Storage Center 6.6 Software Update Guide

Similar documents
Dell Command Integration Suite for System Center Version 4.1. Installation Guide

Fiery E100 Color Server. Welcome

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

Compellent Storage Center

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Setup for Failover Clustering and Microsoft Cluster Service

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

Extreme Networks Security Upgrade Guide

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

HP Array Configuration Utility User Guide

Managing Multi-Hypervisor Environments with vcenter Server

WhatsUp Gold v16.3 Installation and Configuration Guide

Backup & Disaster Recovery Appliance User Guide

Setting Up a Unisphere Management Station for the VNX Series P/N Revision A01 January 5, 2010

Release Notes. Contents. Release Purpose. Platform Compatibility. Windows XP and Internet Explorer 8 Update

Content Filtering Client Policy & Reporting Administrator s Guide

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

SonicOS Enhanced Release Notes TZ 180 Series and TZ 190 Series SonicWALL, Inc. Firmware Release: August 28, 2007

Parallels Containers for Windows 6.0

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Drobo How-To Guide. Topics. What You Will Need. Configure Windows iscsi Multipath I/O (MPIO) with Drobo iscsi SAN

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Setup for Failover Clustering and Microsoft Cluster Service

PlateSpin Forge 4. Rebuilding Forge 4 Appliance 2. June 14, 2014

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

StarWind iscsi SAN Configuring HA File Server for SMB NAS

Installing and Configuring vcloud Connector

HP StoreVirtual DSM for Microsoft MPIO Deployment Guide

Setup for Failover Clustering and Microsoft Cluster Service

Patching the Windows 2000 Server Operating System on S8100 Media Servers, IP600 Communications Servers, & DEFNITY ONE Communications Systems

Veeam Backup Enterprise Manager. Version 7.0

Enterprise Manager. Version 6.2. Installation Guide

FileMaker Server 15. Getting Started Guide

Using Microsoft Active Directory (AD) with HA3969U in Windows Server

Dell NetVault Bare Metal Recovery for Dell NetVault Backup Server User s Guide

XenClient Enterprise Synchronizer Installation Guide

Updating Firmware for Dell EqualLogic PS Series Storage Arrays and FS Series Appliances Beta Draft

Novell ZENworks 10 Configuration Management SP3

HP ProLiant Cluster for MSA1000 for Small Business Hardware Cabling Scheme Introduction Software and Hardware Requirements...

Easy Setup Guide for the Sony Network Camera

Maintaining the Content Server

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide

Configuring Network Load Balancing with Cerberus FTP Server

Systems Management Tools And Documentation Version 8.1 Installation Guide

Dell OptiPlex XE Watchdog Timer

INSTALLING MICROSOFT SQL SERVER AND CONFIGURING REPORTING SERVICES

Oracle Java (8u31) Installation

Moxa Device Manager 2.0 User s Guide

HP PolyServe Software upgrade guide

Installation Guide for Windows May 2016

Dell PowerVault MD Storage Array Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager Installation Guide

Release Notes. Contents. Release Purpose. Platform Compatibility. Windows XP and Internet Explorer 8 Update

Thuraya XT-DUAL. Software Upgrade Manual

CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES

Quick Start Guide FLIR Firmware Update Tool

Enterprise Manager. Version 6.2. Administrator s Guide

Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center

P4000 SAN/iQ software upgrade user guide

ESET NOD32 Antivirus 4 for Linux Desktop. Quick Start Guide

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

AX4 5 Series Software Overview

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client.

Clearswift SECURE Exchange Gateway Installation & Setup Guide. Version 1.0

Wavecrest Certificate

High Availability for Internet Information Server Using Double-Take 4.x

How to Restore a Windows System to Bare Metal

Setup for Failover Clustering and Microsoft Cluster Service

Installing and Configuring vcenter Multi-Hypervisor Manager

Installing a Browser Security Certificate for PowerChute Business Edition Agent

Infor Xtreme Browser References

Installing the Microsoft Network Driver Interface

Dell High Availability Solutions Guide for Microsoft Hyper-V

Actualtests.C questions

Banner Frequently Asked Questions (FAQs)

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

NovaBACKUP xsp Version 12.2 Upgrade Guide

Dell OpenManage Mobile Version 1.4 User s Guide (Android)

