On-Line Monitoring and Process Analytical Technologies

Similar documents
Multivariate Chemometric and Statistic Software Role in Process Analytical Technology

Industrial Process Monitoring Requires Rugged AOTF Tools

Raman spectroscopy Lecture

INFRARED SPECTROSCOPY (IR)

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Raman Spectroscopy. 1. Introduction. 2. More on Raman Scattering. " scattered. " incident

Back to Basics Fundamentals of Polymer Analysis

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Multivariate Tools for Modern Pharmaceutical Control FDA Perspective

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Asian Journal of Food and Agro-Industry ISSN Available online at

Time out states and transitions

Guideline on Process Validation

FTIR Instrumentation

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Introduction to Fourier Transform Infrared Spectrometry

Quality by Design Approaches to Analytical Methods -- FDA Perspective. Yubing Tang, Ph.D. FDA/CDER/ONDQA AAPS, Washington DC October 25, 2011

Infrared Spectroscopy 紅 外 線 光 譜 儀

Ultraviolet Spectroscopy

ICH guideline Q8, Q9 and Q10 - questions and answers volume 4

Pharmaceutical Quality Systems: US Perspective

5.33 Lecture Notes: Introduction to Spectroscopy

Symmetric Stretch: allows molecule to move through space

Infrared Spectroscopy: Theory

Organic Spectroscopy

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

In this column installment, we present results of tablet. Raman Microscopy for Detecting Counterfeit Drugs A Study of the Tablets Versus the Packaging

m/z

Raman Spectroscopy Basics

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

Experiment #5: Qualitative Absorption Spectroscopy

Electromagnetic Radiation (EMR) and Remote Sensing

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Workshop B Control Strategy

Applications of Near Infrared Spectroscopic Analysis in the Food Industry and. Research

Extended abstract: Model-based computer-aided framework for design of process monitoring and analysis systems

FDA Guidance for Industry Update - Process Validation

Spectral Measurement Solutions for Industry and Research

Risk-Based Validation of Computer Systems Used In FDA-Regulated Activities

Chemistry Instrumental Analysis Lecture 1. Chem 4631

PROPOSAL FOR REVISION OF THE SUPPLEMENTARY GUIDELINES ON GOOD MANUFACTURING PRACTICES: VALIDATION, APPENDIX 7: NON-STERILE PROCESS VALIDATION

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Preface Light Microscopy X-ray Diffraction Methods

2. Molecular stucture/basic

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

In Situ Spectroscopy. Reaction Analysis and PAT Tools From Research to Manufacturing

h e l p s y o u C O N T R O L

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

Signal to Noise Instrumental Excel Assignment

Guidance for Industry

Molecular Spectroscopy

13C NMR Spectroscopy

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Using the Spectrophotometer

INSPIRE GK12 Lesson Plan. The Chemistry of Climate Change Length of Lesson

NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.

Section 6 Raman Scattering (lecture 10)

Engineering Standards Advance PAT

Edited by. C'unter. and David S. Moore. Gauglitz. Handbook of Spectroscopy. Second, Enlarged Edition. Volume 4. WlLEY-VCH. VerlagCmbH & Co.

Implementing New USP Chapters for Analytical Method Validation

LabRAM HR. Research Raman Made Easy! Raman Spectroscopy Systems. Spectroscopy Suite. Powered by:

Aligning Quality Management Processes to Compliance Goals

DNA Detection. Chapter 13

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Potential use of handheld Raman devices as tools for screening medicines for quality

Pesticide Analysis by Mass Spectrometry

Trans Fats. What is a trans fat? Trans fatty acids, or trans fats as they are known, are certain

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Organic Chemistry Tenth Edition

GIANT FREQUENCY SHIFT OF INTRAMOLECULAR VIBRATION BAND IN THE RAMAN SPECTRA OF WATER ON THE SILVER SURFACE. M.E. Kompan

ANALYTICAL OUTSOURCING WHY SHOULD YOU OUTSOURCE?

