Table of contents: QR4 Manual 10-08

Similar documents
1000-LB. TRAILER JACK OWNER S MANUAL

Cable Drum Installation

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Installation Instructions

HYDRAULIC LIFT TABLE CART 2200-LB.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

WARNING! DO NOT ATTEMPT TO INSTALL THIS KIT IN A POWERED CONVEYOR.

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

TECHNICAL INFORMATION

Installation Instructions For Slider Casement Air Conditioners

ATS Overhead Table Shelf System INSTRUCTION MANUAL

READ CAREFULLY - FAILURE TO FOLLOW INSTRUCTIONS AND SAFETY RULES MAY RESULT IN SERIOUS INJURY

Roll-Up Door Maintenance Guide

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Series Hose Reels

SELF-STEERING AXLE TABLE OF CONTENTS

HYDRAULIC TABLE CART 500-LB.

Owner s Manual Gantry Cranes

Ceiling Fan Installation Instructions

Guidelines for Earthquake Bracing of Residential Water Heaters

PALLET JACK TON

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

42U/45U 28" Wide Rack Installation & Service Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Multi-Pitch Pitching Machine USER MANUAL

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Drive shaft, servicing

Assembly Instructions for the InteliTrack 3000 Rail Tracking System

Flat Bottom Long Ram Hydraulic Jack

Auto-belay Cable Replacement Process

8" BENCH GRINDER OWNER'S MANUAL

OWNER S MANUAL Table Tennis Table Patent Pending

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Operating Instructions

TS93 EMR T/PT/TDE. Surface applied door closer

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

Step 1. Item 6. Item 1

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

CHECK WITH LOCAL CODE AUTHORITIES ABOUT INSTALLATION REQUIREMENTS FOR THIS PRODUCT INSTALLATION INSTRUCTIONS

Service Manual Supplement

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

INSTALLATION INSTRUCTIONS MULTI-MOUNT KIT Part Number: Application: Warn HP PowerPlant P/N 71800

DO NOT OPERATE LANCELOT OR SQUIRE WITHOUT FIRST ADJUSTING THE SAFETY GUARD. ( See Below)

Operating Instructions

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

Instructions and precautions. Fork Height. Visit our website at:

AMERBRITE UNDERWATER WHITE LED POOL LAMP

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

758 Heavy-duty Ratchet Guy Wire Cutter

Table of Contents WARNING SYMBOLS AND DEFINITIONS

RZ Guardrail System Installation Manual

ReadyLift (Part# ) Strut Extension, Installation Instructions Toyota Tundra New Body Style 2WD & 4WD

Determine the desired location fixture and center the coaxial cord location to the electrical box.

GeekDesk Max Instructions for Assembly & Use

SIMRAD SD10 Sailboat Drive

Installation Instructions

»Product» Safety Warning

These Installation Instructions are valid for antennas in the following version:

Mounting Tripod Kit Installation Manual

! WARNING. Before using product, read and understand instructions.

Strut Spring Compressor

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

QT Residential Blower Metal Residential Blower

INSTRUCTIONS: LocknCharge Laptop Carts

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

12 Volt Electric Winch Owner s Manual. 2953AT Winch

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

IMPORTANT SAFETY RULES TO FOLLOW

WARNING CANADIAN D.O.C. WARNING

I BEAM TRACK INSTALLATION

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

Assembly and Usage Instructions

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Installation Instructions

Guidelines for Earthquake Bracing Residential Water Heaters

GUTTER MACHINE CONTROLS STANDARD

SunMaxx Solar Filling Station Operating Instructions

Operator s Manual EVENTER 20 / 25 Series Lifts

USER INSTRUCTIONS AND SPECIFICATIONS for use of SAFE APPROACH STANDING SEAM ANCHOR & SAFE APPROACH METAL ROOF SCREW-DOWN ANCHOR

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Installation Manual. SKU# series (Base Rails) SKU# series (Overhead Racks)

Operating Instructions

OPERATING INSTRUCTIONS FOR

Electric Hoist 44006

16 April F Dodge Adjustable Track bar with Relocation Bracket 1

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Installation Instructions:

Pulleys and Belt. Install the Major Accessory and Pulley. Install the Motor Pulley NOTE. Align the Motor Pulley and the Tool Pulley NOTE

LUCCI AIRFUSION QUEST II CEILING FAN

3/4 PIPE CLAMP WITH STAND

Transcription:

