42WH Nominal cooling capacity kw Nominal heating capacity kw

Similar documents
york air-conditioning products Residential & VRF News 2015

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Cooling kw Heating kw

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

LG Electronics AE Company, Commercial Air Conditioning

SWIMMING POOL HEAT PUMP Owners Manual

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Air Conditioners Technical Data

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

HP switch LP switch Discharge thermo Comp. Surface thermo

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Hot Water. Heat pump water heaters. Residential and Commercial R410a

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

HEAVY DUTY STORAGE GAS

YUTAKI S. Domestic Heating

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Delivering exceptional performance and Ecovalue. Ecocent

EHDC. Cooling system for Data Center and server cabinets.

Versati Air to Water Heat Pump

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

We have been working in an ideal climate for thirty years.

Under sill units. Type FSL-B-ZAS

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

FAN COIL. Technibel is a trademark of Nibe Energy System France used under license

HIGH PERFORMANCE CHILLED WATER SYSTEMS. EarthWise HVAC. EarthWise HVAC High Performance CHW Plants

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Technical data. Danfoss DHP-A

Product catalog UNT-PRC011-E4

The natural ombination

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Inverter Air Conditioning for Light Commercial Use

Elements of Energy Efficiency in Data Centre Cooling Architecture

CE6500 Energy Recovery Ventilator

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

HVAC Systems: Overview

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Butterfly Valves PN 6/10/16 for flanged connection

Air Conditioners Technical Data

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

DUCTED AIR CONDITIONING SOLUTIONS

Unico Inverter. Unique and efficient.

The natural ombination

HDA

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

Element D Services Heating, Ventilating, and Air Conditioning

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

AQUAREA AIR TO WATER HEAT PUMP // HEATING AND COOLING SYSTEMS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Explosion-Proof Electric Unit Heaters

Defining Quality. Building Comfort. Heating and Cooling Coils

Energy Efficiency HOSPITALITY.

Gree Solar Hybrid Hi Wall Inverter Air Conditioner


SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

FULL DC INVERTER SYSTEMS

Chilled Water Fan Coil Unit

APC APPLICATION NOTE #112

ECOCIAT. Domestic hot water heat recovery unit

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

The space saving solution.

Water Volume Calculation in Hydronic Heating & Cooling Systems

TWE+TTA TWE+TWA T.R.

Cool Design for Homes and Offices

Appendix - Controllers 179

Hot Water Heat Pump Catalogue

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Samsung Room Air Conditioning

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. Typical Applications

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

PFT Two stage axial fan The high pressure fan for modern boiler plants

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

Fläkt Woods Building Future

Itho Products for Hot and Boiling water. product-

Direct Fresh Air Free Cooling of Data Centres

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Commercial Hot Water. Make a difference...

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Split units TH with hermetic compressors

IR410AI. The flexible solution. Simple, one touch control

FTQ. Daikin Inverter Ducted Heat Pump

GREE, MAKING BETTER AIR CONDITIONERS

Transcription:

Hydronic High-Wall-Fan Coil Units 42WH Nominal cooling capacity 1.4-2.1 kw Nominal heating capacity 1.9-3.2 kw These elegant hydronic high-wall units complete the Carrier range of water-cooled indoor units. They are available with a standard or fully featured back panel, depending on the application needs, and can be used in conjunction with every other indoor terminal. The 42WH units combine stylish design and clear lines with optimum comfort and performance. 42WH units are available as cooling only models (42WHC) and with electric heaters (42WHE). Features 1 The units are ideal for hotels, but also suitable for a wide range of other commercial and residential applications. 1 The new hydronic high-wall unit is designed to fit neatly on any appropriate wall, above the occupant s normal eye level. This frees valuable floor space. 1 The standard version has extensions to cover the pipes. 1 The tangential fan brings new air to the ambient air very quietly and unobtrusively. This means optimum comfort can be achieved quickly and easily. 1 In the fully-featured version three-way valves are supplied as standard. 1 The 42WH unit offers automatic temperature control. This is the only model in its class to include cold draft prevention as a standard feature. By automatically controlling the fan in response to changes in the water temperature, the hydronic high-wall units help create an ideal environment, anywhere from small bedrooms to large reception areas, from shops to office blocks. 1 After a power failure the unit will restart automatically without any change in user settings. 1 42WH units are extremely simple to install and to maintain. For routine servicing they are easily accessible from one or both sides, and if needed, one person can service the unit in less than 10 minutes. 1 42WH units can be matched to any water chiller from 4 to 100 kw to suit your individual application requirements. Fully-featured back panel

