High-resolution camera for SAM: instrument manual

Similar documents
Alpy guiding User Guide. Olivier Thizy François Cochard

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Fig.1. The DAWN spacecraft

MRC High Resolution. MR-compatible digital HD video camera. User manual

Rodenstock Photo Optics

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

hsfc pro 12 bit ultra speed intensified imaging

scmos discover new ways of seeing andor.com Features and Benefits Scientific CMOS - Fast, sensitive, compact and light. Specifications Summary

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

High Resolution Planetary Imaging Workflow

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

Introduction to CCDs and CCD Data Calibration

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

COOKBOOK. for. Aristarchos Transient Spectrometer (ATS)

Detecting and measuring faint point sources with a CCD

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Characterizing Digital Cameras with the Photon Transfer Curve

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

Infrared Viewers. Manual

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

How To Use An Edge 3.1 Scientific Cmmos Camera

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

Alpy 600 User Guide. Olivier Thizy François Cochard

Light and its effects

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Basler. Area Scan Cameras

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

Large FOV Mobile E-O Telescope for Searching and Tracking Low-orbit Micro-satellites and Space Debris

Basic Optics System OS-8515C

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Alignement of a ring cavity laser

Lenses and Telescopes

INSTITUTE OF THEORETICAL PHYSICS AND ASTRONOMY MOLĖTAI ASTRONOMICAL OBSERVATORY THE 35/51 CM TELESCOPE OF THE MAKSUTOV SYSTEM (ACT-452) USER'S GUIDE

Basics to Using the View Camera

Handheld USB Digital Endoscope/Microscope

Refractors Give the Best Planetary Images

Using Photometric Data to Derive an HR Diagram for a Star Cluster

Computer Vision. Image acquisition. 25 August Copyright by NHL Hogeschool and Van de Loosdrecht Machine Vision BV All rights reserved

Telescope Types by Keith Beadman

Realization of a UV fisheye hyperspectral camera

Understanding Line Scan Camera Applications

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Performance testing for Precision 500D Classical R/F System

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

QHY (5L-II-M) CCD camera for video meteor observation

Automatic and Objective Measurement of Residual Stress and Cord in Glass

ikon-m 934 Series Features and Benefits Industry-Leading Ultra-Sensitive Imaging Technology Specifications Summary andor.com NEW

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

AxioCam HR The Camera that Challenges your Microscope

Solution Derivations for Capa #14

Synthetic Sensing: Proximity / Distance Sensors

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

Optical Modeling of the RIT-Yale Tip-Tilt Speckle Imager Plus

Grasshopper3 U3. Point Grey Research Inc Riverside Way Richmond, BC Canada V6W 1K7 T (604)

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

95508 SKYRIS 132C SKYRIS 132M USB 3.0 ASTRONOMICAL CMOS CAMERA INSTRUCTIONAL MANUAL

PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24

In-Sight Hardware specifications

Alpy calibration User Guide. Olivier Thizy François Cochard

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

arxiv: v1 [astro-ph.im] 24 Mar 2009

Imaging techniques with refractive beam shaping optics

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Physics 441/2: Transmission Electron Microscope

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

Handbook for the SX Lodestar guide camera

Users Manual Model # English

FirstView 3 Reflector Telescope Owner s Manual

GRID AND PRISM SPECTROMETERS

Getting Started emacs.cshrc & :+/usr/local/classes/astr1030/astron/ source.cshrc cd /usr/local/classes/astr1030 idl .compile ccdlab2 ccdlab2 exit

Guide for Installation and Maintenance of MacroAir (ME Series) High Volume Low Speed Fans

SSO Transmission Grating Spectrograph (TGS) User s Guide

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Laserlyte-Flex Alignment System

Basler pilot AREA SCAN CAMERAS

Using Image J to Measure the Brightness of Stars (Written by Do H. Kim)

Physics 116. Nov 4, Session 22 Review: ray optics. R. J. Wilkes

Instruction Manual Genesis 200 EQ

Optical laser beam scanner lens relay system

Day / Night IR Color Camera User Manual V2.1.0

INFRARED PARTS MANUAL

ENGLISH VERSION. ueye LE. Your imagination is our challenge

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Interference. Physics 102 Workshop #3. General Instructions

High Performance Visible Laser Diode Scanners

Planetary Imaging Workshop Larry Owens

The Wide Field Cassegrain: Exploring Solution Space

Application Report: Running µshape TM on a VF-20 Interferometer

Master Anamorphic T1.9/35 mm

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

UV-NIR LASER BEAM PROFILER

How an electronic shutter works in a CMOS camera. First, let s review how shutters work in film cameras.

