Line Interactive UPS



Similar documents
Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

User s Manual AURORA 1.2K/2.2K

How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Online UPS. PowerWalker VFI 1000R/1U

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Powerware 5110 UPS User s manual

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

User Manual 1K/2K/3K Online UPS

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

How To Use A Power Supply Unit (Upland)

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

USER MANUAL Online UPS 1K/2K/3K Rack

USER MANUAL Online UPS 1K/2K/3K

HP UPS R1500 Generation 3

Installation and Operation Back-UPS 1250, 1300, 1500

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

10000HXL31/15000HXL31/20000HXL31

350, 500, 650 and 1000 MODELS

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Home Solar Kit Owner s Manual. Model: HS

Single Day Alarm Clock with. Bluetooth and USB Play-through

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Back-UPS Pro 1300/1500 Installation and Operation

User s Manual Before using the inverter, you need to read and save the safety instructions.

Uninterruptible Power Supply

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

EKOS Cart. Instructions for Use

SPL 2-00/-01 OPERATION INSTRUCTIONS

esata External Storage

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Jarv Nmotion BTHL-201 Bluetooth Stereo Earbuds Users Guide

NeTYS PR VA

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

3000W Power Inverter

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Model #: SMART2200CRMXL

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

SMART Board 8055i and 8055i-SMP

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Operating Manual Remote Cost Control Monitor

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

UPS OPERATING INSTRUCTIONS PROTECT A. PROTECT A. 500 PROTECT A. 700

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

TIG INVERTER INSTRUCTION MANUAL

Indoor Remote Controlled Power Points

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Register your product and get support at. AS111. User manual

Internet Office UPS System Standby UPS for PCs, workstations and more

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Lithium Jump Starter and DC Power Source

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

UPS-2200R-HH/UPS-2200R-HHIP

Home Solar Kit Owner s Manual. Model: HS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Dehumidifier Users manual. For Models: DH45S DH65S

External Hard Drive esata & USB 2.0 Combo. User Guide English

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Alarm Clock USER GUIDE

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Internet Office 500VA Tower Standby 120V UPS with USB port

2013 VTech Printed in China US

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Portable Air Conditioner

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Energy Communication Unit (ECU)

Transcription:

EN Line Interactive UPS PowerMust 636 LCD (650VA), Line Int., Schuko PowerMust 848 LCD (850VA), Line Int., Schuko PowerMust 636 LCD (650VA), Line Int., IEC PowerMust 848 LCD (850VA), Line Int., IEC PowerMust 1260 LCD(1200VA), Line Int., IEC PowerMust 1590 LCD (1500VA), Line Int., IEC PowerMust 2212 LCD (2200VA), Line Int., IEC Quick Start Guide EN

Warranty & Service Information Thanks for buying this Mustek UPS product. Please follow the instructions in the product manual and if applicable the software installation manual, to have the maximum use of your product. Installing the software: If you products comes with software you will find a CD Rom in the box containing the software. Please follow the instructions when installing the software. You can download the software, manual and short reference manual at the following site: www.ups-software-download.com Warranty: As a manufacturer we provide a minimum of 1 year warranty on our product. However for the exact warranty period and the warranty terms you should contact your reseller as both the warranty period and the terms may vary per Country / Region. Problem solving: Please check the chapter in your manual (hardware and software) on problem solving. Additionally: Please check our website (www. Mustek.eu) regularly for updates of the software as well as Frequent Asked Questions (FAQ). If this not solve your problem please contact your reseller for advice. Service and Maintenance: If the product requires service or maintenance in the warranty period always contact your reseller for the procedures. If outside the warranty period we advise you the contact your reseller as well. In any case always make sure that service or maintenance on the product are performed by a qualified technician.

