Home Inspection Report



Similar documents
Home Inspection Report

Inspection Tech. (330) Inspected By: Aaron Westerburg

Vision Home Inspection

HOME INSPECTION CHECKLIST

Home Inspection Report

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

A.C.E. Home Inspection Service St. Peters, MO (636)

Home Inspection Report

Total Home Inspection Checklist

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

October 5, 2015 Dear Client,

COMPREHENSIVE PROPERTY INSPECTIONS

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT Property Address:

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

Inspecton Report. Property Address:

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

Self-Home Inspection Checklist

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Vari Inspection Services

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)

Inspection Item COMMENTS

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

Orlando Home Inspection Services

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

159 Morningside Avenue, Toronto

19 Ellis Park Road, Toronto

South Carolina Home Inspector Standards of Practice

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL Coast to Coast Property Inspections

Structure Survey Findings:

Peak Home Inspection Services

Crawford Inspection Services C.C.B. #

Georgia Home Inspection Services

Home Inspection Report

Home Management Checklist: Spring

Building Condition Assessment Report

Propery Inspection Report

HOME INSPECTION REPORT

Real Estate Inspection Report

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

GeorgiaHomePros.com Yellow Creek Road Ball Ground, GA Inspected By: Scott Webb

If there are any further questions with regards to the report or inspection, please call.

Home Inspection Report

A and S Property Inspector

Home Inspection Report

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Home Inspection Report

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

SWF Home Inspections

Rehab Inspection Report Page 1

Final Walk-Through Checklist

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN USA Drive. Morris Home Inspection Group, LLC

Estimating Database Checklist

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # , expires 1/2010

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Strickland Home Inspections, LLC th Ct N Plymouth, MN Inspection Report. xxxx St Clair Ave St Paul, MN 55105

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL South East Building Consultants

Property: 123 Main Street Anytown NJ 11111

Table of Contents. Definitions General Information Lots and Grounds Exterior Surface and Components Garage/Carport Electrical

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

Pre-Drywall Inspection Report

Building Condition Assessment Report

VIRGINIA HOME INSPECTIONS P.O.BOX 586 CHINCOTEAGUE ISLAND, VA PHONE

I NI NP R Inspected Items

INSPECTION CONNECTION, INC.

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

1313 Mocking Bird Lane, Raleigh, NC Inspection Date: 01/01/2014. Prepared For:

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick

License Requirements for Persons Engaging in the Business of Inspection Practice:

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Simplify. Homeownership

Property Inspection Report

API America s Property Inspections

Inspection Report. Sample Client. Property Address: XXXX N. Atolia Drive Tucson AZ House and Home

4-Point Inspection Personal Lines (Edition 9/2012)

Open House and Home Tour Checklist

Latigos Trail 911 Latigos Trail ~ Des Peres, Missouri $428,500

Integrating Healthy Housing Considerations into Weatherization Inspections. Jim LaRue

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Guaranteed Home Inspections HOME INSPECTION REPORT By Kurt Shafer Inspector of Properties

Summit Series Single Section and Double Section Homes

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

PDmB, Inc. Definitions

Transcription:

Home Inspection Report?? Tremont Ave, Westfield, NJ 07090 Inspection Date: Tuesday March 31, 2015 Prepared For: Tim Jones Prepared By: Cornerstone Home Inspection 9736504151 Report Number: 33115 Inspector: Michael Dominianni NJ 24GI00036700

?? Tremont Ave, Westfield, NJ 07090 Page 2 Receipt/Invoice Cornerstone Home Inspection Date: Mar 31, 2015 Inspection Number: 33115 Inspected By: Michael Dominianni NJ 24GI00036700 Client: Tim Jones Inspection Home Inspection Fee $795.00 Total $795.00

