3. Inspections performed at Doel 3 in June-July 2012



Similar documents
3. Inspections performed at Doel 3 in June-July 2012

Doel 3 & Tihange 2 RPV Flaw Indications. Evaluation by Belgian Safety Authorities. 1. Regulatory Body in Belgium 28/06/2013

Flawed Reactor Pressure Vessels in the Belgian NPPS Doel 3 and Tihange 2. Comments on the FANC Final Evaluation Report 2015

Qualification of In-service Inspections of NPP Primary Circuit Components

Flawed Reactor Pressure Vessels in Belgian Nuclear Plants Doel-3 and Tihange-2

Structural Integrity and NDE Reliability II

NUCLEAR POWER PLANT PRESSURE EQUIPMENT

Looking into other Industries Qualification of NDT for Swiss Nuclear Utilities

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

ADVANCED NDT TECHNIQUES FOR PLASTIC PIPELINE INSPECTION

Pressure Vessel acc. to PED for Chemical Industry fabricated in China

Oil and Gas Pipeline Design, Maintenance and Repair

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Application of Welding Standards in Hong Kong. S. K. Babu Laboratory Manager - Foundation Techniques Ltd

TABLE OF CONTENT

Phased Array Ultrasonic Detection & Sizing of In-Service Cracks in Heavy Walled Reactor Nozzles - Part 1

NON-DESTRUCTIVE TESTING LEARNING FROM THE PAST, MAXIMISING FUTURE BENEFITS.

WWER Type Fuel Manufacture in China

NEED FOR QUALITY CHECKS ON RAW MATERIALS BEYOND TEST CERTIFICATE - S.RAMANUJAM - K.S.WAGH

BWR Description Jacopo Buongiorno Associate Professor of Nuclear Science and Engineering

Weld Cracking. An Excerpt from The Fabricators' and Erectors' Guide to Welded Steel Construction. The James F. Lincoln Arc Welding Foundation

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

Table of contents. Document History Log. Review Review date Modification description By First edition FANC Bel V 2/40

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Supporting New Build and Nuclear Manufacturing in South Africa

C. PROCEDURE APPLICATION (FITNET)

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

Reliable Flaw Detection. Fast Inspection Times. High quality non-destructive testing services tailored for all your needs.

A World Class Manufacturer of Induction Bends

High Strain Dynamic Load Testing of Drilled Shafts

Solutions for nuclear technology

Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.

JIS G3461 Carbon Steel Tubes for Boiler and Heat Exchanger

FLAME CuTTIng te la P is utting B c

NUCLEAR ENERGY RESEARCH INITIATIVE

NORSOK STANDARD M-650 Edition 4. Qualification of manufacturers of special materials

Integrated Computational Materials Engineering (ICME) for Steel Industry

Methods Commission CLUB DE LA SECURITE DE L INFORMATION FRANÇAIS. 30, rue Pierre Semard, PARIS

Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP)

Simulation of Residual Stresses in an Induction Hardened Roll

BODY OF KNOWLEDGE API-510 PRESSURE VESSEL INSPECTOR CERTIFICATION EXAMINATION

NEW METHOD TO DETECT COLD FUSION JOINTS IN HIGH DENSITY POLYETHYLENE PIPE

ABSTRACT. The Guidelines Section A is related to the general requirements of NSQ100 (Chapters 0, 1, 4, 5 and 6). Summary

TURBINE ENGINE LIFE MANAGEMENT App. N AIAA AIRCRAFT ENGINE DESIGN

ASTM A860/A860M-09 Standard Specification for Wrought High Strength. Ferritic Steel Butt Welding Fittings. 1. Scope :- 2. Reference Documents :-

11. NONDESTRUCTIVE TESTING

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

ROLLED STAINLESS STEEL PLATES, SECTIONS AND BARS

Health Care for Pipelines From Cradle to Grave

Pressure Vessel Assessment Report

Government Degree on the Safety of Nuclear Power Plants 717/2013

Numerical simulation of nondestructive testing, an advanced tool for safety analysis

ENIQ position on. NDE Personnel Re-qualification or a Need to Maintain Proficiency. ENIQ publication no. 49. December 2014