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models PowerMust LCD series that should be followed during installation and maintenance of the UPS and batteries. This product is specially designed for PCs and it is not recommended for use in any medical equipment, life-supporting system and other specific important equipment. Do not plug household appliances such as hair dryers, microwave ovens or vacuum cleaners to UPS. Do not attach a power strip or surge suppressor to the UPS. Do not plug the UPS into its own output. Connection to any other type of receptable other than two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes. To reduce risk of overheating the UPS, do not cover the UPS cooling vents. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water or excessive humidity and do not use it in any of the following environments: o Any area with combustible gas, corrosive substance or heavy dust. o Any area with extraordinarily high or low temperature (above 40 C or below 0 C) and humidity of more than 90%. o Any area exposed to direct sunshine or near any heating apparatus. o Any area with serious vibrations. o Outdoor. The utility power outlet shall be near the equipment and easily accessible. In the event of an emergency, press OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. The internal short circuiting of the UPS will lead to dangers such as electric shock or fire; therefore do not allow liquids or any foreign object to enter the UPS. No water containers (such as a water glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid such dangers as electric shock. Please do not use the UPS in excess of the rated load capacity. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Risk of electric shock, do not attempt to disassemble the unit. No user serviceable parts inside. Refer servicing to qualified service personnel. If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the utility power to UPS, switch ON ), once a month for 24 hours to avoid a full battery discharge. In case smoke is found coming out from the device, please cut off the power supply quickly and contact the distributor. The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is required, please contact the distributor. Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: o Remove watches, rings, or other metal objects from the hand. o Use tools with insulated handles and wear rubber gloves and boots.

o Do not lay tools or metal parts on top of batteries. o Disconnect charging source prior connecting or disconnecting batteries terminals. When replacing batteries, replace with the same type and number of the sealed lead-acid batteries. o Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools. o The battery must be replaced exclusively by qualified personnel (risk of shock). Prohibit users from their own battery replacement. Contact your reseller if need. The maximum ambient temperature rating is 40 C. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. Icon Φ on the rating label stands for phase symbol. This pluggable type An equipment with battery already installed by the supplier is operator installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. In the event that there is fire occurring in the vicinity, please use dry-power extinguishers. The use of liquid extinguishers may give rise to the danger of electric shock. This product complies with the safety and environmental regulations in EU. If the time arises to throw away your product, please recycle all the components possible. Batteries and rechargeable batteries are not to be disposed in your domestic waste! Please recycle them at your local recycling point. Together we can help to protect the environment. 1. Introduction PowerMust LCD series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliability. 2. Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built-in boost and buck AVR function DC Cold start function Auto restart while AC recovery. Provides AC Overload protection RJ11/RJ45 (in/out) LAN/Modem/Phone line protection

3. Package Contents You should have received the following items inside of package: For Schuko socket product - UPS Unit x 1 - Startup manual x 1 - Communication cable x 1 - Software CD For IEC socket product - UPS Unit x 1 - Startup manual x 1 - Communication cable x 1 - Software CD - AC Input Power cable x1 - IEC output cable x2 4. Product Overview 4.1 Front Panel 636 IEC(Schuko) & 848 IEC(Schuko) 1260 IEC & 1590 IEC & 2212 IEC 4.1.1 Display When LCD starts to work, it will display all information for 3 seconds. When in normal mode, it will display as below. When in AVR mode, it will display as below. And the mark will flicker every 1second. When in battery mode, it will display as below. And the mark will flicker every 1second. When in off charging mode, it will display as below. When in fault mode, it will display as below. FAULT character and 0 character only. Note: If I/P-V<40V,input voltage will display 000 Note: the output voltage always is displayed as 000 in off charging mode. 4.1.2 Load capacity level display: Indicate the percentage of UPS load capacity which is being used by the protected equipment. Each LCD level bar indicates a 25% of the total UPS output capacity. 4.1.3 Battery capacity definition: Indicate the amount of battery volume remaining. Each battery volume level bar indicates a 25% of total battery volume

4.1.4 When over load, the mark will flicker every 1second. 4.1.5 When battery low, the mark will flicker every 1second. 4.2 Back Panel: 636 Schuko / 848 Schuko 636 IEC / 848 IEC 1260 IEC 1590 IEC / 2212 IEC 5. Installation and Initial Startup Before installation, please inspect the unit. Be sure that nothing is damaged. I: Placement & Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the temperature exceeds 0-40 C and the humidity is over 0-90 % RH. II: Connect to Utility and Charge Plug in the AC input cord to the 2-pole, 3-wire grounded wall outlet. For the best results, we suggest charging the battery at least 6 hours with no load (no electrical devices such as computers, monitors, rtc.) connected before initial use. The unit charges its battery while connecting to the utility.

