SYSTEM 7. Vitreous Enamelled Steel Stove Pipes. September 2014

Similar documents
plumbing products guide

Flue Installation. High Efficiency Condensing Boilers

FREESTANDING CLEAN AIR WOODBURNER

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

B. DEFINITIONS LINING OLD CHIMNEYS A. INTRODUCTION C. REASONS FOR LINING

Colonnade Security Pipe

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Installation Instructions

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

GREENSTAR 60/100 HORIZONTAL FLUE

Commissioning of Heat Producing Appliances Burning Solid Fuel

ASX7-4-IOM-7 J

James M. Pleasants Company

Chimneys in Thatched Properties

Installation Instructions

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

Installation Instructions

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

This instruction is valid for all ACD pump models shown on page 2

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Puddle Flange. FRANK Puddle Flange

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Fire Barrier Duct Wrap 15A

Saferand easierinstallation

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Gas-Fired, Residential Storage Type Water Heaters

Installation Instructions

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

SIMPLAIR PIPING TOOL

Float and Thermostatic Traps Series H, C and X

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

General Guidance on the selection and installation of flues and chimneys for wood burning and multi fuel appliances in residential properties.

3 IN 1 BATHROOM HEATER

Planning Information. Passenger and Freight Elevators.

Confort 26. Sliding Systems. Sapa Building System

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Important Information

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Rooflight INSTALLATION INSTRUCTIONS

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

Regulatory Services. Asbestos in the Home. What is asbestos?

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Installation Instructions For Slider Casement Air Conditioners

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Assembly and Usage Instructions

INFRARED QUARTZ WALL HEATER

How to build a Pizza Oven in 4 days

39HQ Airovision Air Handling Units

Digital Fingerprint safe

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Composite Panel Firewall Systems

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

K17.12 Door closers K17. Doors

1 DESCRIPTION OF THE APPLIANCE

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

SRP Pricelist 2015 Including VAT. Stoves for every home

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

4 Installation Requirements

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Chapter 2 Basis of design and materials

Installation Instructions S

PUMP JACK SYSTEM AND ACCESSORIES

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Rockwool Flexi Insulation Application Guide

INSTRUCTION MANUAL AND PARTS LIST MODEL 14-10

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Original Assembly Guide

A GUIDE TO SAFER GAS FLUEING

San josé OWNER S MANUAL

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Isola Steel Gutters Strength and design for extreme climate!

INSTALLATION & USER INSTRUCTIONS

Partitioning & Ceiling Product Information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

HAIR CLIPPER. Model No. HC5150 HC

Saf-T Vent EZ Seal 3" and 4" (75mm and 100mm) Diameter Special Gas Vent (Type BH Class I/II) & Gas Vent Connector

F-Series Camera Mounting Accessories

Packaged Terminal Air Conditioner Wall Sleeve Installation

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Quick response concealed horizontal sidewall sprinkler

All You Need to Know About Asbestos

Decree of the Ministry of the Environment on fire safety of ventilation systems

Transcription:

SYSTEM 7 September 2014 Vitreous Enamelled Steel Stove Pipes Tel: +353 46 95 58030 Fax: +353 46 95 58034 Email: sales@miflues.ie Web: www. miflues.ie

