Model 5190-F Temperature/Humidity Probe

Similar documents
Tipping Bucket Rain Gauge Models 6011-A 6011-B

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

HIH-4000 Series Humidity Sensors

ExStik TM ph Waterproof Meters

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

RGC-IR Remote Gas Calibrator for IR400

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

Dual Laser InfraRed (IR) Thermometer

Temperature Humidity Meter

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

INSTRUCTION MANUAL DTH Fax: (503)

Model SRMD Setra Remote Monitoring Display

This product has the equivalent gain performance with the 14 element Yagi antenna.

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Ceiling Mount Air Handler Manual

C-Tech-10 Operation Manual

About this Manual. Support for Your Product

A-Series Data Loggers PRODUCT MANUAL

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

INTMOD485-LH Protocol Converter

Global Water Instrumentation, Inc.

Part I - Installation

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Subminiature Load Cell Model 8417

Mold Alert... Operation Manual P0270

EzFlex Combustible Gas Leak Detector Model EZ40

±15 V Current-Limited Power Supply

, User s Manual

About Your NetBotz 4-20mA Sensor Pod

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

User Manual (English)

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

InHome Water Leak Detection Package

PS/2 Extender USER MANUAL.

Global Water Instrumentation, Inc.

Current Probes. User Manual

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

PART 1 - INTRODUCTION...

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User Manual. Humidity-Temperature Chart Recorder. Model RH520

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

WET BULB GLOBE TEMPERATURE MEASUREMENT AT THE Y-12 NATIONAL SECURITY COMPLEX

Original instructions Tina 3A/Aps Adaptor unit

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Single Port T1/E1 Tap

Signal Manager Installation and Operation Manual

Global Water Instrumentation, Inc.

1000 Series Data Loggers PRODUCT MANUAL

Humidity Sensor. Model HU-224/225

Global Water Instrumentation, Inc.

Water Leak Detection System

BroadBand PowerShield. User Manual

SDX Submersible Depth Transmitter User Manual

Duct Humidity Transmitter

Sun Vinyl New Construction Windows Homeowner's Warranty

Manual Ranging MultiMeter

i410/i1010 AC/DC Current Clamp

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Architect/Contractor Information Package

Instructions A Amp AC/DC Current Probe

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Ultrasonic Distance Meter. Operation Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

TTL to RS232 Adapter User Guide

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Ground Resistance Clamp-On Tester

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Mini Power Bank and Charger

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Advantium 2 Plus Alarm

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Magnetic Stripe Reader-Writer. Magnetic Stripe Reader-Writer. RS232 & USB-RS232 Interface Quickstart Manual

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

T0118 T2118 T3118. Instruction Manual

Weatherproofing Coaxial Cable Connections

Installation and Operation Guide for PD5100 Automatic Transfer Switch

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

Tina 2A/B Adaptor unit

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Support. Phone Number. Technical. Security. On-Site Repair. Peace of Mind. EPSON PreferredSM. Priority. Toll-Free. and

Owner s Manual

Adjustment functions for both span and shift have been incorporated

Transcription:

Model 5190-F Temperature/Humidity Probe User s Manual Rev. B All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

Copyright 2010, All Weather, Inc. All Rights Reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service All Weather, Inc. manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of All Weather, Inc. Throughout this manual, trademarked names might be used. Rather than put a trademark ( ) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion and to the benefit of the trademark owner, and with no intention of infringement. All Weather, Inc. and the All Weather, Inc. logo are trademarks of All Weather, Inc. Disclaimer The information and specifications described in this manual are subject to change without notice. Latest Manual Version For the latest version of this manual, see the Product Manuals page under Reference on our web site at www.allweatherinc.com/. All Weather, Inc. 1165 National Drive Sacramento, CA 95834 Tel.: (916) 928-1000 Fax: (916) 928-1165 Contact Customer Service Phone support is available from 8:00am - 4:30pm PT, Monday through Friday. Call 916-928-1000 and ask for Service. Online support is available by filling out a request at www.allweatherinc.com/customer/support.html E-mail your support request to support@allweatherinc.com

Table of Contents 1. THEORY OF OPERATION... 1 1.1 Power Supply... 1 1.2 Output Signals... 1 1.3 Environmental Limits... 1 1.3.1 Temperature Limits... 1 1.3.2 Humidity Limits... 1 1.4 Temperature Compensation... 2 1.5 Sensor Protection... 2 2. INSTALLATION & CHECKOUT... 3 2.1 Probe Location... 3 2.2 Wiring Connections... 3 2.3 MARS Installation... 3 3. MAINTENANCE... 4 3.1 Cleaning or Replacing the Dust Filter... 4 3.2 Periodic Calibration Check... 4 3.3 Periodic Maintenance (AWOS Installations)... 4 3.3.1 Equipment Required... 4 3.3.2 Monthly Maintenance... 4 3.3.3 Triannual Maintenance... 4 3.3.4 Annual Maintenance... 5 4. SPECIFICATIONS... 6 5. WARRANTY... 7 6. AWOS WARRANTY... 8

