SECTION THERMOPLASTIC RAILINGS. A. Thermoplastic handrails and railings, including connectors, fasteners, and system required accessories.

Similar documents
SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

SECTION WINDOW WASHING SYSTEMS

Product Guide Specification

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS CENTERFOLD

Residential Deck Safety, Construction, and Repair

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION GUARDA SECURITY WINDOW SCREENS

ATI Evaluation Service A Division of Architectural Testing Certification Services

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

PART 1 GENERAL 1.1 SECTION INCLUDES

Simplified Steel Stair Design for Commercial and Institutional Buildings

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION STANDING SEAM METAL ROOFING

CLEAR-DIVISIONS VARIOFOLD

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

AZEK Rail Install Guide

3-Part Specification Railing Cable Systems

glass & Glazing Products

SECTION PREFORMED METAL STANDING SEAM ROOFING

SECTION STORM DRAINAGE SYSTEM

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

PART E SPECIFICATIONS

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Design of Commercial/Industrial Guardrail Systems for Fall Protection

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

RadianceRail Installation Guide

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

UNIVERSAL RAILING, STEEL

Wastewater Capital Projects Management Standard Construction Specification

1. Preassembled steel stairs with concrete-filled treads. 2. Handrails attached to walls adjacent to metal stairs.

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: LandMarke Railing System. PVC Guardrail System "Patent Number 7,487,941"

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

ENTRANCE MATS & GRIDS

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Preformed Metal Roofing and Siding

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Dubai Municipality Standard DMS 1: Part 5: 2004

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Embedded Parts Introduction - Anchors

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

SECTION CHAIN LINK FENCES AND GATES

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

SPIRAL STAIR KIT INSTALLATION MANUAL

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

POST AND FRAME STRUCTURES (Pole Barns)

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

City of San Diego, CWP Guidelines

SECTION GROUND WATER STORAGE TANKS

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Wisconsin Building Products Evaluation

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

SECTION PRECAST CONCRETE UTILITY STRUCTURES

SECTION PRECAST CONCRETE STRUCTURES

SECTION 1 GENERAL REQUIREMENTS

2. Division 05 Structural Steel Framing for steel framework requirements

LAYING BLOCK AND BRICK

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

COMMONLY USED RESIDENTIAL BUILDING CODES

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

Packaged Terminal Air Conditioner Wall Sleeve Installation

AZEK Rail Install Guide

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

DIVISION 4300 STORM DRAINAGE

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Roof Curbs, Extensions and Equipment Supports

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

LiftAlloy Chain Slings

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Division 9. SignaFlor Pad and Pour Flooring System

CONTENTS 1. INTRODUCTION METHODOLOGY RESULTS & FINDINGS...9 APPENDIX

Mark Cramer Inspection Services, Inc.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SECTION GUARDRAILS

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Fiberglas, Exterior Wall Thermal Insulation

Transcription:

SECTION 05520 THERMOPLASTIC RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Thermoplastic handrails and railings, including connectors, fasteners, and system required accessories. 1.2 RELATED SECTIONS A. Section 03410 - Plant Precast Structural Concrete. B. Section 05520 - Handrails and Railings: Handrails other than decorative handrails specified in this Section. 1.3 REFERENCES A. ASTM D 256 - Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics. B. ASTM D 638 - Standard Test Method for Tensile Properties of Plastics. C. ASTM D 648 - Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position. D. ASTM D 695 - Standard Test Method for Compressive Properties of Rigid Plastics. E. ASTM D 790 - Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating materials. F. ASTM D 792 - Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement. G. ASTM D 870 - Standard Practice for Testing Water Resistance of Coatings Using Water Immersion; 1992. H. ASTM D 2247 - Standard Practice for Testing Water Resistance of Coatings in 100% Humidity; 1994. I. ASTM D 2794 - Standard Test Method for Resistance of Organic Coatings to the Effect of Rapid Deformation (Impact); 1993. 1.4 SYSTEM DESCRIPTION A. Performance Requirements: Comply with loading capacity required by Code applicable in the jurisdiction of the Project. B. Physical Properties of Thermoplastic Tubing: As follows, when tested per standards referenced: 1. Specific Gravity: 1.44 per ASTM D792. 2. Compressive Strength: 8,100 psi (56 MPa) per ASTM D695. 05521-1