INTRODUCTION Mi-Flues System 7 vitreous enamelled stove pipe has been specifically engineered to give an authentic visual look, whilst at the same time being manufactured using the latest technology to ensure years of trouble free use. PRODUCT DESCRIPTION Produced in zero carbon steel, it has two coats, both internally and externally, of superior class A quality enamel applied. The system is available in five standard diameters 100mm, 125mm, 150mm, 175mm and 200mm. Mi-Flues System 7 is available in three standard colours, Matt Black, Gloss Black and Brown. System 7 is not suitable for condensing applications. APPROVALS Mi-Flues System 7 conforms to: BS 1344 Part 1 Thermal shock resistance BS 1344 Part 7 Heat resistance BS EN 14483 Part 1 Acid resistance BS 6999 Specification for VE low carbon steel flue pipes EN 1443:2003 Chimney General Requirements EN1856-2 T600 N1 D Vm L80180 G(**) Note: ** 4 x diameter of the flue COMPONENTS All enamelled components are made from 1.2mm thick zero carbon steel. All joints are fully welded which provides an excellent gas sealed joint and offers minimum resistance to flue gas flow. The system then has two coats of Class A quality enamel applied to both the inside and the outside of the pipes and accessories. Components have been designed to be installed quickly, safely and simply. The system comprises of plain pipes, pipes with high temperature ceramic sealed doors, bends, tees complete with cleaning inspection caps, appliance adaptors and wall rosettes. APPLICATION Mi-Flues System 7 stove pipe should only be used to connect from the appliance into an existing lined chimney, or to our System 2 twin wall insulated stainless steel chimney, using an appropriate adaptor (as per illustrations on page 8). System 7 flue should not be used externally or should not be used to line an existing chimney. Mi-Flues do not recommend cutting vitreous enamel pipes. This is because it is the vitreous enamel coating that protects the mild steel pipe underneath from corrosion and attack from combustible deposits. Once the pipe is cut the mild steel will be exposed. Adjustable lengths are available to assist in achieving an exact required length. Mi-Flues System 7 should not be used on Insert Stoves. If a connecting flue pipe is required for an Insert Stove Mi-Flues System 1 or Mi-Flues Insert Stove kits should be used. 2 INSTALLATION Mi-Flues System 7 should be fitted at least four times the diameter of the pipe away from any combustible materials. All sockets (female end) should be upward, with the male end dropping into the socket (see illustration below). This ensures that no condensate can escape and spoil the appearance of the finished installation. The diameter specified by the appliance manufacturer dictates the chimney diameter and this should never be reduced. Mi-Flues recommend a maximum run of 1.8m of System 7. In all cases the product must be installed in accordance with Local Building Regulations Document J and the manufacturers installation instructions. JOINT ASSEMBLY The male end of the pipe should sit inside the spigot outlet of the stove and should be sealed with Mi-Flues high temperature sealant (rated to 1000 C) or fire cement in accordance with appliance manufacturers guidelines. There is a hole in the spigot end of the pipe. This hole is used in the manufacturing process and is in no way used for installation purposes. If the fit is quite loose it is possible to pack the joint with fire rope prior to using the high temperature sealant (rated to 1000 C) or suitable fire cement. Locking Clips are available to suit 100mm, 125mm and 150mm System 7 pipes. They are recommended on runs of more than three components. Socket (Female) Flue Gas Direction Male To install the locking clip fit the male end of the pipe into the socket end of the pipe as shown below. Seal the joint using Mi-Flues high temperature sealant (rated to 1000 C) or fire cement. Once sealed, fit the locking clip around the pipe ensuring connection is made with both pipes. Once in correct position secure the locking clip by tightening the tensioning screw with a suitable allen key or flat head screw driver.

LENGTHS ADJUSTABLE LENGTHS Available in 300mm, 500mm, 1000mm and 1200mm. Telescopic Joint Locking Screws Code 300 500 1000 1200 Sys. 7 100 260 460 960 1160 Sys. 7 125 260 460 960 1160 Sys. 7 150 260 460 960 1160 Sys. 7 175 260 460 960 - To fit an adjustable length, loosen the locking screws with a suitable screw driver. Adjust the telescopic pipes to the required length, ensuring that the overlap between the two pipes must not be less the 80mm. Once adjusted to required length, secure the telescopic lengths by fastening the locking screws. Seal the telescopic joint using Mi-Flues high temperature sealant (rated to 1000 ) or fire cement. LENGTH - WITH CLEAN OUT DOOR Sys. 7 200 260 460 960 - ADJUSTABLE LENGTHS Mi-Flues do not recommend cutting vitreous enamel pipes. Adjustable lengths are available to assist in achieving the exact length required. They are available in 125mm and 150mm diameters. Adjustable lengths are available in a matt black, gloss black or brown finish. The short component is adjustable from 310-480mm. The long component is adjustable from 510-880mm. Provision for inspecting a chimney system must be made. s with doors are provided for this purpose. Manufactured with a non corrosive stainless steel access door with high temperature gasket and corrosion proof re-usable locking nuts. s are available in 300mm, 500mm, 1000mm and 1200mm. Code 300 500 1000 1200 Sys. 7 100 B =260 C =97 C =447 B =1160 C =547 Long Adjustable Short Adjustable Sys. 7 125 B=260 C =97 C =447 B =1160 C =547 Dia 125 150 Dia 125 150 Sys. 7 150 B =260 C =97 C=447 B =1160 C=547 B Max. 880 880 B Min. 510 510 C Max. 480 480 C Min. 310 310 Sys.7 175 - Sys. 7 200 - C =447 C =447 - - 3