Determination of Molecular Structure by MOLECULAR SPECTROSCOPY

Guidance for Industry. Q10 Pharmaceutical Quality System

Annex 7 Application of Hazard Analysis and Critical Control Point (HACCP) methodology to pharmaceuticals

Raman Scattering Theory David W. Hahn Department of Mechanical and Aerospace Engineering University of Florida

Raman vs. FTIR Process Analyzers for In-Line Blending Use

MISCIBILITY AND INTERACTIONS IN CHITOSAN AND POLYACRYLAMIDE MIXTURES

An FDA Perspective on Post- Approval Change Management for PAT and RTRT

Guidance for Industry

Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis

Annex 7 Guidelines on pre-approval inspections

Transforming CliniCal Trials: The ability to aggregate and Visualize Data Efficiently to make impactful Decisions

Application Note AN4

OPTICAL DETECTION OF KCl VAPOR AND ATOMIC K RELEASES FROM BIOMASS FUELS COMBUSTED IN SINGLE PARTICLE REACTOR

Contents. Contributors. 1 Quality control and regulation 1 C.J. MOORES

A LEVEL. Type of resource H433 CHEMISTRY B. Theme: Carbon-13 MMR. October 2015

2 Spectrophotometry and the Analysis of Riboflavin

Photoinduced volume change in chalcogenide glasses

PAT Initiative Expected to Invigorate Pharmaceutical Industry with Improved Quality, Better Efficiency and Improved Profits.

Revision of The Dissolution Procedure: Development and Validation 1092

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Introduction to Data Acquisition

Measurement & Analytics Measurement made easy. MB3600-CH10 FT-NIR oleochemicals analyzer Pre-calibrated for Iodine Value (IV) and %Trans Fat

White paper: FDA Guidance for Industry Update Process Validation

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Transcription:

September 9, 2003 On-Line Monitoring and Process Analytical Technologies Purpose Process analytical technologies (PAT) are systems which provide continuous on-line monitoring of critical quality parameters and performance attributes of raw and in-process materials. Application of PATs to pharmaceutical manufacturing is an element of FDA s new risk-based approach to regulation described in GMP s for the 21 st Century, Reference (1). In terms of technologies, implementation of PATs involves the application of analytical chemistry, sensors, feedback process control, and information management. On a more fundamental level, implementation of PATs requires a scientific understanding of the manufacturing process and the effects of the process on the physiochemical characteristics of the product. FDA believes that the enhanced process knowledge required to implement PATs will leading to better product quality, and industry proponents expect use of PATs will improve production efficiency and reduce manufacturing costs. Recently, FDA has released draft guidance that discusses their expectations regarding the implementation of PAT. This guidance is contained in Reference (2). A fundamental element of FDA s thinking as described in the draft guideline is that use of PAT will drive more quality to be built in to the design of drug products. This document provides a brief overview of the approach being used to examine and implement PATs in the industry and discusses the roles that MPR can play in this effort. Summary of PAT Initiative Historically, pharmaceutical production involves the manufacture of the finished product followed by off-line verification of product quality. An example, of the current approach to manufacturing is illustrated in Figure 1. Manufacturing is performed in unit operations which are monitored and controlled using parameters that are straightforward to measure but that may provide only indirect indication of the product physical and chemical properties. In many cases, unit operations are controlled simply by time (e.g., a mixing operation may be specified to be performed at a certain speed and temperature for a certain period of time). At specified points in the process, quality control chemists remove samples of drug, take samples to a lab for testing, and only look for the active ingredient or ingredients in a mixture of active

drugs and inactive ingredients. Out-of-specification results lead to an investigation which may or may not identify the root cause of the failure. Since process understanding is often limited to empirical observations of the effect of process parameters on product quality, the effectiveness of process controls is limited. Figure 1. Traditional Manufacturing Approach Although the current level of product quality is adequate for the intended use, the disadvantages with this approach are recurring manufacturing difficulties, the possibility of failed drug batches (often in excess of 10%), and the need for continuous process optimization. To remedy this suboptimal condition, pharmaceutical companies are examining PATs for on-line process monitoring. The improved control gained from PAT is expected to provide benefits such as better batch-to-batch consistency, better quality due to fewer impurities, improved process understanding, faster response times, increased productivity, and lower costs. The central objective of PAT is to generate product quality information in real-time. While process monitoring traditionally involves measuring temperature, pressure, flows, ph, and other physical parameters, PAT focuses on the use on on-line testing using infrared spectrometry, Raman spectrography, and other physiochemical techniques as a primary means of process monitoring. 1 A computer system retrieves and analyzes data in real-time to provide information on the properties of blends and other characteristics of the manufacturing process. Computer simulation of the process can be used with these data to predict product characteristics, allowing process parameters to be adjusted in order to achieve the optimal results. Monitoring these aspects of manufacturing is expected to ensure that the desired endpoint conditions such as uniformity, drying, and mixing can be pinpointed to a high degree of certainty. Figure 2 shows 1 See the Appendix to this article for a brief description of several non-contact chemical analysis technologies. 2