3. Flexural Strength: 11,100 psi (76 MPa) per ASTM D790. 4. Tensile Strength: 6,000 psi (41 MPa) per ASTM D638. 5. Flexural Modulus: 406,000 psi (2799 MPa) per ASTM D790. 6. Tensile Modulus: 355,000 psi (2448 MPa) per ASTM D638. 7. IZOD Impact - Notched: 17 pound-force per inch per ASTM D256. 8. Heat Deflection: 264 psi (2 MPa) per ASTM D648. C. Testing: 1. Provide compounds used in manufacture of railing components that have undergone extensive outdoor testing, for minimum of 24 consecutive months, in climates representing extremes encountered in continental United States as follows. Results of testing shall remain within parameters established for exterior applications by manufacturer of compound: a. Arizona (hot and dry). b. Florida (hot and wet). c. New York (freeze/thaw, pollutants). D. Structural Performance of Top Rails and Supports: 1. Capable of withstanding a concentrated load of 200 pounds (90.6 kg), applied to top rail at any point and in any direction. 2. Capable of withstanding a uniform load of 50 pounds per linear foot (74.3 kg/m) applied to the top rail horizontally with a simultaneous load of 100 pounds per linear foot (148.6 kg/m) applied vertically downward. 3. Design need not provide for both concentrated and uniform loads to be applied concurrently. E. Structural Performance of Guardrail Infill: 1. Capable of withstanding a horizontal concentrated load of 200 pounds (90.6 kg), applied to a 1-foot (30.5 mm) square area at any point on infill. 2. Infill is defined to include panels, intermediate rails, balusters, and other elements. 3. Design need not provide for infill loads to be applied concurrently with top rail loads. F. Design Requirements: 1. Integrity of wall thickness: Do not compromise wall thickness at any location throughout system by milling, drilling, non-extruded fittings (crosses, tees, elbows, etc.) or other manufacturing or molding process. 1.5 SUBMITTALS A. Submit under provisions of Section 01300. B. [ [ Product Data ] ]: For each type of product specified. C. Shop Drawings: Showing fabrication and installation of handrails and railings including plans, elevations, sections, details of components, and attachments to other Work, if required. D. Samples for Verification: Provide Samples of each type of exposed finish required, prepared on components indicated below that are of same thickness and metal indicated for final unit of Work. Where finishes involve normal color and texture variations, include Sample sets showing full range of variations expected. 1. 6-inch long sections of each distinctly different linear railing member including handrails, top rails, posts, and balusters. 2. Brackets and/or miscellaneous attachment accessories. E. Product test reports from qualified independent test laboratory evidencing compliance of railing components and systems width requirements based on comprehensive testing of 05521-2

current products. F. Weathering performance data substantiating product performance. G. Research Reports or evaluation reports of model code organization acceptable to authorities having jurisdiction that evidence railing system's compliance with building code in effect for Project. H. Qualification Data: For firms and persons specified in Quality Assurance Article to demonstrate their capabilities and experience. Include list of completed projects with project names, addresses, names of architects and owners, plus other information specified. 1.6 QUALITY ASSURANCE A. Manufacturer's Qualifications: Firm that has produced types of handrail and railing systems required for not less then 10 years, with not less than 5 similar projects that have been successful use for not less than 5 years. B. Installer Qualifications: Minimum 2 years experience in successful installation of stair and railing systems of type specified or trained by manufacturer. 1.7 PROJECT CONDITIONS A. Field Measurements: Where handrails are indicated to fit other construction, check actual dimensions of other construction by actual field measurements before fabrication. Indicate recorded measurements on approved Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delay of Work. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Advanced Products, llc (AVCON), which is located at: 1915 Swarthmore Avenue; Lakewood, NJ 08701; Toll Free Tel: 800 RAILING (724-5464); Tel: 732-286-9496; Fax: 732-286-0526; Email: info@avcon.com; Web: www.avcon.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 PRODUCTS A. Classic Series: 1. Daytona. 2. Malibu. 3. Cape Cod. 4. Harbor Master 1-8 lines. B. Original Series: 1. Sentry. 2. Protector. 3. Cavalier. 4. Continental 1-8 lines. C. Freedom Series: 1. Guardian. 2. Defender. 05521-3