Table of contents: ITEM # Page Container Contents 2 Necessary Tools 4 General Warnings 5 Installation Instructions 7 Appendix A: Operating Instructions 14 Appendix B: Wiring Diagram 15 Appendix C: Operational Specifications 16 QR4 Manual 10-08

QR4 Manual Page 2 of 15 Welcome to the LynRus QR4 Basketball Goal hoist, the premium hoist available to the gymnasium equipment market! In the box with the hoist, you should also find a packet of installation hardware (Figure1), a key switch (Figure 2), a four prong twist lock receptacle (Figure 3), the QR4 hoist (Figure 4), and the receptacle cover plate (Figure 5). Figure 1: Installation Hardware Figure2: Key Switch Figure 3: Twist Lock Receptacle

QR4 Manual Page 3 of 15 Figure 4: QR4 Hoist Figure 5: Cover Plate

QR4 Manual Page 4 of 15 Here is a list of the contents in the hardware packet: Description Quantity Washer, Flat, ½ x 1-3/8 4 Washer, Lock, ½ 4 Nut, Hex, ½ 4 Screw, Hex head, ½ x 1-3/4 4 Screw, Square head, 3/8 x ½ 2 Clamp, Pipe, 3 2 Following is a list of necessary tools: ¾ inch six or twelve point socket Socket drive handle ¾ inch combination open/box end wrench 3/8 inch eight point socket 0-100 ft*lb torque wrench Center punch & drive hammer (auto-punch will do) 3/8 inch twist drill Cordless drill motor #3 Phillips screwdriver Necessary items that are not supplied with your QR4: 35 of ¼ Galvanized Steel, 7 x 19 stranded Wire Rope (per MIL-DTL- 83420 or Equivalent) (Not available through Lynrus Aluminum Products) 2 ea. ¼ cable clamps Key Switch, UL Listed, Rated for 15A at 120 VAC (usually sold separately) Twist Lock Receptacle, UL Listed, Rated for 15A at 120 VAC (usually sold separately)

QR4 Manual Page 5 of 15 General Warnings WARNING: Read all instructions prior to installation and use. WARNING: This unit is intended for indoor use only. WARNING: This unit is to be installed at least 12 feet or greater above floor. WARNING: Ensure that people are well clear of work area, and that noone is underneath work platform. WARNING: Do not operate hoist when under the influence of alcohol or mind altering substances. WARNING: Always directly observe the movement of the backstop whenever operating, watching for mechanical interference. WARNING: Do not operate hoist when people are underneath backstop or in the path of motion. Failure of cable may lead to injury or death. Use a fall protection device on the backstop. WARNING: Do not operate hoist during electrical storms or sever power line voltage fluctuations. Operating motor at voltages or frequencies other than the nameplate ratings will damage motor and may cause fire or explosion. WARNING: Cable winding on drum poses a severe pinch hazard. Use extreme caution while installing cable. Do not guide cable onto drum with hands; use proper tools. Do not damage or nick the cable in the process of winding it onto the drum. Loose clothing, long hair, jewelry, etc. pose a snag hazard. When installing cable on drum, ensure that the opposite end of the cable is free. Do not attach cable to backstop until the hoist unit is installed and the cable wound on the drum.

QR4 Manual Page 6 of 15 WARNING: When installing unit ensure that work platform is stable and clear of moving equipment during hoist operation. Work platform (i.e. man lifts) may tip when extended to great heights. Make sure the work platform is clear of the backstop when testing the movement of the backstop. Do not stand on work platform during movement of backstop. WARNING: Use appropriate lock-out and tag-out procedure when installing unit. WARNING: Lock out and tag the circuit breaker for this unit before adjusting the limit wheel settings. WARNING: The motor gets very hot during use. Do not touch the hot surface of the motor for 20 minutes after use. Use caution. WARNING: During installation, use a tether on the hoist that will prevent the hoist from falling. WARNING: All installations designs should be approved by a professional structural engineer! WARNING: Hoisting cable must be of sufficient length to permit at least two complete safety wraps on drum at the lower limit of operation! Insufficient cable wraps may allow the cable to pull out of the drum and drop the backstop. WARNING: Limit switch setting operation requires two people; one to operate key switch and one to observe the movement of the hoist and backstop. Ensure that no-one is on man lift or under backstop when moving unit. WARNING: The cable drum may have sharp edges! Wear gloves when handling hoist. WARNING: Cable must move freely through the range of backstop motion. Cable must not wrap over a pulley of diameter smaller than 4-1/2 inches. Cable must not rub against anything as it lifts backstop. Winding too tightly and/or abrasion may cause cable failure.