FactoryTalk View Site Edition V5.0 (CPR9) Server Redundancy Guidelines

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

Third Party System Management Integration Solution

Sophos UTM. Remote Access via SSL Configuring Remote Client

CM500 High Speed Cable Modem User Manual

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. August 2014 Phone: Publication: , Rev. C

Reconfiguration of VMware vcenter Update Manager

StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

VMware vsphere 5 Quick Start Guide

Parallels Virtuozzo Containers 4.6 for Windows

Drobo How-To Guide. Cloud Storage Using Amazon Storage Gateway with Drobo iscsi SAN

Using DBMoto 7 in a Microsoft Windows Cluster

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Deploying Remote Desktop Connection Broker with High Availability Step-by-Step Guide

Intel Active Management Technology with System Defense Feature Quick Start Guide

Instructions for Configuring Your Browser Settings and Online Security FAQ s. ios8 Settings for iphone and ipad app

Transcription:

Storage Center 6.6 Software Update Guide

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. 2015-03 Rev. A00

Contents About this Guide... 4 Revision History...4 Audience...4 Contacting Dell...4 Related Publications...4 Storage Center Documents... 4 1 Getting Started... 6 Updating Storage Center Software...6 Minimum Configuration...6 Requirements for System Manager... 6 Validate Host Best Practices...7 Types of Components...7 Checking Update Status...8 Update Status Messages...9 Update Status Actions... 10 Viewing Update Package Details...11 Decide How to Apply Updates...12 Downloading an Available Update...13 Adding or Upgrading Enclosures... 13 2 Installing an Update... 14 Prepare for the Update...14 Send Data Using SupportAssist... 14 Validate Components...14 Installing the Update...15 Completing the Update...16 Reconnect to the Storage Center...16 Rebalance Ports on Dual-Controller Storage Centers... 16 Enable System Cache... 17 Check for Additional Updates... 17 Send Data Using SupportAssist... 17 Get a System Check...17 3

About this Guide This guide describes the contents of the Storage Center update packages and provides the instructions needed to update the Storage Center software and firmware. Revision History Document Number: 22W85 Revision Date Description A00 March 2015 Initial release in support of version 6.6 Audience Storage administrators responsible for updating Storage Center software are the target audience for this guide. The intended reader has a working knowledge of storage and networking concepts. Contacting Dell Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues go to www.dell.com/support. For customized support, enter your system Service Tag on the support page and click Submit. For general support, browse the product list on the support page and select your product. Related Publications The following documentation is available for Dell storage components managed using System Manager. Storage Center Documents Storage Center Release Notes Contains information about features and open and resolved issues for a particular product version. Storage Center Deployment Guide Provides cabling instructions for Storage Center controllers, switches, and enclosures and provides instructions for configuring a new Dell Storage Center using the System Manager Startup wizard. Storage Center System Manager Administrator s Guide Describes the Storage Center System Manager software that manages an individual Storage Center. Storage Center Software Update Guide Describes how to upgrade Storage Center software from an earlier version to the current version. Storage Center Maintenance CD Instructions Describes how to install Storage Center software on Storage Center controllers. Installing Storage Center software using the Storage Center Maintenance CD is intended for use only by sites that 4 About this Guide

cannot update Storage Center using the standard update options available through the Storage Center System Manager. Storage Center Command Utility Reference Guide Provides instructions for using the Storage Center Command Utility. The Command Utility provides a command-line interface (CLI) to enable management of Storage Center functionality on Windows, Linux, Solaris, and AIX platforms. Storage Center Command Set for Windows PowerShell Provides instructions for getting started with Windows PowerShell cmdlets and scripting objects that interact with the Storage Center via the PowerShell interactive shell, scripts, and PowerShell hosting applications. Help for individual cmdlets is available online. About this Guide 5

