Technical data sheet S_Series S_300 Vacuum pump systems

Similar documents
EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Transformer oil cooler ALFA A02

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Solenoid valves Type EVU

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Multistage high-pressure multistage centrifugal pumps

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO-D

Vacuum drying oven for non-flammable solvents

CRN A-F-G-E-HQQE 3x400D 50 HZ

VDL 53 - Vacuum drying oven for flammable solvents

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

A E R Z E N E R M A S C H I N E N F A B R I K G M B H AERZEN POSITIVE DISPLACEMENT BLOWERS. for conveying of air and neutral gases for high vacuum

Direct steam injection humidifiers

MEMBRANE VACUUM MINI PUMPS

Power consumption (kw)

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

ThermoSorb Desiccant Dryers

Digital inductive conductivity transmitter


Solar Hot Water Heaters

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

ECOCIAT. Domestic hot water heat recovery unit

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Refrigeration Compressed Air Dryer Buran Ultrapulse

Under sill units. Type FSL-B-ZAS

PS1800 Centrifugal Pumping Systems

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

How To Use A Flowmeter

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

STERILIZERS, LABORATORY DRYING OVENS

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Solenoid valves 2/2-way direct-operated Type EV210A

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Butterfly Valves PN 6/10/16 for flanged connection

DRYPOINT RA REFRIGERATION DRYER RANGE

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Fluxi 2000/TZ Turbine Gas Meter

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Thermostatic valve Type AVTA

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

TWE+TTA TWE+TWA T.R.

79 GAUGE / THERMOMETER H N O

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

REGULATORS 175/153 Series

Surface Technology. Centrifugal Fan GMD

Laing industrial pumps

Compact pressure switch Flameproof enclosure Ex d Model PCA

CRK A-W-A-BUBV

Adsorption air dryers ADS 1 215

Series description: Wilo-Drain TC 40

Thermostatic element RAVV for 2-way valves

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

CRAC Precision climate control units for data centres

Automatic Bypass Control AVDO

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

IV. Rear Mount System

3/2-way Solenoid Valve, direct-acting, NC or NO

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Self-operated Temperature Regulators Temperature Regulator Type 1u

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Test Code: 8297 / Version 1

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Climate chamber with illumination

Condensate water pump with neutralisation system

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

Conlift1, Conlift2, Conlift2 ph+

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Specials. designed. 3rd edition 2015 English. for scientists 1

300 Series PA Pump and Cooler Assemblies

Split units TH with hermetic compressors

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

MAC-120HE-01 Air-Cooled Chiller

Horizontal Jet Pumps 1/3-1-1/2 HP

Refrigeration and air conditioning Date: 10/2013

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

Transcription:

Technical data sheet S_Series S_300 Vacuum pump systems General information 2BL2 501-0K Standard version for use in general industries 2BL2 501-0H version with external two-chamber preseparator with automatic drainage 2BL2 901-0H version with plate heat exchanger, integrated two-chamber preseparator and all necessary tubings and valves for the CIP process The vacuum pump systems S_300 are highly robust and reliable. They are provided in standard materials as well as in stainless steel, suitable for the integration in the CIP process for food and beverage applications. The patented vacuum systems S_300 are equipped with an after cooler for discharge air. Therefore in most applications continuos operating water supply is not needed, and your operating costs are reduced too. The system is also available in stainless steel to be used in food and brewery applications. CIP piping incl. magnetic valves for integration into existing CIP process available as option for stainless steel version. Pre separators are available in standalone and integrated design. If a coolant circuit is installed in your plant, the fan cooled heat exchanger can be exchanged by a plate heat exchanger. The caracteristics can be relevant improved by reducing the operating liquids temperature, i.e. with a plate heat exchanger which is available as an option. Gardner Denver Deutschland GmbH Page 1/6 Changes without prior notice

