Similar documents
Cooling Channel Optimization

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Digital Single Axis Controller

The Universal DAQ Device. Connect and measure immediately!

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

USB-500/600 Series Low-Cost Data Loggers and Accessories

connecdim Gateway G1 Ethernet TCP/IP to DALI

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Rackmount Intelligent Pressure Scanners

Current Monitoring Kit QUICK START GUIDE

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Current Monitoring Kit

Remote Level Monitoring Unit

Proportional pressure regulators VPPE

COMBIMASS. Technical Data COMBIMASS eco-bio +

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

NETWORK ENABLED EQUIPMENT MONITOR

CHAPTER 2 INJECTION MOULDING PROCESS

Web site:

Process Alarm Solutions

Thermal Mass Flow Meters and Controllers for Gases

Controlers. Controler

The Business case for monitoring points... PCM architecture...

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

API Marine. BMS Presentation. Ballast Measurement Systems

F453. TiF453. User guide 10/11-01 PC

PRODUCT PROFILE FEATURES

General Injection Mould Specifications KONGSBERG AUTOMOTIVE GROUP

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Aeroqual Connect and Cloud

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Temperature & Humidity SMS Alert Controller

Melting Point Apparatus

Network Video Recorder Quick Operation Guide

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

이 기기는 업무용 급 으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

KACO-monitoring. watchdog prolog insight sunwatch. Easy to install. Inverter integrated monitoring available

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Premium Server Client Software

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

K-Type Thermocouple Sensor User s Guide

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Omega ICD Intelligent Colour Display

Ammonia Detection System Codes and Design Specifications

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

Sales Bulletin #CT016a

OT 40L / 90L. Laboratory Steam Sterilizers

User Guide Reflow Toaster Oven Controller

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

REGTRONIC OPERATING INSTRUCTIONS

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

enetdnc Take Control of your Manufacturing Process and Improve Your Throughput Quickly, Easily and Cost Effectively with...

Intelligent Vibration Monitoring

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

BA Touch. Operating Instructions. Operation and Display Unit for systemp Temperature Controllers and Hot Runner Control Cabinets

Ultimate Server Client Software

Passion for Innovation

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Machine Tool Inspection & Analyzer solutions

Win 7 - STIMA CLS / CMP Driver Installation Quick Guide

COOL Shelf Quick Connect

Autos Limited Ghana Vehicle Tracking Business Proposal

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

USER MANUAL V5.0 ST100

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

The Best Technology for the Application. Educating the Specifier on Medical Air & Medical Vacuum Systems

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

GRUNDFOS DIRECT SENSORS Flow Measurement

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

InfiniTV 4 Installation Instructions

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

EC150 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC150 Setup Guide - Page 1

Data Logging Solutions from Lascar Electronics

InHome Water Leak Detection Package

SMS GSM Alarm Messenger

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

Watchdog Monitor user guide

EN54-16 Voice Alarm System PRODUCT DATASHEETS

Power & Environmental Monitoring

EVAL-UFDC-1/UFDC-1M-16

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Alignment Laser System.

4469 en / c. Ready. Run Start. Stop LCL RMT. Reset USB MODULE. Communications module. User Guide

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Transcription:

Intelligent Mould Flow Monitoring The Mouldflo Flow Monitoring System 1

2 The Mouldflo Flow Monitoring System

Mouldflo Flow Monitoring System For the first time Mouldflo offers Injection Moulders an affordable solution for monitoring flow and temperature circuits within an injection mould. The Mouldflo system will digitally monitor all of the flow circuits within the mould recording data, both flow and temperature, for every circuit. Often overlooked by many moulders, the efficiency of the mould cooling circuit(s) are critical to a stable process and the manufacturer of high quality, dimensionally stable parts. Mouldflo can protect your mould and improve quality by quickly identifying cooling problems and alerting the user to various common cooling circuit problems, such as: No water flow from the mould heater Blocked waterways Scale / rust build up Incorrect piping Injection moulders currently use a range of methods for distributing and controlling the water flow around the cooling circuit. Traditionally the most common method has been with water flow regulators. Although cost effective flow regulators suffer from a number of inherent problems: Bulky / delicate have to be mounted away from the mould Long pipe runs reduced flow Flow restrictions Broken sight glasses Do not give a true reading of flow Sight glasses unreadable due to oxidation High levels of maintenance More recently there has been a trend towards aluminium manifolds mounted either on the mould, or the platens this has seen significant benefits with regards to flow but, generally gives the moulder no visual indication of flow. The Mouldflo Flow Monitoring System 1

