SMART Position Sensor, 35 mm, 75 mm and 225 mm Linear Configurations

Similar documents
Industrial VRS Magnetic Speed Sensors

FEATURES Temperature-compensated magnetics Miniature plastic package Low voltage: 3.8 V operation

Speed Sensors Line Guide

HIH-4000 Series Humidity Sensors

Honeywell Pressure Switches Line Guide

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Fiber Optics and Liquid Level Sensors Line Guide

Heavy Duty Pressure Sensors/ Transducers Line Guide

Leak Detection System

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

AAV003-10E Current Sensor

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

AAT001-10E TMR Angle Sensor

MACTek Corporation. USB HART Interface. Users Manual

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Advantium 2 Plus Alarm

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

INTMOD485-LH Protocol Converter

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Airflow Sensors Line Guide

BroadBand PowerShield. User Manual

MICRO SWITCH Compact Precision Limit Switches. 914CE Series. Datasheet

CQM1-SF200/CS1W-SF200

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

MICRO SWITCH Compact Precision Limit Switches. 14CE Series. Datasheet

Description. Dimensions. Features. precision works better

6DF Series 6 Degrees of Freedom Inertial Measurement Unit, 6-D Motion Variant

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Series 6000 Torque measured metal bellow coupling

Model 43. Precision Low Profile Load Cell DESCRIPTION FEATURES

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Series 7500 Torque Sensor

MS900AC-B-LS User Information

Operating Manual UWAPS-TINY Series

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

Part I - Installation

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Tina 2A/B Adaptor unit

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

O C M III. Open Channel Flow Monitor

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Original instructions Tina 3A/Aps Adaptor unit

Series DFMT Digital Paddlewheel Flowmeter

2-Way Wireless Indoor Siren Installation Guide

, User s Manual

psens Pressure Measurement

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

AA and AB-Series Analog Sensors

ATL Fuel Level Sender Probes

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Nest Learning Thermostat Installation Guide. Installation step-by-step

DMX2PWM 9 Channel Dimmer Setup Manual

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Smile 11 AS-i Emergency stop with safe AS-i input node

How To Use A Cdm250 Digital Multimeter

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

READ FIRST! Universal Car/Air Adapter User Manual

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

technical data (according to IEC )

Cable Plug acc. to DIN EN , Form A

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

Plug-in relays Mini ISO relays

Model SRMD Setra Remote Monitoring Display

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

WORLD-BEAM QS30 Sensors

Analog signal converters CC-E I/I Current / current isolators

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Smart Sensing Solutions Since 1954

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Multifunction devices

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

GT Sensors Precision Gear Tooth and Encoder Sensors

-Encoder with end or hollow shaft ø10-15 mm. hollow shaft ø12 mm -Resolution max. 32 ppr. -Resolution max ppr -Magnetic sensing

Sense it! Connect it! Bus it! Solve it! EncoderS

User s Manual Inductive Analog Position Sensor BIL SmartSens No E Edition 0802

Duct Humidity Transmitter

Installation and User s Manual Global Tracking and Tracing System. GTTS-2000Bi

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

Adjustment functions for both span and shift have been incorporated

Transcription:

SMART Position Sensor, 35 mm, 75 mm and 225 mm Linear Configurations Superior Measurement. Accurate. Reliable. Thinking. DESCRIPTION The SMART Position Sensor is one of the most durable, adaptable, and lightweight linear position sensors available in the industry, enabling highly accurate motion control and improving operation efficiency and safety. Its simple, non-contact design eliminates mechanical failure mechanisms, reducing wear and tear, improving reliability and durability, and minimizing downtime. The SMART Position Sensor is a non-contacting sensing solution for absolute position sensing with enhanced accuracy. It senses the position of a magnet relative to the sensor in one of three available sensing ranges: 0 mm to 35 mm [0 in to 1.38 in] 0 mm to 75 mm [0 in to 2.95 in] 0 mm to 225 mm [0 in to 8.86 in] These sensors uses a patented combination of an ASIC (Application-Specific Integrated Circuit) and an array of MR FEATURES AND BENEFITS Reliable, durable: Non-contact design reduces wear and tear, improving reliability and durability, and minimizing downtime Easy to install: Installation takes four simple steps (1: position sensor; 2: drill holes; 3: mount sensor; 4: locate magnet actuator/make electrical connection) vs. up to 14 steps some competitive products require, simplifying installation and reducing set-up costs Rugged: As there are no moving parts within the sensor, Honeywell utilizes unique packaging materials that make the sensor more resistant to vibration, shock, and extreme temperatures Flexible: Air gap of up to 8,5 ±1,0 mm [0.334 ±0.039 in] between sensor and magnet expands application opportunities; variety of output options (analog standard and other RS232- type baud rates) are available, expanding application opportunities Cost effective: Adaptable, non-contacting design allows customers to eliminate unnecessary connections for installation, thereby reducing installation steps, installation time, and components (magnetoresistive) sensors to accurately and reliably determine the position of a magnet attached to a moving object so that the object s position can be determined or controlled. The MR array measures the output of the MR sensors mounted along the magnet s direction of travel. The output and the MR sensor sequence determine the nearest pair of MR sensors to the center of the magnet location. The output of these two MR sensors is then used to determine the position of the magnet between them. With this sensor, Honeywell has utilized MR technology through the ASIC at a level never before accomplished. The SMART Position Sensor is available in both analog output (35 mm, 75 mm and 225 mm configurations) and digital output (225 mm configuration only) for use in control systems requiring an RS232-type interface with a 57.6 kbits/s baud rate. Accurate: 35 mm configuration accurately measures values down to 0,04 mm [0.0016 in], 75 mm configuration accurately measures values down to 0,05 mm [0.002 in], while 225 mm configuration accurately measures value down to 0,14 mm [0.0055 in] (analog) and 0,0035 mm [0.000137 in] (digital) Adaptable: Electronics on board allow for flexible packaging and component compatibility with existing systems Lightweight: More than 50% lighter in weight than LVDT (Linear Variable Differential Transformer) technology Simplifies design-in: Easy-to-configure sensor array fits virtually any linear movement path Self-diagnostics feature: Can reduce equipment downtime by providing predictive maintenance input Combined patented MR sensor and ASIC technology: Provides enhanced differentiation and performance IP67 and IP69K sealing: allow use in many harsh applications Qualified for automotive grade EMI/EMC specification: Provides protection against environmental frequencies (35 mm configuration only) RoHS-compliant materials: Meet Directive 2002/95/EC

SMART Position Sensor POTENTIAL APPLICATIONS (Applies to all configurations except where noted.) INDUSTRIAL Valve position: May be used to monitor valve position so the desired amount of liquid is delivered based on the position of the valve that is opening/closing, and how long open/closed (e.g., bottling machines, food/chemical processing, water handling equipment, etc.). Material handling: May be used on a lifting device that moves cartons from one conveyor belt to another. Plastic molding: May be used for injection positioning. Cutting and slitting: May be used in paper mills to accurately control the location of the slitter before it cuts. Wafer handling: May be used to monitor if parts are properly placed. CNC machines: May be used to monitor tool depth and direction of travel. AEROSPACE Aircraft actuators: May be used to control actuator position on multiple applications in the aircraft, helping to regulate airflow to engines and environmental systems. TRANSPORTATION Engine transmissions: May be used for gear shift position for trucks (35 mm configuration only). Passenger bus level position: May be used for passenger bus leveling to simplify access for passengers and luggage. Truck-mounted crane outrigger position: May be used to determine that the outriggers are fully deployed before the lifting of objects can begin. Heavy equipment attachment identification: May be used to sense which attachments are being deployed onto heavy equipment by the strategic placement of the magnet to the sensor. The corresponding output indicates to the operator and control system which attachment is connected. Hydraulic cylinders: May be used on non-ferrous hydraulic cylinders for non-contact stroke position (225 mm configuration only). Marine motors: May be used for trim position on inboard/ outboard motors for enhanced durability and performance. 2 Honeywell Sensing and Control

Table 1. Specifications Characteristic 35 mm, 75 mm and 225 mm Linear Configurations Parameter Component 35 mm 75 mm 225 mm analog analog analog digital (SPS-L035-LATS) (SPS-L075-HALS) ( SPS-L075-HALS) (SPS-L225-HDLS) Sensing range 0 mm to 35 mm 0 mm to 75 mm 0 mm to 225 mm [0 in to 1.38 in] [0 in to 2.95 in] [0 in to 8.86 in] Resolution 0,04 mm [0.0016 in] 0,05 mm [0.002 in] 0,14 mm [0.0055 in] 0,0035 mm [0.000137 in] Supply voltage 4.75 Vdc to 5.25 Vdc 6 Vdc to 24 Vdc Output 0.55 Vdc to 4.15 Vdc 0 Vdc to 5 Vdc RS 232-type digital Supply current 20 ma max. 32 ma max. 34 ma max. 88 ma max. Linearity 1 ±1.0% full scale output ±0.4% full scale output Reverse polarity -5 V 26.4 V at 125 C [257 F] sensor only Sensitivity 103 mv/mm typ. 50 mv/mm typ. 17.78 mv/mm typ. 282.16 counts/mm typ. Update rate 476 µs 400 µs 3200 µs Baud rate 57.6 kbits/s Initial startup time 5 ms 30 ms TYCO Super Seal Termination 282087-1 flying leads integral connector Cable bend radius 40 mm [1.6 in] min. Operating temperature -40 C to 125 C [-40 F to 257 F] Storage temperature -40 C to 150 C [-40 F to 302 F] Air gap 8,5 ±1,0 mm [0.334 ±0.039 in] 3,0 ±2,5 mm [0.118 ±0.098 in] Sealing IP67, IP69K Radiated immunity 100 V/m per ISO 11452-2 Conducted immunity sensor and 100 ma BCI per ISO magnet 11452-4 Shock actuator 50 G half sine wave with 11 ms duration Vibration 20 G from 10 Hz to 2000 Hz 10 G from 10 Hz to 2000 Hz Housing material thermoplastic Approvals CE Mounting: screws ¼-20 or M6 recommended torque 6 N m to 10 N m [53.1 in lb to 88.5 in lb] Material magnet actuator neodymium iron boron Strength only 13,500 Gauss 10,000 Gauss Note: 1. Percent linearity is the quotient of the measured output deviation from the best fit line at the measured temperature to the full scale output span. NOTICE Ferrous metal within a 100 mm [3.9 in] radius of the magnet actuator may affect sensor performance. Honeywell Sensing and Control 3

