How To Use A Power Supply Unit (Upu)



Similar documents
User s Manual AURORA 1.2K/2.2K

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Line Interactive UPS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Online UPS. PowerWalker VFI 1000R/1U

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

Powerware 5110 UPS User s manual

User Manual 1K/2K/3K Online UPS

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

350, 500, 650 and 1000 MODELS

USER MANUAL Online UPS 1K/2K/3K Rack

USER MANUAL Online UPS 1K/2K/3K

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

How To Use A Power Supply Unit (Upland)

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

10000HXL31/15000HXL31/20000HXL31

3000W Power Inverter

EKOS Cart. Instructions for Use

Home Solar Kit Owner s Manual. Model: HS

Installation and Operation Back-UPS 1250, 1300, 1500

HP UPS R1500 Generation 3

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

User s Manual Before using the inverter, you need to read and save the safety instructions.

SPL 2-00/-01 OPERATION INSTRUCTIONS

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Uninterruptible Power Supply

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Home Solar Kit Owner s Manual. Model: HS

Back-UPS Pro 1300/1500 Installation and Operation

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

USER MANUAL Online UPS 6K/10K RACK

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

2013 VTech Printed in China US

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Dehumidifier Users manual. For Models: DH45S DH65S

UPS-2200R-HH/UPS-2200R-HHIP

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

TIG INVERTER INSTRUCTION MANUAL

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

NeTYS PR VA

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Indoor Remote Controlled Power Points

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

400 Amp Rechargeable Jump Start System RAC-HP082

esata External Storage

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

Single Day Alarm Clock with. Bluetooth and USB Play-through

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Model #: SMART2200CRMXL

TMS TANK MANAGEMENT SYSTEM

Lithium Jump Starter and DC Power Source

Installation and Operating Instructions (for chargers shown below)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

PowerGem Pro Uninterruptible Power Supply

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

Operating Instructions

Manual for Fire Suppression & Methane Detection System

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User Manual (English)

Advantium 2 Plus Alarm

Installation and Operating Instructions (for chargers shown below)

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

How To Use A Sata Dsa Hard Disk Storage System

BroadBand PowerShield. User Manual

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Battery Power Inverters

UPS OPERATING INSTRUCTIONS PROTECT A. PROTECT A. 500 PROTECT A. 700

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Residential Gateway (RG) Battery Backup

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

30W SOLAR CHARGING STATION

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Emergency Response. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc.

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

1. User Safety Instructions

Spec. No. ICR C Version No. 0.0

VLT Series 300 Watt True Sine Wave Inverter

User Manual HomeGrid 3000 Solar Generator

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Transcription:

BRAVER UPS (Uninterruptible Power System) User s Manual

Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only authorized service personnel may perform repairs. Internal battery voltage is 12V DC. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes. In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in location where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of batteries in a fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminal.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions should be taken. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number of the sealed lead-acid batteries. The socket-outlet shall be installed near the equipment and easily accessible. With the installation of the UPS, it should be prevented that the sum of (UPS and) the connected (load) leakage current exceeds 3.5mA. This pluggable type A equipment with battery installed by the supplier is operator installable and may be operated by laymen. Attention!! Hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the connectors of the battery when maintenance or service work inside of the UPS is necessary.

System Description Front Panel 1. Power Switch & LED Indicator 2. LED Indicators -- AC Mode: Green Lighting Battery Mode: Yellow Flashing Fault Mode: Red Lighting 1. Power switch 2. LCD display

Back Panel 1. Output receptacles 2. AC Input with AC fuse 3. Modem/Phoneline Surge Protection 4. Communication Port

Installation and Operation Installing the UPS is as easy as following the steps shown. Be aware of the Power Switch must be kept in the ON position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS unit away from monitor at least 20cm to avoid interference. 3. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours.

4. Computer Connection Connect one computer-related device into each of the power receptacles supplied on the back of the UPS (maximum of three devices). 5. Modem / Phone line Connection Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Plug the other end to the modem input socket as shown.

6. Serial Cable Connection To allow for unattended system shutdown for your operating system, connect the RS-232 serial cable as per diagram below. 7. Turn On/Off To turn on the UPS, press power switch lightly. To turn off the UPS, please press power switch again. 8. DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. 9. Green Power Function Braver UPS is equipped with Green Power Function. For saving power and protecting battery, the method of deep discharging protection is adopted on inverter mode.

Software Installation WinPower-XP WinPower-XP is a UPS monitoring software, which provides user-friendly interface to monitor and control your UPS.

Trouble Shooting Symptom Possible Cause Remedy No LED display 1. Battery weak. 1. Re-charge battery up to 8 hours. on the front 2. Battery defect. 2. Replace with the same type of panel. battery. 3. Power switch is not 3. Press the power switch again. pressed. Alarm buzzer beeps continuously when AC supply is normal. When power failure, backup time is shorten. Communication lost between UPS and computer. Mains normal but orange LED is on. Overload of the UPS. Verify that the load matches the UPS capability specified in the specs. 1. Overload of the UPS. 1. Remove some non-critical load. 2. Battery voltage is too low. 2. Charge battery 8 hours or more. 3. Battery defect due to high temperature operation environment, or improper operation to battery. 1. Software is not installed well. 2. Cable is not properly connected. 3. Replace with the same type of battery. 1. Check the setting of the software. 2. Check the RS-232 cable is firmly connected to COM1/COM2 of the computer and confirm the setting again. 1. Fuse is blown. 1. Replace the same type of fuse. 2. Power cord is loose. 2. Reconnect the power cord properly. 3. Battery defect. 3. Replace the same type of battery. If any abnormal situations occur that are not listed above, please call service people immediately.

Specifications MODEL Braver UPS CAPACITY VA 400VA 600VA 800VA Voltage Range 170-280V AC Frequency 40Hz above Voltage 230V AC Voltage Regulation (Battery Mode) + / - 10% Frequency 50Hz or 60Hz OUTPUT Frequency Regulation + / - 1 Hz (Battery Mode) Output Waveform Modified Sinewave BATTERY Battery Type 12V, 4.5Ah 12V, 7Ah 12V, 9Ah Recharge Time 8 hours to 90% after complete discharge TRANSFER TIME Typical 4-8ms INDICATOR AC Mode Green light Backup Mode Orange light flashing Backup Mode Beeping every 10 seconds Low Battery Beeping every second AUDIBLE ALARM Overload Beeping every 0.5 seconds Battery Defect Beeping every 2 seconds Fault Continuously Beeping PROTECTION Full Protection Discharge, overcharge, and overload protection PHYSICAL ENVIRONMENT INTERFACE Dimension (mm), D x W x H 330 x 100 x 140 mm Net Weight 5 kgs 6kgs 6.5kgs Operating 40, 0-90 % relative humidity Environment (non-condensing) Noise Level Less than 40dB Smart RS-232 yes USB Optional