Getting Started 1 This section of the Software Update Guide provides information about the contents of Storage Center update packages and how to prepare for installing updates. Updating Storage Center Software Storage Center updates are bundled together as a single downloadable update package. An update package includes the latest updates for the following Storage Center software and firmware: Storage Center System Manager software Storage Center firmware Enclosure firmware Disk firmware NOTE: When performing an update of both the Storage Center operating system and the Enterprise Manager software, update the Enterprise Manager software before updating the Storage Center operating system. Minimum Configuration Before you install the update package, ensure that Storage Center meets the minimum hardware and software requirements. Hardware: Only SC040, SC4020, and SC8000 controllers can run Storage Center version 6.6. Software: The current version of Storage Center on the controller must be 6.5 or later to update to Storage Center version 6.6. Requirements for System Manager Storage Center System Manager is a Java applet that requires the use of a Java plugin to run. The following table provides the minimum software requirements for running System Manager. Table 1. System Manager Requirements Component Requirements Web browser Windows Internet Explorer versions 7, 8, 9, and 11 Windows Internet Explorer Desktop version 10 (Internet Explorer Modern version 10 is not supported) Mozilla Firefox on Microsoft Windows Google Chrome on Microsoft Windows 6 Getting Started

Component Requirements NOTE: Other web browsers may work but are not officially supported. Java Java version 7 and 8. When using Java, open the Java Control Panel and make sure that the option Enable Java content in the browser is selected. Validate Host Best Practices To reduce the impact of the controller restart operation on the host operating system and applications when applying Service Optional updates, verify that the correct configuration and best practices are applied to the host. NOTE: Dell recommends that each host has at least one failover test where the redundancy of the HBAs, fabrics, and storage controllers is tested and validated. Validate every newly configured host that is accessing Storage Center volumes or when large update packages are applied to the host operating system. See the Storage Center System Manager Administrator s Guide for more information about HBA server settings and iscsi settings best practices. Types of Components Within an update package, an individual update component is classified according to how it can be installed. NOTE: The method you use to install updates affects your infrastructure differently. Before applying updates, understand the impact of the update on Storage Center infrastructure and plan the update process carefully to avoid unplanned downtime. Required: Required components must be installed as part of the update. Deferrable: Deferrable components can be installed later; however, doing so can negatively affect the reliability of the components whose firmware is not being updated. Service Affecting: Service Affecting components can be installed only when Storage Center is temporarily taken out-of-service. During the outage, all systems and services using volumes from Storage Center must be powered down correctly to avoid data loss and unplanned system disruption. Service Optional: Service Optional components can be installed either when Storage Center is in service or during a scheduled outage. Although these components are designed to not cause system disruption, the way in which Storage Center is configured can affect performance. During a Service Optional update, the firmware update process occurs as a rolling controller update. This process results in a controller failover event that causes the host initiators to log out and then log back in to the volumes connected to the SAN. If you have implemented the Dell Storage best practices for host settings (for example, multipath IO, HBA settings, time-outs) and fabric design (cabling, number of front-end ports, and so on), the logout/login process has minimal effect on host volumes. The update process should not affect data access, data integrity, or result in any data loss. NOTE: When performing a Service Optional update, reduce the impact of the controller restart operation on the host OS and applications by verifying that the correct configuration and best practices are applied to each newly configured host. Dell recommends that every host that accesses Storage Center volumes or that has large updates applied to its OS, has at least one failover test. The following table shows which components affect service during installation. Getting Started 7

Table 2. Storage Center with a Single Controller Storage Center Firmware Update Enclosure Firmware Update. Depending on the components for a specific release, enclosure firmware may or may not be Service Optional. Disk Firmware Update. Disk firmware upgrades may be service affecting or nonservice affecting depending on the drive. A drive that supports an in-service upgrade, is a drive that can: Process IOs and other commands while receiving firmware blocks. Boot and ready new firmware in three seconds. Service Affecting Service Optional Table 3. Storage Center with Dual Controllers Storage Center Firmware Update Enclosure Firmware Update. Depending on the components for a specific release, enclosure firmware may or may not be Service Optional. Disk Firmware Update. Disk firmware upgrades may be service affecting or nonservice affecting depending on the drive. A drive that supports an in-service upgrade, is a drive that can: Process IOs and other commands while receiving firmware blocks. Boot and ready new firmware in three seconds. Service Affecting Service Optional NOTE: For a Storage Center disk firmware update, Service Affecting only applies to Storage Center version 5.5.12 or earlier. Checking Update Status The Update Status wizard compares your Storage Center software version to the latest version available from Dell, and then provides options to proceed. NOTE: Dell SupportAssist must be enabled to use the Update Status wizard. 1. From the Storage Management menu, select System Update Update Status. The Update Status wizard starts. 8 Getting Started