Software Interface Touch screen Using a remote mounted touch screen the system will monitor and display the flow and temperature for every circuit. The information can be displayed in either a graphical or text format. The data is stored in the internal memory, time and date stamped for ultimate traceability. The data can also be displayed in a graphical format in order that the operator can spot any trend in deteriorating performance for any particular flow circuit. The data can be read over an ethernet connection, downloaded onto a USB stick or fed into an external production monitoring system or directly into the injection machine control system. Warning and alarm limits can be set for flow and temperature to all monitored zones individually. Should a zone deviate from those settings, then both an onscreen warning and a potential free alarm signal can be fed directly to an ancillary device such as an alarm tower, hot runner controller or the injection moulding machine to warn that the flow has deviated outside of tolerance. The system is capable of storing multiple mould set-ups on the internal memory which can be quickly loaded when a mould is changed with all the correct set-points for any given mould. 2 The Mouldflo Flow Monitoring System

Simple overview The user can see an immediate overview of cooling circuit status at a glance on a single screen with instant display status alarms should the flow / temperature go outside of tolerance. Historical data Historical data recording means that a performance log for each circuit and manifold is stored on the internal memory allowing the user to track the performance and easily identify problems Event log Alarm errors, warnings and operator changes are all stored with a time and date stamp and can be reviewed at any time. Network ready The manifold is equipped with network ready electronics and can be connected to the network/internet via the ethernet connection. This will allow you to monitor the flow from any location directly from your smartphone or laptop. Connect any device It is also possible to feed the data into an external production monitoring system or configure settings by connecting a laptop or directly to the machine controller. The Mouldflo Flow Monitoring System 3

4 The Mouldflo Flow Monitoring System

Validation Until now it has been both difficult and/or very expensive to measure the flow and temperature of the coolant in each circuit of a mould. Although a process may be fully validated and a process window found during the operational qualification, it has been impossible to know if the process is actually running at these settings. A 50 C setting on the mould temperature controller DOES NOT guarantee that all circuits within the mould are actually running at this temperature or give ANY indication of flow. There may be a partial blockage in a water circuit, or a build-up of scale in the water channels, or even an incorrectly piped mould resulting in no flow at all. In all of these instances the mould temperature controller will still show that the coolant is at the correct temperature, both inside your process window and as per your control plan, but, the reality is that the mould is not operating at this temperature. The ability to monitor and record both flow and temperature, and to make flow adjustments as the process demands, gives increased confidence in the process. All of the other main parameters of the moulding machine will give you feedback about the process; it will tell you the effect the injection speed is having on the injection time, or how much injection pressure is actually being used, even the actual temperature on each zone of the barrel. But, even though the mould temperature is one of the most important control characteristics in any process validation, until now it has been impossible to tell what is actually happening inside the cooling circuits. As any good process validator will testify, it is not what the machine is told to do that is important; it is what the machine is actually doing that matters. The Mouldflo Flow Monitoring System 5

Hardware Sensors The Mouldflo Manifold is equipped with very compact sensors that are capable of reading both flow and temperature. The sensor is based upon the vortex flow measurement principle which uses a bluff body in the middle of the flow path to create small eddy currents (vortices) and the pressure of this current is measured to determine the flow through a given cross sectional area. The sensors have no moving parts; this, combined with a large flow path, make it ideally suited to mould cooling even when using heavily contaminated water. The sensors are integrated directly into the manifold keeping size to an absolute minimum; the manifold has been designed to create a fixed linear flow path that is essential for accurate flow measurement. The sensors are available with two flow ranges to suit the application and are held in place with a simple clip which can be easily replaced making maintenance very simple. Interface module The Mouldflo system is equipped with a DIN-Rail mounted interface module (MFIO) this is the hub of the system and allows the manifolds to be easily connected to external devices. The interface module facilitates true plug and play, allowing multiple manifolds to be monitored and also enables convenient and simple connection to the touch screen, power supply, alarm signals in/out and machine communications. The module is equipped with USB and ethernet The data generated by the Mouldflo system can be fed into production monitoring systems or other ancillary devices such as hot runner controllers or the moulding machine control system using the onboard communication ports. 6 The Mouldflo Flow Monitoring System

