B&R Power Supply PS104

Similar documents
Power Supplies 3. SDN-P DIN Rail Series

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

650W Single Output Power Supply

Single Output Switching Power Supply

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Power Supplies 3. SDN-C Compact DIN Rail Series

APD / Outputs 19" DC/DC Converter, 50 Watt

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

UMEC International Corporation

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Operating Manual UWAPS-TINY Series

Actuator-Sensor-Interface

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

I STAR COMPUTER CO., LTD

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

is then retained absolutely without interruption.

Three-phase monitoring relay CM-PFE

STRATO LED Drivers 70W, Single output

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Redundancy Module QUINT-DIODE/40

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

ST Series POWER SUPPLIES USER INSTRUCTIONS

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

PHOENIX CONTACT - 01/2007

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PWM-60 series IP67 TRC ELECTRONICS, INC

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Antec TruePower User's Manual

Product and functional description

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Digital input modules

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Industrial Power Supplies

Datasheet. Arrant-Light Oy. 120W DR Series

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

DOCUMENTATION PD16 CP3-SVE-M75DC-24

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

MINI MCR-SL-R-UI(-SP)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Relés e Contatores de Estado Sólido SIRIUS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

IO-RM3 3-Stage Relay Module

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Thyristor-controlled power supplies and battery chargers

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Preset Counter signo 721

38 Series - Relay interface modules A

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Thermistor motor protection

7 - Phaseo power supplies and transformers

Telephone- and leased line modem for industrial applications TD-36

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

7.5 Watt AC-DC Switch Power Supply

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

3000W Single Output Power Supply

TEP 200WIR Series, Watt

3000W Single Output Power Supply

User manual Rev. 1.2 (17/04/2015)

PHOENIX CONTACT Features

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Quick Connect. quick - simple - efficient.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM4TG20 three-phase network control relay RM4-T - range V

LED control gear. LED control gear

CompactLogix Power Supplies Specifications

Maximum Input Current Vin=18V, 100% Load A

Transcription:

General Information B&R Power Supply PS104 1. General Information Features of the B&R power supply PS104: Output voltage adjustable to 28 V 115/230 V auto select input Overload design (high put overload capability) Selectable single/parallel operation (jumper) World-wide certifications (UL, EN, CSA, CB Scheme) for industry and office/home Compact construction Mounted and installed quickly and easily (no tools required) 2. Order Data Model Number Short Description Image 0PS104.0 24 VDC power supply, 1 phase, 100 W, input 115/230 VAC, auto select, DIN rail mounting Table 1: PS104 - order data B&R Power Supply PS104 1

Technical Data 3. Technical Data See also data sheet "Technical Data", which is delivered with the power supply. Product ID General Information C-UL-US Listed Input Input Voltage AC 100-120/220-240 V (Auto-Select), 47-63 Hz, suitable for IT power systems (AC 85-132 V / AC 184-264 V, DC 220-375 V) Input Current <2.1 A (@ AC 100 V, 100 W P ) <1 A (@ AC 220 V, 100 W P ) Starting Current I pk /I 2 t External Fusing Transient Immunity Hold-up Time (see "Hold-up Time with ACin", page 6) Output Output Voltage Voltage Regulation Jumper Pos.: Single Use Jumper Pos.: Parallel Use Ripple/Noise Overvoltage Protection (OVP) Output Noise Suppression Rated Continuous Loading PS104 Yes 22A/0.35A 2 s (120Vin) 45A/1.5A 2 s (120Vin) (typ., T U =50 C, cold restart, power mains according to EN 61000-3-3) Not required, unit provides internal fuse (T3 A15H, not accessible) Transient resistance acc. to VDE 0160 / W2 (750 V / 1.3 ms), over entire load range >40 ms @ AC 230 V, 24.5 V / 4.2 A >20 ms @ AC 196 V, 24.5 V / 4.2 A >20 ms @ AC 100 V, 24.5 V / 4.2 A DC 24-28 V (adj. by front panel potentiometer) Preset: 24.5 V ±0.5% @ 4.2 A Dynamic ±1.5% V overall Static 1% V Static 3% V <50 mv PP (20 MHz bandwidth, 50 Ω measurement) <36 V Radiated EMI values below EN50081-1 (Class B), even with long (>2 m), unshielded put cables Up to 4.2 A @ 24.5 V / 3.6 A @ 28 V Depending on built-in orientation, V in and T amb (convection cooling); see "Derating of Output Power", page 6 Overload Behavior Overload Design: No switch-off at overload/short-circuit, instead: up to 1.9 I rated. Oversizing is not necessary to start heavy or demanding loads. Protection Unit is protected against (also permanent) short-circuit, overload and open-circuit. Derating Depending on built-in orientation (see "Derating of Output Power", page 6) Parallel Operation Yes (selectable by front panel jumper) We recommend that you do not operate more than 5 power supplies in parallel. Power Back Immunity 35 V Operation Indicator Green LED (DC OK) Table 2: PS104 - technical data 2 B&R Power Supply PS104