45 Bend 90 Bend With Door Used to provide a 45 change of direction or can be used in pairs as an offset. Two by 45 bends can be used to create a 90 bend. Used to provide a 90 change of direction and includes a non corrosive stainless steel access door to facilitate cleaning of the chimney system. It may be taken to be equal to two 45 bends. Code (C) (D) (E) Sys. 7 100 145 105 65 45 Sys. 7 125 155 110 70 50 Sys. 7 150 150 110 65 40 Sys. 7 175 170 116 76 54 Sys. 7 200 183 122 87 61 45 Bend - with clean out door (C) Sys. 7 100 114 154 Sys. 7 125 128 168 Sys. 7 150 132 173 Sys. 7 175 148 188 Sys. 7 200 164 199 90 TEE - with Cleaning Inspection Cap This component provides access for cleaning and inspection. It is used to provide a 45 change of direction. Manufactured with a non corrosive stainless steel access door with high temperature gasket and corrosion proof re-usable locking nuts. Code A 90 Tee is used at the bottom of a flue run and allows the flue system to be easily cleaned. It is only to be used when installing the flue at the rear outlet of a stove. This is also designed to take a draught stabiliser. (C) (D) (C) (D) (E) (F) Sys. 7 100 215 165 65 45 73 Sys. 7 125 215 167 70 50 73 Sys. 7 150 210 160 65 45 73 Sys. 7 175 202 149 76 54 63 Sys. 7 200 215 154 86 61 73 90 Bend Used to provide a 90 change of direction. It may be taken to be equal to two 45 bends. Sys. 7 100 204 80 40 35 Sys. 7 125 251 108 40 35 Sys. 7 150 267 113 40 35 Sys. 7 175 260 110 40 35 Sys. 7 200 320 140 40 35 45 Insulated Sleeve Where System 7 passes through a non combustible wall, Mi-Flues recommend that an insulated sleeve is used around the pipe. An insulated sleeve is used to pass the pipe through the wall thus providing a continuous uninterrupted run through it. (C) Sys. 7 100 114 154 Sys. 7 125 128 168 Sys. 7 150 132 173 Sys. 7 175 148 188 Sys. 7 200 164 199 4 (C) Sys 7 100 150 140 Sys. 7 125 180 140 Sys. 7 150 200 140 Sys 7 175 225 140 Sys 8 200 250 140

COMPONENTS Start Off Adaptor This is used to connect an appliance to a System 7 pipe. It is available in 125mm and 150mm. Sys. 7 115 35 Sys. 7 140 35 Coloured finish access door Mi-Flues can supply a coloured finished door (on request) as an alternative to the standard steel finish. Coloured finish door plus Rosette plate Increasing Adaptor Designed to enable three diameters of System 7 pipe to be stepped up one diameter as appropriate. It increases the diameter from 100mm to 125mm, 125mm to 150mm and 150mm to 175mm. (C) Sys. 7 100 125 155 Sys. 7 125 150 155 Sys. 7 150 175 155 Rosette Plates A rosette plate is used for aesthetic purposes to improve the finish of a flue as it penetrates a wall. Available in diameters from 100 mm to 200mm. Rosette plates are available in 90 and 45 angles. They are also available in split form for retro fitting. Each rosette plate comes individually packaged. The pack contains one plate, two half plates in the case of the split rosette, plugs and screws. To install, fit the plate/plates around the flue pipe and secure to a non combustible wall using the fixings provided. To install Mi-Flues System 7 door (as shown below), firstly remove original door by opening the screws with a suitable sized Allen key. Ensure surface of pipe is clean and smooth before fitting new door. To fit the new door, mate the gasket paper up with the inner face of the door and pierce two holes to allow for the fitting of the new screws. While firmly pushing the door against the pipe in order to maintain a good seal, tighten the two screws, fastening the door to the pipe. Mi-Flues System 7 door comes complete with the following components: 1x Vitreous enamelled door and 1x Gasket Paper 45 Rosette Plate (C) 90 Rosette Plate Sys. 7 100 207 250 Sys. 7 125 230 284 Sys. 7 150 254 318 Sys. 7 175 281 356 Sys. 7 200 305 392 (C) Sys. 7 100 207 207 Sys. 7 125 230 230 Sys. 7 150 254 254 Sys. 7 175 281 281 Sys. 7 200 307 307 Adjustable Wall Bracket A wall bracket provides lateral support to a chimney run. It is not a load bearing support. Available in various diameters Wall bracket length can be adjusted from 50mm to 250mm by cutting extended bar. Brackets are supplied with a stainless steel band and galvanised stem as shown. Brackets are not available in a vitreous enamel finish. They can however be sprayed using a suitable enamel paint which is available from your local merchant. 5

