Similar documents
Installation and Operation Manual

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Fire Fighter Phone System Installation Instructions

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Linear Luminaire with LED Series EXLUX 6402/2

Operating Instructions

CB200W Water Leak Detection Panel Application Guide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Wolflite Safety Handlamp H-251E

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Terminal Boxes Series 8146

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

SELECTION, APPLICATION AND MAINTENANCE

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Drayton Digistat +2RF/+3RF

FIREDEX Conventional Fire Panels

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Installation Manual. BYD Wall-mounted AC Charging Box

2M IR Mini Dome Quick Installation Guide

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Operating Instructions

Technical data sheet TDS0070

Triple Waveband Infra-Red Flame Detection

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

FC18 Controller(Interlocking) Product Manual

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

HM-W536 Install Guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Floodlight Range Installation Guide

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

FG MOISTURE MONITOR Installation & Operation Manual

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Explosion proof enclosures

Combi B Alarm box. Mounting instructions

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series


BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

3M Wrist Strap and Footwear Tester 740. User s Guide

GST301. (Single Protection Zone) Operation Manual

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Battery Power Inverters

ALARMLINE ANALOGUE Linear Heat Detection System

Ambient Temperature Sensor TEMPSENSOR-AMBIENT

60 WATT LED TRIPLE BEAM WORKLIGHT

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Modular I/O System Analog and Digital Interface Modules

Capacitive Prox E2K-X

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

HERZ-Thermal Actuators

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Manual. Solar Fountain Mobile Phone Charger

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Manual for Fire Suppression & Methane Detection System

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

RAY-MAX Integrated Solar Power Strip

INSTALLATION INSTRUCTIONS: Viewline 85 mm

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

Model 201 Wiegand Touchpad Reader Installation Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Terminal and Dimension

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

T7560A,B,C Digital Wall Module

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Broadway 3D Security System

MIC-WKT and MIC-WKT-IR

Electronic Pressure Switch EDS 300

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

16/32 Channel 1U Rack Mount CCTV Power Supply

Video Camera Installation Guide

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

WE-350 Series ¼ Turn Electric Actuator

BeoLab 1. User s guide

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

OPL BASIC. Dosing System for Professional Laundry machines. Contents

SHOT BLAST CABINET MODEL NO: CSB20B

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

1000-LB. TRAILER JACK OWNER S MANUAL

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

RayClic Connection System Installation Instructions

Transcription:

DI-9204Exd Digital Flame-proof Manual Call Point CONTENTS 1 General...1 2 Features... 1 3 Technical Specifications...1 4 Construction and Operation Principle... 2 4.1 Exterior View...2 4.2 Operation Principle...2 5 Installation and Wiring... 2 5.1 Wall-mounting...2 5.2 Pole-mounting...4 6 Testing...5 7 Operation...6 8 Applications...6 8.1 Application in Addressable Mode...6 8.2 Non-addressable Mode...6 8.3 Application in Supervised Digital Input (SDI) Loop...7 9 Troubleshooting and Maintenance...7 10 Caution... 7 11 Accessories and Tools...7

DI-9204Exd Digital Flame-proof Manual Call Point 1 General DI-9204Exd Digital Flame-proof Manual Call Point (MCP) is installed in vessels and industrial explosion-proof areas. When there is fire, pressing the glass on this MCP, alarm signal can be sent to fire alarm control panel (FACP). The MCP can work at addressable mode to connect with GST s series FACP that can control fire suppression devices and transmit signal through loop. It can also work at non-addressable mode to connect with 24VDC power and output fire alarm signal through key switch. The MCP is applicable to vessels, Zone 1 and 2 of explosive gas atmosphere and Zone 20, 21, and 22 of explosive dust atmosphere. It is also suitable for outdoor application. 2 Features Using built-in microprocessor for alarm detection and output control. It features stable operation and good protection against electromagnetic interference. Electronically addressed. The address can be modified in field. An independent output contact is provided to control periphery devices. The MCP is reusable. You can press it to alarm, and reset it by a special key. With wide temperature range, high ingress protection rating, the MCP can apply to vessels, outdoors and explosive hazardous environment. 3 Technical Specifications Operating Voltage: Addressable Mode: Loop 24V, ranged 16V~28V Non-addressable Mode: 24VDC, ranged 20VDC~28VDC Operating Current: Standby Current 0.8mA Alarm Current 2.5mA Output Capacity: normally open volt-free output, contact capacity is 1A 24VDC Type of Initiating Part: Reusable. Initiating Mode: Pressing the glass manually. Resuming Mode: Manually resuming the MCP by a special key. Fire Indicator: Red. It flashes normally and lights after alarming. Address Programming Method: Electronic programming ( Address is within 1~242) Operating Environment: Temperature: -40 ~+70 Relative Humidity 95% Dimensions: 211mm 129mm 95mm (without accessories) Ingress Protection Rating: IP65 Material and Color of the Enclosure: ZL102 aluminum alloy, red Weight: 2kg Mounting Hole Distance: 163mm Explosion-proof marking: ExdⅡ BT6/DIP A20 TA,T6; ExdⅡCT6/DIP A20 TA,T6 Page 1 E-MAIL: hombi@hombi.ru

DI-9204Exd Digital Flame-proof Manual Call Point 4 Construction and Operation Principle 4.1 Exterior View The exterior view of the MCP is shown in Fig. 1. Base Cover DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT Unit: mm 4.2 Operation Principle Fig. 1 The MCP alarms fire if pressed. It is self-locked mechanically to reduce possibility of mis-triggered alarm. The built-in microprocessor is designed for checking alarms and controlling its indicators. 5 Installation and Wiring Warning: Before installing the MCP, disconnect power from the loop. Before installation, check whether the enclosure and labels are sound and complete. The MCP can be installed either on the wall or on a pole. 5.1 Wall-mounting The schematic diagram for a wall-mounted MCP is shown in Fig. 2. M5X8 Screw Fig. 2 The steps for installing the MCP on the wall are as follows. Page 2 E-MAIL: hombi@hombi.ru

DI-9204Exd Digital Flame-proof Manual Call Point 5.1.1 Installation of Base and Mounting Plate The MCP consists of a base and an enclosure. Before installation, unfasten the four screws and remove the enclosure from the base with care. Connect the mounting plate and base with M5 8 cross recessed countersunk pan head screws. Then fasten them to the wall with M8 60 expansion bolts. 5.1.2 Cabling For MCPs with explosion mark Ex dii B T6, the cables are to be drawn in through grommets. Thread the screened twisted pair with cross section not less than 1.0mm 2 and outer diameter φ8mm-φ10mm through a metal washer and a grommet, screw them all into the MCP enclosure, and then tighten the grommet with the thread using an Allen key. For MCPs with explosion-proof mark Ex dii C T6, the cables are to be drawn in through flame-proof cable glands following the steps below: (a) Strip an armored cable with cross section not less than 1.0mm 2 diameter φ8mm as shown in Fig. 3. and outer (b) Install the Entrance Interface 3 and Grommet 1 to the MCP body using an Allen key. (c) Thread the end of cable through Nut 8, Grommet 7, Middle Sheath 4, Outer Washer 6, Taper Washer 5, and Flame-proof Washer 9 in sequence, (d) and put the Inner Sheath of the cable inside the Flame-proof Washer 9 of the gland, cover the Armor Layer of the cable outside the Taper Washer 5 of the gland, and then add the Outer Washer 6 of the gland. Fill the uniformly mixed sealing filler between Flame-proof Washer 9 and Taper Washer 5, and then press the two parts tightly. Screw Middle Sheath 4 onto Entrance Interface 3 securely. Refer to Fig. 4. (e) Finally screw and lock Nut 8 onto Middle Sheath 4, as shown in Fig. 4. Fig. 3 Page 3 E-MAIL: hombi@hombi.ru

DI-9204Exd Digital Flame-proof Manual Call Point Gland body 1. Grommet 2.Armored Cable 3. Entrance Interface 4. Middle Sheath 5. Taper Washer 6. Outer Washer 7. Grommet 8. Nut 9. Flame-proof Washer 10.Sealing Filler Fig. 4 5.1.3 Connection There are terminals on the circuit board in the cover, as shown in Fig. 5. Terminal description: Z1 Z2 Z3 Z4 Fig. 5 Z1, Z2: In addressable mode, connecting with signal cable, polarity-insensitive. In non-addressable mode, connecting with 24VDC, polarity-insensitive. Z3, Z4: Junction output for input signal of Z1 and Z2. K1, K2: Volt free normally open output terminals. When the MCP is pressed, output contact is closed to control external devices. These two terminals are optional that can be used or not. Connect the cables to the terminals in sequence. (4) Final installation After connection, put the cover into the base, and then fasten them with M5 10 Hexagon socket countersunk head screws. 5.2 Pole-mounting The pole-mounted MCP is shown in Fig. 6 and dimension of the pole is shown in Fig. 7. The mounting steps is as follows: (1) Thread the cable through the cable outlet of the pole and the rubber washer. (2) Install the pole on the ground using M10 anchor bolts. (3) Screw down the cover, and lay out the cables according to the application requirement with the same method as wall-mounting. (4) Wire the MCP with the same method as wall-mounting. (5) Connect the MCP base with the pole using M4X10 screw assembly. (6) Install the MCP with the same method as wall-mounting. K1 K2 Page 4