NON DESTRUCTIVE TESTING & ASNT WELD INSPECTION & AWS

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

NDT Procedure for Liquid Penetrant Inspection TRINITY NDT. An ISO 9001:2008 Certified Company

Outline of a quality system and standard for the certification of conformity

\ srl High Technology Gear Reducers and Cardan Shafts CERTIFIED QUALITY SYSTEM: UNI ISO EN 9001:2008 ICIM 2779/2; IQNET N. IT UNIVERSAL SHAFT

Course available 24/7 for up to six months from the date of purchase or until completion

Field Welding Inspection Guide

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

Butt Fusion Welding of HDPE Pipes Work Procedure

Stilling Well Recommendations

5.2. Vaporizers - Types and Usage

CERTIFICATION OF OFFSHORE MOORING CHAIN

Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections

LKL Staal BV Specialized in customer specific metallurgical components

JIS G3445 Carbon steel tubes for machine structural purposes

NDT Procedure for Liquid Penetrant Inspection

R000. Revision Summary Revision Number Date Description of Revisions R000 Feb. 18, 2011 Initial issue of the document.

Integration of a fin experiment into the undergraduate heat transfer laboratory

Part 1: Manual Ultrasonic Inspection

mgr inż. Rafał Kaczmarek (MSc Eng.), dr inż. Ryszard Krawczyk (PhD (DSc) Eng.) Częstochowa University of Technology, Welding Technology Department

August 24, 2009 NRC INSPECTION REPORT / AND NOTICE OF VIOLATION TO JAPAN STEEL WORKS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Ultrasonic Technique and Device for Residual Stress Measurement

Pressure vessel basics for all engineers

Petrochemical Refinery Maintenance. Complete Maintenance Solutions

a. Are the foundry s employees trained and familiar with portions of the system applicable to their position?

APPLICATION OF ULTRASONIC IMAGING TECHNIQUE AS STRUCTURAL HEALTH MONITORING TOOL FOR ASSESSMENT OF DEFECTS IN GLASS FIBER COMPOSITE STRUCTURES

Specification for Rotary Drill Stem Elements

INTERACTION OF LIQUID MOTION ON MOBILE TANK STRUCTURE

BODY OF KNOWLEDGE API-570 AUTHORIZED PIPING INSPECTOR CERTIFICATION EXAMINATION

Structural Integrity Analysis

Safety Analysis for Nuclear Power Plants

Injection molding equipment

Technical Challenges for Conversion of U.S. High-Performance Research Reactors (USHPRR)

Ultrasonic Guided Waves Evaluation of Trials for Pipeline Inspection

Handbook on the Ultrasonic Examination. Austenitic Welds

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

LABORATORY EXPERIMENTS TESTING OF MATERIALS

Transcription:

Flaw indications in the reactor pressure vessels of Doel 3 & Tihange 2 This note provides a summary of the information available on the 12th of October2012. 1. Purpose Summary of the available information and preliminary evaluation pertaining to the indications of defects found in the Doel 3 and Tihange 2 reactor pressure vessels. 2. Background Belgian nuclear power plants have been built and are operated following the American codes and regulations, transposed in the Belgian context. The reactor vessels of Doel 3 and Tihange 2 were ordered in 1974, so the ASME Code ed. 1973 (and addenda of 1974) was applicable. Some Complementary Applicable Conditions were also required in addition to those of the ASME Code. The reactor vessel has been installed in 1978. Belgian reactor pressure vessels (RPV) are inspected according to ASME XI. Since 1982, several in-service inspections have been performed on the vessel. Following the rules of the ASME Code Section XI, volumetric in-service-inspections of the beltline area are normally limited to the circumferential welds (there are no axial welds in the Belgian RPVs) and the surrounding heat affected zone and base material, within the limits set by the code. Additionally, as a result of the experience at Tricastin, inspections aiming at detecting possible underclad defects in the pressure vessel beltline region are planned for all Belgian plants. The first inspection of this kind took place at Doel 3 this summer. This inspection has also been performed at Tihange 2. Since the beginning of the operating, all volumetric in-service inspections of the reactor vessel have been carried out by the French company Intercontrôle, also in charge of the same inspections in France. The tool employed for these inspections has been upgraded continuously. Some indications have been noticed during these inservice inspections, but none being of the nature or of the scale of the phenomenon observed during the 2012 inspections. Doel 3 started operation in 1982. Tihange 2 started operation in 1983. Both NPPs are operated by Electrabel, part of the GDF-Suez Group. 3. Inspections performed at Doel 3 in June-July 2012 3.1 Description of the inspections performed Three successive inspections were performed in June-July 2012: 1. The regulatory inspection according to ASME XI, IWB-2500-1, which is restricted to the welds and surrounding material (HAZ, base material). This inspection was performed from the inside of the vessel, with the usual qualified procedure for inservice inspection. Those inspections encompass the full circumference and 100% of the wall thickness (in this case 205 mm), over a length of ½ t on both sides of the weld 1