Safety / Installation / Regulations Connection to the Chimney System 7 must only be used to make the connection between the appliance outlet spigot and the chimney. It should not pass through any roof space, partition wall or floor, except to pass directly into a chimney through a wall of the chimney (see installation illustration on final page). System 7 should be guarded if there could be a risk of damage or if the burn hazard it presents is not immediately apparent. Connection to System 2 twin wall chimney When a System 7 flue pipe is joined to our System 2 twin wall insulated chimney which penetrates a combustible ceiling, the upper end of the System 7 pipe should terminate four times the diameter of the pipe below a combustible ceiling level Connecting flue pipe components should extend a distance of 600mm off a solid fuel appliance. This connection can be sealed using Mi-Flues high temperature sealant (rated to 1000 C) or a fire cement and the connection must be made in the same room as the appliance itself. Connection to Flexible liner through a non combustible wall Connection to Mi-Flues System 35 flexible flue liner can be made either from directly under the chimney where the appliance is positioned within a fireplace or through the side of the chimney using one of our System 35 adaptors suitable for the purpose (see installation illustration on final page). System 35 flexible flue System 35 Adaptor System 7 length Connection to the appliance System 7 is designed to fit straight into the appliance outlet spigot without the need for an adaptor. However, for smaller fitting diameter spigots, where the joint between the appliance outlet spigot and the flue pipe is quite loose, an adaptor is available to improve the tightness of the joint. When making the connection between the appliance outlet and the System 7 pipe Mi-Flues high temperature sealant (rated to 1000 C) or fire cement should be applied. Safety / Installation / Regulations Bends in Connecting Flue pipes Top Outlet Appliance System 7 should have no more than two bends in its length with an angle no greater than 45 when measured from the vertical. Where possible System 7 flue pipe should rise vertically straight. Rear Outlet Appliance Connection to a rear outlet appliance may be made using the 90 Tee or bend. The maximum horizontal distance from the outlet of the spigot should be no more than 150mm on solid fuel appliances, subject to the appliance manufacturers installation instructions. Distance to Combustible materials Mi-Flues System 7 should be fitted at least four times the diameter of the pipe away from any combustible materials. Chimney Plate The chimney plate provides information regarding the Manufacturer, designation, nominal size, distance to combustibles, Installer name, installation date, chimney location and thermal distance. It is to be completed by the Installer and securely fixed in an unobtrusive but obvious position within the building such as next to the electricity or gas consumer unit, next to the chimney hearth or next to the water supply stop-cock. Cleaning / Maintenance Adequate provision should be made for inspecting and cleaning the chimney system. s and bends are available with access doors in the product range. A 90 Tee is also available as an Inspection/Cleaning component. Cleaning/Inspection access should be provided to suit the installation, unless sweeping can be undertaken through the appliance. The chimney should be inspected regularly and cleaned at least twice a year, depending on usage and type of fuel used. This should be carried out with the use of a brush which should not be made from black steel. The chimney should be maintained to ensure that the construction remains in good condition. Any components showing signs of deterioration which may affect performance should be replaced under professional advice, any evidence of leakage identified by smoke staining should be rectified immediately. If removing the access door during the cleaning process the existing gasket paper should be removed and replaced. Replacement gasket paper is available through your local merchant. Height of Connecting flue pipe A run of System 7 Vitreous Enamel pipe should be limited to no more than a maximum of 1.8 metres. 6