DI-9204Exd Digital Flame-proof Manual Call Point M4 10 Screw Assembly M5 10 Hexagon Socket Countersunk Head Screw Rubber Washer Cable Fig. 6 Unit: mm 150 4 8 φ35 Through Hole (C ab le Outlet) 200 58 8- R 6 150 200 Fig. 7 6 Testing Warning: Power up only after all the devices are well connected. (1) Test the MCP after installation or regular maintenance. (2) Before testing, notify the proper authorities that the system is undergoing maintenance and will temporarily be out of service. Disable the zone or system undergoing maintenance to avoid unwanted alarms. (3) Testing in addressable mode: Pressing the glass, the red alarm indicator shall constantly illuminate, and the FACP shall display the MCP address. Page 5

DI-9204Exd Digital Flame-proof Manual Call Point (4) Testing in Non-addressable Mode: Pressing the glass, the red alarm indicator shall constantly illuminate, and the output contacts K1 and K2 shall be shorted. (5) After testing, reset the MCP by the special key. Notify the proper authorities the system is back in operation. If the MCP fails, check if its connection is correct and retest it. If it still fails, please return it for repair. 7 Operation (1) If the MCP works in addressable mode, it needs to be programmed with an address ranging from 1 to 242 using GST handheld programmer. Please refer to the installation and operation manual of the programmer. (2) Please reset the MCP if the fire alarm is cleared. 8 Applications 8.1 Application in Addressable Mode In addressable mode, connect terminal Z1 and Z2 with the loop of the FACP. K1 and K2 can be used as the input signal for other fire protection devices, as shown in Fig. 8. Input Equipment Input Signal Z2 Z1 Fire Alarm Control Panel 8.2 Non-addressable Mode Fig. 8 When the MCP works in non-addressable mode, connect Z1 and Z2 with 24VDC, and K1, K2 as the input signal for other fire protection devices, as shown in Fig. 9. Power Supply 24VDC Input Signal Input Equipment Fig. 9 Page 6 E-MAIL: hombi@hombi.ru

DI-9204Exd Digital Flame-proof Manual Call Point 8.3 Application in Supervised Digital Input (SDI) Loop The MCP can also be used in SDI loop, as in Fig. 10, in which the 2.5k resistor is connected between Z1 and Z2, and the 1k resistor is connected between K2 and Z1. 1 K 1 50 1 K 2.5 K 2 50 Fig. 10 9 Troubleshooting and Maintenance (1) Cannot be programmed If the MCP cannot be programmed, please check the programmer and connecting terminals. Otherwise, the circuit may be broken. (2) Cannot be registered If the MCP cannot be registered, please check whether the wiring of the bus is correct, voltage within normal range and the MCP plugged firmly. Otherwise, the circuit may be broken. 10 Caution (1) Install and maintain the MCP in compliance with installation code applied to explosive hazardous areas. (2) It is prohibited to open the cover with power on in field. (3) The enclosure should be earthed. 11 Accessories and Tools Expansion bolt M8 60 2 Screw M5 8 2 Washer Φ5 2 Spring washer Φ5 2 Mounting plate 1 Reset key 1 1k resistor 1 2.5k resistor 1 M5 Allen Key 1 Page 7

GST China Gulf Security Technology Co., Ltd. No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 066004 Tel: +86 (0) 335 8502528 Fax: +86 (0) 335 8508942 Email: sales@gst.com.cn www.gst.com.cn GST UK Global System Technology PLC Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire, England LE65 1RT Tel: +44 1283 225 478 Fax: +44 1283 220 690 Email: info@gst.uk.com www.gst.uk.com GST Dubai Global System Technology PLC PO Box 17998 Unit ZA04 JEBEL ALI Free Zone, Dubai, UAE Tel: +971 (0) 4 8833050 Fax: +971 (0) 4 8833053 Email: info@gst.uk.com www.gst.uk.com