Technical Data Product ID Efficiency, Reliability Efficiency Typ. 90% (@ AC 230 V, 24.5 V / 4.2 A); see "Efficiency", page 5 Loss Typ. 11.4 W (@ AC 230 V, 24.5 V / 4.2 A) MTBF (reliability) Approx. 500,000 h acc. to Siemens standard SN 29500 (24.5 V / 4.2 A, AC 230 V, T amb = +40 C) Prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: Run-in / Burn-in (Full load, T amb = +60 C, on/off cycle) Functional test (100%) Connection Terminals Cage clamp terminals / 2 terminals per put, uniformly firm hold, vibration-resistant and maintenance-free Connector Size Range 0.5-2.5 mm² (20 AWG 12 AWG) Wire tip sleeves can be used Wire Strip Length 6 mm (0.24 in) recommended Additional Features: All terminals are easy to reach as mounted on the front panel. Inputs and puts are strictly separated from each other (inputs below, puts above) and therefore cannot be mixed up. Mounting and connection with requiring a screwdriver! Easy, quick, durable and reliable installation. Operational Conditions Environmental Temperature during Operation Relative Humidity during Operation Storage and Transport Conditions -10 to +70 C (see "Derating of Output Power", page 6) Max. 95%, non-condensing Storage Temperature -25 to +85 C Relative Humidity for Storage Max. 95%, non-condensing Transport Temperature -25 to +85 C Relative Humidity for Transport Max. 95%, non-condensing Mechanical Characteristics Dimensions Width Height Depth Weight Housing Montage 73 mm 75 mm 103 mm (+ DIN rail) 360 g Robust plastic housing, fine ventilation grid on three housing sides to keep small parts, IP20 Easy snap-on mounting onto the DIN rail (TS35/7.5 or TS35/15). Unit sits safely and firmly on the rail; no tools required, even to remove. Mounting Orientation, or (see "Derating of Output Power", page 6) Ventilation/Cooling Normal convection, no fan required: Leave sufficient space for cooling! When the convection is strong enough, the temperature difference T between air intake and put in the housing should not exceed approx. 15K. Recommended space on sides with ventilation holes: 25 mm PS104 Table 2: PS104 - technical data (cont.) Specifications are valid for 230 VAC input voltage, +25 C ambient temperature, and 5 min run-in time, unless otherwise stated. They are subject to change with prior notice. B&R Power Supply PS104 3

Dimensions 4. Dimensions Figure 1: PS104 - dimensions 5. Installation See also the basic installation manual "Installation and Operation". The basic installation manual is delivered with each power supply. 4 B&R Power Supply PS104

Diagrams 6. Diagrams 6.1 Output Characteristics 35 30 Output Voltage V [V] 25 20 15 10 V in = 115/230 VAC Single Use 5 V in = 115/230 VAC Parallel Use 0 0 1 2 3 4 5 6 7 8 Output Current I [A] Figure 2: PS104 - put characteristics V /I (min.) 6.2 Efficiency Efficiency [%] 91 90 89 88 87 86 85 84 115 VAC in 230 VAC in 83 1 1.4 1.8 2.2 2.6 3 3.4 3.8 4.2 Output Current I [A] Figure 3: PS104 - efficiency (@ V = 24.5 V, typ.) B&R Power Supply PS104 5

Diagrams 6.3 Derating of Output Power 120 100 A Output Power [W] 80 a 60 b 40 Mounting 85-132 VACin A-a A-b A-b 20 185-264 VACin A-a A-b A-b 220-375 VDCin A-a A-b A-b 0-10 0 10 20 30 40 50 60 70 Ambient Temperature [ C] 6.4 Hold-up Time with ACin Figure 4: PS104 - derating of put power Hold-up Time [ms] 160 140 120 100 80 60 40 P P P P =100W, typ. =100W, min. =50W, typ. =50W, min. 20 0 80 120 160 200 240 280 Input Voltage VAC [V] in Figure 5: PS104 - hold-up time with ACin (@ V = 24.5 V, typ. + min.) 6 B&R Power Supply PS104

Standards and Certifications 7. Standards and Certifications Electromagnetic Emissions (EME) EN 50081-1 (includes EN 50081-2) Class B (EN 55011, EN 55022) incl. Annex A, thanks to noise suppression EN 61000-3-2 (PFC) Electromagnetic Immunity (EMI) EN 61000-6-2 (includes EN 55024) Safe Low Voltage SELV (EN 60950, VDE0100/T.410), PELV (EN 50178) Protection Class/Degree Class I (EN 60950) / IP20 (EN 60529) The PSU complies with all major safety certifications for EU (EN 60 950, EN 60204-1, EN 50178), the USA (UL 60950, E137006, UL508 LISTED, E198865), Canada (CAN/CSA-C22.2 No. 60950 [CUR], CAN/CSA-C22.2 No. 14 [CUL]), CB Scheme (IEC 60950). CB scheme Table 3: PS104 - standards and certifications B&R Power Supply PS104 7

Standards and Certifications 8 B&R Power Supply PS104