HAZARD ASSESSMENT - Electrical 01 Electrical control panels must be accessible with free and ready access. Blocked access to circuit breaker box. Poor access to electrical disconnects.
HAZARD ASSESSMENT - Electrical 02 Electrical control panels must be accessible with free and ready access. Good access to electrical panels. Good access to electrical panels.
HAZARD ASSESSMENT - Electrical 03 Electrical control panels and components must be labeled for their purpose. Good purpose labeling of electrical disconnects. Good purpose labeling of circuit breakers.
HAZARD ASSESSMENT - Electrical 04 Electrical control panels must be labeled for their magnitude. Good magnitude labeling of electrical disconnect. No magnitude labeling on electrical disconnect.
HAZARD ASSESSMENT - Electrical 05 Electrical control panels must be closed and secured. Open electrical panel. Open electrical panel.
HAZARD ASSESSMENT - Electrical 06 Electrical control panels, junction boxes and switches must be free of openings into internal electrical components. Opening into electrical disconnect. Missing cover plate in circuit box.
HAZARD ASSESSMENT - Electrical 07 Electrical control panels, junction boxes and switches must be free of openings into internal electrical components. Missing cover on junction box. Exposed wiring into motor housing.
HAZARD ASSESSMENT - Electrical 08 Electrical components must be protected from environmental and workplace conditions. Acid corroded electrical disconnect. Water corroded electrical enclosure.
HAZARD ASSESSMENT - Electrical 09 Materials or excessive dust must not be stored or built up on top of electrical control panels. Improper storage of materials on top of electrical panel.
HAZARD ASSESSMENT - Electrical 10 Flexible electrical cords must be free from frays, splices, exposed wiring or other damaged conditions. Frayed wire. Exposed wiring.
HAZARD ASSESSMENT - Electrical 11 Electrical plugs must be in good condition with the grounding prong in place (on grounded lines). Damaged plug wiring. Missing grounding prong.
HAZARD ASSESSMENT - Electrical 12 Extension cords must only be used for temporary wiring and NOT permanently secured. Improper use of extension cord as permanent wiring. Improper use of extension cord as permanent wiring.
HAZARD ASSESSMENT - Electrical 13 Extension cords must be protected from traffic and damage. Unprotected extension cord in exit way.
HAZARD ASSESSMENT - Electrical 14 Multiple outlet electrical boxes (designed for mounting) must not be used as extension cords. Improper and damaged extension cord. Improper and damaged extension cords.
HAZARD ASSESSMENT - Electrical 15 Multiple outlet power strips must be used within their capacity and not as permanent replacements for fixed outlets. Improper use of power strip as fixed outlet. Improper use of power strip.
HAZARD ASSESSMENT - Electrical 16 Flexible electrical cords must be maintained away from wet location. Flexible extension cord used in potentially wet location. Unprotected flexible extension cord used in wet location.
HAZARD ASSESSMENT - Electrical 17 Lighting equipment and components must be maintained in good condition. Damaged cover for light fixture. Lighting in poor condition.
HAZARD ASSESSMENT - Electrical 18 Ground Fault Circuit Interrupter (GFCI) services must be used in wet locations. Proper GFCI service. Proper GFCI service cord.
HAZARD ASSESSMENT - Electrical 19 Hazardous location fixtures must be used in areas with flammable materials. Examples: -Flammable Storage Rooms -Flammable Paint Spray Booths -Chemical Storage Areas. Proper hazardous location lighting.
HAZARD ASSESSMENT - Electrical 20 Insulated hand tools in good condition must be used around electrical components. Properly insulated and damaged/ taped electrician s screwdriver. Inappropriate use of a crow bar to remove a fuse from a junction box.
HAZARD ASSESSMENT - Electrical 21 Housing for hand and portable electrical tools must be in good condition. Proper housing for portable drill. Damaged housing for drill.