Manatronics 48V / 200 Amp Load

Similar documents
MODEL 1211 CURRENT PREAMPLEFIER

DCS Series 1 kw, 1.2 kw, & 3 kw

SL Series AC and DC Electronic Loads

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

KONSTANTER SPL / SPL Programmable Electronic Load

1.44 kw Programmable DC Power Supplies XLN Series

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

High Power Programmable DC Power Supplies PVS Series

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

Multi-Range Programmable DC Power Supplies 9115 Series

DC Electronic Loads 8500 series

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

ST Series POWER SUPPLIES USER INSTRUCTIONS

STLQ ma, ultra low quiescent current linear voltage regulator. Description. Features. Application

DS 600. A contact free flux gate based current measurement sensor 600A rms

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

MPR-Systems. Mini Power Racks 1200 W W

Equivalent Circuit. Operating Characteristics at Ta = 25 C, V CC = ±34V, R L = 8Ω, VG = 40dB, Rg = 600Ω, R L : non-inductive load STK4181V

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Signal Conditioning Amplifier System

DATA SHEET. TDA1543 Dual 16-bit DAC (economy version) (I 2 S input format) INTEGRATED CIRCUITS

Voltech DC1000. Precision DC Bias Current Source

Current and voltage measuring relays

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CA723, CA723C. Voltage Regulators Adjustable from 2V to 37V at Output Currents Up to 150mA without External Pass Transistors. Features.

Kit 27. 1W TDA7052 POWER AMPLIFIER

I STAR COMPUTER CO., LTD

unit : mm With heat sink (see Pd Ta characteristics)

Power Supplies 3. SDN-P DIN Rail Series

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

HA-5104/883. Low Noise, High Performance, Quad Operational Amplifier. Features. Description. Applications. Ordering Information. Pinout.

INTEGRATED CIRCUITS DATA SHEET. TDA W BTL mono audio amplifier. Product specification File under Integrated Circuits, IC01

FREJA 300 Relay Testing System

TORKEL 820 Battery Load Unit

LM117 LM317A LM317 3-Terminal Adjustable Regulator

LM1084 5A Low Dropout Positive Regulators

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Multi-Range Programmable DC Power Supplies 9115 Series

AAV003-10E Current Sensor

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

LM138 LM338 5-Amp Adjustable Regulators

Everything you need for protection scheme testing

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

Description. Table 1. Device summary

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

28V, 2A Buck Constant Current Switching Regulator for White LED

GT Sensors Precision Gear Tooth and Encoder Sensors

Thyristor-controlled power supplies and battery chargers

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Wideband Driver Amplifiers

LM337. Three-terminal adjustable negative voltage regulators. Features. Description

Series AMLDL-Z Up to 1000mA LED Driver

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

BB800 Off-Grid Solar System

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram

Photovoltaic Solar Energy Unit EESFB

Advanced Monolithic Systems

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

NC2000 Charge Controller for Nickel-Cadmium and Nickel-Metal Hydride Batteries

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

LM381 LM381A Low Noise Dual Preamplifier

User Manual for CH-PFC76810

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

650W Single Output Power Supply

Precision, Unity-Gain Differential Amplifier AMP03

FM TRANSMITTER & RECEIVER HYBRID MODULES. FM-RTFQ SERIES FM-RRFQ SERIES. Transmitter. Receiver. Applications

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

DPI 260 SERIES: Digital Pressure Indicators

TL783C, TL783Y HIGH-VOLTAGE ADJUSTABLE REGULATOR

1.5A Very L.D.O Voltage Regulator LM29150/29151/29152

LM78XX Series Voltage Regulators

Differential Charge Amplifier

Mobile Communications DC Sources W

CLASS-D VERTICAL DEFLECTION AMPLIFIER FOR TV AND MONITOR APPLICATION OUT CFLY + CFLY - BOOT VREG FEEDCAP FREQ. July /8

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DCP Fan Controller. Version 01/2009. The engineer s choice

Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

LDS WLED Matrix Driver with Boost Converter FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

High Common-Mode Rejection. Differential Line Receiver SSM2141. Fax: 781/ FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

TDA2004R W stereo amplifier for car radio. Features. Description

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

User manual Rev. 1.2 (17/04/2015)

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

MC78XX/LM78XX. 3-terminal 1A positive voltage regulator. Features. Description. Internal Block Digram.