Characteristics The characteristics of liquid ring vacuum pumps depend on the temperature of their operating liquid and the inlet gas. Our characteristics are valid for an operating liquid temperature of 15 C when operated with a plate heat exchanger. When an air-water-cooler (fan) is used, the characteristic is influenced by the ambient temperature. To have a practical relevant point of reference, the characteristics for S_Series with air-water cooler are valid for an ambient temp. of 20 C. The performance of the vacuum systems is improved with colder operating liquid. Also the humidity of the suction medium affects the suction capacity. For the versions with plate-heat exchanger we provide characteristics for dry and wet air operation. Valid for suction temperature of 20 C and an operating liquid temperature of max. 15 C by using a plate-heat-exchanger. End vacuum: 33 mbar abs. Suction air humidity: up to 50 % Valid for suction temperature of 20 C and an operating liquid temperature of max. 15 C by using a plate-heat-exchanger. End vacuum: 33 mbar abs. Suction air humidity: 50-100 % Gardner Denver Deutschland GmbH Page 2/6 Changes without prior notice

Characteristics End vacuum: 50 mbar abs. Valid for ambient and suction temperature of 20 C. Without power requirement of the fan. Please see technical selection data. An inlet pressure of 10 mbar abs. can be achieved by connecting a gas ejector (see accessories). The gas ejector can be mounted directly onto the vacuum pump. Gardner Denver Deutschland GmbH Page 3/6 Changes without prior notice

Materials Standard version 2BL2 351-0K 2BL2 501-0K 2BL2 801-0K 2BL2 901-0K Dimensions L x D x H (aprox. mm) o.r. 1535 x 1260 x 1600 2280 x 1310 x 1790 2345 x 1410 x 1895 Connection suction side DN80 PN16 Pump: Impeller Alu-Bronze Casing Cast iron, ceramic coated Port plate Cast iron Slide ring sealing Graphite/Ceramic Frame Steel, painted Separator Steel, galvanized and painted Condensate separator Steel, galvanized and painted Condensation cooler Air-water-cooler (fan) Steel, aluminium, copper Flanges Steel, painted or galvanized Fittings Plastic ( PA,PVC,PP) Houses PVC with wire enforcement materials version 2BL2 351-0H 2BL2 501-0H 2BL2 801-0H 2BL2 901-0H Dim. LxDxH (appr. mm) o. r. 1485x1260x1600 2120x1410x1800 2270x1410x1895 With included preseparator 1300x2100x2186 o. r. 2850x2343x1500 2850x2343x1500 Connection suction side DN80 PN16 Pump: Impeller Casing Port plate Slide ring sealing Graphite/Ceramic Frame Separator Condensate separator Condensation cooler Air-water-cooler (fan), Aluminium Tubings: Flanges Fittings materials Technical selection data 2BL2 351 2BL2 501 2BL2801 2BL2901 Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Nominal voltage vacuum pumps [V] Nominal voltage fan [V] 400 / 460 400 / 460 400 / 460 400 / 460 Rated power pumps [kw] 7,5 / 11,4 12 / 18 22 / 32,4 24 / 36 Rated power fan [kw] 0,78 / o.r. 0.74 / 1.15 1.25 / 2 1) 2) 1.9 / 3.1 1.25 / 2 Rated current pumps [A] 38 / 39 38 / 40 2 x 35 2 x 38 / 40 Rated current fan [A] 1,35 / o.r. 1.65 / 1.95 4.2 / 5.4 2.9 / 3.5 Total mass standard [kg] o.r. 590 3) 770 3) 920* Total mass stainless steel [kg] ~ 1050 ~ 1100 ~ 1200 ~ 1300 Sound pressure (db(a)) 70 / 76 75 / 76 76 / 80 77 / 79 Fill quantity (aprox. ltr.) 70 70 70 70 1) stainless steel 2) standard version 3) without option S30 (switchboard), without preseparator, without CIP-tubing Gardner Denver Deutschland GmbH Page 4/6 Changes without prior notice

P & I - Diagram 1 vacuum pump 2 separator, water tank 3 air-water cooler 4 condensation cooler 5 condensate separator Main dimensions 2BL2 351... Gardner Denver Deutschland GmbH Page 5/6 Changes without prior notice

Main dimensions 2BL2 50... 2BL2 80, 2BL2 90... 2BL2 901... with integrated 2-chamber separator, magnetic valves and CIP tubing Gardner Denver Deutschland GmbH Page 6/6 Changes without prior notice