(see ASME XI fig. IWB-2500-1). There is no significant evolution to mention with respect to the former inspection. 2. The complementary planned inspection aiming at detecting possible under clad defects which incidentally detected the defects under discussion, but no under clad defect as such using a specific qualified procedure was the first inspection of that kind in Belgium. The inspection was performed from the inside of the vessel. It covers the full circumference and the first 25 mm (including 8 mm of cladding) of the thickness, from the inside of the vessel. The height of the inspected zone is 4080 mm (starting from 3320mm under the vessel flange up to 7400 mm, thus covering the full height of the core). This means that cladded base material is inspected where no volumetric inservice inspection has been performed up to now. No under clad defect has been detected. See hereafter for other defects. 3. A supplementary inspection was performed to better detect and characterize the unexpected defects detected during the former inspection, through the whole thickness of the shells. This supplementary inspection makes use of the available UT-technique on site at that time, i.e. the one used for the regulatory inspection according to ASME XI, IWB-2500-1 (see 1.). It covers the full height of the forged vessel rings (which is slightly more than the previous inspection (see 2)) and 100% of the wall thickness. To characterize the defect indications, additional data have been numerically recorded for a region which is particularly affected by the observed phenomenon. This region is 1,5m height, 120 large, and 135mm deep. 3.2 UT-techniques and qualification The complementary inspection was performed using a UT technique qualified for detecting under clad defects, i.e. axially-oriented defects. The supplementary inspection was performed using the UT technique qualified to detect and size defects in the weld area (see 3.1.1 above). No formal demonstration according ASME XI appendix VIII has been done. Actually both inspection techniques have been qualified applying the ENIQ principles. For under clad defects, use was made of the qualification file for France, completed with specificities for Belgium reactors. For under clad defects, the qualification was performed using relevant test block with relevant defect simulations to demonstrate the measurement accuracy of the sizing capability and reliability. For the base material examination, no additional test blocks made from base material only were used. Everything is based on experience with weld examination procedure. The qualification includes procedure, personnel/operators and equipment. The tolerances that can be expected in defect sizing with the qualified procedures are as follows: Sub-clad defects : +/- 1 mm average Base material defects : +/- 3 mm average (same as for welds) 3.3 Results of the inspection performed to detect and characterize underclad defects (June 2012) According to the licensee no underclad defects were detected. The cladding itself is intact. 2

Nevertheless, 158 defect indications of an apparently different type were selected on the basis of the criteria used for by this UT-inspection, especially in one of the three forged rings (SA-508-cl.3). These indications appear to be a quasi-laminar type of flaw. The flaws are more or less parallel to the inner/outer surface of the pressure vessel (slopes up to 10 could be observed), located in and outside the inspected zone. Considering the fact that this inspection method is not qualified for detection at such locations nor for this (new) type of indications, precise information about shape or dimension was not available at this stage. A first evaluation shows that these subsurface flaws are almost circular in shape with a mean diameter of about 15 mm (maximum 30 mm), with a flaw density up to 40 indications per dm³. Obviously, it was not possible at this moment to justify these indications on a one-byone basis by means of an analytical evaluation according to the App. A of ASME XI code requirements. 3.4 Results of the supplementary inspection performed to detect and characterize base material defects detected in June 2012 (July 2012) Considering the limitations of the inspection method which revealed the presence of the defects in the base material, an inspection of the whole height of the RPV with the UTqualified method used to control the beltline welds has subsequently been performed. This inspection covered the whole thickness and the whole height of the RPV. The results of this supplementary inspection can be so far summarized as follows: This inspection confirms the presence of a large amount of quasi-laminar indications in the upper and lower shell rings. All these flaws have been analysed, and distribution of these flaws in function of their depths or of their sizes have been established. There is a marked disparity in the flaw densities between the upper and the lower shell rings. The core lower shell is the most affected with a total of 7776 indications. The core upper shell contains 931 indications. The other parts of the reactor vessel contain some indications, but to a lower extend, and these are of a different nature in the transition ring. The shape of the flaw distribution is very similar in both cases. The bulk of the indications are located in the base material, outside the weld regions, throughout a zone extending from about 30mm from the inner surface to one half of the RPV thickness. These flaw indications seem to be laminar in shape and have an average diameter of 10-14 mm, while some indications have diameters of more than 20-25 mm. 4. Inspections performed at Tihange 2 in September 2012 These inspections aimed to investigate the possible presence of flaws in the reactor pressure vessel of Tihange 2 that are similar to those detected in Doel 3, and to detect potential underclad defects. They encompassed the vessel flange, the welds, the nozzle shell, the upper and lower core shells, and the transition ring. No underclad cracks have been detected. Flaws similar to those detected at Doel 3 have been identified through the thickness of the shells. 3