LM118/LM218/LM318 Operational Amplifiers

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Transcription:

Manatronics 48V / 200 Amp Load For Battery Discharge testing and Power Supply testing 30 th Jan. 2008 Model No. BD 12-48P Product Datasheet 48V / 200 Amp Electronic Load Features: Quality Product Rugged and Reliable Design Very Cost effective Microprocessor controlled 200 Amps at 60V (continuous rating) 12kW Rated Portable very light weight Load Small case size with carrying handles Continuously variable current Constant Current operation is standard Options for CP, CR, CV modes. Completely powered from batteries. Two LCD digital panel meters for Voltage and Current Thermally safe Fan fail detect on all fans / Air flow blockage detectors Fused protection option Overvolt protection Intelligent Load feature; has built-in LVD to remove load at "End Voltage" Selectable "End Voltage" prevents deep discharge and possible damage Amplified Shunt output is available Remote enable / disable (suitable for UPS control) An Anderson SB 350A series connector for DC power connection

Introduction This particular Load has been designed to operate with 48V and 50V, (24 or 25 cells at 2V each), battery systems and is extremely cost effective. The load is continuously rated at 200 Amps at up to 60V DC, i.e. 12kW. The standard model has constant current operation. There is an option available for Constant Power, Constant Resistance and Constant Voltage. The mode selection will be via the front panel. The load current is continuously variable over the entire current range. The current is controlled via two knobs on the front panel, one coarse and one fine control. As standard there is an in-built LVD, (Low Voltage Disconnect). It is possible to select the "End Voltage" for both 48V and 50V systems with an equivalent "End Voltage" per cell from 1.55V PC up to 1.90V PC. When enabled the load monitors the overall battery Voltage and when it drops to the "End Voltage" it will automatically disconnect the load and the current will drop to zero. Thus, the Load now becomes an intelligent Load, in that if it is left unattended it will prevent deep discharge of the batteries and hence prevent any possible damage to them. When this load is used in conjunction with the Manatronics Data Logger DLM-09, (which is recommended), the "End Voltage" will be programmed from the Logger and this will automatically disconnect the load when the Logger senses that the "End Voltage" has been reached. This feature will override the LVD in the load. The Load is completely powered from the Batteries under test, i.e. no mains supply is required. Therefore tests are not terminated part way through by a temporary mains power outage. The unit uses forced air cooling. The Load is housed in a compact, rugged case with carrying handles and is ultra-lightweight for the power rating and is also completely portable. The Load may be left on site, unattended, for an extended period of time, if required. The case has various rear panel connectors and the front panel has two LCD panel meters, one for the DC input Voltage and one for the load current. There are also eight LED s to indicate the status of the Load. The load has been designed to be very reliable, easy to use and suitable for field use. It is thermally safe and has fan fail detectors on all fans together with air blockage detectors. The DC input is fused and overvoltage protection is included. The DC power connection is via an Anderson SB 350A series connector on the rear panel. Monitor points are included on the front panel for access to the internal shunt. This is also provided via a D type connector on the rear panel. Control selection is made from the front panel between Load ON, Load OFF, Data Logger Control, External Input Control, (e.g. suitable for UPS control). The rear panel has a connector to link to the Manatronics Data Logger DLM-09 or for an external load on / off control, (e.g. suitable for UPS control).

Applications Battery discharge testing. Power Supply testing Applications for Mains powered version - see EL 12-48M Telecom Rectifier testing. All purpose Power Supply testing. Load bank for Burn-in room facility.

