The User s Guide for GRP Panels

Similar documents
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

White rust on galvanized and galvanized pre-painted steel. Technical Information

Columbia flooring will resist fading from exposure to sunlight or artificial light.

Your guide to home maintenance. Flat Roofs

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

REPAIR MANUAL MATERIALS

ABSeam Panel Overview and Installation Instructions

SECTION GUARDA SECURITY WINDOW SCREENS

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

Bathroom Installation Guide

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Composite Stone Veneer


If stepping is required, step at 180mm as seen in this picture.

Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation

Technical handbook Panel Anchoring System

A. Work on this project shall consist of, but is not limited to, the following:

K2 STONE NATURAL VENEER

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

Owner's Manual & Assembly Instructions

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Care and Maintenance for Wood Flooring

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

DIY CABINET REFACING INSTALLATION GUIDE

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

Acrylic Walls Installation Instructions

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Document Library TS Data Sheet

Pilkington Reflite Handling and Processing Guidelines Solar Control

ArcticSkills Task 1: VW Golf front bumper, preparation and painting

Kemlite Transportation Products

Sun Vinyl New Construction Windows Homeowner's Warranty

Installing Window Trim and Door Trim

Tractor Painting Tips

PERFORMANCE GUIDELINES

BLACK JACK ALL WEATHER ROOF COATING

AA Solar and Sun Power Plus

CHAPTER 7: Building Systems ROOFING SYSTEMS

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

COASTLINE QUADRANT ENCLOSURE. Installation / Maintenance Instructions Rev

Operations Manual Blast Chiller

Air Hockey Training Camp Care and repair of your Air Hockey Playfield

GENERAL TRADING TERMS (GTT) RMC by EUROSURFACES

Active and Passive Sash Replacement

Here is your set of Detailed Plans from Copyright 2004 All Rights Reserved

3.8 HSP (High Solids Polyurethane)

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

KITCHEN INSTALLATION GUIDE

GLOBO 30 HANGING design SLIDE Studio

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Aspect Metal Peel & Stick Tile Installation Guide

Basement Window Installation Guide Hopper and Sliding

SAMPLE TEST QUESTIONS MOTOR VEHICLE BODY REPAIRER- ITA WEBSITE

Upper Arm Blood Pressure Monitor SC Instructions for use

Jeep Wrangler Diagnosis & Repair Manual Water Leaks

PROFESSIONAL POPCORN MAKER

ATS Overhead Table Shelf System INSTRUCTION MANUAL

CUBO 20 HANGING design SLIDE Studio

How to Install Hardwood Flooring Over a Sub Floor

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Colonnade Security Pipe

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

VISION SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS

Tips on Applying a Clear Finish

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SEAMS SEAMING USING SEAM TAPE

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Site sampling and testing of concrete

Sun Windows General Information Sun New Construction Window Installation Instructions

Jeep Wrangler Diagnosis & Repair Manual Water Leaks

How to Build a Poker Table

Asphalt Shingle Application Requirements

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster @@@

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

How to secure your property after a disaster

Installation Instructions

Annex 4: FRP CONSTRUCTION STANDARDS*

Site Inspection Report

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

ALI BABA PIANTANA (H165) design SLIDE Studio

OWNER S MANUAL Table Tennis Table Patent Pending

Mold Preventing I nterior System

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

ENIGMA-X SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS

Transcription:

The User s Guide for GRP Panels Imprimerie SENSEY - ARRAS - 03 21 50 29 29-200503_0233 15, Chaussée Brunehaut - B.P. 8 F - 62470 CALONNE-RICOUART Tel : +33 (0) 3 21 65 54 54 Fax : +33 (0) 3 21 65 69 95 E-mail : contacts@carlier-plastiques.com Web : http://www.carlier-plastiques.com

