SD326RU68S2 motion control stepper motor drive - SD326 - pulse/direction - <= 6.8 A

Similar documents
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM4TG20 three-phase network control relay RM4-T - range V

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Three-phase monitoring relay CM-PFE

Safety technique. Emergency stop module BO 5988 safemaster

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

DS 600. A contact free flux gate based current measurement sensor 600A rms

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic overload relay EF65, EF96 and EF146

Analog signal converters CC-E I/I Current / current isolators

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power Supplies 3. SDN-P DIN Rail Series

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic overload relay EF19 and EF45

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

STRATO LED Drivers 70W, Single output

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Frequency Converter Fv

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Relés e Contatores de Estado Sólido SIRIUS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

38 Series - Relay interface modules A

APD / Outputs 19" DC/DC Converter, 50 Watt

Operating Manual UWAPS-TINY Series

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thermistor motor protection

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

7.5 Watt AC-DC Switch Power Supply

R.C.C.B. s two-pole LEXIC

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Telephone- and leased line modem for industrial applications TD-36

Waveguide Access Point WGA631. Product Guide

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

DOCUMENTATION PD16 CP3-SVE-M75DC-24

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

SURGE PROTECTIVE DEVICES

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

RY2 miniature industrial relays

User manual Rev. 1.2 (17/04/2015)

38 Series - Relay interface modules A

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

650W Single Output Power Supply

Type: DILM32 10(24V50HZ) Article No.:

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Preset Counter signo 721

MasterINTERFACE 39 Series - Relay interface modules

Actuator-Sensor-Interface

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

CQM1-SF200/CS1W-SF200

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

NX safety stand-alone

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

TEP 200WIR Series, Watt

Type: DILM9 10(24VDC) Article No.:

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

PHOENIX CONTACT Features

MasterINTERFACE 39 Series - Relay interface modules

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Power Meter Series 700

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

CompactLogix Power Supplies Specifications

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Single Output Switching Power Supply

Cross-beam scanning system to detect slim objects. 100 mm in

SINEAX U553 Transducer for AC Voltage

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Transcription:

Characteristics motion control stepper motor drive - SD326 - pulse/direction - <= 6.8 A Main Range of product Product or component type Device short name Supply voltage limits Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period Complementary Format of the drive Network number of phases Jan 02, 2017 Lexium SD3 Motion stepper drive SD326 100...120 V 200...240 V Green Premium product Compliant - since 1014 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product environmental Available End of life manual 18 months Block Single phase [Us] rated supply voltage 200...230 V (- 15...10 %) 100...120 V (- 15...10 %) Supply voltage type AC/DC Network frequency limits 50...60 Hz (- 15...10 %) 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Communication interface Function available Motor phase current Current consumption Nominal power Short-circuit current Associated fuse rating Overvoltage category Inrush current Integrated pulse/direction Holding brake monitoring Rotation monitoring <= 6.8 A <= 0.2 ma (24 V control voltage) 420 W at 230 V 280 W at 115 V 0.5 ka 10 A at 115 V 6 A at 230 V III < 60 A Leakage current < 30 ma conforming to IEC 60990-3 Voltage state 0 guaranteed Voltage state1 guaranteed Input current Input frequency Maximum switching voltage Maximum switching current Voltage drop Physical interface Output voltage Input voltage Residual ripple Type of cooling Maximum mechanical speed Height Width Depth <= 5 V (24 V optocoupler input signals) <= 0.5 V (5 V optocoupler input signals) 2.5...5.25 V (5 V optocoupler input signals) 15...30 V (24 V optocoupler input signals) <= 25 ma (5 V optocoupler input signals) <= 7 ma (24 V optocoupler input signals) <= 200 khz, 5 V optocoupler input signals <= 200 khz, 24 V optocoupler input signals <= 400 khz, ENC_A/ENC_B signal input 30 V DC (readiness signal output) 200 ma (readiness signal output) 50 ma (24 V output signals) RM-FAULT_OUT 1.7 ma (24 V output signals) +BRAKE_OUT 1 V, 50 ma load (24 V output signals) 1 V, 50 ma load (readiness signal output) 1 V, 50 ma load (ENC+5V_OUT signal output) RS422 - ENC_A/ENC_B signal input <= 30 V (24 V output signals) 4.75...5.25 V (ENC+5V_OUT signal output) 24 V -15 %/+20 % (24 V control voltage) <= 5 % (24 V control voltage) Fan 3000 rpm 145 mm 72 mm 140 mm Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27 Product weight 1.2 kg Environment Electromagnetic compatibility Electrostatic discharge level 3 conforming to EN/IEC 61000-4-2 Immunity to radiated radio-electrical interference level 3 conforming to EN/IEC 61000-4-3 Voltage/Current impulse level 3 conforming to EN/IEC 61000-4-5 Immunity to electrical transients level 4 conforming to EN/IEC 61000-4-4 Standards EN/IEC 50178 EN/IEC 61800-3 EN/IEC 61800-3 environment 1 EN/IEC 61800-3 environment 2 EN/IEC 61800-5-1 Product certifications Marking CUL UL Ambient air temperature for operation 0...50 C 0...40 C conforming to UL CE Ambient air temperature for storage -25...70 C Pollution degree Level 2 2

Relative humidity Operating altitude 5...85 % without condensation > 1000...< 2000 m without derating (maximum ambient temperature 40 C, no protective film, lateral distance of > 50mm) <= 1000 m without derating Vibration resistance 1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6 IP degree of protection IP20 IP40 on upper part without removal of protective film Jan 02, 2017 3

Dimensions Drawings Dimensions EMC mounting plate (included) 4

Mounting and Clearance Mounting and Clearance Ambient temperature Mounting distances Mounting recommendations Without protective film (1) With protective film 0... +40 C d > 50 mm/1.97 in. None None d > 50 mm/1.97 in. None d > 10 mm/0.39 in. +40... +50 C d > 50 mm/1.97 in. None Reduce nominal and continuous current by 2.2 % d > 50 mm/1.97 in. Reduce nominal and continuous current Operation not possible (1) Recommendation: remove protective film after installation. Jan 02, 2017 5

Connections and Schema SD326 Connection Example 6