Transcription:

High-resolution camera for SAM: instrument manual Author:A. Tokovinin Revised by: Version: 2.1 Date: May 29, 2008 File: hrcam/doc/hrcaminst.tex 1 What is HRCam? High-resolution camera (HRCam) is a fast imager designed to work at the SOAR telescope, either with the SOAR Adaptive Module (SAM) or as a stand-alone instrument. HRCam uses the CCD detector with internal electrom multiplication a EMCCD. The HRCam consists of the detector, mechanical structure, filter wheel and optics. The optics forms an enlarged image on the CCD to enable diffraction-limited resolution. Major parameters of HRCam are listed in table 1. Table 1: Summary of HRCam parameters Parameter Value Pixel scale, format, FoV 15 mas, 658x496, 9.9 7.5 Signal resolution, gain 14 bits (16384 ADU), 1.7 el/adu Readout noise 14.3el or 8.4 ADU QE, EM gain Max. 0.5, gain 1 440 Readout speed 30 FPS full-frame Filters U, B, V, R, I, Hα This document contains an essential information on the HRCam hardware. The software for data ascquisition and instrument control is described in a separate manual. Table 2 lists commercial HRcam components. Table 2: Commercial components of HRCam Component Vendor Cost, USD Luca DL658 CCD camera andor.com 9000 Filter wheel CFW10-SA sbig.com 995 UBVRI 1.25 filters sbig.com 875 Hα 1.25 4.5nm sbig.com 275 Two 25-mm lenses edmundoptics.com 133 1

2 Detector The detector model is DL-658M-TIL, serial No. DL-098. It is manufactured by Andor Technology (http://www.andor.com). Major parameters according to the manufacturer s data and our own study are listed in Table 1. The mechanical interface of the detector is a standard C-mount (thread of 1 diameter, 32 TPI). The C-mount has a standard detector depth of 0.7 (17.6 mm), counting from the front flange. This corresponds to using the Luca with its interface ring. The ring must be removed for use with HRCam, in this case the detector depth is reduced by 5.0 mm and corresponds to the CS-mount standard (0.5 depth). The CCD is of line-transfer type, which means that very short (0.5 ms?) exposures are possible without mechanical shutter. It is front-illuminated and has moderate quantum efficiency. The physical pixel size is 10x10 µm, the detector sensitive area is thus 6.6x4.9 mm. The readout speed is 12.5 MHz per pixel, permitting full-frame acquisition rate of 30 fps (126 fps for 128x128 ROI readout). The camera has a USB 2.0 interface. The vendor supplies an image acquisition software for Windows, SOLIS, and a software development kit (SDK) for Windows and Linux. The EM gain can be adjusted from 0 (normal CCD operation without gain) to 255. These gain settings g are related to the actual EM gain g e in a non-linear way. Our study has established the following empirical relation: log 10 g e = 0.310 + 1.92E 3g + 2.37E 5g 2. (1) For example, g = 1, 100, 200, 255 corresponds, respectively, to g e = 2, 5.5, 44, 440 (the formula is no longer valid for g = 255). The dark current is very non-uniform. The detector is normally cooled to 20 C thermoelectrically. At this temperature, some 540 hot pixels can be identified with high dark currents. About 80% of hot pixels have the dark current less than 62 el/s. The dark current averaged over all pixels is about 0.1 el/s, while the manufacturer specifies it as < 1 el/s. The signal normally contains a constant offset (bias) of +500 ADU. This offset is fairly flat and constant. However, when reading in the kinetic mode (fast series of frames), only the first frame has this well-defined bias, while the remaining frames show a characteristic bias structure in the vertical direction (Fig. 1). The cosmetic quality of the detector is quite good. Figure 2 shows the flat field image acquired in the laboratory on October 19, 2007. We see a structure in the vertical direction with a period of exactly 41 pixels. The overall rms fluctuation is only 0.61%, the total range is from 3.0% (black spot) to +1.6%. The quantum efficiency curve provided by the manufacturer is reproduced in Fig. 3. The QE below 400 nm is not specified. However, we did not detect bright stars in the U filter, so the detector is essentialy blind in the UV. 3 Optical design The image at the SOR focal plane is magnified by 2 times to reach the pixel scale of 15 mas (effective focal length 136 m). Such magnification can be easily achieved with one negative lens. However, a 2

Figure 1: Median bias profile in a 100x100 ROI (left) and full frame (right). In both cases gain setting g = 100. Figure 2: Flat field of Luca. The central 200x200 pixel region with gain setting g = 100. 2-lens magnifier with a collimated beam between the lenses is also possible. The advantage of this solution, HRcam8.zmx, is that the insertion or removal of the user filters does not change the focus. The layout is shown in Fig. 4 and the prescription in Table 3. The optical quality is very good, 21 nm rms in the spectral bandwidth from 500 nm to 800 nm. The distance between the lenses can be changed freely. By replacing the last lens, we can get different magnification factors if necessary. 3

Figure 3: Quantum efficiency of Luca as provided by the manufacturer. 50mm/25 +100mm/25 54.3 ~25 100 Figure 4: Optical layout of the design HRcam8.zmx (left) and the spot diagrams for center and 7.5 offsets (right). 4 Mechanical design and installation A fragment of the assembly drawing is shown in Fig. 5. HRCam is normally attached to the SOAR with a big round flange. There are 12 holes on 600 mm diameter for M12 screws. The smaller cylindric base is bolted to the flange with 8 M6 screws on 140 mm diameter. The base contains a negative lens in its holder. The collimated beam after the lens goes through the slide for a user filter and the filter wheel. The slide has a square space of 78.2x78.2 mm width and 10 mm depth. A smaller user filter can be mounted there with a mechanical insert. The slide is fixed with 4 captive screws. The 10-position filter wheel is manufactured by SBIG and contains 1.25 filters in standard SBIG threaded mounts (glass diameter 28 mm). In order to access the filters for changing or cleaning, the HRCam must be disassembled. We had a problem with the wheel rotation when its axis was not 4