Figure 1. Update Status Wizard The Update Status page displays the current update status and whether the updates are service affecting and provides update options and details. 2. Select the appropriate option for your installation. NOTE: When checking for updates for the first time on an SC8000 running Storage Center 6.1.1 and the Update Status is No Update Available, contact Dell Technical Support Services. Update Status Messages When the Update Status wizard starts, the initial page displays Storage Center status messages. Table 4. Update Status Messages Field Current Update Status Description Status of the Check Update, Download Update, or Install Update process: Checking for Update: Storage Center is checking for updates. Controller Down: A controller is down. Installation cannot proceed when a controller is down. Downloading Update: Storage Center is downloading an update. Error Checking or Downloading: An error occurred during Check Update or Download Update. Getting Started 9

Field Current Package Version New Package Version Service Affecting Controller Reset Last Check Time Validation Errors Installation Errors Description Error Installing Update: An error occurred while installing an update component. Click Install Report to view details on the installation error. Installing Update: Storage Center is installing an update. No Updates Available: Last Check Update process found no available updates. Click Check Now to check again for updates. Update Available for Download: An update is available for download. Click Download Now to download the update. Update Ready to Install: A downloaded update is ready to install. Click Install Update to install the update. Validating Components: Storage Center is verifying each component status to determine if a component is ready for installation. OS version currently running on the Storage Center. Version of the OS ready to download or install. Indicates whether package installation affects Storage Center service: : Package installation affects Storage Center service. No: Package installation does not affect Storage Center service. Deferrable: Package contains service-affecting components that can be installed later. Indicates whether the update package installation requires rebooting the controllers: Single-controller Storage Center: Rebooting the controller always affects service. Clustered-controller Storage Center: If the upgrade is service affecting, the controllers are rebooted simultaneously. If the upgrade is not service affecting, the controllers are rebooted in sequence. Shows the date and time when Storage Center last successfully checked for updates. Shows the number of validation warnings or errors, if any, encountered during a validate update process. Shows the number of installation errors and warnings, if any, that occurred during installation. Update Status Actions The Update Status wizard available options depend on the reported status. Table 5. Update Status Wizard Actions Option Check Now Validate Components Install Update Details Description Check for updates. Validate update components. Install the downloaded update package. View details for a downloaded update package. 10 Getting Started

Viewing Update Package Details When a downloaded update package is ready to install, you can view details for the package before installing it. 1. From the Storage Management menu, select System Update Update Status. The Update Status wizard starts. 2. Click Details. The Update Details page appears. This page provides details for all components included in the update package. Figure 2. Update Details Page Table 6. Update Package Details Column Component Type Version Status Update Count Update Type Description Name of component to update. Type of component to update: Storage Center: Updates Storage Center software. Enclosure: Updates enclosure firmware. Disk: Updates disk firmware. Version number of the update component. Status of the component update: Ready for Update: Component is ready for update. Installed: Component has been installed. Number of components on the Storage Center to which the update component applies. For example, for a controller firmware update, the count is 1 for a single-controller Storage Center and 2 for a dual-controller Storage Center. Indicates whether the installation of the update component is required or deferrable: Required: Update must be applied. For a single-controller Storage Center, the update component affects service. Getting Started 11

Column Description For a dual-controller Storage Center, the update component can be performed without disruption of service. Deferrable Service Affecting: Update is deferrable and applying the update affects service on all systems. Schedule a service outage to apply the update. Deferrable Service Optional: Update is deferrable and applying the update can be done either without affecting service or during a scheduled service outage. Message Shows informational messages, if any, that further describe the update component. Decide How to Apply Updates Within an update package, an individual update component is classified by how the update component can be installed. The installation process automatically reboots Storage Center controller(s) when required by the components being updated. Disk firmware, when applied in-service, does not require a system boot. For dual-controller Storage Centers, installation reboots the controllers in sequence or simultaneously, depending on the components being updated. A service outage is required when controllers are rebooted simultaneously. NOTE: Do not manually restart the Storage Center controllers during the update process. Updating is a software-controlled process. 1. After downloading an update package, view the Update Details to determine how the update affects service. a. From the Storage Management menu, select System Update Update Status. The Update Status wizard starts. b. Click Details. The Update Details page appears. 2. On the Update Details page, view the Update Type column for each component. Table 7. Software Update Types Update Type Required Deferrable Service Affecting Deferrable Service Optional Description Component must be installed. For a single-controller Storage Center, the update component affects service. For a dual-controller Storage Center, the update component can be performed without disruption of service. Component installation can be deferred. Applying the update affects service on all Storage Centers. Schedule a service outage to apply the update. Component installation can be deferred. Applying the update can be done either without 12 Getting Started