2008 Manatronics Pty Ltd BD 12-48P Product datasheet 48V 200A Portable Battery Discharge Model Specification Absolute Maximum Ratings DC Input Voltage... -0.5 to +62V DC input current. 205A Max Voltage between the chassis and the DC connector (SB350). 50V ac or 120Vdc CAUTION: Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the unit. This is a stress only rating and operation of the unit at or above these limits is not implied. Electrical Specifications (assumes TA= -10 C to +40 C unless otherwise stated) Parameter Min Typ Max Units Comments DC Input Voltage 0 60 V DC Input Current 0 200 A Common to all Modes (e.g. CC, CP, CR and CV). Min Voltage required to achieve max current 38.4 V (see next line) Minimum series resistance 0.3 Ohm Constant current Mode Current range 1.3 200 A Demand sensitivity 40 A/V i.e. 5V demand input gives 200A. Demand sensitivity tolerance +/-0.1 % Constant power mode Power range.078 12 kw At 60V input Demand sensitivity W/ V 1V demand input sets W load. Constant resistance mode Resistance range 0.3 1,000 Ohm Demand sensitivity Constant voltage mode Voltage range 38.4 60 V Demand sensitivity See constant resistance mode text. See constant Voltage mode text. Shunt Output Accuracy (worst case) 0.5 % 50mV 500A LVD Accuracy 2 % N.B. Modes are CC CP CR or CP.

2008 Manatronics Pty Ltd BD 12-48P Product datasheet Absolute Maximum Ratings Logic input signals on rear D9 connector Enable Input Voltage... -2.0 to +14V wrt to Load DC ve. Mode select (LSB) Input Voltage -2.0 to +14V wrt to Load DC ve. Mode select (MSB) Input Voltage -2.0 to +14V wrt to Load DC ve. Fault output Voltage. -2.0 to +16V wrt to Load DC ve. Demand inputs (+/-).... -10 to +10V wrt to Load DC ve. 0V reference on D9 connector 50mA CAUTION: Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the unit. This is a stress only rating and operation of the unit at or above these limits is not implied. Electrical Specifications (assumes TA= -10 C to 40 C unless otherwise stated) Demand input Min Typ Max Units Comments CMRR of differential demand input stage 50 db For DC Common mode range of differential -10 +10 V wrt load -ve DC input demand input stage Demand current; temperature drift. 0.5 % Over the temperature range Demand current offset 15 ma Demand current linearity 0.2 % Demand Voltage, 3dB cutoff frequency, for CC, CP and CR Modes. Demand Voltage, step response, for CC, CP and CR Modes. Demand Voltage, 3dB cutoff frequency, for CV Mode only. 800 Hz can be increased at factory up to 20kHz. 1 ms 10% to 90% rise or fall 1.59 Hz Logic inputs Range Input Voltage (High Level) 7 V Internal pull up resistor 3k3 to +12V Range Input Voltage (Low Level) 4 V Enable Input Voltage (High Level) 10 V Internal pull up resistor 2k2 to +12V Enable Input Voltage (Low Level) 7 V Mode select (LSB or MSB) Input Voltage (High Level) 7 V Internal pull up resistor 22k to +12V Mode select (LSB or MSB) Input Voltage (Low Level) 3.5 V

2008 Manatronics Pty Ltd BD 12-48P Product datasheet Min Typ Max Units Comment Logic outputs Fault output high (Iout = 10uA) 11 V Fault output low (active) (sink 30mA) 1.2 V Static Characteristics Noise and ripple, psophometric 0.7 ma RMS Noise and ripple, psophometric 0.1 mv RMS see note 1. Noise and ripple, wideband 3 ma RMS Noise and ripple, wideband 0.2 mv RMS see note 1. Settling time, 0 100A step 300 us DC Input Resistance of load 1 Meg Ohm When off without fans running. Note 1. Measured at the DC input terminals with a 48V battery connected in CC mode. PHYSICAL AND OTHER SPECIFICATIONS Dimensions 482 wide x 267 (6U) high mm x 415 deep Weight 21.5 kg Dimensions inches Weight 47.5 lb. Specifications herein, are subject to change without notice. This publication supersedes and replaces all information previously supplied.

Options: Remote control box, (in place of front panel controls, for ease of use, when the load unit is under a bench or some distance away. Module for Constant Power, Constant Resistance and Constant Voltage. Ordering Information Model number: BD 12-48 P Protection Fan fail detectors Over Temperature detector Air flow blockage detectors Overvoltage detector that switches the load current to zero. DC Power input connector Anderson SB 350A series connector. External enable Both active high and low inputs provided. 48V / 200A Model Operating Area 65 60 55 Max Voltage Limit Current Limit DC Input Voltage 50 45 Availble Load Area 40 35 Unavailable Area 30 0 50 100 150 200 250 Load Current (Amperes)