1. THEORY OF OPERATION The Model 5190-F Temperature/Humidity Probe is designed for a variety of environmental monitoring applications, including All Weather Inc.'s Automated Weather Observing Systems (AWOS). The 5190-F operates with a DC supply voltage and has a low current draw. Relative humidity is measured with a thin-film capacitor sensor, and temperature is measured using a Pt100 RTD with an accuracy of ±0.1 C. The signals from the sensors are converted into two linearized voltage output signals. 1.1 Power Supply The 5190-F requires a voltage source in the range of 5 24 V DC, capable of providing 4 ma. In the case of data logger applications, battery power can be conserved by energizing the probe for only 15 seconds during each measurement. 1.2 Output Signals The 5190-F provides two linearized voltage signals as shown below. Parameter Output Voltage Range RH 0 1.0 V DC 0 100% RH Temperature 0 1.0 V DC -40 C to +60 C Note: Do not connect a load to the outputs with an impedance of less than 10 kω. 1.3 Environmental Limits 1.3.1 Temperature Limits The 5190-F was designed to operate from -40 C to +60 C. 1.3.2 Humidity Limits The 5190-F can operate with the RH between 0 and 100%. Direct condensation does not damage the sensors. However, the humidity sensor will not provide correct readings when condensation is present, and neither of the sensors will operate if the sensor leads are short-circuited by condensation. The 5190-F provides a humidity output that is referenced to the saturated water vapor pressure above liquid water. With this reference, the maximum humidity reading at temperatures below freezing are as follows. Maximum RH Temperature Maximum RH Temperature 100% 0 C 81% -20 C 95% -5 C 78% -25 C 91% -10 C 75% -30 C 87% -15 C 1

1.4 Temperature Compensation Practically every make of relative humidity sensor requires a compensation for the effect of temperature on the humidity output signal in order to measure accurately over a wide range of temperature conditions. In the specific case of an instrument using a capacitive sensor, compensation is required because the dielectric characteristics of both the water molecule and the hygroscopic polymer used in the sensor vary with temperature. The electronic circuit of the 5190-F uses data from the Pt100 temperature sensor to automatically compensate the effect of temperature on the accuracy of the humidity measurement. 1.5 Sensor Protection Always use the dust filter provided with the probe to protect the sensors. The standard wire mesh filter is sufficient for most applications. For applications that involve direct spraying of water and/or a lot of dust, use the optional foam filter. 2

2. INSTALLATION & CHECKOUT 2.1 Probe Location Install the probe so that the local conditions at the sensors are typical of the environment to be measured. In an outdoor environment: Use either a shield or a shelter to protect the probe and sensors from direct exposure to solar radiation and precipitation. Several shields are available from All Weather Inc., including the Model 8190 Motor Aspirated Radiation Shield (MARS). In an open field, install the probe at least 5 feet (1.5 m) above ground. Increase this distance if the ground surface is concrete or blacktop (such as above a roof). 2.2 Wiring Connections The 5190-F is supplied with a 5-meter cable (about 16 ft) terminated with tinned ends. Some slack should be left in the cable to allow for a drip loop and to facilitate access to the probe for cleaning and replacement, otherwise any excess length may be trimmed. When a longer cable is required, consider using an extension cable for distances up to 30 m (100 ft). Connect the wires as shown below. Wire Color TB2 Terminal Ground / Gray, Yellow, and Shield 4 Supply Voltage (+) Green 3 RH White 2 Temperature Brown 1 Note: Any other wires colors from the sensor should be covered and insulated so they do not make electrical contact. Check for wiring errors before powering the probe. Improper wiring may damage the probe. Note: Whenever possible, AWI recommends grounding the (-) side of the probe supply voltage. 2.3 MARS Installation If the Model 8190 Motor Aspirated Radiation Shield (MARS) is used with the 5190-F probe, refer to the 8190 MARS User's Manual (8190-001) for installation instructions. Note: In AWOS installations where a 5190-F is installed in a MARS, if the MARS fan fails, temperature and dew point will both be reported as missing. 3