Introduction This leaflet is meant to help the manufacturers of commercial vehicle bodies. They will find here all kinds of advice for the use of GRP panels. In the field of the guarantee on GRP Panels, it is important to follow the instructions written in this document. The Panolit» panels comply with the specifications of the standard NF-T-57-950-1 Summary General aspect of GRP panels 1 Painting GRP panels 2 Colour impregnated Gelcoat 3 Handling and Storing 4 Using GRP Panels 5 Cutting 6 Washing 7 Repairing 8 Field of application 9 Panel return 10 Inside equipment 11 Appendix Repair procedure of GRP panels 12-13 2005041232 We are certified ISO 9001-2000

1. General aspect of GRP panels Due to the characteristics of raw materials and of the manufacturing process, the cosmetic finish of the surface, on the interior and the exterior of the panel, may show the marks of the products used in its manufacture. This will never affect the mechanical properties of the panel. 2. Painting GRP panels Panels can be painted with polyurethane painting systems. It is important to have a previous careful cleaning and degreasing of the surface. Grinding of the gel-coat is not recommended and should be avoided at all costs. A soft rub down with household abrasive pad such as scotchbrite is enough. For a high quality final aspect, please follow the specifications given by the paint manufacturers. Important: In the production of glass reinforced polyester in any form, it is not always possible to guarantee a totally defect free surface. 3. Colour impregnated gelcoat On request, panels can be manufactured with a colour impregnated gelcoat on the exterior face. In this case, great care must be taken when unloading and storing the panels. Panels must also be handled with care during production. We would recommend that panels be ordered with a protective film. (see also : 4. Storing and Handling) It should also be noted that the final aspect of a colour impregnated panel does not reach the level of a painted panel.

4. Handling and Storing We recommend that the panels be unloaded by overhead crane and that during the unloading the panels be supported by either a purpose built steel frame or by load straps positioned at a minimum of every 2500mm throughout the length of the panel. Carlier Plastiques will not accept responsibility for consequences such as cracks, breaks or any damage on the surface of the panels caused by any other method of unloading. For the handling of small panels in sizes of door blanks or bulkheads, it is possible to use a forklift, but in this case the lower and the upper side of the panel should be protected. The panels must be stored flat on wooden struts placed every 1500 mm max., sheltered from bad weather and kept in a dry place. As the process of polymerisation can last several weeks, we recommend to store the panels very carefully. In the case of long storage of panels covered with a protection sheeting, we recommend to remove the sheeting, so as to avoid any colour variation. 5. Using GRP panels All panels are supplied with a sticker INTERIOR SURFACE. Please adhere to this advice. In the case of panels higher than 2440 mm, follow the TOP sticker in order to ensure that the horizontal joint of the panel is always at the top.

6. Cutting It is possible to cut the GRP panels using a circular carbide-tipped saw. To cut out an opening for a refrigeration unit, please use a carbide-tipped jig saw. Always follow the instructions of the cutting system manufacturer, especially for advice on the number of teeth required on the blade and the cutting speed. Insulated panels: In the case of insulated panels, there is a risk of delamination on cutting a panel. This risk can be reduced if the cutting is made on a wooden insert. Should the cutting be however made apart from a wooden insert, caution must be taken to the quality of the blade and the forwarding speed of the cutting facility. After cutting, the edge of the panel must be inspected and a delamination should be repaired immediately with resin or polyurethane glue. 7. Washing On delivery of a vehicle, the end user should be informed about the washing instructions of GRP panels. The wrong ph of the detergent, together with an excessive pressure, or an excessive temperature, at too short a distance to the panel, may destroy its surface. As a general rule, please take the following values in account: Maximum temperature: 70 C (158 F) Maximum pressure: 80 bar (1160 psi) Minimum distance between sprayer and panel: 30 cm (12 ) Soft soaps or basic detergent: ph under 10 Acid solutions: ph over 2.