D. Railing Infill Type: 1. Pickets: 1 inch (25 mm) tubing OD. 2. Horizontal Rails: 2 inch (51 mm) tubing OD. 3. Glass: 3/8 inch (9 mm) thick. 4. Trespa Panel: 3/8 inch (9 mm) thick. 5. Decorative Panel: Decorative infill panel. 6. Lattice Panel: Triple lattice panel. E. Railing Height: 1. Height: 6 inches (152 mm). 2. Height: 12 inches (305 mm). 3. Height: 24 inches (610 mm). 4. Height: 36 inches (914 mm). 5. Height: 42 inches (1067 mm). 6. Height: 48 inches (1219 mm). 7. Height: 72 inches (1229 mm). 2.3 MATERIALS A. Tubing Components: Tubing consists of high-impact, outdoor weather-resistant tubing components fabricated from acrylonitrile styrene acrylate (ASA), specially formulated with specific stabilizers and modifiers for strength, durability, ultraviolet light protection, and with inhibitors for expansion and contraction. 1. Use compounds that have undergone testing demonstrating that resins are dimensionally stable, fade resistant, and retentive of key physical engineering properties, and that support color retention and stability, mechanical property retention including impact, and tensile strength. 2.4 COMPONENTS A. Top, Intermediate, and Bottom Rails: 1. Rails: 2 inch outside diameter tubing with nominal wall of 5/16 inch (8 mm). 2. Posts: 2 inch outside diameter tubing with nominal wall of 5/16 inch (8 mm). 3. Posts: Larger diameter steel pipe reinforcing, alternately reducing wall thickness of thermoplastic tubing, maintaining 2 inches outside diameter. B. Wall Mounted Handrail and Handgrip Portion of Handrail: 1. Handrail: 2 inch (51 mm) OD diameter tubing with nominal wall thickness of 5/16 inch (8 mm). 2. Handrail: 1-1/2 inch (38 mm) OD diameter tubing with nominal wall thickness of 5/16 inch (8 mm). C. Guardrail Infill System: Consists of intermediate rail balusters with 1-1/16 inch (27 mm) OD tubing and nominal wall thickness of 5/32 inch (4 mm). 1. Aluminum Reinforcement: Reinforce vertical balusters in Daytona railing heights in excess of 42 inches (1067 mm). 2. Steel Reinforcement: Reinforce vertical balusters in excess of 36 inches (914 mm) in height with internal metal stiffener. 3. Steel Pipe Reinforcement: Provide standard weight schedule 40 galvanized steel pipe, ASTM A53, Type F, at the following locations: a. Railing posts and top horizontal rail of styles that do not contain balusters. 4. Rail Reinforcement: Reinforce horizontal rails (exclusive of radius railing) where balusters are inserted, reinforce with heavy gauge extruded aluminum designed to allow insertion of the balusters. D. Post Mounting: Minimum of 5/16 inch (8 mm) thick galvanized steel, pre drilled for fasteners. Provide the following mounting configuration: 05521-4