?? Tremont Ave, Westfield, NJ 07090 Page 3 Report Summary Grounds Service Walks : The town walkway has uneven surfaces. The concrete walkway to the home had cracks and uneven surfaces. Both areas have trip hazards. The rear bluestone walk had loose mortar. Recommend a mason examine and repair all these areas as needed. Driveway / Parking: The driveway has settled near the street and has cracks in various areas. Recommend repair and sealing. Porch: The rear porch is low to the ground and not accessible for inspection. Stoop/Steps: Recommend railing for steps from the sidewalk. Front step landing has loose mortar needing repair. Landscaping: There is wood to soil contact all along the front of the home. This can cause wood rot and promotes insect activity. Recommend a landscaper correct this issue. The tree near the rear corner of the home should be removed. Recommend window well covers. Hose Bib(s ) : Exterior hose bibs were not operated due to cold temperatures. They are not evaluated in this report. Roofing : Roof Cover : The roof covering is older and in satisfactory condition but the rear roof structure had settled to the right side of the rear dormer. Recommend a structural engineer evaluate. Plumbing Vents: Three of the rear plumbing vents on the rear of the home are within 10' of a window. Recommend a plumber and roofer evaluate and correct as needed. Exterior : Chimney(s): Chimney liner inspections are beyond the scope of the home inspection. Recommend a level 2 chimney liner inspection. Call us for an appointment, 973 650 4151. Electrical Service Entry&ElectricOutlets: Recommend GFCI protection for all exterior outlets. Needed on the front lamp post outlet. The exterior rear outlets did not function. Recommend electrician correct. Exterior Doors: Keyed egress door locks should be changed to quick throw dead bolts. Fire safety concern. The front door frame is pushed out at the floor. Garage :

?? Tremont Ave, Westfield, NJ 07090 Page 4 Report Summary Garage Roof: The roof covering is older and in satisfactory condition. The roof structure has rafter spread. Recommend installing secured collar ties. Garage Gutters: Recommend installing gutters and/or downspouts. Garage Siding/Trim : Siding and trim have some damage recommend repair. Garage Floor: Garage floor has large settling cracks recommend repair. Garage and Exterior Electrical: Extension cord wiring, recommend dedicated outlet(s) be added. Recommend confers for junction boxes. Recommend GFCI protection for garage outlets. Kitchen Laundry : Kitchen Appliances & Electric: The electric outlets on the diningr area did not operate. Recommend electrician correct. This may be related to the exterior outlets that did not function. Laundry Room: The washer and dryer are not evaluated in this report. Recommend installing a gfci outlet instead of the use of extension cords for the washer and dryer. Recommend gfci outlet installation. Bath : 1/2 Bath: Water pressure low at sink and faucet difficult to operate. Recommend plumber evaluate. 2nd Floor Bath: The room for will not latch or lock. Recommend repair. The tub original drain stopper does not function. 3rd Floor Bath: Recommend caulking the floor near the shower. The room door will not close. Drags on saddle. Recommend repair. Window frame is slanted due to settlement described on roof section. Basement Bath: window or exhaust fan present. outlet or heat present. Interior Room :

?? Tremont Ave, Westfield, NJ 07090 Page 5 Report Summary Dining room: The floor slopes dramatically towards the front window. The area below has had extensive repairs due to a possible past termite infestation and damage. Further investigation would be needed to determine why this slope is present. Recommend engineer evaluate. Family Room : The outlet to the right of the room door is wired in reverse polarity. Recommend electrician correct. Master Bedroom: Cracks in walks indicate some settlement. 2nd Bedroom: The outlet to the right of the room door is unground. Recommend electrician correct. 3rd Bedroom: The room door will not latch. The floor has damage that may cause injury. Recommend repair. 4th Bedroom: The roof sag described outside the home shows indications inside this room...window is level. Frame is not. For slopes as a result. Fireplace Stairs Halls Attic Fireplace: Damper is missing. recommend repair. Attic/Structure/Framing/Insulation: Insulation is missing on the area off the cost of bedroom 5. Recommend installing insulation. Basement Crawlspace Basement Stairs: The handrail ends should curve into the wall so not too catch clothing or body parts. Foundation: Foundation walls were covered with storage material and were not visible. Cluttered conditions Foundation walls were covered with paneling/drywall and were not visible. Recommend an evaluation when emptied. Basement Floor: There are mouse droppings in many areas of the basement. Recommend extermination company examine evaluate and correct this issue. Basement Drainage: Although there is no current indication of water entry but past entry obvious, it is recommended the exterior grade be sloped away from the home and gutters kept clean. If a sump pump is present, it should be tested periodically making sure it operates. The sump pump pit is undersized. Recommend a larger pit. Recommend consulting with a waterproofing company. Basement Joists/Rim Joists/Sill: Extensive repairs have been performed but it is unable to be evaluated due to clutter and materials. Plumbing

