Reinforcing Mesh Product Guide Reinforcing New Zealand since 1954 Super Ductile 500E & Hard Drawn
Contents Fletcher Reinforcing New Zealand Standards Equivalent mesh to the 66x sizing Mesh summary Super Ductile 500E Specifications Hard Drawn s Mesh Smart-phone App
Fletcher Reinforcing supplies the reinforcing steel and mesh that provides the strength to New Zealand s buildings and infrastructure. Mesh is available from national Building Merchants or our branch network to construction sites and builders throughout New Zealand. Fletcher Reinforcing offer a range of New Zealand manufactured mesh that complies and is tested to all current Standards. The range covers both Super Ductile mesh in grade 500E wire and a proven range of hard drawn mesh in the sizes required by builders and contractors throughout New Zealand. The Department of Building & Housing now states the reinforcing requirements for concrete slabs-onground of buildings built in accordance with NZS 3604: 2011, have a minimum of 2.27 kg/m2 of Grade 500E reinforcing mesh fabric which conforms with AS/NZS4671:2001. Super Ductile 500E meets these requirements: Grade 500E (seismic) as per AS/NZS 4671:2001 ield stress (MPa) >500 <600 Elongation >10% Tensile Ratio % >1.15 <1.40 Weight per m2 complies with NZS 3604:2011 (min 2.27kg/m2) Weld Shear Strength >5.9 kn External testing is completed by SGS, the world s leading inspection, verification, testing & certification company Hard drawn mesh is specified under NZ3421:1975 (see next page for more detail). Fletcher Reinforcing offers a range of mesh sheet sizes and centres to meet the needs of typical New Zealand applications. Our range covers standard sheet sizes of 4.65m x 1.97m through to our larger economical sheets which are 6.15m x 2.42m. Centres are either 150 x150mm or the step through option of 300 x 300mm.
New Zealand Standards Standards New Zealand controls the preparation and publishing of all Standard Specifications and Codes of Practice in New Zealand. They are developed by expert committees using a consensus-based process that facilitates public input. The relevant Standards listed below, specify the mechanical properties of the steel wire used for concrete reinforcement, the fabrication of the welded fabric and the methods of application in respect to concrete reinforcement. Visit www.standards.co.nz for more information. NZ3421:1975 Specification for Hard Drawn Mild Steel Wire for Concrete Reinforcement The Standard requires the following tensile properties:- NOMINAL DIAMETER (mm) MINIMUM 0.2% PROOF STRESS (MPa) TENSILE STRENGTH (MPa) Minimum Maximum Up to and including 3.15 485 575 855 Over 3.15 485 575 775 NZ3422:1975 Specification for Welded Fabric of Drawn Steel Wire for Concrete Reinforcement This Standard requires a minimum average Weld Shear load Where the longitudinal wire diameter is in the range 11mm to 3.15mm and the longitudinal to transverse wire diameter differential does not exceed 3mm, the minimum average shear value in Newtons shall be not less than 240 multiplied by the cross-sectional area of the longitudinal wire in square millimetres, and states requirements of The distance between centres of two adjacent wires shall not vary by more than 7.5 percent from the exact pitch. If fabric is required to be cut to specific dimensions, the tolerance shall be as follows : 5 Metres and under +25mm over 5 metres +0.5% NZS3101:2006 Code of Practice for The Design of Concrete Structures This Standard lays out the development length and lap-splice requirements for plain wire mesh and deformed wire mesh, and is the basis of any pertinent calculations or recommendations given in this Product Guide.