Table 3: Optical prescription for HRcam8.zmx Element Distance to the next, mm SAM focus 54.3 EO 45221, 50/25 80 (variable) EO 32327, +100/25 95.92 CCD focal plane No ring! Luca camera Tubus 3.2mm Round flange User filter Filter wheel Cylindric base Round flange Figure 5: Fragment of the HRCam assembly drawing CH2041-1000-00040.pdf. tightened. The round flange with positive lens is bolted to the filter wheel with 4 M4 screws. There are two sets of M4 threaded holes, use those with deeper thread. Be careful to use the screws of adequate length (8 mm), otherwise they will protrude inside the wheel and will stuck or damage the filters. The distance between the detector and the positive lens can be adjusted by rotating the threaded tubus and fixing it with a locking nut. By focusing the collimated beam in the laboratory, we determined that the gap between the nut and the flange must be 3.2 mm. To adjust the detector position angle, 5

we unlock the nut, rotate slightly the tubus with respect to the flange, and lock the nut again. Be sure that the detector is threaded on the tubus without excessive force, but firmly enough to prevent its rotation at the telescope. HRCam installation at SOAR, October 2007 Focus offset ~ 1167 PC RS232 (left) USB (left) OSIRIS 110V #5 110V Figure 6: HRCam installed at the IR straight port of the SOAR, and its connections. A picture of HRcam at SOAR is shown in Fig. 6. Both camera and the filter wheel look in the direction of OSIRIS. This orientation can be changed in the future. Direct attachment to the straight IR port requires refocusing the SOAR M2 by 1 mm, so that the SOAR guider cannot be used. 5 Filter characteristics and photometry The filters installed in HRCam were measured by R. Tighe on Nov. 13, 2007 using the CTIO filtermeasuring setup. The transmission curves are plotted in Fig. 7, their main characteristics are listed in Table 4, with all wavelengths in nm. The bandwidth λ F W HM is determined at the level of halftransmission, the equivalent bandwidth λ EW is calculated as the integral of the transmision curve divided by the maximum transmission. The positions of the filters in the filter wheel are given as well. Originally, the U-filter was installed in the slot 2, but it is useless because the detector cutoff is outside the filter bandpass. The U-filter was replaced in May 2008 with the Strömgren Y-filter (Fig. 8) which was cut form an old 2-inch square filter available at CTIO. The response of the Hα filter is shifted slightly to the red with respect to the Hα line at 656.3 nm. The photometric response of HRCam was determined by observing standard stars in the Graham 6

Figure 7: Transmission curves of HRCam filters UBVRI (left) and Hα (right). The vertical line marks the Hα wavelength. Figure 8: Transmission curve of the Y-filter. E9 region on October 31, 2007. The relation between the recorded flux F (in ADU per second) and the stellar magnitudes m can be expressed as log F = 0.4(m m 0 ), (2) where m 0 is the instrument zero point for a given filter. This is a magnitude of a star that gives flux one ADU/s. The zero points were determined by averaging the two brightest stars. Once the zero points are known, the fluxes can be converted to the instrumental magnitudes by inverting the relation (2). For each filter, we have useful data on 3 stars and calculate one zero point, hence can evaluate the rms difference between the instrumental and catalog magnitude σ which was from 0.01 m to 0.06 m. The zero point for the Hα filter was inferred indirectly by comparing the counts with the R-filter on a bright star. The zero points are given in the last column of Table 4. Considering the small number of stars observed, we did not attempt to study the photometric system of HRCam. 7

Table 4: Filter characteristics and zero points Pos. Band T max,% λ max λλ 0.5 λ F W HM λ EW m 0 2 Y 57.2 550.7 542.7 564.2 21.6 21.8 3 B 67.8 433.6 383.9 483.0 99.1 97.7-4 V 89.2 517.2 492.5 576.7 84.2 84.2 25.27 7 R 80.4 596.1 567.6 688.8 121.2 126.2 25.28 8 I 93.0 774.4 - - - 24.44 9 Hα 79.7 657.3 654.8 659.8 5.04 5.05 21.9: We compare the measured fluxes in the V band with the expected ones to evaluate the detector quantum efficiency (QE). In calculating the expected fluxes, we adopted telescope diameter 4.1 m, central obstruction 0.24, mirror reflectivity 0.89 (3 mirrors), filter bandwidth 84 nm and transmission 0.892. With these data, we expect 6.6E10 photons/s from a star of V = 0. The star with V = 25.28 (zero point) will give flux 5.1 el/s, while the detector measures the flux 1 ADU/s or 1.7 el/s. The ratio corresponds to the quantum efficiency of 0.33. This estimate is affected by the adopted mirror reflectivity, atmospheric transmission, and the energy distribution in stellar spectra. 8