35 126 4/3/5 6 126 22/3/6 5 25 22/3/6 9 282 Air data Nominal air flow Fan external resistance (standard) High pressure fan m 3 /h Pa Pa 15 5 3 43 1 117 Variable to meet customer requirements 1 117 Water data Water flow ±1% Pressure drop (water) Water connections Condensate water connections l/min m hd " BSPM " BSPM 2.1 2.2 2.2 66 2.5 5.3 66 2.5 5.3 General data Gas type Compressor type Fan type Sound pressure level @ 3m db(a) Recip 63 65 61 1x Centrifrugal 72 68 72 68 Dimensions Width Depth Height Weight kg 82 72 762 111 16 75 87 157 98 75 1435 283 17 19 1212 411 195 4 1212 69 17 19 1212 411 195 4 1212 69 Options Chiller only Heater only Rear or top outlet on 4 or 734 Soft start High pressure fan 3ph, 6Hz versions Calorex reserves the right to modify these specifications at any time. For accurate sizing please contact Calorex.

Technical data Pro-Pac range Specifications Units Pro-Pac 16 Pro-Pac 22 Pro-Pac 3 Pro-Pac 45 Pro-Pac 7 Pro-Pac 9 Pro-Pac 14 Performance @ Air on 2 C/85%RH Heat output to water (@28 C) Electrical input @ Air on 45 C/5%RH Cooling to water (@ 32 C) Electrical input Heating Cooling 3.5 1.2 4.1 19 5 5.5 3 6 21 6.4 45 8.2 32 9.2 7 12.8 49 15.7 9 16.4 64 18.4 14 25.6 98 31.4 Electrical data Electrical supply (5 Hz) Minimum supply capacity Recoended supply fuse Maximum starting current standard (LRA) Maximum starting current soft start (LRA) NOTE: refer to Calorex for 6Hz supply 3PH 4V 1 16 25 4V 2 25 4V 21 3 96 4V 25 4 12 34 4V 42 6 96 4V 5 7 12 34 4V 84 125 96 Air data Nominal air flow Fan external resistance (standard) m 3 /h Pa 4 5 55 11 14 22 28 Water data Water flow ±1% (CuNi/Titanium heat exchanger) Pressure drop (water) Water connections Condensate water connections l/min m hd inch " BSPM n/a /123 n/a /.2 F/PVC ½ ABS n/a /123 n/a /.2 F/PVC ½ ABS n/a /25 n/a /.7 n/a/2 union 66/3 4.5/.4 BSPM/2 union 1/5 3.4/1.5 /3 BSPM 166/6 4.5/1.7 /3 BSPM 266/1 5.3/2.1 2/4 BSPM General data Compressor type Fan type Sound pressure level @ 3m db(a) 1 x scroll 1 x scroll 52 1 x scroll 62 1 x scroll 64 2 x scroll 68 2 x scroll 2 x axial 7 4 x scroll 2 x axial 71 Dimensions Width Depth Height Weight kg 1264 6 725 1 1264 6 725 145 1525 79 18 219 1665 16 1 329 181 119 1 549 265 119 1 599 221 165 4 165 Options Chiller only Heater only 3ph, 6Hz versions Soft start High pressure fan Condensate insulation kit for plant room installations Calorex reserves the right to modify these specifications at any time. For accurate sizing please contact Calorex.

Our products are designed and manufactured in the UK Technical support and service Comprehensive technical support is provided by our experienced and well qualified team Calorex Heat Pumps Ltd The Causeway Maldon Essex CM9 4XD United Kingdom t. +44 ()1621 856611 e. sales@calorex.com w. calorex.com Heat Cool v14