QR4 Manual Page 7 of 15 Installation Instructions Determine the type of installation that the hoist is going into. Lynrus recommends the installation be to a 3 pipe (outside of a 3 pipe is 3-1/2 inches) using the following steps. WARNING: When installing unit ensure that work platform is stable. Work platform (i.e. man lifts) may tip when extended to great heights. Make sure the work platform is clear of the backstop when testing the movement of the backstop. Do not stand on work platform during movement of backstop. Installation steps: 1. The basketball backstop must be in its deployed (down) position for installation of the hoist. 2. Locate the installation position of the hoist. 2.1. It is important that the hoist be located a proper distance from the closest pulley or attach point. 2.2. This is based on the total travel distance of the cable pulled by the hoist. 2.3. Generally speaking the greater the amount of cable drawn, the greater the distance needs to be. 2.4. For any length of cable, the formula is 4 inches of offset per foot of cable drawn. 2.5. The hoist should be installed so that the center of cable travel on the drum is aligned with the pulley. 2.6. When half of the cable to be used is paid out, the cable should be perpendicular to the drum. 2.7. When installing directly to hoist cable should be perpendicular at closest approach. 2.8. Please refer to Figure 6 and Table1. Cable payout in feet Winch Drum Chart IN. Linear travel on drum Min drum to pulley distance # turns 10 8.6 2.4 48 15 12.9 3.6 60 20 17.1 4.8 72 25 21.4 6.0 86 30 25.7 7.2 103 Figure 6: cable angle Table 1: Offset length

QR4 Manual Page 8 of 15 Determine the installation angle of the hoist (Figure 7). During the full range of motion of the backstop, the cable must: 2.9. Not ever rub the base plate of the hoist. 2.10. Not ever rub the motor of the hoist. 2.11. Wind onto the drum as close as possible to the pinch roller. 2.12. Not ever rub against the backstop or any support structure. 2.13. Attach the cable to the clevis provided on the backstop assembly. 2.14. Terminate the cable using 2 ¼ cable clamps, securely tightened. Figure 7: Installation Angle. WARNING: Cable must move freely through the range of backstop motion. Cable must not wrap over a pulley of diameter smaller than 4-1/2 inches. Cable must not rub against anything as it lifts backstop. Winding too tightly and/or abrasion may cause cable failure. 3. Unpack the hoist and accompanying hardware and ensure that all of the items described above on page 4 are present. WARNING: The cable drum may have sharp edges! Wear gloves when handling hoist.

QR4 Manual Page 9 of 15 4. Attach one half of each pipe clamp to the base plate of the hoist as shown in Figure 8. This is so that you can place the hoist on the mounting structure pipe and have the clamps handy for assembly. 6. Position the hoist and hand tighten the bolts so that the hoist will remain in position on the pipe. 7. Use the 3/8 8 point socket and drive handle to tighten the 3/8 square head set screw against the pipe so as to dent in the paint on the pipe. 8. Loosen the clamp bolts enough that the QR4 Hoist can be rotated and moved about 3 inches to one side. 9. Use center punch to mark and indent the centers of where the set screw upset the paint on the mounting pipe. This is so that you can drill an index hole in the pipe to prevent rotation of the hoist (Figure10). Figure 8: Attaching clamps 5. Insert the second set of bolts and washers into clamps and base plate. (Figure 9) Figure 10: Center punching with an auto-punch. Figure 9: Clamp bolts

QR4 Manual Page 10 of 15 10. Drill the pipe with the 3/8 drill so that the holes pierce completely into the interior of the pipe (Figure11). cable into socket in drum, Torque set screws to 7 ft*lbs (Figure13). Figure 11: Drilling index holes to prevent hoist rotation on pipe 11. Re-position the hoist clamps over the holes in the pipe and tighten the square head set screws into the holes in the pipe. Torque the set screws to 18 ft*lbs. 12. Tighten the four half inch hex bolts that hold the clamps to the base plate. Torque the nuts on the hex bolts to 35 ft*lbs (Figure 12). Figure 13: Install cable in drum 17. Wind a minimum two safety wraps of cable on the drum (Figure14). 18. The cable must wind onto the drum following the grooves in the drum. It will only wind on the drum properly in one direction (Figures 7, 13, and 14). Figure 12: Tighten clamp bolts with torque wrench 13. Ensure wiring is installed and power is active. Receptacle must be prewired and active to install cable. 14. Ensure cable is strung and ready to go. 15. Plug twist lock plug into receptacle. Receptacle must be wired and active. 16. Use only ¼ Galvanized Steel, 7 x 19 stranded Wire Rope (per MIL- DTL-83420 or Equivalent) Insert Figure 14: Two safety wraps on drum. WARNING: Cable winding on drum poses a severe pinch hazard! Use extreme caution while installing cable. Do not guide cable onto drum with hands; use proper tools. Do not damage or nick the cable in the process of winding it onto the drum. Do not wear loose clothing, long hair, jewelry, etc. When installing cable on drum, ensure that the opposite end of the cable is free. Do not attach cable to backstop until the hoist unit is installed and the cable wound on the drum.