3. MAINTENANCE 3.1 Cleaning or Replacing the Dust Filter The dust filter should be cleaned annually, depending on the conditions of measurement. Whenever possible, cleaning should be done without removing the filter from the probe. Clean the filter with a small brush to remove any debris that may have accumulated on the filter. To replace the filter, unscrew the filter from the probe, replace the filter in the housing, and reinstall the filter assembly. Note: If you remove or replace the filter, make sure that the sensors do not get caught. The humidity sensor is sometimes mistaken for a white paper tag. Do not remove the probe! Before putting on a new dust filter, check the alignment of both sensors with the probe. The wires that connect the sensors to the probe are very thin and bend easily. If this happens, correct the alignment by holding the sensor very gently with a pair of small flat nosed pliers. Do not puncture the sensor with sharp pliers or tweezers or pull too hard on the sensor. 3.2 Periodic Calibration Check Long-term stability of the humidity sensor is typically better than 1% RH per year. For maximum accuracy, the accuracy checks that are part of the triannual maintenance described below must be performed. Applications where the probe is exposed to significant pollution may require more frequent verification. Both the Pt100 RTD temperature sensor and associated electronics are very stable and should not require any calibration after the initial factory adjustment. 3.3 Periodic Maintenance (AWOS Installations) 3.3.1 E quipment R equired The following equipment is required for periodic maintenance of the Model 5190-F. Psychrometer Psychrometric calculator (All Weather Inc. Model 5282-A) All Weather Inc. sells many types of psychrometers, including the Model 5230 Assmann Psychrometer and the Model 5211 Sling Psychrometer. Contact All Weather Inc. for ordering information. 3.3.2 Monthly Maintenance Monthly maintenance of the Model 5190-F consists of checking the 8190 MARS and cleaning it if dust or debris is observed. 3.3.3 Triannual Maintenance Triannual maintenance of the Model 5190-F consists of performing the monthly maintenance tasks, cleaning the dust filter if dust or debris is observed, and checking the accuracy of the 5190-F against readings made using a psychrometer as explained below. 1. Position the psychrometer in close proximity to the intake of the motor aspirated radiation shield. Allow a minimum of 20 minutes for psychrometer conditioning before proceeding. 4

2. Prepare the psychrometer after the waiting period by wetting the wet bulb wick with distilled water. 3. Wind the psychrometer fan motor to provide constant aspiration (Assmann psychrometer only). 4. Begin taking measurements 1.5 minutes after the psychrometer starts running. Record the psychrometer temperature, wet bulb temperature, 5190-F temperature, and 5190-F dew point temperature at 1-minute intervals. 5. Individually average all readings of psychrometer temperature and 5190-F temperature that are within ±1 F (±0.56 C). Subtract the average psychrometer temperature from the 5190-F temperature. For AWOS installations, check the pass status on the data sheet if the result is within ±2 F (±1.1 C). If the sensor fails, replace it and return the failed sensor to All Weather Inc. for calibration. 6. Individually average all readings of wet bulb temperature that are within ±0.5 F (±0.28 C) of each other. Calculate the dew point temperature from the average psychrometer temperature and the average wet bulb temperature using the psychrometric calculator. Subtract the calculated dew point temperature from the AWOS dew point temperature. Check the pass status if the result is within ±3 F (±1.7 C). Replace the sensor if the sensor fails, and return the failed sensor to All Weather Inc. for recalibration. 3.3.4 Annual Maintenance Annual maintenance consists of performing the monthly maintenance tasks and checking the accuracy of the 5190-F against readings made using a psychrometer according to the procedure prescribed for triannual maintenance above. 5

4. SPECIFICATIONS Parameter Humidity Sensor Temperature Sensor Operating Temperature Limits Humidity Output Signal (linear) Temperature Output Signal (linear) Minimum Load per Output Accuracy (at 23ºC) First Signal After Measurement Interval Supply Voltage Current Consumption Cable Length Sensor Protection Dimensions Weight Thin-Film Capacitor Pt100 RTD -40 C to +60ºC 0 1.0 V DC = 0 100% RH Specification 0 1.0 V DC = -40 C to +60 C 10 kω ±1.5% RH ±0.1ºC 2.3 s 0.7 s 5 24 V DC approx. 4 ma 5 m (16 ft), tinned ends Wire mesh filter 208 mm 15 mm diameter (8.19" 0.59") 120 g (0.27 lb) 6

5. WARRANTY Unless specified otherwise, All Weather Inc. (the Company) warrants its products to be free from defects in material and workmanship under normal use and service for one year from date of shipment, subject to the following conditions: (a) The obligation of the Company under this warranty is limited to repairing or replacing items or parts which have been returned to the Company and which upon examination are disclosed, to the Company s satisfaction, to have been defective in material or workmanship at time of manufacture. (b) The claimant shall pay the cost of shipping any part or instrument to the Company. If the Company determines the part to be defective in material or workmanship, the Company shall prepay the cost of shipping the repaired instrument to the claimant. Under no circumstances will the Company reimburse claimant for cost incurred in removing and/or reinstalling replacement parts. (c) This warranty shall not apply to any Company products which have been subjected to misuse, negligence or accident. (d) This warranty and the Company s obligation thereunder is in lieu of all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, consequential damages and all other obligations or liabilities. No other person or organization is authorized to give any other warranty or to assume any additional obligation on the Company s behalf, unless made in writing and signed by an authorized officer of the Company. 7

6. AWOS WARRANTY This equipment has been manufactured and will perform in accordance with requirements of FAA Advisory Circular 150/5220-16C. Any defect in design, materials, or workmanship which may occur during proper and normal use during a period of 1 year from date of installation or a maximum of 2 years from shipment will be corrected by repair or replacement by All Weather Inc. 8

All Weather Inc. 1165 National Drive Sacramento, CA 95818 5190-F-001 Fax: 916.928.1165 Revision B Phone: 916.928.1000 ECO 1888 Toll Free: 800.824.5873 September, 2010