Update Type Description affecting service or during a scheduled service outage. 3. After viewing the Update Type for all components included in the update package, determine how to apply the updates: If you intend to install components that affect service, plan for and schedule a service outage during which to apply the updates. You may also want to install components that are service optional during the schedule outage. If you intend to install components that do not affect service, plan for applying the updates during a time at which the Storage Center is least busy. NOTE: If you do not install deferrable components when you install the required components, it can negatively impact the reliability of the components whose firmware is not being updated. Dell recommends that you schedule a service outage and apply deferrable component updates as soon as possible. Downloading an Available Update Storage Center can be configured to automatically download updates; otherwise, updates must be downloaded manually. 1. From the Storage Management menu, select System Update Update Status. The Update Status wizard starts and checks for available updates. When complete, if an update is available you can download it for installation. 2. Click Download Now. As Storage Center downloads the update, the status appears in the Update Status main page. When Storage Center is finished downloading updates, results are displayed in the Update Status main page. 3. After downloading an update package, review the Update Details page to determine how the update affects service. Adding or Upgrading Enclosures If you are adding or upgrading enclosures, check the update status and install software updates before discovering the new or changed enclosures in System Manager. 1. Check update status. 2. Install updates as needed. 3. Cable the enclosure. For more information, see the storage controller Deployment Guide or the Connectivity Guide. 4. Use Storage Center System Manager to scan for new disks. For more information, see the Storage Center System Manager Administrator s Guide. NOTE: Storage Center does not automatically detect new disks or enclosures. You must use System Manager to manually scan for new disks. Related Links Checking Update Status Installing the Update Getting Started 13

Installing an Update 2 This section of the Software Update Guide provides instructions for installing Storage Center update packages and performing the tasks required to finalize the update process. The Storage Center update process runs without intervention. When the software update finishes, some final tasks are required to complete the update. Prepare for the Update Before installing update components to the Storage Center, follow these procedures to prepare the Storage Center for the update. 1. Enable Dell SupportAssist and use it to send diagnostic data to Dell Technical Support Services. 2. Contact Dell Technical Support Services to get a preupdate system check. 3. Back up the system. Verify that backups are up-to-date and replications are synchronized. 4. Validate the update components before installing an update. NOTE: When updating both the Enterprise Manager software and the Storage Center operating system, update Enterprise Manager before updating Storage Center. Send Data Using SupportAssist Use Dell SupportAssist to send diagnostic data about Storage Center to Dell Technical Support Services. NOTE: Dell SupportAssist must be enabled to use the SupportAssist wizard. For instructions, see the Dell Storage Center System Manager Administrator s Guide. 1. From the Storage Management menu, select System SupportAssist SupportAssist. The SupportAssist wizard starts. 2. Click Send SupportAssist Data Now. The SupportAssist In Progress dialog box appears. 3. When the dialog box displays the message SupportAssist Started, click OK. 4. When the system reports success for all SupportAssist transfers, click Close to exit the SupportAssist wizard. Validate Components Validate the update components before installing an update. 1. From the Storage Management menu, select System Update Update Ready to Install Install Now. 2. Click Validate Components. If Storage Center detects a problem when validating update components, the Validate Components page displays a summary of validation problems. To revalidate an update package, when validation results are displayed, click Revalidate Components. 14 Installing an Update