Physical and electrical data Model 42WHC 016 42WHE 016 42WHC 020 42WHE 020 42WHC 028 42WHE 028 Total cooling capacity kw 1.43 1.43 1.65 1.65 2.10 2.10 Sensible cooling capacity kw 1.08 1.08 1.35 1.35 1.95 1.95 Water flow rate (cooling) l/s 0.068 0.068 0.079 0.079 0.100 0.100 Water pressure drop (cooling) kpa 14/22* 14/22* 19/30* 19/30* 34/50* 34/50* Heating capacity kw 1.94 1.94 2.30 2.30 3.20 3.20 Electric heaters W - 500-1000 - 1000 Air flow rate (low/medium/high) l/s 47/59/69 47/59/69 72/81/86 72/81/86 111/123/131 111/123/131 Power input W 19 19 27 27 28 28 Current drawn A 0.08 0.08 0.12 0.12 0.12 0.12 Weight, unit kg 14.5 14.5 14.5 14.5 15.0 15.0 Weight, fully-featured back panel with valves kg 5 5 5 5 5.5 5.5 Weight, standard back panel kg 4.5 4.5 4.5 4.5 4.5 4.5 Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 The above data refers to Eurovent conditions. Cooling conditions: 27 C db/19 C wb air temperature, 7 C/12 C entering and leaving water temperature at high fan speed Heating conditions: 20 C air temperature, 50 C entering water temperature, same water flow rate as in cooling, at high fan speed. * Values with valves installed. Unit dimensions, mm 42WH A B C D* 016 800 290 190 45 020 800 290 190 45 028 800 337 215 45 * Dimension D refers to the fully-featured back panel, and basic back panel only. For the standard back panel please refer to the appropriate drawings. Fully featured back panel 42WH A 016-020 282 028 320.5 Basic back panel Same as fully featured back panel, but without valves, water connections only from the rear to fit perfectly behind the unit. Standard back panel Offered with detachable sides to allow water connections to enter from left or right-hand side. 42WH A 016-020 282 028 320.5 All dimensions are in mm.

Example of side connections with standard back panel Clearances, mm Water connections All units Outside connection diameter (inch), standard panel without valves Inside connection diameter (inch), fully-featured panel with valves Outside connection diameter (inch), fully-featured panel with valves 3/8" gas male 3/8" gas male 3/8" gas female 3/8" gas male