Manifold The slimline and compact design has been developed to enable the Mouldflo manifold to be mounted into the smallest space possible next to the machine platens, keeping pipe runs to an absolute minimum; improving flow rates to the mould and reducing cycle times. The Mouldflo manifold has 1-1/2 BSP flow and return ports on both the top and bottom of the manifold. This allows maximum flexibility when connecting to the water supply and means that the same manifold can be used on both the fixed and moving half of the moulding machine. The Mouldflo manifold has 1/2 BSP ports for the individual circuits as standard and can be supplied with colour coded ball valves and industry standard connector nipples to the customer specification. The Mouldflo manifold is available with 4, 8 or 12 ports as standard (other sizes are available on request). Multiple manifolds can be electronically daisy-chained together to accommodate the necessary number of flow channels. The system will automatically identify new manifolds and display them on the screen meaning that the system can be expanded in the future. Constructed from custom extruded aluminium, the Mouldflo manifold is black anodised to resist corrosion. The extrusion has been designed to accommodate a linear flow path for each of the flow sensors, which is very important for accurate measurement. The manifold has been extruded with integrated slots on two faces to allow for roll-in t-nuts enabling simple and flexible mounting of the manifolds. The Mouldflo Flow Monitoring System 7

Integrated solutions We are able to offer custom solutions where the electronics is built into the machine control panel and integrated directly into the injection moulding machine. All of the mouldflo screens can be displayed on the machine control panel and the system can be electrically interfaced into the machine control circuits. This provides an additional level of safety and prevents the mould being damaged by not allowing the operator to start moulding until the flow circuits are all within the good operating window. Interface box (DIN) USB Ethernet Machine Communications signal Potential free signal output Touch Screen (optional) 24Vdc (Connect up to 4 manifolds) Manifold PC / Network (optional) Main In/Outlet (1-1/2 BSPP) Mould connections 1 2 BSPP (4-12 zones) Mould 8 The Mouldflo Flow Monitoring System

Technical specifications Manifold Manifold feed Manifold ports Number of ports Regulation Manifold connection 1-1/2 BSP 1/2 BSP 4/8/12 Standard (other sizes on request) Colour coded ball valves per circuit (optional) Customer specified Hasco / DME / Staubli (optional) Operating temperature (max) 0-90ºC Operating pressure (max) 10 bar Temperature sensing Per circuit (return) Flow sensing Per circuit (return) Temperature sensing main inlet Yes (optional) Power supply 12-24 VDC Flow sensor Sensor type Vortex Range (flow) 2-40 litres/min or 1-15 litres/min Accuracy (flow) 1.5% fs Range (temperature) 0-90ºC Resolution (temperature) 0.5ºC Accuracy (temperature) +/- 1,5% fs Sensor signal 0,35 3,5 V Output signal Voltage Response time < 1 s Power supply 5 VDC Seal EPDM Burst pressure 18 bar (40 ºC) Connection Quick connect - plug and play Control Display Control Comunication ports Comunication system Protocols Storage (log and settings) Machine Control integration Remote Access via internet/network Number of zones (flow and temperature) Number of manifolds Display units (flow) Display units (temperature) Warning limits Alarm limits Alarm output Marker input Idle mode input Power supply 15.6 touch screen (optional) Microprocessor based / computer based (optional) Ethernet / USB ASCII(USB) / HTML / SSH (optional) / VNC (optional) USB Serial / TCP/IP Internal (optional) / USB (optional) Yes (optional) Yes (optional) Max 12 Zones / manifold (expandable) Multiple (plug and play) Litres / gallons switchable / RAW (optional) ºC / ºF switchable / RAW (optional) 10% of alarm limits (optional) User definable per zone (optional) Potential free output warning / alarm Potential free Potential free 12-24 VDC No. of ports Total length (A) Ports 4 275mm 1/2 BSPP 8 475mm 1/2 BSPP 12 675mm 1/2 BSPP The Mouldflo Flow Monitoring System 9

Mouldflo is a member of the Mouldpro Group of companies Baltorpbakken 10 DK-2750 Ballerup Denmark Telephone: +45 7020 3131 Fax: +45 7020 3151 www.mouldpro.com 10 The Mouldflo Flow Monitoring System