III: Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, and devices connected to the UPS will be protected by UPS unit. Do not attach a power strip or surge suppressor to the UPS. IV: Connect LAN cable, Modem or Phone line for Surge Protection Connect for example a single modem or phone line into surge-protected IN outlet on the back panel of the UPS unit. Connect from OUT outlet to the computer with another phone line cable. V: Connect USB Cable To monitor the UPS status, such as unattended UPS shutdown and start-up, by using bundled software, please connect the UPS and PC with USB cable included. NEVER connect a laser printer or scanner to the UPS unit, because in-rush current generated by motor s devices may cause the damage of the unit. VI: Turn On/Off the Unit Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch. 6. Audio Indicator Audible Alarm Sounding every 10 seconds Sounding every 1 second Sounding every 0.5 seconds continuous sounding Situation Battery Mode Battery Low Overload Faulty 7. Software Installation on your PC Connected by USB to a PC or notebook, the Software enables communication between the UPS and the computer. The UPS software monitors the status of the UPS, shuts down the system before the UPS is exhausted and can remotely observe the UPS via the Network (enabling users to manage their system more effectively). Upon AC failure or UPS battery low, UPS takes all necessary actions without intervention from the system administrator. In addition to automatic file saving and system shut-down functions, it can also send warning messages via pager, e-mail etc. Use the bundled CD and follow the on-screen instructions to install the software WinPower. Enter the following serial No. to install software: 511C1-01220-0100-478DF2A After the software is successfully installed, the communication with UPS has been established and a green icon will appear in the system tray. Double-click the icon to use the monitor software (as above). You can schedule UPS shutdown/start-up and monitor UPS status through PC. Detail instructions please refer to the e-manual in the software. Check http://www.ups-software-download.com/index.htm from time to time to get the latest version of monitoring software. 8. Trouble Shooting Symptom Possible Cause Remedy No LED display on the 1. Battery weak. 1. Charge battery up to 8 hours. front panel. 2. Battery defect. 2. Replace with the same type of battery. 3. Power switch is not pressed. 3. Press the power switch again.

Alarm buzzer beeps continuously when AC supply is normal. Overload of the UPS. Verify that the load matches the UPS capability specified in the specs. When power failure, back-1up time is shorten. 2. Battery voltage is too low. 2. Charge battery 8 hours or Overload of the UPS. 1. Remove some non-critical load. more. 3. Battery defect due to high temperature operation environment, or improper operation to battery. 3. Replace with the same type of battery. Mains normal but LED is Power cord is loose. Reconnect the power cord properly. flashing. If any abnormal situations occur that are not listed above, Please stop using the unit and contact your reseller for advice. When replacing the batteries, use batteries with exactly same specifications. The battery must be replaced exclusively by qualified personnel (risk of shock). Prohibit user replace battery by oneself. Please contact your reseller if need. 9. Specifications Model 636 Schuko 848 Schuko 636 IEC 848 IEC 1260 IEC 1590 IEC 2212 IEC CAPACITY 650VA / 360W 850VA / 480W 1200VA/600W 1500VA/900W 2200VA/1200W INPUT Voltage 220 VAC Voltage Range 162~268 VAC OUTPUT Voltage 220 VAC Voltage Regulation +/-10% (Battery mode) Frequency Range 50/60Hz Frequency Regulation ±1Hz (Battery mode) Transfer Time Typical 4-8ms Waveform Modified Sine Wave PROTECTION Full protection Discharge, overcharge and overload protection ENVIRONMENT Humidity 0-90 % RH @ 0 to 40 C (non-condensing) Noise Level Less than 40dB Software Monitoring Software WinPower (included) BATTERY Type & Number 12V/7Ah x 1 12V/9Ah x 1 12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 2 Charging Time 6 hours recover to 90% capacity Backup Time (est. 100W) 16 min 20 min 30 min 50 min 50 min PHYSICAL LCD Indicator LCD display Outlet 2 x DE or 4 x IEC 6 x IEC outlets Connector USB port, RJ11 Surge Protection USB port, RJ45 Surge Protection Dimension (DxWxH) 290mm x 100mm x 143mm 364mm x 139mm x 195 mm WEIGHT Net weight 4.4kg 5.2kg 8.9kg 10.4kg 10.4kg