Hard Drawn Mesh Equivalents Standard Economical Equivalent Centres Wire Ø Length Width Nett Fletcher Nett Fletcher Length Width Cover Reinforcing Cover Reinforcing (mm) (mm) (m 2 ) Item (mm) (mm) (m 2 ) Item 668 150 4.0 4650 1970 7.525 668L 665 150 5.3 4650 1970 7.525 665L 6150 2420 12.760 665E 663 150 6.3 4650 1970 7.525 663L 6150 2420 12.760 663E 662 150 7.1 6150 2400 12.285 662E 661 150 7.5 6150 2400 12.285 661E 300 Centres Nett Fletcher Equivalent Centres Wire Ø Length Width Cover Reinforcing (mm) (mm) (m 2 ) Item 668 300 5.6 4950 2220 10.08 84/10 665 300 7.5 4950 2220 10.08 147/10 Equivalents are based on the nominal sectional area of steel per metre width * Note: Additional meshes are available as a special order. Minimum order quantities will apply. Please contact your local Fletcher Reinforcing Branch for further details Super Ductile 500E Mesh Equivalents Nett Fletcher Equivalent Centres Wire Ø Length Width Cover Reinforcing (mm) (mm) (m 2 ) Item 665 200 6.1 5050 2020 8.312 SE62Res 665 200 6.1 5850 2420 11.93 SE62 665 300 7.5 6050 2420 11.58 SE73 664 200 7.0 6100 2440 12.76 SE72 662 200 8.0 6100 2440 12.76 SE82 661 200 9.0 6100 2440 12.76 SE92 What does SE62 mean? AS/NZS 4671:2001 designates letters to be used to identify welded mesh products: S = Square (shape of grid centres) E = Seismic grade (Earthquake) 6 = 6mm wire 2 = 200mm centres Equivalents are based on the nominal sectional area of steel per metre width
Hard drawn wire mesh Super Ductile wire mesh 485 Mpa Min: 500 MPa Max: 600MPa Wire Cross Mass Industry Wire Cross Mass Description Diameter Centres Section per m 2 Equivalents Description Diameter Centres Section per m 2 mm mm mm 2 /m kg/m 2 mm mm mm 2 /m kg/m 2 668L 4.0 150 83.8 1.315 668 84/10 5.6 300 82.1 1.289 668 665L 5.3 150 147.1 2.309 665 SE62Res 6.1 200 146.1 2.294 665E 5.3 150 147.1 2.309 665 SE62 6.1 200 146.1 2.294 147/10 7.5 300 147.3 2.312 665 SE73 7.5 300 147.3 2.312 663L 6.3 150 207.8 3.263 663 663E 6.3 150 207.8 3.263 663 664 SE72 7.0 200 192.0 3.02 662E 7.1 150 263.9 4.144 662 SE82 8.0 200 251.0 3.95 661E 7.5 150 294.5 4.624 661 SE92 9.0 200 318.0 4.99 Equivalents are based on the nominal sectional area of steel per metre width * Note: Additional meshes are available as a special order. Minimum order quantities will apply. Please contact your local Fletcher Reinforcing Branch for further details
Seismic Grade Reinforcing Mesh SE62 Res Product Description: 5.05m x 2.02m 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire Longitudinal Wire 6.1 R 200 5050 11 25 25 146.1 0.2294 12.74 Cross Wire 6.1 R 200 2020 26 10 10 146.1 0.2294 12.05 GROSS SHEET WEIGHT (Kg): 24.79 2.294 GROSS SHEET AREA (m 2 ): 10.201 NETT COVER (m 2 ): 8.312 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.0933 BUNDLE WEIGHT (Tonnes): 0.6198 ield Strength Tensile Ratio Min Max Min Max Weld Shear Strength 10% 500MPa 600MPa 1.15 1.4 > 5.9 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001. All Super Ductile 500E product is Individually tagged. The tag contains the product code and the unique batch number relevant to the sheet. It is important that this tag is kept in position to allow easy identification until covered with concrete.