?? Tremont Ave, Westfield, NJ 07090 Page 6 Report Summary Plumbing/Water Service: Old waste lines can be corroded or damaged under the ground between the home and the street. Recommend a plumber run a camera thru the drain to determine its condition. Water Heater #1: The water heater is near its life expectancy. Recommend replacing. The current size of the water heater is inadequate for a 6 bedroom home. Heating and Cooling Cooling System: A/C was not operated due to outside temperature. It appears the condensate line has leaked in the past (OFF CLOSET OF BEDROOM 5). Recommend Technician examine and correct if needed. The stain may contain mold. Recommend testing and remediation depending on results. Electrical Electric Main Panel & House Wiring : There are 2 prong electric present should be changed to 3 prong grounded outlets. There is old knob and tube wiring present near the closet for the main panel that may indicate is presence in other areas. This wiring was not live but world be properly terminated and removed if in other areas. There is open wiring in this same closet that should be terminated. Branch wires under sized on the bottom left 2 breakers. Recommend licensed electrician repair and/or replace as necessary. Open junction box above the dryer needs cover.

?? Tremont Ave, Westfield, NJ 07090 Page 7 Report Overview House in Perspective Scope of Inspection All components designated for inspection in the NJ Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. t all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind.please refer to the pre-inspection contract for a full explanation of the scope of the inspection. Visual Inspection Only Main Entrance Faces rth State of Occupancy Occupied Weather s Sunny 45 Recent Rain Yes Ground Cover Damp Approximate Age

?? Tremont Ave, Westfield, NJ 07090 Page 8 Grounds Service Walks X Concrete X Flagstone/Bluestone X Poor X Trip hazard X Settling cracks X Public sidewalk needs repair Service Walks : The town walkway has uneven surfaces. The concrete walkway to the home had cracks and uneven surfaces. Both areas have trip hazards. The rear bluestone walk had loose mortar. Recommend a mason examine and repair all these areas as needed. Driveway/Parking X Asphalt X Marginal X Settling Cracks Driveway / Parking: The driveway has settled near the street and has cracks in various areas. Recommend repair and sealing.

?? Tremont Ave, Westfield, NJ 07090 Page 9 Grounds Porch Support Pier X Concrete/Brick Floor Porch: The rear porch is low to the ground and not accessible for inspection. Stoops/Steps X Concrete/Bricks X Wood X Railing/Balusters recommended X Marginal X Cracked Stoop/Steps: Recommend railing for steps from the sidewalk. Front step landing has loose mortar needing repair. Patio Deck/Balcony X Wood Finish X Painted/Stained Fence/Wall

?? Tremont Ave, Westfield, NJ 07090 Page 10 Grounds Landscaping affecting foundation Negative Grade X Recommend window wells/covers X Trim back trees/shrubberies X Remove trees too close to home X Wood in contact with/improper clearance to soil Landscaping: There is wood to soil contact all along the front of the home. This can cause wood rot and promotes insect activity. Recommend a landscaper correct this issue. The tree near the rear corner of the home should be removed. Recommend window well covers. Wood to soil contact Retaining wall X Stone Hose bibs Operable X t Tested Hose Bib(s ) : Exterior hose bibs were not operated due to cold temperatures. They are not evaluated in this report.

?? Tremont Ave, Westfield, NJ 07090 Page 11 Roof General Visibility X Partial X Angles Inspected From X Ladder at eaves X With Binoculars Style of Roof Type X Gable Pitch X Low X Medium X Steep Roof #1 Type: Asphalt Layers: 2+ Layers Age: Older Ventilation System Type X Soffit X Roof Flashing X t Visible X t Visible Valleys X t Visible X t Visible of Roof Coverings Roof #1 Roof Cover : The roof covering is older and in satisfactory condition but the rear roof structure had settled to the right side of the rear dormer. Recommend a structural engineer evaluate. Skylights X N/A Plumbing Vents Plumbing Vents: Three of the rear plumbing vents on the rear of the home are within 10' of a window. Recommend a plumber and roofer evaluate and correct as needed.