Cooling capacity, two-pipe coil (with fan at high speed) Entering water Water temperature Entering air 42WH 016 42WH 020 42WH 028 temperature C rise K temperature C Total Sensible Total Sensible Total Sensible wb db kw kw kw kw kw kw 6 3 15 21 1.09 0.96 1.28 1.09 1.66 1.53 6 5 15 21 0.76 0.76 0.94 0.92 1.08 1.08 6 7 15 21 0.54 0.54 0.74 0.74 0.78 0.78 6 9 15 21 0.45 0.45 0.57 0.57 0.63 0.63 7 3 15 21 0.95 0.88 1.09 1.01 1.46 1.41 7 5 15 21 0.67 0.67 0.84 0.84 0.94 0.94 7 7 15 21 0.48 0.48 0.65 0.65 0.69 0.69 7 9 15 21 0.39 0.39 0.49 0.49 0.54 0.54 9 3 15 21 0.74 0.74 0.84 0.84 1.15 1.15 9 5 15 21 0.50 0.50 0.65 0.65 0.68 0.68 9 7 15 21 0.37 0.37 0.47 0.47 0.52 0.52 9 9 15 21 0.27 0.27 0.31 0.31 0.37 0.37 11 3 15 21 0.57 0.57 0.66 0.66 0.86 0.86 11 5 15 21 0.35 0.35 0.47 0.47 0.49 0.49 11 7 15 21 0.25 0.25 0.30 0.30 0.34 0.34 6 3 17 23 1.47 1.09 1.75 1.26 2.24 1.75 6 5 17 23 1.03 0.89 1.34 1.08 1.48 1.37 6 7 17 23 0.69 0.69 0.97 0.91 1.05 1.05 6 9 17 23 0.56 0.56 0.74 0.74 0.80 0.80 7 3 17 23 1.29 1.01 1.56 1.17 1.97 1.63 7 7 17 23 0.61 0.61 0.84 0.83 0.87 0.87 7 9 17 23 0.51 0.51 0.65 0.65 0.71 0.71 9 3 17 23 1.00 0.88 1.15 1.00 1.52 1.41 9 5 17 23 0.69 0.69 0.84 0.83 0.97 0.97 9 7 17 23 0.48 0.48 0.65 0.65 0.69 0.69 9 9 17 23 0.39 0.39 0.49 0.49 0.54 0.54 11 3 17 23 0.74 0.74 0.84 0.84 1.16 1.16 11 5 17 23 0.51 0.51 0.65 0.65 0.70 0.70 11 7 17 23 0.37 0.37 0.47 0.47 0.52 0.52 11 9 17 23 0.27 0.27 0.31 0.31 0.37 0.37 13 3 17 23 0.57 0.57 0.65 0.65 0.87 0.87 13 5 17 23 0.35 0.35 0.47 0.47 0.49 0.49 13 7 17 23 0.25 0.25 0.30 0.30 0.34 0.34 6 3 19 25 1.94 1.24 2.26 1.42 2.98 1.99 6 5 19 25 1.40 1.02 1.86 1.25 2.01 1.59 6 7 19 25 0.96 0.83 1.41 1.07 1.25 1.19 6 9 19 25 0.68 0.67 1.00 0.90 0.98 0.98 7 3 19 25 1.76 1.17 2.07 1.33 2.69 1.87 7 5 19 25 1.23 0.95 1.65 1.16 1.78 1.49 7 7 19 25 0.83 0.76 1.20 0.98 1.10 1.10 7 9 19 25 0.62 0.62 0.85 0.82 0.89 0.89 9 3 19 25 1.39 1.01 1.66 1.17 2.09 1.63 9 5 19 25 0.95 0.82 1.22 0.99 1.35 1.27 9 7 19 25 0.63 0.63 0.86 0.83 0.87 0.87 9 9 19 25 0.51 0.51 0.65 0.65 0.71 0.71 11 3 19 25 1.04 0.87 1.23 1.00 1.59 1.40 11 5 19 25 0.70 0.70 0.86 0.83 1.00 1.00 11 7 19 25 0.48 0.48 0.65 0.65 0.69 0.69 11 9 19 25 0.39 0.39 0.48 0.48 0.54 0.54 13 3 19 25 0.76 0.74 0.84 0.83 1.17 1.17 13 5 19 25 0.53 0.53 0.65 0.65 0.72 0.72 13 7 19 25 0.37 0.37 0.47 0.47 0.52 0.52 13 9 19 25 0.27 0.27 0.31 0.31 0.37 0.37 6 3 19 27 1.93 1.41 2.25 1.60 2.97 2.27 6 5 19 27 1.47 1.21 1.85 1.43 2.20 1.92 6 7 19 27 1.10 1.02 1.43 1.25 1.52 1.52 6 9 19 27 0.82 0.82 1.12 1.09 1.16 1.16 7 3 19 27 1.75 1.33 2.06 1.51 2.70 2.16 7 5 19 27 1.43 1.08 1.65 1.35 2.10 1.95 7 7 19 27 0.98 0.96 1.26 1.18 1.40 1.40 7 9 19 27 0.75 0.75 1.01 1.01 1.07 1.07 9 3 19 27 1.42 1.19 1.65 1.35 2.22 1.94 9 5 19 27 1.08 1.02 1.26 1.18 1.60 1.59 9 7 19 27 0.82 0.82 1.01 1.01 1.14 1.14 9 9 19 27 0.62 0.62 0.83 0.83 0.89 0.89 11 3 19 27 1.14 1.06 1.25 1.18 1.78 1.72 11 5 19 27 0.88 0.88 1.02 1.02 1.33 1.33 11 7 19 27 0.65 0.65 0.84 0.84 0.88 0.88 11 9 19 27 0.51 0.51 0.65 0.65 0.71 0.71 13 3 19 27 0.92 0.92 1.01 1.01 1.47 1.47 13 5 19 27 0.71 0.71 0.84 0.84 1.03 1.03 13 7 19 27 0.49 0.49 0.65 0.65 0.69 0.69 13 9 19 27 0.39 0.39 0.48 0.48 0.54 0.54 Eurovent conditions Note: The maximum operating water flow rate is 0.219 l/s (790 l/h) for size 016-020 and 0.365 l/s (1315 l/h) for size 028.