SMART Position Sensor Figure 1. SPS-L035-LATS Dimensional Drawing (for reference only: mm) and Sensor Output Performance Graph Pinout 1 = Vcc 2 = GND 3 = Output Output Signal (V) 4.8 5.0 4.15 4.5 4.0 3.0 2.0 1.0 0.55 0 Reference Point A Measurement Difference (mm) 0 mm L (Delta L) 35 mm Linearity 1.0% of Full Scale Reference Point B Nominal Signal Output Curve (Through Reference Points A and B) Notes: A = Sensor B = Magnet actuator C = Mounting ear D = Sensor seating surface E = Magnet seating surface F = Sensing range L = Length 4 Honeywell Sensing and Control

35 mm, 75 mm and 225 mm Linear Configurations Figure 2. SPS-L075-HALS Dimensional Drawing (for reference only: mm) and Sensor Output Performance Graph Wiring Red = Vcc Black = GND Green = Output Output Signal (V) 5.0 4.310 4.0 3.0 2.0 Reference Point A Linearity 0.4% of Full Scale Nominal Signal Output Curve (Through Reference Points A and B) Notes: A = Sensor B = Magnet actuator C = Mounting ear D = Mounting dog L = Length 1.0 0.561 0 Measurement Difference (mm) 0 mm L (Delta L) 75 mm Reference Point B Honeywell Sensing and Control 5

SMART Position Sensor Figure 3. SPS-L225-HALS Dimensional Drawing (for reference only: mm) and Sensor Output Performance Graph Wiring Red = Vcc Black = GND Green = Output Notes: A = Sensor B = Magnet actuator C = Mounting ear D = Mounting dog L = Length Reference Point A Output Signal (V) 5.0 4.5 4.0 3.0 2.0 Linearity 0.4% of Full Scale Nominal Signal Output Curve (Through Reference Points A and B) 1.0 0.5 0 Measurement Difference (mm) 0 mm L (Delta L) 225 mm Reference Point B 6 Honeywell Sensing and Control

35 mm, 75 mm and 225 mm Linear Configurations Figure 4. SPS-L225-HDLS Dimensional Drawing (for reference only: mm) and Sensor Output Performance Graph Wiring Red = Vcc Black = GND Green = Output Notes: A = Sensor B = Magnet actuator C = Mounting ear D = Mounting dog L = Length Reference Point A Output Signal (Counts) 65535 63487 Linearity 0.4% of Full Scale Nominal Signal Output Curve (Through Reference Points A and B) 0 Measurement Difference (mm) 0 mm L (Delta L) 225 mm Reference Point B Honeywell Sensing and Control 7

SMART Position Sensor Order Guide Catalog Listing SPS-L035-LATS SPS-L075-HALS SPS-L225-HALS SPS-L225-HDLS Description SPS Series SMART Position Sensor, 35 mm linear configuration, 0 mm to 35 mm [0 in to 1.38 in] sensing range, 0.5 Vdc to 4.5 Vdc analog output, magnet actuator included (sensor also available separately) SPS Series SMART Position Sensor, 75 mm linear configuration, 0 mm to 75 mm [0 in to 2.95 in] sensing range, 0 Vdc to 5 Vdc analog output, magnet actuator included SPS Series SMART Position Sensor, 225 mm linear configuration, 0 mm to 225 mm [0 in to 8.86 in] sensing range, 0 Vdc to 5 Vdc analog output, magnet actuator included SPS Series SMART Position Sensor, 225 mm linear configuration, 0 mm to 225 mm [0 in to 8.86 in] sensing range, RS232-type digital output with 57.6 kbits/s baud rate, magnet actuator included WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA sensing.honeywell.com 000674-6-EN August 2013 Copyright 2013 Honeywell International Inc. All rights reserved.