?? Tremont Ave, Westfield, NJ 07090 Page 12 Roof

?? Tremont Ave, Westfield, NJ 07090 Page 13 Exterior Chimney(s) Viewed From X With Binoculars Rain Cap/Spark Arrestor Chase X Brick Flue X t Visible Evidence of X t evaluated X Have flue(s) cleaned and re-evaluated X t Evaluated Chimney(s): Chimney liner inspections are beyond the scope of the home inspection. Recommend a level 2 chimney liner inspection. Call us for an appointment, 973 650 4151. Gutters/Scuppers/Eavestrough X Galvanized/Aluminum Leaking X Corners X Joints Attachment Siding X Wood Trim/Soffits/Fascias X Wood Caulking Windows X Wood X Vinyl Putty X N/A Storms X N/A Screens X t Installed/t Present Windows : Some windows were missing screens. Question of owner. Exterior Foundation Foundation Wall X Concrete block X Poured concrete X t Visible Concrete Slab X t Visible Electrical Service Entry & Exterior Outlets Location X Overhead Exterior receptacles Operable: Yes X : Marginal Poor GFCI present Electrical Service Entry&ElectricOutlets:

?? Tremont Ave, Westfield, NJ 07090 Page 14 Exterior Electrical Service Entry & Exterior Outlets cont. cont. Recommend GFCI protection for all exterior outlets. Needed on the front lamp post outlet. The exterior rear outlets did not function. Recommend electrician correct. lamp post outlet Building(s) Exterior Wall Construction Type X t Visible X t Visible Exterior Doors Marginal Poor Main Entrance Weatherstripping: Door condition: Marginal Poor Missing Replace Patio Weatherstripping: Marginal Poor Door condition: Marginal Poor Missing Replace Other door Weatherstripping: Marginal Poor Door condition: Marginal Poor Missing Replace Exterior Doors: Keyed egress door locks should be changed to quick throw dead bolts. Fire safety concern. The front door frame is pushed out at the floor.

?? Tremont Ave, Westfield, NJ 07090 Page 15 Exterior Exterior A/C And Or Heat pump Unit #1 Brand: Heil Approximate Age: 12 yrs Energy source X Electric Unit type X Air cooled Outside Disconnect Level Condenser Fins X Need cleaning Insulation Proper Clearance (air flow)

?? Tremont Ave, Westfield, NJ 07090 Page 16 Garage/Carport Garage/Carport X Detached X 2-Car Type Automatic Opener X ne X Operable Operation Safety Reverse Operation X Operable Roofing Type: Asphalt Approx. age: Older Approx. layers: 2 Garage Roof: The roof covering is older and in satisfactory condition. The roof structure has rafter spread. Recommend installing secured collar ties. Gutters/Eavestrough X Missing Garage Gutters: Recommend installing gutters and/or downspouts. Siding/trim X Wood X Marginal X Recommend repair/replace Garage Siding/Trim : Siding and trim have some damage recommend repair.

?? Tremont Ave, Westfield, NJ 07090 Page 17 Garage/Carport Floor X Concrete X Recommend evaluation/repair Source of Ignition within 18" of the floor X N/A Garage Floor: Garage floor has large settling cracks recommend repair. Sill Plates Type X Floor level Overhead Door(s) X Wood Exterior Service Door X ne Electrical Receptacles Reverse polarity X Open ground X

?? Tremont Ave, Westfield, NJ 07090 Page 18 Garage/Carport Electrical Receptacles cont. GFCI Present X Operable: X Handyman/extension cord wiring X Recommend GFCI Receptacles Garage and Exterior Electrical: Extension cord wiring, recommend dedicated outlet(s) be added. Recommend confers for junction boxes. Recommend GFCI protection for garage outlets. Fire Separation Walls & Ceiling X N/A

?? Tremont Ave, Westfield, NJ 07090 Page 19 Kitchen Countertops Cabinets Plumbing Faucet Leaks X Pipes leak/corroded X Sink/Faucet Functional drainage Functional flow Kitchen Plumbing: The sink drain gurgle. May indicate a plumbing vent issue. Recommend a plumber evaluate. Walls & Ceiling Heating/Cooling Source Floor X Marginal Kitchen Floor Covering: The floor tiles are hollow sounding cracked and loose. Recommend tile contractor examine and repair as needed. Appliances & Electrical Disposal(s) Operable: Oven(s) Operable: Range Operable: Dishwasher(s) Operable: Trash Compactor X N/A Exhaust fan Operable:

?? Tremont Ave, Westfield, NJ 07090 Page 20 Kitchen Appliances & Electrical cont. Refrigerator(s)Operable: Microwave X N/A Other X N/A Receptacles present Operable: GFCI Operable: Recommend GFCI Receptacles: Open ground/reverse polarity: X Kitchen Appliances & Electric: The electric outlets on the diningr area did not operate. Recommend electrician correct. This may be related to the exterior outlets that did not function.