8. Repairing In the case of an accident on a GRP panel, it is possible to repair. This repair has to be performed very quickly, because of the ingress of moisture which will alter the mechanical characteristics of the panel, and consequently will make the guarantee clause unusable in case of necessity. Please read carefully the repair procedure at the end of this leaflet and do not hesitate to contact the panel manufacturer for useful advice. 9. Field of application General information can be found on our web site: www.carlier-plastiques.com The body builder must ensure that the panel and its dimensions are correct and adequate for the purpose for which it is to be used. Regarding the dimensions of the side walls, please use following rules to determine thickness according to the sizes of the panels: Thickness Dimensions of the body 6 to 11 mm Depending on the specific use 14 mm 3,5 T only 17 mm Maximum length: 13600 mm Maximum height: 2440 mm 20 mm Maximum length: 13600 mm Maximum height: 3150 mm No guarantee will be given outside of the above limits. In the case of insulated vehicles, type and thickness of panels is governed by the use of the vehicle (i.e. refrigerated or chilled) and the type of refrigeration unit required for the operation.

10. Return of panels Should for any reason one or several panels have to be returned to the supplier, they must be treated in the same manor of handling, storing and loading as with normal panels. Any damage caused by loading, storage and transportation whilst in the care of the customer will not be covered by the supplier. It is therefore advised that the customer indicates on the return voucher that the panel has been passed over to the haulier in good condition (except the reason of the claim). Should any damage occur during the return transport, this will then discharge the customer and enable Carlier to ask the haulier for indemnity. 11. Inside equipment In order to meet the end user s requirements, it is possible to fit equipment on the inside of the panel: - metallic or GRP rub strip - horizontal load restraint rails - vertical rails for double deck - meat hanging device on the roof - fridge units and evaporator on the bulkhead or on the roof. (This is an open list) The body builder is responsible for and must ensure that the panels specified are correct and adequate for the purpose for which they are to be used. The fastening by screwing or riveting, with or without bonding, has to be made in accordance with the specifications issued by the fastening manufacturers. Caution : Should the equipment be fitted with screws on a panel with plywood core, check carefully the length of the screw. The end of the screw has to stop before de 2 nd ply from outside... If the fitting of load restraint rails is not made carefully, it may cause waves on the side walls The specifications of use of all equipment have to be respected.

Appendix 12. Repairing procedure for small blemishes (scratches, small gelcoat cracks, small impacts ) Required products: - Thickened and pre-accelerated gelcoat - Polyester film - Catalyst (do not forget to protect your eyes, and wear gloves) - Wax Repairing: 1. Wax and shine the surface to be repaired (the wax helps to stop any surplus gelcoat sticking on the surface around the area of the repair) 2. Rub down the area around the surface of the fault, ensuring that the edges are smooth and the whole area is dust free 3. Prepare the gelcoat: one button of gelcoat and 4 drops of catalyst and mix carefully 4. Apply the mixed gelcoat on the damaged area, and lay polyester film over the area, then level the film and gelcoat out with a flat scraper. 5. After the gelcoat is hardened (times of hardening may differ due to atmospheric conditions), take the polyester film off, clean with a solvent and wipe off the excess of gelcoat.

13. Repairing procedure for major blemishes (cracks until the core material, deep impacts..) 1. Grind down an area of about 70 mm in circumference around the area to be repaired ensuring that the core of the panel is revealed 2. Grind down in a slope about 30 mm around the first area 3. Dry the core if necessary 4. Apply a 300 g/m² woven roving glass against the core, over the 70 mm 5. Impregnate with white resin 6. Apply a 450 g/m² chopped strand mat glass over the whole area of the repair (100 mm) 7. Impregnate with white resin 8. Equalise and roll out the air bubbles 9. After the area of the repair has hardened (times of hardening may differ due to atmospheric conditions), grind down in order to obtain a flat surface 10 Cover and fill the area fill up with polyester mastic and Rub down with a fine sheet of wet and dry in order to obtain a good finish 11. Finish with white gelcoat using the same procedure for small blemishes Edition: June 2006