2.5 ACCESSORIES 1. Surface mounted flange plate. 2. Core mount. 3. Fascia mount. 4. Weld mount. A. Brackets, Flanges, and Fittings: Same material as primary railing components. B. Anchors and Inserts: Galvanized or stainless steel, expansion type; capable of withstanding structural design loads specified. C. Screws: Galvanized or stainless steel, 18-8 alloy, non-magnetic. D. Balcony Separators: Manufacturer's aluminum fasteners designed to hold separation panels between 1/4 inch (6 mm) and 5/16 inch (8 mm) thick. E. Grout: Non-shrink Portland cement-based hydraulic grout, mixed and applied per manufacturer's instructions; no gypsum grout allowed. 2.6 FABRICATION A. General: Fabricate handrails and railing systems to comply with requirements indicated for design, dimensions, details, finish, and member sizes, including wall thickness of members, post spacing, and anchorage, but not less than those required to support structural loads. B. Pre-assemble railing systems in shop to greatest extent possible to minimize field splicing and assembly. Disassemble units only as necessary for shipping and handling limitations. Use connections that maintain structural value of joined pieces. Clearly mark units for reassembling and coordinated installation. C. Posts: 1. Post Assembly: Fabricate from one continuous length of tubing running continually from deck-mounting surface to top of railing assembly. Provide posts without seams, joints, or other interruptions. 2. Angle Posts: Fabricate from reinforced tubing located between horizontal railing members and designed to allow for continuous flow of horizontal railing members. Design intermediate post members to fit snugly on horizontal rails, free from seams and joints. D. Non-Welded Connections: At horizontal railing members, fabricate system for connection of sections by means of railing manufacturer's specially designed dual lock connector. Size connector to accommodate inside diameter of exterior railing member. Once connected, make final connection using 1/8 inch (3 mm) diameter stainless steel sleeve pin placed in appropriate sized pre-drilled hole. Once installed, fill hole with non-shrink silicone. E. Expansion Joint: Provide for an expansion joint to top horizontal rail where sections are field joined. Incorporate internal sleeve that is independent of outer tubing or internal steel. 1. Color of Expansion Sleeve: Match outer tubing color. F. Expansion Collars: Where appropriate, incorporate use of expansion collars at points where rails terminate at posts, top horizontal rail, or both. Obtain approval of local authority prior to use. G. Provide inserts and other anchorage devices for connection handrails and railing systems to concrete or masonry work. Fabricate anchorage devices capable of withstanding loading imposed by handrail and railing systems. Coordinate anchorage devices with supporting structure. 05521-5

2.7 FINISHES A. Thermoplastic Finish and Color: Smooth finish in color as selected by Architect from Manufacturer's stocking color choices. 1. Color: Selected by Architect from manufacturer's standard color selections. 2. Color: Black. 3. Color: White. 4. Color: Gray. 5. Color: Brown. 6. Color: Custom color. B. Base Flange Plate Coatings: Based on ASTM B633 for coatings applied to iron and steel. 1. Type 2: With colored chromate conversion coatings. 2. Classification Number: Fe/Zn 25. 3. Minimum Thickness: 25 micrometers. 4. Service Condition: SC 4 Exposure to harsh conditions, or subject to frequent exposure to moisture, cleaners, and saline solutions, plus likely damage by denting, scratching, or abrasive wear. PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until substrates have been properly prepared. B. Verify that reinforcement and anchoring devices are the correct type, have been located correctly, and have been installed properly. C. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Coordinate drawings, diagrams, templates, instruction, and directions for installation of anchors, such as sleeves, concrete inserts, anchor bolts, and miscellaneous items having integral anchors, that are to be embedded in concrete as masonry construction. 1. Manufacturer shall supply all integral hardware for connection of handrail and railing to each other. 2. Provide hardware needed to connect handrail or railing to adjoining structures. Coordinate delivery of such items to Project site. 3.3 INSTALLATION GENERAL A. Fit sections accurately together. B. Set handrails and railings accurately in location, alignment, and elevation, measured from established lines and levels and free from rack. Do not cut or abrade surfaces of handrails and railing components. C. Install handrails and railings systems to comply with railing manufacturer's instructions. D. Fastening To In-Place Construction: Provide anchorage devices and fasteners where necessary for securing handrails and railings to existing construction. 3.4 INSTALLATION - POSTS A. Adjust handrails and railing systems prior to anchoring to ensure matching alignment. Space posts at intervals indicated but not greater than that required by design loading. 05521-6

B. Anchor posts in concrete by core drilling holes not less than 4 inches (102 mm) deep and I inch (25 mm) greater that outside diameter of post. Clean holes of loose material and insert posts. Fill annular space between post and concrete with non-shrink, non-metallic grout as specified in Part 2 above, mixed and poured to comply with anchoring material manufacturer's directions. C. Anchor posts onto mounting surface by means of railing manufacturer's recommended method, including specified mounting or other means of anchorage as determined by railing manufacturer. 3.5 CLEANING A. Remove manufacturer's protective covering from exposed surfaces not more than 24 hours after installation in hot and humid climates and before final inspection. B. Clean surfaces as required, following procedures and employing cleaning materials as recommended by accessories manufacturer. 3.6 PROTECTION A. Protect installed products from damage by subsequent construction activities, until completion of Project. B. Field repair of damaged product finishes is limited to surface scratch repairs only. Use manufactures suggested field repair procedure only. Replace products that have been structurally damaged by subsequent construction activities. END OF SECTION 05521-7