?? Tremont Ave, Westfield, NJ 07090 Page 21 Laundry Room Laundry Faucet leaks X Pipes leak X Cross connections X Heat source present X Room combustion air venting Dryer vented X Wall Electrical Open ground/reverse polarity: Yes X GFCI present X X Recommend GFCI Receptacles Appliances X Washer X Dryer Washer hook-up lines/valves Gas shut-off valve Laundry Room: The washer and dryer are not evaluated in this report. Recommend installing a gfci outlet instead of the use of extension cords for the washer and dryer. Recommend gfci outlet installation.

?? Tremont Ave, Westfield, NJ 07090 Page 22 Bathroom (1) Bath Location First floor half bath Sinks Faucet leaks: Toilet Bowl loose: Drainage Water flow Yes X Pipes leak: Yes X Operable: Yes X Moisture stains present X Window Receptacles present Operable: GFCI Operable: Open ground/reverse polarity X Heat source present Exhaust fan Operable: 1/2 Bath: Water pressure low at sink and faucet difficult to operate. Recommend plumber evaluate.

?? Tremont Ave, Westfield, NJ 07090 Page 23 Bathroom (2) Bath Location Second floor bath Sinks Faucet leaks: Yes X Pipes leak: Yes X Tubs Faucet leaks: Yes X Pipes leak: Yes X t Visible Showers Faucet leaks: Yes X Pipes leak: Yes X t Visible Toilet Bowl loose: Yes X Operable: Shower/Tub area X Ceramic/Plastic : Caulk/Grouting needed: Yes X Drainage Water flow Marginal Poor Rooted floors Moisture stains present X Doors X Marginal Window Receptacles present Operable: GFCI Operable: Open ground/reverse polarity X Heat source present Exhaust fan Operable: 2nd Floor Bath: The room for will not latch or lock. Recommend repair. The tub original drain stopper does not function.

?? Tremont Ave, Westfield, NJ 07090 Page 24 Bathroom (3) Bath Location Master bath Sinks Faucet leaks: Yes X Pipes leak: Yes X Showers Faucet leaks: Yes X Pipes leak: Yes X Toilet Bowl loose: Yes X Operable: Shower/Tub area X Ceramic/Plastic : Caulk/Grouting needed: Yes X Drainage Water flow t Visible Marginal Poor Rooted floors Moisture stains present X Doors Window Receptacles present Operable: GFCI Operable: Open ground/reverse polarity X Heat source present Exhaust fan Operable:

?? Tremont Ave, Westfield, NJ 07090 Page 25 Bathroom (4) Bath Location 3rd FL Bath Sinks Faucet leaks: Yes X Pipes leak: Yes X Showers Faucet leaks: Yes X Pipes leak: Yes X Toilet Bowl loose: Yes X Operable: Shower/Tub area X Ceramic/Plastic : Caulk/Grouting needed: Drainage Water flow t Visible Marginal Poor Rooted floors Moisture stains present X Doors X Marginal Window Receptacles present Operable: GFCI Operable: Open ground/reverse polarity X Heat source present Exhaust fan Operable: 3rd Floor Bath: Recommend caulking the floor near the shower. The room door will not close. Drags on saddle. Recommend repair. Window frame is slanted due to settlement described on roof section.

?? Tremont Ave, Westfield, NJ 07090 Page 26 Bathroom (5) Bath Location Basement half bath Sinks Faucet leaks: Toilet Bowl loose: Drainage Water flow Yes X Pipes leak: Yes X Operable: Yes X Moisture stains present Doors Window X ne Receptacles present X Heat source present X Exhaust fan X Basement Bath: window or exhaust fan present. outlet or heat present.

?? Tremont Ave, Westfield, NJ 07090 Page 27 Dining Room Dining Room Walls & Ceiling Moisture stains X Floor X Marginal X Slopes Ceiling fan X ne Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors Windows Dining room: The floor slopes dramatically towards the front window. The area below has had extensive repairs due to a possible past termite infestation and damage. Further investigation would be needed to determine why this slope is present. Recommend engineer evaluate.

?? Tremont Ave, Westfield, NJ 07090 Page 28 Living Room Living Room Walls & Ceiling Moisture stains X Floor Ceiling fan X ne Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors Windows

?? Tremont Ave, Westfield, NJ 07090 Page 29 Family Room Family Room Walls & Ceiling Moisture stains X Floor Ceiling fan X ne Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: X Operable Heating source present Doors Windows Family Room : The outlet to the right of the room door is wired in reverse polarity. Recommend electrician correct.