A total of 2011 indications have been identified in the shells. More particularly: In the vessel flange shell (zones 1 to 3): no indications; In the upper core shell (zones 4 to 6): 1931 indications; In the lower core shell (zones 7 to 9): 80 indications. In the transition ring, no indications have been reported. In the flange, 19 indications have been identified. Inside the core shells, which are the most affected, flaws have been observed up to a depth of 100 mm from the inside surface. However, most of the flaws are located between 20 mm and 70 mm. As to the flaw dimensions, flaws up to 24 mm large have been observed (depending on the transducer). However, most flaws are smaller than 10 mm. 5. Current status of the investigations performed by the licensee 5.1 Overview of the investigations performed by the licensee The Licensee is currently finalizing the analysis of the inspection results of Tihange 2. In the absence of any other explanation at this stage, the licensee supposes the presence of fabrication defects, but does not exclude other explanations. Investigations were conducted to retrieve information pertaining to the fabrication and the associated controls. Investigations are underway to investigate various metallurgical aspects. Studies are being performed to analyse and, if possible, to validate and confirm the structural integrity of the vessel. A justification of the observed defects for further operation is required by the Belgian regulations, based on ASME XI, App. A. According to first evaluations made by the Licensee, alternative requirements will be necessary. The Licensee is investigating a. o. alternative rules for regrouping individual indications. A PTS study based on 10CFR50.61a is planned. 5.2 History of vessel fabrication: current status Different companies have participated in the fabrication stages of the reactor vessel. The raw material of the reactor shells has been supplied by Krupp, and the forging has been performed by Rotterdamsche Droogdok Maatschappij (RDM), a Dutch company having the ASME N-stamp. RDM has since gone bankrupt. The cladding and the assembling have then been performed by Cockerill for the lower part (two core shells, transition ring and bottom plate) and by Framatome for the upper part (RPV head, nozzle shell), and the final assembly. The upper and lower vessel rings of the Doel 3 and Tihange 2 RPVs were forged by the Rotterdam Droogdok Maatschappij (also referred to as Rotterdam Dockyards or RDM), at the same time and under the same contract. The fabrication of both RPVs took place in the same period, following the same requirements. Most of the fabrication steps have been documented, and most of this documentation has been retrieved by has been recovered by Electrabel and Tractebel Engineering (engineering studies). In this way, some data about the fabrication process of Krupp are known, such as chemical composition (and hydrogen in particular) of the blooms. However, some documents are lacking. Notably, detailed documentation about the first thermal treatment performed by RDM (which according to the LOFC has been 4