QR4 Manual Page 11 of 15 19. Attach far end of cable to the backstop. Leave 1-2 inches of slack in cable. 20. Lock out electrical power. You have completed the basic mechanical installation of the QR4 hoist, now it is time to set the limit switches. WARNING: The QR4 unit is very powerful! Once the cable is attached to the hoist and the backstop, the circuit breaker for the hoist must be locked out any time the work platform is in the path of the backstop travel. WARNING: Hoisting cable must ALWAYS be of sufficient length to permit at least two complete safety wraps on drum at the lower limit of operation! Insufficient cable wraps may allow the cable to pull out of the drum and drop the backstop. WARNING: Limit switch setting operation requires two people; one to operate key switch and one to observe the movement of the hoist and backstop. Ensure that no-one is on work platform or under backstop when moving unit! Figure 15: Limit box retaining screw. WARNING: HIGH VOLTAGE! Setting the limit switches is a hazardous operation. To set the limit switches you must access the hoist while the cable is installed. Lock out and tag the circuit breaker for this unit before adjusting the limit wheel settings. This prevents electric shock, and injury due to unexpected hoist movement. 22. Press the index bar back away from the down direction index wheel rotate the wheel until the switch clicks indicating that the switch is active (Figure 16). WARNING: The motor gets very hot during use! Do not touch the hot surface of the motor for 20 minutes after use. Always use caution when touching unit. 21. Loosen the retaining screw and remove the Limit Box Cover (Figure 15). Figure 16: Limit switch adjustment

QR4 Manual Page 12 of 15 23. Unlock and restore Electrical power. Twist the key switch in the down direction to verify the down switch setting. The hoist should not move. 24. Lock out Electrical power and adjust the down direction wheel as necessary to obtain desired setting. The cable should have 1-2 inches of slack in the down position. 25. Estimate the amount of cable drawn when the backstop travels from the deployed (down) position to the stowed (up). The number of feet of cable is roughly equivalent to the number of threads between the two index wheels. 26. Set the Up Direction index wheel so that the two wheels are the same number threads apart as the cable travel in feet. 27. Unlock and Restore electrical power. 28. Operate the hoist to raise the backstop to its stowed position. Since each rotation of the drum is about 14.2 inches, the hoist should stop short of desired stowage; the drum rotates at the same speed as the limit shaft. WARNING: Always directly observe the movement of the backstop whenever operating, watching for mechanical interference! 29. Remember to appropriately lock and unlock the electrical power. Adjust the up direction limit switch until the backstop is set. 30. Place the cover on the limit box and secure the screw with a screwdriver. 31. The installation process is finished.

QR4 Manual Page 13 of 15 Turn key-switch towards up to raise Turn key-switch towards down to lower WARNING: This unit is intended for indoor use only! WARNING: This unit is to be installed at least 12 feet or greater above floor! Appendix A OPERATING INSTRUCTIONS WARNING: Do not operate when under the influence of alcohol mind altering substances! hoist or WARNING: Always directly observe the movement of the backstop whenever operating, watching for mechanical interference. WARNING: Do not operate hoist when people are underneath backstop or in the path of motion. Failure of cable may lead to injury or death. Use a fall protection device on the backstop! WARNING: Do not operate hoist during electrical storms or severe power line voltage fluctuations! Operating motor at voltages or frequencies other than the nameplate ratings will damage motor and may cause fire or explosion.

QR4 Manual Page 14 of 15 Appendix B WIRING DIAGRAM

QR4 Manual Page 15 of 15 Appendix C OPERATIONAL SPECIFICATIONS UNIT WEIGHT LENGTH WIDTH HEIGHT POWER VOLTAGE CURRENT FREQUENCY DUTY CAPACITY TRAVEL SPEED WINCH-QR4 68 LBS 22.85 in 12.75 in 13.45 in 120 AC 11.5 FLA 60 HZ Intermittent 10 min. 1000 LBS Max 35 Feet 9 ft/min Max