?? Tremont Ave, Westfield, NJ 07090 Page 30 Master Bedroom Master Bedroom Walls & Ceiling X Typical cracks Moisture stains X Floor Ceiling fan Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors Windows Master Bedroom: Cracks in walks indicate some settlement.

?? Tremont Ave, Westfield, NJ 07090 Page 31 Bedroom 2 Bedroom 2 Walls & Ceiling Moisture stains X Floor Ceiling fan X ne Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: X Operable Heating source present Doors Windows 2nd Bedroom: The outlet to the right of the room door is unground. Recommend electrician correct.

?? Tremont Ave, Westfield, NJ 07090 Page 32 Bedroom 3 Bedroom 3 Walls & Ceiling Moisture stains X Floor X Marginal Ceiling fan X ne Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors X Marginal Windows 3rd Bedroom: The room door will not latch. The floor has damage that may cause injury. Recommend repair.

?? Tremont Ave, Westfield, NJ 07090 Page 33 Bedroom 4 Bedroom 4 Walls & Ceiling Moisture stains X Floor X Marginal X Slopes Ceiling fan X ne Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors Windows 4th Bedroom: The roof sag described outside the home shows indications inside this room...window is level. Frame is not. For slopes as a result.

?? Tremont Ave, Westfield, NJ 07090 Page 34 Bedroom 5 Bedroom 5 Walls & Ceiling Floor Ceiling fan Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors Windows

?? Tremont Ave, Westfield, NJ 07090 Page 35 Bedroom 6 Bedroom 6: Walls & Ceiling Moisture stains X Floor Ceiling fan Electrical Switches: X Operable Receptacles: Open ground/reverse polarity: Yes X X Operable Heating source present Doors Windows

?? Tremont Ave, Westfield, NJ 07090 Page 36 Interior Fireplace Location(s) Living room Type X Gas X Masonry Damper Door Operable: Yes X Damper modified for gas operation X Damper missing Hearth extension adequate Mantel X Secure Physical condition X Marginal X Recommend having flue cleaned and re-examined Fireplace: Damper is missing. recommend repair. Windows Insulated Glass General of Windows Stairs/Steps/Balconies/Halls Handrail Risers/Treads Attic/Structure/Framing/Insulation Access X Stairs Inspected from X In the attic Location X Bedroom Closet Access limited by Finished attic Flooring X Partial Insulation X Fiberglass X Batts X Cellulose Installed in X Walls X Between ceiling joists X Missing Vapor barriers X t Visible Ventilation X Ventilation appears adequate Fans exhausted to X t Visible HVAC Duct Chimney chase X t Visible Roof structure X Rafters X Wood Structural problems observed Ceiling joists X Wood Sheathing X Plywood X Recommend Structural Engineer Evidence of condensation X Evidence of moisture

?? Tremont Ave, Westfield, NJ 07090 Page 37 Interior Attic/Structure/Framing/Insulation cont. Evidence of leaking X Firewall between units X N/A Electrical X apparent defects Attic/Structure/Framing/Insulation: Insulation is missing on the area off the cost of bedroom 5. Recommend installing insulation. Missing insulation

?? Tremont Ave, Westfield, NJ 07090 Page 38 Basement Stairs Handrail Headway over stairs Basement Stairs: The handrail ends should curve into the wall so not too catch clothing or body parts. Foundation X t Elevated X t Visible X Poured concrete Foundation: Foundation walls were covered with storage material and were not visible. Cluttered conditions Foundation walls were covered with paneling/drywall and were not visible. Recommend an evaluation when emptied. Floor X Concrete X Typical cracks Basement Floor: There are mouse droppings in many areas of the basement. Recommend extermination company examine evaluate and correct this issue.

?? Tremont Ave, Westfield, NJ 07090 Page 39 Basement Drainage Sump pump X Working Floor drains X Unknown / t Visible Basement Drainage: Although there is no current indication of water entry but past entry obvious, it is recommended the exterior grade be sloped away from the home and gutters kept clean. If a sump pump is present, it should be tested periodically making sure it operates. The sump pump pit is undersized. Recommend a larger pit. Recommend consulting with a waterproofing company. Girders/Beams Columns X Steel Joists/Rim Joists/Sills X Wood X 2x10 Basement Joists/Rim Joists/Sill: Extensive repairs have been performed but it is unable to be evaluated due to clutter and materials.

