SHEET. ARCNET Hub with USB Interface ARCNET. AI-USB Series. Features:

Similar documents
SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

PCI20EX INSTALLATION GUIDE INTRODUCTION. PCI Express (PCIe) Bus ARCNET Network Interface Modules

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

ANA: ARCNET Network Analyzer

BASRT-B. BACnet/IP to MS/TP Router. Installation Guide. TD ID For Firmware Versions 1.x

Rack mounted telephone- and leased line modem for industrial applications

Waveguide Access Point WGA631. Product Guide

Telephone- and leased line modem for industrial applications TD-36

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Have your JACE also monitor your Ethernet network

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ADACSNET USB Control Module

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Edgeport/E USB ETHERNET ADAPTER. Installation Guide. Model: Edgeport/E

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

BASRT-B. BAS Router. BACnet Multi-network Router. Installation Guide. TD IH For Firmware Versions 2.x

PCS0100en Persy Control Services B.V. Netherlands

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

1-Port R422/485 Serial PCIe Card

Cisco Unified IP Phone Power Injector

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Disturbance Recoder SPCR 8C27. Product Guide

38 Series - Relay interface modules A

Dual Chamber Temporary External Pacemaker

Chassis, Power Supply, and Element Management

485USBTB-2W & 485USBTB-4W

TrueAlarm Fire Alarm Systems

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

T200, PTP/IEEE 1588 Grandmaster Clock and

Hi-Speed USB Port Hub Connect up to 7 Hi-Speed USB 2.0 or USB 1.1 devices

Digital input modules

NetScanner System. Toronto: , Montreal: , Toll Free: ,

USER MANUAL VS92A / VS94A / VS98A

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Long Reach PoE over Coaxial Extender Kit

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

38 Series - Relay interface modules A

Indoor / Outdoor Antenna

15 Series - Electronic step relay and dimmer. Features SERIE

ZC-24DO CANopen I/O Module: 24 Digital Outputs

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

RC-1SP4T-A18. Key Features. Mini-Circuits P.O. Box 35166, Brooklyn, NY (718)

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

STRATO LED Drivers 70W, Single output

Application Server V240 Platform

TX OPEN RS232/485 module

DC Electronic Loads 8500 series

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Portable BACnet /IP to MS/TP Router

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

80 Series - Modular timers 16 A. Features

Chapter 5 Cubix XP4 Blade Server

TEST REPORT EN (1997) +A1 (2001)

EMC Test for Compliance with EU EMC Directive 2004/108/EU

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

FlexPoint T1/E1 Copper to Fiber Line Driver

Energy Management Energy Meter Type EM23 DIN

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

NEW. EVEN MORE data acquisition and test stand automation

Network Design. Yiannos Mylonas

Unidirectional Transmitter/ Receiver Units Introduction

T1 Backhaul Connectivity Solution All Products :: Application Note

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

USB 2.0 Hi-Speed 4-Port Hub User Manual

USB Port Extender Kit

GEU Port Gigabit Switch

NC-12 Modbus Application

PE10G2T Dual Port Fiber 10 Gigabit Ethernet TOE PCI Express Server Adapter Broadcom based

MasterINTERFACE 39 Series - Relay interface modules

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Loop-IP6700 TDMoEthernet

OZW30. Central Unit SYNERGYR

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

EKI port Industrial Unmanaged Gigabit Ethernet Switch. User Manual

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

HARTING econ 3000 Introduction and features

HDMI / Video Wall over IP Transmitter with PoE

LT-82 Stationary IR Transmitter

Transcription:

AI-USB Series d a t a SHEET ARCNET Hub with USB Interface The AI-USB hub alters how you connect to an ARCNET network. It gives you easy access to the network via a PC without removing the cover. It helps to prevent any service technician aggravation because it eliminates the installation of an ARCNET card in the PC. This is an active hub with similar hub functionality as an AI Series hub, but it allows access to the Universal Serial Bus (USB) to a host PC. It has three ports two external and one internal. The internal port has a connection to a USB adapter (network interface module) resident in the AI-USB. The USB connection is brought out to the front panel so a laptop or desktop computer can gain Plug-and-Play (PnP) access to an ARCNET network. This unit conforms to the high-speed USB 2.0 standard. It is a very fast and convenient method of accessing an ARCNET network without the need of removing a cover and installing a network interface module into a computer. Today, most computers are equipped with a USB port so it is only necessary to make a connection between the computer and the AI-USB. It also operates with the earlier lower-speed USB 1.1 standard. An ideal application for the AI-USB is temporary access to an ARCNET network by simply hooking from a laptop computer using its USB port. With the AI-USB permanently connected to the ARCNET network, field wiring is not disturbed when attaching the USB cable. Thus, an ARCNET network can be monitored, stations configured and troubleshooting can be accomplished with minimal disruption to the network. With two external hub ports, the AI-USB can be inserted between two bus segments and function as a bus extender. Models are available for coaxial bus, twisted-pair bus and both AC- and DC-coupled EIA-485 Features: Functions as both a hub and a USB interface to the ARCNET network Exchanges ARCNET packets with a USB-connected computer Two external hub ports for expansion Supports coaxial and twisted-pair including AC- and DC-coupled EIA-485 Operates with either the USB 1.1 or 2.0 standard Incorporates a COM20022 ARCNET controller chip LEDs identify reconfigurations and port activity Minimizes bit jitter with precision delay-line timing Low-voltage AC- or DC-powered CE Mark RoHS compliant Embedded microcontroller provides 128 Kbytes of receiver buffering ARCNET DS-AIUSB000-BA0

When the USB cable is first attached to a Windows machine, you are prompted for a driver on a disk. We offer a USB driver and a DLL with an API (Application Programming Interface) compatible with our Null Stack Driver API. By avoiding a protocol stack, a null stack driver out performs a layered protocol stack by directly linking the app to the ARCNET hardware beneficial for timely access to a real-time network like ARCNET. The USB adapter in the AI-USB consists of a high-speed microcontroller and a COM20022 ARCNET controller. Each unit provides 128 Kbytes of ARCNET receiver buffering greatly aiding the reception of broadcast messages. With a 400 Mbps USB link, the potential of dropping ARCNET packets is remote. The AI-USB has the same connector as the AI Series of hubs. The unit can be powered from a wide range of low-voltage AC or DC power sources and provisions exist for redundant power connections. It is shipped with a CD containing Windows compatible software and a USB cable. Transceiver Options Model number suffixes indicate the various transceiver types. -CXS Coaxial Star Most ARCNET networks use RG-62/u coaxial cable (with BNC connectors) in a star topology where each NIM connects directly to a port on an AI hub. But the coaxial star configuration provides the longest coaxial distance and simplifies troubleshooting. This port terminates a coaxial segment without requiring a passive terminator. -TB5 Twisted-Pair Bus Twisted-pair can be used in a bus and dual RJ-45 jacks support a daisy-chain. Distances and node count are limited. Passive terminators are inserted in unused jacks at each far end of the segment. Shielded as well as unshielded cable is supported. -485 DC-Coupled EIA-485 A shielded or unshielded EIA-485 twisted-pair can support several nodes over a limited distance. Screw terminals permit a daisy-chain segment. EIA-485 offers a hubless solution but with limited distance and low common mode breakdown voltage. Segments can be extended with AI repeaters and hubs and each port accommodates failsafe bias and cable termination. -485X AC-Coupled EIA-485 The EIA-485 transformer-coupled option provides the convenience of EIA-485 connectivity but with a much higher common mode breakdown voltage. The -485X option eliminates the phase reversal issue of the -485 option, but distance and node count are lower. Diagnostic LEDs for quick and easy troubleshooting Versatile ARCNET Cabling Support Twisted-pair (not shown) Coaxial Extendable Brackets allow panel mounting in lieu of DIN-rail Detachable Power Plug for easy field service DS-AIUSB000-BA0 Page 2

Mechanical Diagram Power Diagrams DS-AIUSB000-BA0 Page 3

Specifications Electrical Input DC AC Voltage 10 36 VDC 8 24 VAC Power 5 W 5 VA Frequency N/A 47 63 Hz Environmental/Mechanical Operating temperature 0 C to 60 C Storage temperature 40 C to +85 C Relative humidity 10 95%, non-condensing Protection IP30 Functionality Data rates Transceiver Data Rates 485 78 kbps to 10 Mbps 485X 1.25 Mbps to 10 Mbps CXS, TB5 2.5 Mbps Extended timeouts Supports all three extended ARCNET timeouts Hub, repeaters and link delay 320 ns max at 2.5 Mbps Unlatch delay time 5.9 μs max at 2.5 Mbps Compliance ATA 878.1-1999 LED indicators RECON yellow ACTIVITY green STATUS green Regulatory Compliance CE Mark RoHS CFR 47, Part 15 Class A Permissible Cable Lengths and Nodes Per Segment (2.5 Mbps) Transceiver Description Cable Connectors Cable Length Max Nodes Notes Min Max Bus Segment -485 DC-coupled EIA-485 IBM type 3 screw 0 274 m (900 ft) 17 DC coupled -485X AC-coupled EIA-485 IBM type 3 screw 0 213 m (700 ft) 13 Transformer isolated -CXS Coaxial star RG-59/u BNC 0 457 m (1500 ft) N/A 7.0 db/1000 ft max -CXS Coaxial star RG-62/u BNC 0 610 m (2000 ft) N/A 5.5 db/1000 ft max -TB5 Twisted-pair bus IBM type 3 RJ-45 6 ft / 2 m 1 122 m (400 ft) 8 For dipulse signalling 1 This represents the minimum distance between any two nodes or between a node and a hub. DS-AIUSB000-BA0 Page 4

Data Sheet AI Series Electromagnetic Compatibility Standard Test Method Description Test Levels EN 55024 EN 61000-4-2 Electrostatic Discharge 6 kv contact, 8 kv air EN 55024 EN 61000-4-3 Radiated Immunity 10 V/m, 80 MHz to 1 GHz EN 55024 EN 61000-4-4 Fast Transient Burst 1 kv clamp, 2 kv direct EN 55024 EN 61000-4-5 Voltage Surge 1 kv L-L, 2 kv L-Earth EN 55024 EN 61000-4-6 Conducted Immunity 10 Volts (rms) EN 55024 EN 61000-4-11 Voltage Dips & Interruptions 1 Line Cycle, 1 to 5 s @ 100% dip EN 55022 CISPR 22 Radiated Emissions Class A EN 55022 CISPR 22 Conducted Emissions Class A CFR 47, Part 15 ANSI C63-4 Radiated Emissions Class A Typical Installation The AI-USB/CXB will accommodate either a star or bus topology. When using coaxial bus (-CXB) adapters, terminate the far end of the bus segment, but do not terminate the AI-USB port. Star connections never use terminators nor BNC T connectors. Ordering Information Model AI-USB-485 AI-USB-485X AI-USB-CXS AI-USB-TB5 Accessories Model AI-XFMR AI-XFMR-E Description USB interface with two DC-coupled EIA-485 ports USB interface with two AC-coupled EIA-485 ports USB interface with two coaxial star ports USB interface with two twisted-pair ports Description Wall-mount plug-in transformer, 120 VAC input/24 VAC output (nominal values) Wall-mount plug-in transformer, 230 VAC input/24 VAC output (nominal values) United States Contemporary Control Systems, Inc. 2431 Curtiss Street Downers Grove, IL 60515 USA China Contemporary Controls (Suzhou) Co. Ltd 11 Huoju Road Science & Technology Industrial Park New District, Suzhou PR China 215009 United Kingdom Contemporary Controls Ltd 14 Bow Court Fletchworth Gate Coventry CV5 6SP United Kingdom Germany Contemporary Controls GmbH Fuggerstraße 1 B 04158 Leipzig Germany Tel: +1 630 963 7070 Fax:+1 630 963 0109 Tel: +86 512 68095866 Fax: +86 512 68093760 Tel: +44 (0)24 7641 3786 Fax:+44 (0)24 7641 3923 Tel: +49 341 520359 0 Fax: +49 341 520359 16 info@ccontrols.com www.ccontrols.com info@ccontrols.com.cn www.ccontrols.asia info@ccontrols.co.uk www.ccontrols.eu info@ccontrols.de www.ccontrols.eu DS-AIUSB000-BA0 December 2013 Page 5