Seismic Grade Reinforcing Mesh SE62 Product Description: 5.85m x 2.42m 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire Longitudinal Wire 6.1 R 200 5850 13 25 25 146.1 0.2294 17.45 Cross Wire 6.1 R 200 2420 30 10 10 146.1 0.2294 16.65 GROSS SHEET WEIGHT (Kg): 34.10 2.294 GROSS SHEET AREA (m 2 ): 14.157 NETT COVER (m 2 ): 11.932 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 2.2453 BUNDLE WEIGHT (Tonnes): 0.8525 ield Strength Tensile Ratio Min Max Min Max Weld Shear Strength 10% 500MPa 600MPa 1.15 1.4 > 7.3 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001. All Super Ductile 500E product is Individually tagged. The tag contains the product code and the unique batch number relevant to the sheet. It is important that this tag is kept in position to allow easy identification until covered with concrete.
Seismic Grade Reinforcing Mesh SE73 Product Description: 6.05m x 2.42m 300 x 300 Grid R7.5 Line Wire, R7.5 Cross Wire Longitudinal Wire 7.5 R 300 6050 9 25 25 147.3 0.3468 18.88 Cross Wire 7.5 R 300 2420 21 10 10 147.3 0.3468 17.62 GROSS SHEET WEIGHT (Kg): 36.51 2.312 GROSS SHEET AREA (m 2 ): 14.641 NETT COVER (m 2 ): 11.582 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 2.8550 BUNDLE WEIGHT (Tonnes): 0.9127 ield Strength Tensile Ratio Min Max Min Max Weld Shear Strength 10% 500MPa 600MPa 1.15 1.4 > 11.0 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001. All Super Ductile 500E product is Individually tagged. The tag contains the product code and the unique batch number relevant to the sheet. It is important that this tag is kept in position to allow easy identification until covered with concrete.
Hard Drawn Reinforcing Mesh 668L Product Description: 4.65m x 1.97m 150 x 150 Grid D4.0 Line Wire, D4.0 Cross Wire Longitudinal Wire 4.0 D 150 4650 14 75 75 83.8 0.0986 6.42 Cross Wire 4.0 D 150 1970 31 10 10 83.8 0.0986 6.02 GROSS SHEET WEIGHT (Kg): 12.44 1.315 GROSS SHEET AREA (m 2 ): 9.161 NETT COVER (m 2 ): 7.525 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.0550 BUNDLE WEIGHT (Tonnes): 0.3110 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 665L Product Description: 4.65m x 1.97m 150 x 150 Grid D5.3 Line Wire, D5.3 Cross Wire Longitudinal Wire 5.3 D 150 4650 14 75 75 147.1 0.1732 11.28 Cross Wire 5.3 D 150 1970 31 10 10 147.1 0.1732 10.58 GROSS SHEET WEIGHT (Kg): 21.85 2.309 GROSS SHEET AREA (m 2 ): 9.161 NETT COVER (m 2 ): 7.525 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.0728 BUNDLE WEIGHT (Tonnes): 0.5463 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 663L Product Description: 4.65m x 1.97m 150 x 150 Grid D6.3 Line Wire, D6.3 Cross Wire Longitudinal Wire 6.3 D 150 4650 14 75 75 207.8 0.2447 15.93 Cross Wire 6.3 D 150 1970 31 10 10 207.8 0.2447 14.94 GROSS SHEET WEIGHT (Kg): 30.87 3.263 GROSS SHEET AREA (m 2 ): 9.161 NETT COVER (m 2 ): 7.525 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.0866 BUNDLE WEIGHT (Tonnes): 0.7719 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 665E Product Description: 6.15m x 2.42m 150 x 150 Grid D5.3 Line Wire, D5.3 Cross Wire Longitudinal Wire 5.3 D 150 6150 17 75 75 147.1 0.1732 18.11 Cross Wire 5.3 D 150 2420 41 10 10 147.1 0.1732 17.18 GROSS SHEET WEIGHT (Kg): 35.29 2.309 GROSS SHEET AREA (m 2 ): 14.883 NETT COVER (m 2 ): 12.76 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.1183 BUNDLE WEIGHT (Tonnes): 0.8823 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 663E Product Description: 6.15m x 2.42m 150 x 150 Grid D6.3 Line Wire, D6.3 Cross Wire Longitudinal Wire 6.3 D 150 6150 17 75 75 207.8 0.2447 25.58 Cross Wire 6.3 D 150 2420 41 10 10 207.8 0.2447 24.28 GROSS SHEET WEIGHT (Kg): 49.86 3.263 GROSS SHEET AREA (m 2 ): 14.883 NETT COVER (m 2 ): 12.76 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.1406 BUNDLE WEIGHT (Tonnes): 1.2466 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 662E Product Description: 6.15m x 2.4m 150 x 150 Grid D7.1 Line Wire, D7.1 Cross Wire Longitudinal Wire 7.1 D 150 6150 14 150 150 263.9 0.3108 26.76 Cross Wire 7.1 D 150 2400 40 150 300 263.9 0.3108 29.84 GROSS SHEET WEIGHT (Kg): 56.60 4.144 GROSS SHEET AREA (m 2 ): 14.76 NETT COVER (m 2 ): 12.285 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.2096 BUNDLE WEIGHT (Tonnes): 1.4149 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 661E Product Description: 6.15m x 2.4m 150 x 150 Grid D7.5 Line Wire, D7.5 Cross Wire Longitudinal Wire 7.5 D 150 6150 14 150 150 294.5 0.3468 29.86 Cross Wire 7.5 D 150 2400 40 150 300 294.5 0.3468 33.29 GROSS SHEET WEIGHT (Kg): 63.15 4.624 GROSS SHEET AREA (m 2 ): 14.76 NETT COVER (m 2 ): 12.285 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.2214 BUNDLE WEIGHT (Tonnes): 1.2630 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 84/10 Product Description: 4.95m x 2.22m 300 x 300 Grid D5.6 Line Wire, D5.6 Cross Wire Longitudinal Wire 1 5.6 D 300 4950 6 25 25 82.1 0.1933 5.74 Longitudinal Wire 2 4.0 D 50 4950 4 25 25 0.0986 1.95 Cross Wire 5.6 D 300 2220 19 10 10 82.1 0.1933 8.15 GROSS SHEET WEIGHT (Kg): 15.85 1.289 GROSS SHEET AREA (m 2 ): 10.989 NETT COVER (m 2 ): 10.08 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.0923 BUNDLE WEIGHT (Tonnes): 0.3962 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Hard Drawn Reinforcing Mesh 147/10 Product Description: 4.95m x 2.22m 300 x 300 Grid D7.5 Line Wire, D7.5 Cross Wire Longitudinal Wire 1 7.50 D 300 4950 6 25 25 147.3 0.3468 10.30 Longitudinal Wire 2 5.30 D 50 4950 4 25 25 0.1732 3.43 Cross Wire 7.50 D 300 2220 19 10 10 147.3 0.3468 14.63 GROSS SHEET WEIGHT (Kg): 28.36 2.312 GROSS SHEET AREA (m 2 ): 10.989 NETT COVER (m 2 ): 10.08 Ratio STACK & TURNED (/N): ESTIMATED CUBIC (m 3 ): 0.1236 BUNDLE WEIGHT (Tonnes): 0.7089 Wire Diam 0.2% Proof Stress Min Max Ratio Rm / Re > 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%
Overview The Fletcher Reinforcing Smart Phone App is designed to offer you immediate access to the information you need about our ranges of Super Ductile and Hard Drawn meshes. This Guide will outline how to access this information quickly and easily. Downloading Available for both the Apple iphone and all Android phones, the free download can be accessed through the Apple App Store and the Android Market. Just search for Fletcher Reinforcing Alternatively, scan this QR Code from your phone to be taken to the appropriate download: Current Devices The App is currently available for: iphone Android phones ipad (not optimised)