?? Tremont Ave, Westfield, NJ 07090 Page 40 Basement Subfloor

?? Tremont Ave, Westfield, NJ 07090 Page 41 Crawl Space Crawl space Type X Combination basement/crawl space/slab ed (heated/cooled) X Access Location X Interior hatch/door Inspected from X Access panel Foundation walls X Concrete block Floor X Concrete X Typical cracks Drainage Sump pump X Standing water X Evidence of moisture damage X Ventilation Location X Wall vents Girders/Beams/Columns X Wood Joists/ Rim Joists / Sills X Wood X t Visible X 2x10 Subfloor X t Visible Insulation Type X Fiberglass Location X Between floor joists Vapor barrier Present X t Visible

?? Tremont Ave, Westfield, NJ 07090 Page 42 Plumbing Plumbing/Water service Main shut-off location In the basement Water entry piping X Copper/Galv. Lead other than solder joints X Unknown Visible water distribution piping X Copper X Galvanized Flow Pipes Supply/Drain Drain/Waste/Vent pipe X Cast iron Supported pipes Traps proper P-Type Drainage Fuel line X N/A Plumbing/Water Service: Old waste lines can be corroded or damaged under the ground between the home and the street. Recommend a plumber run a camera thru the drain to determine its condition. Water heater General Brand Name: A.O. Smith Capacity: 50 gal Approx. age: 9 yrs Type X Gas Combustion air venting present Relief valve Extension proper: Missing Recommend repair Improper material Vent pipe Water Heater #1: The water heater is near its life expectancy. Recommend replacing. The current size of the water heater is inadequate for a 6 bedroom home.

?? Tremont Ave, Westfield, NJ 07090 Page 43 Heating System Heating system Boiler system General Brand name: Burnham Approx. age: 13 yrs Energy source X Gas Distribution X Baseboard X Steam X Radiator Circulator X Gravity Controls Temp/pressure gauge exist: Oil fired units Disconnect: Operable: Combustion air venting present Relief valve Extension proper: Operated When turned on by thermostat: Operation Satisfactory: Yes X X Fired Recommend repair/replace Did not fire old oil line Boiler system (2) General Brand name: Burnham Approx. age: 11 yrs Energy source X Gas Distribution X Hot water X Radiator Circulator X Gravity Controls Temp/pressure gauge exist: Oil fired units Disconnect: Operable: Combustion air venting present Relief valve Extension proper: Operated When turned on by thermostat: Operation Satisfactory: Yes X X Fired Recommend repair/replace Did not fire

?? Tremont Ave, Westfield, NJ 07090 Page 44 Cooling System Cooling System General X Central system Location: Attic Evaporator coil X t Visible Duct work X Metal X Insulated flex duct Refrigerant lines Condensate line/drain X To exterior Secondary condensate line/drain Present: X Recommend HVAC technician examine/clean/service X t operated due to exterior temperature Cooling System: A/C was not operated due to outside temperature. It appears the condensate line has leaked in the past (OFF CLOSET OF BEDROOM 5). Recommend Technician examine and correct if needed. The stain may contain mold. Recommend testing and remediation depending on results.

?? Tremont Ave, Westfield, NJ 07090 Page 45 Electric Main panel & House Wiring Location Basement Adequate Clearance to Panel Amperage/Voltage X 200a X 120v/240v Breakers/Fuses X Breakers Appears grounded GFCI breaker X AFCI breaker X Main wire X Aluminum Branch wire X Copper Branch wire condition X Wires undersized/oversized breaker/fuse Electric Main Panel & House Wiring : There are 2 prong electric present should be changed to 3 prong grounded outlets. There is old knob and tube wiring present near the closet for the main panel that may indicate is presence in other areas. This wiring was not live but world be properly terminated and removed if in other areas. There is open wiring in this same closet that should be terminated. Branch wires under sized on the bottom left 2 breakers. Recommend licensed electrician repair and/or replace as necessary. Open junction box above the dryer needs cover. 2 prong outlets old knob and tube wiring

?? Tremont Ave, Westfield, NJ 07090 Page 46 Electric undersized wires uncovered junction box Sub panel(s) Location(s) Location 1: Basement Branch wire X Copper Neutral/ground separated: Neutral isolated: