Arc Fault Protection System

Similar documents
M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Powerware 5110 UPS User s manual

Pure Warranty Statement for Australia

SECTION LOW VOLTAGE LIGHTING CONTROLS

WD-AMX Water Detection Controllers

PAC1 Door Access Controller

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

BroadBand PowerShield. User Manual

CONTROL SWITCHER User s Manual (Preliminary)

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

M3 Single-Slot Cradle. User Guide. Cradle Model: A-1CR-U R00, A-1CR-U00D-040-R00, A-1CR-US R00, A-1CR-U0ED-110-R00

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Current Monitoring Kit QUICK START GUIDE

DAB+ / FM Tuner Model: TU-201

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

User Guide. HDMI Active Cable Extender. DVI-7370c

Current Monitoring Kit

Nintendo 3DS XL Quick-Start Guide

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

TIG INVERTER INSTRUCTION MANUAL

Original instructions Tina 3A/Aps Adaptor unit

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Wireless Home Security Alarm System AM 500

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

User Manual. September 18, Copyright Thomson. All rights reserved.

Generator Differential Relay Electrical Apparatus

Tina 2A/B Adaptor unit

EKOS Cart. Instructions for Use

READ FIRST! Universal Car/Air Adapter User Manual

Dolphin 6500 Mobile Computer. with Windows CE 5.0. Quick Start Guide

RP-6 IR-PRO RP-6. Operation & Installation Guide v1.0

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Solution-16 Operators Manual ISSUE 1.60

Indoor Remote Controlled Power Points

Temperature & Humidity SMS Alert Controller

Installation instructions for Series NRX INCOM communications adapter module

Install the DeviceNet Module using the following procedure:

Application Technique. Safety Function: Magnetic Door Switch Monitoring

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

Operating Manual Remote Cost Control Monitor

How To Use A Power Supply Unit (Upu)

HP UPS R1500 Generation 3

MIC-WKT and MIC-WKT-IR

User's Guide. Integrating Sound Level Datalogger. Model Introduction

MN3310 Evaluation Kit v1 User Guide

AUTODIALLER / QUICKDIALLER - SA132

LCD5500Z / PKP-LCD v3.x Installation Instructions


Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

VR8. User Guide Intruder Alarm System

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

AXIS T81B22 DC 30W Midspan

Operation and Installation Manual

MN1010 Evaluation Kit v3 User Guide

Universal Wireless Effects Controller USER S GUIDE SA115

AP IR Remote Control Installation & Operation Manual

UPGRADE ALARM USER INSTRUCTIONS

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Operating Instructions Electronics module VEGADIF 65

VARIO PROX CARD READER INSTALLATION MANUAL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

L5354 ControlNet Communications Interface

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

How to read this guide

Dolphin 9900 Mobile Computers

5006 Centrex AuxBox. Call Recording for Meridian Digital Centrex Telephones. Hardware & Installation Guide

Inwall 4 Input / 4 Output Module

NortechCommander Software Operating Manual MAN R6

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

USER'S GUIDE NUSCAN 2100 Series

User s Manual AURORA 1.2K/2.2K

Operation Guide VIP-45-WIFI. Video Inspection Probe

Installation guide H A. HSI hardwired system interface

3800 Linear Series. Quick Start Guide

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

PRODUCT LIST Facility DDC Access WebXL DDC

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

IO-RM3 3-Stage Relay Module

Arc Protection Relay REA 101. Operator s Manual

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

IO-DIM6 6-Channel, Digital to Analogue Converters

GST301. (Single Protection Zone) Operation Manual

DVI+HDCP 4x1 Switcher User Manual

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Manual for Fire Suppression & Methane Detection System

Transcription:

Arc Fault Protection System 1S23 relay monitoring systems pty ltd Advanced Protection Devices RMS 1S30 Optical Arc Fault Sensor RMS 1S23 Arc Fault Module 1 or 2 sensor versions External Overcurrent Relay with Current Check as required YN-560 flash light LS-PC635 Sync cable and 6.35mm Mono Line socket Manual mode, 25% of power (binary coding)

Contents 1.0 Introduction 3 2.0 Reference Documents 3 2.1 Expected timing performance 3 3.0 Method 4 3.1 Equipment Under Test 4 3.2 Recommended Test Equipment 4 3.3 Flash Setting 4 3.4 Safety precautions 4 3.5 Timing test of 1S23 ARC Trip Output 5 3.6 Timing test of 1S23 (using current check in overcurrent relay) 7 4.0 Results 8 4.1 Results of 1S23 Output only testing 8 4.2 Results of 1S23 testing including Overcurrent Relay Output (with current checking) 8 The copyright and other intellectual property rights in this document and in any model or article produced from it (and including any Registered or unregistered design rights) are the property of Relay Monitoring Systems Pty Ltd. No part of this document shall be reproduced or modified or stored in another form, in any data retrieval system, without the permission of Relay Monitoring Systems Pty Ltd, nor shall any model or article be reproduced from this document without consent from Relay Monitoring Systems Pty Ltd. While the information and guidance given in this document is believed to be correct, no liability shall be accepted for any loss or damage caused by any error or omission, whether such error or omission is the result of negligence or any other cause. Any and all such liability is disclaimed. Relay Monitoring Systems Pty Ltd 2001-2012 6 Anzed Court Mulgrave 3170 AUSTRALIA Phone 61 3 8544 1200 Fax 61 3 8544 1201 Email rms@rmspl.com.au Web www.rmspl.com.au To download the : http://www.rmspl.com.au/userguide/1s23_arc_timing_user_guide.pdf 7/6/2012 Page 2 of 8

1.0 Introduction This Test Guide describes the method for testing the timing performance of the 1S23 Arc Protection System comprising of Arc Sensors and Arc Fault Module. The simple test setup uses an off the shelf photo flash and standard Doble (or equivalent) test set. For Arc simulation an off the shelf photo flash such as the Yongnuo (YN-560) or similar may be utilised. This flash needs to be equipped with a PC Sync input, for flash initiation, and a Guide Number specification of at least 58 m to ensure reliable sensor operation. Flash initiation and protection timings are undertaken using an AC Test System such as the Doble F2250 (F2251) or similar. An AC channel in the test set is utilised in Arc Fault Applications employing current checking. 2.0 Reference Documents Table 1 Description Document ID Comment RMS Technical Bulletin 1S30 Issue G, 18/07/2011 RMS Technical Bulletin 1S23 Issue G, 6/06/2012 Photo Flash Technical Manual YN-560 Yongnuo PC Sync to 6.35mm Cable LS-PC635 www.hkyongnuo.com 2.1 Expected timing performance The Arc Fault System Module output (1S30 + 1S23) shall have a total operate time of less than 2 ms. The Arc Fault System without an over current check (1S30 + 1S23 + External Overcurrent Relay) shall have a total trip time of less than 15 ms. The Arc Fault System with an external over current check (1S30 + 1S23 + External Overcurrent Relay with current check) shall have a total trip time of less than 30 ms at 5x current setting. 7/6/2012 Page 3 of 8

3.0 Method 3.1 Equipment Under Test RMS 1S30 - Optical Arc Fault Sensor, RMS Arc Fault Monitors 1S23 External Overcurrent Relay (example Reyrolle Argus C 7SR1206) 3.2 Recommended Test Equipment AC Test System Doble F2250 (F2251) or similar Auxiliary Power supply 40-150 VDC, 1A Photo Flash YN-560, Guide number 58 m (@ ISO 100, 105 mm), 4xAA batteries Yongnuo PC Sync to 6.35 mm Cable, LS-PC635 6.35 mm Mono Socket, cable type, terminated with banana plugs on the ends for connection to test set 3.3 Flash Setting To ensure positive operation of the Arc Fault sensors for testing purposes the Photo Flash unit must be set to emit a flash of suitable intensity at a given distance. The angle of incidence of the flash with respect to the sensing point will also influence operation of the Arc Fault sensor, the test flash is to be placed in front of the sensor and aimed directly at the sensor point as shown below: For up to 1m flash distance set the YN-560 Photo Flash at 25% power. For up to 3m flash distance set the YN-560 Photo Flash at 100% power. For other photo flash units experimentation with photo flash setting may be required to achieve positive operation of the Arc Fault sensor. 3.4 Safety precautions To prevent eye injury avoid flash exposure at close proximity. Provide a warning to others to shield their eyes prior to a test sequence. 7/6/2012 Page 4 of 8

3.5 Timing test of 1S23 ARC Trip Output 3.5.1 Example Test setup AC Test System Doble F2250 (F2251) Channel 1 TIME Auxiliary Power Supply Channel 2 AC current Enable Source 2 START Milliseconds Blue 2 1 + - Arc Sensor 3 Input 4 2 A 2 Logic output Enable Initiate External STOP Logic input Auxiliary Power Supply + - 1S23 Arc Fault Module ARC Trip with current check Flash YN-560, Guide number 58m (@ ISO 100, 105mm) Current Input Over Current Relay 6.35mm Mono Line socket Yongnuo PC Sync to 6.35mm Cable LS-PC635 0.5-0.7 m Arc Sensor 1S30 Figure 1: 1S23 test setup (Example shows 1S23 and 1 sensor under test connected to Status input of an Overcurrent relay with the 1S23 ARC Trip output being monitored for timing purposes) 7/6/2012 Page 5 of 8