OFFSET CHART The offset chart below is using the recommended Mi-Flues System 7 45 bends. Within a run of system 7 flue no more than two bends should be used. Two bends are used to create one offset. PRODUCT DESIGNATION Mi-Flues System 7 carries the following product designation code. EN1856-2 T600 N1 D Vm L80180 G (**) Note: **4 x diameter of the flue System 7 EN1856-2 T600 N1 D Vm L80180 G(**) Standard Temperature Level Pressure Level N, P or H Condensate Resistance W:Wet or D:Dry Corrosion Resistance (durability against corrosion) Material specification Sootfire resistance and distance to combustibles G:Yes or O:No / distance to combustibles in mm (L) Offset System 7 Offset Chart Diameter 100m 125m 150m 175m m m m m 200m m 0 X 118 123 125 137 144 Y 284 308 302 337 352 300 X 302 311 309 325 331 Y 468 492 486 524 540 500 X 443 453 450 466 472 Y 610 634 628 666 681 1000 X 797 801 804 820 826 Y 963 987 981 1020 1034 1200 X 938 948 945 961 967 Y 1105 1129 1123 1161 1176 300mm Adjustable X Min 309 319 316 332 338 X Max 429 439 437 452 458 Y Min 475 500 494 532 546 Y Max 596 620 614 652 667 500mm Adjustable X Min 450 460 458 473 480 X Max 712 722 719 735 741 Y Min 617 641 635 673 688 Y Max 878 903 897 935 950 System 7 Technical Data Fuel Material Min. Distance to combustibles Solid Fuel, Oil, Gas 1.8mm Double sided vitreous enamelled steel Four times diameter of flue Handling and Storage All System 7 components are individually boxed or packaged and labelled. Relevant information from the label should be transferred to the chimney plate. should be stored in a dry suitable storage location. The product is easy to handle, but care should be taken when holding, fitting or assembling any part of the system. Users are advised to use suitable precautions such as gloves, eye/face protection, protective clothing etc to avoid injury. Installers should be aware of the Safety, Health and Welfare at Work Act 2005 & Safety, Health and Welfare at Work (general application) regulations 2007. Installers should be aware of the possibility of disturbing asbestos when working in older properties. This should be dealt with in accordance with the strict guidance documents. Particular attention should be taken to ensure suitable PPE is used when applying certain fireclays which can be of a caustic nature, as well as when using any other substances which may be harmful. Life Expectancy Under normal operating conditions, and providing the system is installed and maintained correctly, Mi-Flues System 7 should provide many years service and is provided with a 10 year conditional life expectancy. Prolonged periods of slow burning can however reduce the life expectancy of the product. 7

System 7 connection to System 2 twin wall insulated stainless steel chimney System 7 connection to an existing brick chimney System 2 Cowl System 35 Pot Hanger Cowl System 2 Flashing with Storm Collar Back Fill flexible flue System 2 Firestop System 35 Flexible Flue System 2 Chimney Plate Chimney Plate System 2 Black System 2 Firestop System 2 Twin Wall Tapered Adaptor System 35 Adaptor System 7 Rosette Plate System 7 Mesh Insulated Sleeve System 7 Bend with cleaning door System 7 System 7 with cleaning door All flue systems must be installed according to current Building Regulations. Mi-Flues has adopted a policy of continuous product review, and in the interests of development and improvement the Company reserves the right to vary the appearance and performance of any of its products without prior notice. Correct at time of print (September 2014). For updates please check our website. 8 Mi-Flues Ltd, Summerhill Enterprise Ctr., Summerhill, County Meath, IRELAND Telephone: +353 46 95 58030 Fax: +353 46 95 58034 Email: sales@miflues.ie Website www.miflues.ie