Storage Center re-validates the update components and returns the results. Validation problems are classified as warnings or errors. In general: Validation warnings indicate a connection or cabling issue with a component that prevents the component from being updated. Validation errors indicate that a file required by an update component cannot be found. When a validation warning or error is displayed, resolve the issue before continuing with the installation. NOTE: If validation warnings and/or errors cannot be resolved, contact Dell Technical Support Services for assistance in resolving the errors. Do not force an installation without assistance. Installing the Update After the system reports that all installation components have been successfully validated, install the update. The installation process automatically reboots Storage Center controller(s) when required by the components being updated. NOTE: Do not manually reboot the Storage Center controllers during the update process. Updating is a software-controlled process. Disk firmware, when applied in-service, does not require a system reboot. For a dual-controller Storage Center, the installation process reboots the controllers in sequence or simultaneously, depending on the components being updated. A service outage is required when controllers are rebooted simultaneously. 1. Before updating Storage Center software, clear the Java cache in the Java Control Panel. 2. Click Install Update. Update package components are validated. 3. When complete, click Continue. 4. Select the updates you want to apply to the Storage Center: Apply the required portion of the update package: Applies only the required portion of the update package. Apply updates that will not affect service: Applies the required portion of the update package and all components that are Service Optional (components that can be installed in-service). Apply updates that will disrupt service (exclude Service Optional): Applies the required portion of the update package and all components that are Service Affecting (components that cannot be installed in-service). Apply all updates: Applies all updates in the update package, including all deferrable updates, Service Affecting components, and Service Optional components, When applying all updates, you should be aware of the following: A service outage is taken, regardless of components. Disk firmware is updated across all disks in parallel during the service outage. NOTE: Depending on the updates, the estimated completion time for Service Optional enclosure updates may be significantly shorter using the Apply all updates option as compared to the Apply updates that will not disrupt service option. 5. After you have selected the manner in which to apply updates, view information for the update you have selected: Service Affecting: Displays whether the installation of the selected components affects service. Controller Reset: Displays whether the installation causes a controller reboot. Installing an Update 15

Estimated Completion Time: Time estimate for the installation. 6. Click Continue. A summary of the selected installation options appears. NOTE: The installation process automatically reboots the Storage Center. Do not click Install Now until you are ready to reboot the Storage Center. 7. Depending on whether the installation affects service or not, do one of the following: For an installation that does not affect service: The Install Update page displays the message, Non-Service Affecting Install Confirmation. Click Install Now. For an installation that affects service: a. Read the summary screen messages, and click Continue. b. Halt all IO to the Storage Center. The best way to ensure that IO is stopped is to shut down servers connected to the Storage Center. c. Click Install Now. 8. After successfully installing the update, reconnect to the Storage Center and validate the installation. Completing the Update After successfully applying update components to the Storage Center, follow the steps in this procedure to finish the update process. Reconnect to the Storage Center After installing the updates, reconnect to the Storage Center. If the browser was left running during the update, at the end of the update, the browser may report a loss of connection. Refresh the browser to reconnect to the Storage Center. If the browser was closed during the update, open a browser and enter the name or IP address of the Storage Center. Rebalance Ports on Dual-Controller Storage Centers For dual-controller Storage Centers, rebalance ports. 1. Click on the Controllers icon to view controller status. 2. When both controllers are up, the local port condition may be unbalanced. If so, click Rebalance Ports. The system rebalances the ports. 3. Verify that both controllers are running the new version of code. From the Help menu, select About Compellent Storage Center. A dialog box appears displaying the Storage Center version for each controller. 16 Installing an Update

Enable System Cache When the update is complete and the system is rebooted, enable read and write cache. NOTE: Cache settings for individual volumes override global cache settings. To enable caching for some volumes and not others, enable caching system-wide and then disable caching for individual volumes. 1. From the Storage Management menu, select Properties System. 2. Click the Cache tab. 3. Select Enable Read Cache and/or Enable Write Cache. 4. Click OK. Check for Additional Updates After the update is complete, check for Storage Center updates that may have become available after the Storage Center release. 1. From the Storage Management menu, select System Update Update Status. 2. Click Check Now. As Storage Center checks for updates, status appears in the Update Status wizard. 3. If an update is available, follow the installation instructions. If the software update process is complete, use SupportAssist to send diagnostic data to Dell Technical Support Services. Related Links Installing the Update Send Data Using SupportAssist Use Dell SupportAssist to send diagnostic data about Storage Center to Dell Technical Support Services. NOTE: Dell SupportAssist must be enabled to use the SupportAssist wizard. For instructions, see the Dell Storage Center System Manager Administrator s Guide. 1. From the Storage Management menu, select System SupportAssist SupportAssist. The SupportAssist wizard starts. 2. Click Send SupportAssist Data Now. The SupportAssist In Progress dialog box appears. 3. When the dialog box displays the message SupportAssist Started, click OK. 4. When the system reports success for all SupportAssist transfers, click Close to exit the SupportAssist wizard. Get a System Check Contact Dell Technical Support Services for a post-update system check. Installing an Update 17