Doble Test Set YN-560 Flash 6.35mm Mono Line socket Overcurrent Relay Sync cable 1S30 Sensor 1S23 Figure 2: 1S23 setup - general view 3.5.2 Test procedure: 1. Set up the test as shown in the Figure 1. Example shows testing for single sensor operation. 2. On the Doble system set the output of Channel 2 to 0 A/ 50 Hz. 3. Set timer Start to Source 2. 4. Set timer Stop to External and connect for voltage sensing for transition from voltage high to voltage low. Reset the timer. 5. Switch on the Photo Flash unit and wait until the unit is ready to discharge. 6. Enable the output of Channel 2 (green LED shall be lit). To start the test press the Red button Initiate. 7. The Photo Flash will operate and the Doble timer will start counting. Upon closure of the 1S23 output the timer will stop counting. 8. Read the timer result. 9. Repeat the test at least 3 times. Record results in the results table. 10. Repeat tests for all zones and record timing results of respective zone outputs. 7/6/2012 Page 6 of 8

3.6 Timing test of 1S23 (using current check in overcurrent relay) 3.6.1 Example Test setup Figure 3: 1S23 (using current check in overcurrent relay) test setup (Example shows 1S23 and 1 sensor under test connected to Status input of an Overcurrent relay and Arc Trip with Current check output being monitored for timing purposes) 3.6.2 Test procedure: 1. Set up the test as shown in Figure 3. Example shows testing for single sensor operation. 2. Set Input current setting of the external current check relay to the required current sensitivity. 3. On the Doble system set the output of Channel 2 to 5x current setting of the current check relay, for example for a relay set for 0.5A secondary operation set the Doble to output 2.5A/ 50 Hz. 4. Set timer Start to Source 2. 5. Set timer Stop to External and connect for clean contact transition from open to closed. Reset the timer. 6. Switch on the Photo Flash unit and wait until the unit is ready to discharge. 7. Enable the output of Channel 2 (green LED shall be lit). To start the test press the Red button Initiate. 8. The Photo Flash will operate and the Doble timer will start counting. Upon the closing of the overcurrent relay output contacts the timer will stop counting. 9. Read the timer result. 10. Repeat the test at least 3 times. Record results in the results table. 11. Disable Channel 2 of the Doble system after each test to avoid the potential of thermally overloading the current input of the Current Check Relay. 12. Repeat the test for all phases. 7/6/2012 Page 7 of 8

4.0 Results Test results may be recorded in the tables below. 4.1 Results of 1S23 Output only testing Table 2 Description Distance, cm Delay, ms Expected Pass /Fail Test 1 2 ms Test 2 2 ms Test 3 2 ms Overall result 2 ms 4.2 Results of 1S23 testing including Overcurrent Relay Output (with current checking) Table 3 Description Distance, cm Delay, ms Expected Pass /Fail Test 1 30 ms Test 2 30 ms Test 3 30 ms Overall result 30 ms 7/6/2012 Page 8 of 8

Australian Content Unless otherwise stated the product(s) quoted are manufactured by RMS at our production facility in Melbourne Australia. Approximately 60% of our sales volume is derived from equipment manufactured in house with a local content close to 80%. Imported components such as semi-conductors are sourced from local suppliers & preference is given for reasonable stock holding to support our build requirements. Quality Assurance RMS holds NCSI (NATA Certification Services International), registration number 6869 for the certification of a quality assurance system to AS/NZS ISO9001-2008. Quality plans for all products involve 100% inspection and testing carried out before despatch. Further details on specific test plans, quality policy & procedures may be found in section A4 of the RMS product catalogue. Product Packaging Protection relays are supplied in secure individual packing cardboard boxes with moulded styrene inserts suitable for recycling. Each product & packing box is labeled with the product part number, customer name & order details. Design References The products & components produced by RMS are based on many years of field experience since Relays Pty Ltd was formed in 1955. A large population of equipment is in service throughout Australia, New Zealand, South Africa, The Middle East & South East Asia attesting to this fact. Specific product & customer reference sites may be provided on application. Product Warranty All utility grade protection & auxiliary relay products, unless otherwise stated, are warranted for a period of 24 months from shipment for materials & labour on a return to factory basis. Repair of products damaged through poor application or circumstances outside the product ratings will be carried out at the customer s expense. Standard Conditions of Sale Unless otherwise agreed RMS Standard Terms & Conditions (QF 907) shall apply to all sales. These are available on request or from our web site. Relay Monitoring Systems Pty Ltd 6 Anzed Court, Mulgrave, Victoria 3170, AUSTRALIA Tel: +61 3 8544 1200 Fax: +61 3 8544 1201 Email: rms@rmspl.com.au Web: www.rmspl.com.au 2012 Relay Monitoring Systems Pty Ltd Due to RMS continuous product improvement policy this information is subject to change without notice.