Cooling capacity, two-pipe coil (with fan at high speed) Entering water Water temperature Entering air 42WH 016 42WH 020 42WH 028 temperature C rise K temperature C Total Sensible Total Sensible Total Sensible wb db kw kw kw kw kw kw 6 5 21 29 1.94 1.35 2.40 1.59 2.83 2.13 6 7 21 29 1.43 1.14 1.96 1.41 2.02 1.77 6 9 21 29 1.04 0.96 1.51 1.24 1.39 1.39 7 3 21 29 2.24 1.47 2.60 1.67 3.48 2.38 7 5 21 29 1.74 1.27 2.20 1.51 2.56 2.02 7 7 21 29 1.29 1.09 1.74 1.33 1.82 1.66 7 9 21 29 0.92 0.90 1.32 1.16 1.28 1.28 9 3 21 29 1.87 1.32 2.19 1.50 2.87 2.14 9 5 21 29 1.40 1.14 1.76 1.34 2.09 1.81 9 7 21 29 1.03 0.96 1.32 1.17 1.44 1.43 9 9 21 29 0.76 0.76 1.02 1.01 1.07 1.07 11 3 21 29 1.49 1.18 1.76 1.34 2.31 1.92 11 5 21 29 1.13 1.01 1.32 1.17 1.66 1.59 11 7 21 29 0.83 0.83 1.02 1.01 1.17 1.17 11 9 21 29 0.62 0.62 0.833 0.83 0.89 0.89 13 3 21 29 1.19 1.05 1.320 1.17 1.85 1.71 13 5 21 29 0.89 0.89 1.020 1.01 1.35 1.35 13 7 21 29 0.66 0.66 0.835 0.84 0.91 0.91 13 9 21 29 0.51 0.51 0.651 0.65 0.71 0.71 6 5 23 31 2.49 1.50 2.980 1.74 3.72 2.37 6 7 23 31 1.89 1.27 2.560 1.58 2.62 1.97 6 9 23 31 1.37 1.08 2.090 1.40 1.81 1.60 7 5 23 31 2.30 1.43 2.770 1.66 3.41 2.26 7 7 23 31 1.68 1.20 2.340 1.49 2.38 1.87 7 9 23 31 1.24 1.03 1.850 1.32 1.62 1.50 9 5 23 31 1.90 1.28 2.350 1.50 2.75 2.02 9 7 23 31 1.37 1.08 1.880 1.33 1.93 1.68 9 9 23 31 0.98 0.91 1.390 1.16 1.31 1.31 11 3 23 31 2.01 1.32 2.340 1.49 3.07 2.13 11 5 23 31 1.48 1.13 1.890 1.33 2.21 1.81 11 7 23 31 1.09 0.97 1.400 1.16 1.50 1.45 11 9 23 31 0.78 0.78 1.050 1.00 1.08 1.08 13 3 23 31 1.59 1.17 1.880 1.33 2.42 1.90 13 5 23 31 1.18 1.01 1.410 1.17 1.74 1.60 13 7 23 31 0.85 0.84 1.040 1.01 1.20 1.20 13 9 23 31 0.63 0.63 0.834 0.83 0.89 0.89 Eurovent conditions Note: The maximum operating water flow rate is 0.219 l/s (790 l/h) for size 016-020 and 0.365 l/s (1315 l/h) for size 028. Correction factors 42WH Capacity Fan speed High Medium Low 016 Total 1 0.90 0.70 Sensible 1 0.89 0.69 020 Total 1 0.93 0.81 Sensible 1 0.93 0.80 028 Total 1 0.97 0.86 Sensible 1 0.97 0.86 Note: These factors should be considered mean values. For more accurate sizing please use the ECAT software. Heating capacity, two-pipe coil (with fan at high speed) Water flow rate Available temp. 42WHE 016 42WHE 020 42WHE 028 l/h l/s difference, K kw kw kw 100 0.03 20 0.98 1.09 1.16 150 0.04 20 1.17 1.31 1.50 230 0.06 20 1.33 1.50 1.85 283 0.08 20 1.39 1.57 2.01 342 0.10 20 1.44 1.62 2.13 400 0.11 20 1.47 1.65 2.21 600 0.17 20 1.54 1.73 2.41 800 0.22 20 1.57 1.76 2.51 1200 0.33 20 1.61 1.79 2.63 100 0.03 30 1.51 1.63 1.79 150 0.04 30 1.79 1.97 2.33 230 0.06 30 2.00 2.24 2.84 283 0.08 30 2.11 2.30 3.06 342 0.10 30 2.17 2.42 3.20 400 0.11 30 2.22 2.48 3.37 600 0.17 30 2.32 2.58 3.65 800 0.22 30 2.37 2.64 3.80 1200 0.33 30 2.43 2.69 3.97 150 0.04 40 2.43 2.62 3.16 230 0.06 40 2.72 2.99 3.86 283 0.08 40 2.83 3.12 4.13 342 0.10 40 2.92 3.22 4.36 400 0.11 40 2.99 3.30 4.53 600 0.17 40 3.11 3.44 4.90 800 0.22 40 3.18 3.52 5.10 1200 0.33 40 3.25 3.59 5.32 230 0.06 50 3.47 3.83 4.87 283 0.08 50 3.62 4.00 5.24 342 0.10 50 3.74 4.14 5.54 400 0.11 50 3.82 4.24 5.77 600 0.17 50 3.99 4.43 6.26 800 0.22 50 4.08 4.52 6.53 1200 0.33 50 4.18 4.62 6.82 Available temperature difference = entering hot water temperature minus entering air dry bulb temperature. Maximum operating temperature 60 C, maximum operating pressure 14 bar.