done), an intermediate UT inspection and some RDM specifications are lacking. On the other hand, the fabrication steps by RDM have been followed by Cockerill and the AIA, and the certificates proving the conformity with the fabrication specifications have been retrieved. Similar investigations have been carried out for Tihange 2. According to the licensee, the hydrogen contents in the shells of Tihange 2 are similar to those of Doel 3. 5.3 Inspection at the fabrication stage Inspections at the fabrication stages have been carried out following the rules of the ASME Code Section III, edition 1974. These inspections involved UT controls and volumetric examinations. These examinations were performed manually and from the external surface of the vessel. In addition to the ASME Code, the CCA imposed some complementary controls (for the welds in particular), but these didn t lead to the observation of indications. For the core upper shell, the first inspections carried out during the fabrication indicated the presence of a large zone containing acceptable indications. During the intermediate inspection, this affected zone has however not been observed anymore. During the final inspection, 12 flaws were observed, but it has been concluded that these flaws were acceptable according to the applicable criteria. For the core lower shell, only the documentation regarding the final inspections has been retrieved. During this final inspection, no flaws have been noticed. The inspections of 2012 were carried out from the inner surface of the vessel wall, and are more sensitive than the inspections performed during fabrication. Despite the extent of the observations, it is reasonable, according to the licensee, to believe that the flaws observed during the 2012 inspections would not necessarily have lead to reject the shells according to the applicable design criteria of the ASME Code. The licensee is currently evaluating to which extent the UT-procedures used during fabrication were able to detect and size flaws the type of which were found this year. 5.4 Metallurgical aspects: current status of the investigations The flaws would have appeared during fabrication. During the casting of the ingots, some segregation zones develop inevitably. These correspond to a modification in the content of some constituents, which locally implies a change of the physical properties. In this way, during the thermal treatments applied on the shells, hydrogen present in the material behaves differently according to the region it crosses. More specifically, during the cooling steps, hydrogen diffuses more into the segregation region, and accumulates there. If the initial hydrogen content is sufficient, the hydrogen accumulation may imply the formation of flaws. These flaws then appear in large numbers, with a flake shape. Dimensions are typically between 4 and 14 mm. These flaws are quasi-laminar for reasons related to the fabrication process. Moreover, for the reasons explained above, they are essentially located inside the segregation zones, which have a particular shape, starting near the surface of the wall, and diving into the wall progressively. All these elements seem in good agreement with the observations made during the inspections of June and July 2012 at Doel 3 and in September at Tihange 2. Experience gained since several decades shows that it is possible to avoid the formation of these flaws if the hydrogen content is kept below a certain level, if long annealing is applied, and if a dehydrogenation step is carried out. During the 5

fabrication of the shells of the Doel 3 and Tihange 2 reactor vessels, no trace of a dehydrogenation treatment at RDM can be found. According to the licensee, it is improbable that these flaws have evolved since their formation. Nevertheless, this aspect is being further investigated. In order to obtain more information on these flaws and on their behaviour, nondestructive and destructive examinations are foreseen on monsters which are affected by this phenomenon. 6. Actions taken by the Belgian Authorities Communication with foreign countries: preliminary IRS; direct contacts with Safety Authorities of foreign countries having RPVs fabricated by RDM. Review of the available information w.r.t. the fabrication of the Doel 3 and Tihange 2 RPVs. Preliminary evaluation of the approaches aiming at justifying the observed defects for further operation. International meeting aiming at informing selected foreign countries (Brussels, 16th of August) Different national and international working groups have been formed: 1) Regulatory expert working groups (with members of nuclear safety authorities or related organisations) will share information and experience on regulatory approaches and actions in relation with this issue, discuss actions to be considered in other countries, and to provide technical advice to Belgian nuclear safety authorities (FANC, Bel V, AIB Vinçotte) on specific topics / questions related to this issue. Three subgroups have been formed, dealing with Non-destructive Examination techniques (WG1), Metallurgical origin / root causes of the flaw indications (WG2) and Structural mechanics & fracture mechanics Approach for justification file (WG3) 2) A Scientific expert working group with Belgian scientific experts will support the Scientific Council of the FANC. 3) An Independent international expert review board will perform an independent technical review on the Doel 3 RPV issue. Its members were selected by the Federal Agency for Nuclear Control for their expertise in reactor vessel technology, fracture mechanics, ASME XI code evaluation, and probabilistic approach. Further contacts with the Licensee: the regulatory body has required the licensee to use a stepwise approach to evaluate this issue: o Step 1: Collection of all relevant information (construction file, previous inservice inspections, and detailed findings of 2012 in-service-inspection ) o Step 2: Explanation of origin of flaw indications o Step 3: Discussion of justification file for possible restart Step 3 will only start after evaluation of all relevant information related to steps 1&2 6