Air throw (cooling mode), m 42WH 016 020 028 High speed 3.2 4.0 5.0 Medium speed 2.7 3.8 4.7 Low speed 2.2 3.3 4.2 1. With louvres adjusted in cooling position. 2. The air throw is defined as the distance at which the air flow speed falls to 0.2 m/s. 3. The values are to be considered as indicative, as they may vary according to the type of ceiling, room dimensions and even the furniture. Coil water content 42WH 016 020 028 Water content, l 0.6 0.6 0.7 Operating limits Water circuit Maximum water-side pressure 1400 kpa Minimum entering water temperature +6 C Maximum entering water temperature +60 C Maximum entering water temperature with electric heaters +45 C Room air Minimum temperature 5 C* Maximum temperature 32 C Power supply Nominal single-phase voltage 230 V, 50 Hz Operating voltage limits 198 V-264 V * If the room temperature can go down to 0 C, it is advisable to empty the water circuit to avoid damage caused by ice. Electrical data (units with heaters) 42WH 016 020 028 Current A 2.3 4.56 4.56 Power input W 519 1027 1028 Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 Sound levels 42WH Lw(A) Lp(A) NR High speed Medium speed Low speed High speed Medium speed Low speed High speed Medium speed Low speed 016 40 35 30 31 26 21 27 22 17 020 44 42 38 35 33 29 31 30 24 028 49 47 44 40 38 35 37 35 32 Sound pressure levels in db(a) and noise ratings NR are for a ceiling-installed unit and measured in a room with a volume of 100 m 3 and 0.5 seconds reverberation time. Lp(A) - Sound pressure level, db(a) Lw(A) - Sound power level, db(a) NR - Noise rating, db(a)

Pressure drops 3-way valve assembly in bypass condition 10 Bypass kpa 1 0,1 100 (0.03) 1000 (0.28) 10000 (2.78) l/h (l/s) 3-way valve assembly in open condition 100 kpa 10 3-way valve + flexible pipes 1 100 (0.03) 1000 (0.28) 10000 (2.78) l/h (l/s) Coil 1000 100 kpa 10 Size 028 Sizes 016, 020 1 100 (0.03) 1000 (0.28) 10000 (2.78) l/h (l/s)

Order No. 14215-20, 09.2003. Supersedes order No. New. Manufacturer reserves the right to change any product specifications without notice. Manufactured by: Carrier SpA, Villasanta, Italy. Printed on Totally Chlorine Free Paper. Printed in the Netherlands.