one concept of how the PAT approach could be implemented in a manufacturing process in contrast to the approach illustrated in Figure 1. Figure 2. Manufacturing Approach with PAT With increased knowledge of the manufacturing process and use of PATs for on-line monitoring, final product characteristics, such as dissolution rate, would be under such high control that the results could be accurately predicted well before the product is analyzed. In addition, because quality control using PAT is based on real-time electronic data rather than paper documentation, multiple individuals such as the manufacturing supervisor and the quality assurance manager could be simultaneously notified of any product quality problems. In order to properly implement PAT, research on the correlation between end-test results and measured process parameters is needed so that the impact of the process, raw materials, and finished product variables is understood. Currently, many processes which are neither fully understood nor capable at commercial scales are transferred from the R&D to manufacturing. Lengthy and elaborate new product introduction exercises generate data but fall short of providing critical information which correlates end-test results with measured process parameters. Traditionally, 50% of production costs are locked in before Phase III begins, so many process inefficiencies are institutionalized. Therefore, the most significant advantages of PAT will be gained by moving toward complete process understanding, which is attained during process development. In turn, complete process understanding offers the opportunity for quality by design manufacturing methods. 3

Enabling Technologies Design and implementation of a PAT system requires knowledge from several different fields of expertise, including pharmaceutical manufacturing processes, sensors and data acquisition, and analysis tools. This section briefly describes how these fields relate to PAT. Pharmaceutical Process Development Experience with pharmaceutical manufacturing processes is necessary to properly implement PAT. Often in existing pharmaceutical processes, parameters used to control the process are those that are easy to measure, but may not necessarily include those that are most representative of product quality. Actual product quality is usually a function of many interdependent variables. A critical part of a PAT initiative is to analyze the process to identify the true process critical parameters. This requires a greater investment in process development including more substantial experimentation and analysis of results. In order to truly understand the inter-relationships of the many variables that can affect a product, design of experiments techniques are needed for rigorous analysis of the process. Sensors and Data Acquisition Once the true process critical parameters have been identified, the appropriate sensor and data acquisition technologies are applied to measure and trend these parameters in real-time. PAT takes advantage of the latest advances in sensor technology, including chemometric methods such as Near Infrared (NIR) spectroscopy, and state-of-the-art computing. Data Management and Analysis A primary objective of PAT is to promote a deeper, firstprinciples understanding of the process to improve product yield and quality. One of the benefits of recent computer technology advances is the ability to collect, store, and analyze large amounts of data. Understanding and interpreting the data is in most cases crucial to process knowledge and control. Expertise in the state-of-the art of tools for data retrieval, processing, and analysis can lead to cost-saving process improvements. High-performance trending, regression, and pattern recognition algorithms, as well as the integration of these tools into multifunction and user-friendly software and human-machine interfaces (HMIs) will enhance process knowledge. MPR s PAT Services MPR possesses expertise that helps companies implement PAT-based systems in a variety of ways. Descriptions of a few of MPR s services are below. Process Development MPR analyzes pharmaceutical manufacturing processes to determine whether the process could be improved using PAT. MPR identifies proven technologies that would enable the tracking and understanding of true process critical parameters, and ultimately the improvement of process efficiency. Sensor Design, Development, and Testing MPR has been closely involved with the design and implementation of a variety of highly specialized sensors for the pharmaceutical industry and other technology-based industries including national defense, nuclear power, and environmental remediation. These sensors include traditional sensors such as thermocouples and pressure transducers, and more advanced instruments such as acoustic measurement and fiber optic 4

sensors. MPR has designed and implemented many mission critical data acquisition systems, using either commercial or custom-designed hardware. Process Modeling and Simulation MPR has extensive experience with modeling physical systems using a first-principles approach. Combined with proven skill in both pharmaceutical processes and software development, MPR s can quickly identify and analyze the critical parameters of a process, and automate the analysis for real-time evaluation. PAT Implementation MPR helps pharmaceutical companies with existing processes and specific PAT needs to select sensors and data acquisition equipment. We develop protocols for trial evaluation of PAT systems and provide statistical analysis of the data collected. MPR also installs the hardware and develops software to analyze the data in real-time. Root-Cause Investigation If an existing process is generating poor yields, and conventional techniques are unable to identify or resolve the problem, MPR provides PAT solutions. MPR can examine the troubled process and identify PAT techniques that could provide improvements. As needed, MPR can perform multivariate data analyses and deliver recommendations for adjustment of the equipment or process parameters. References 1. US Food and Drug Administration, Pharmaceutical cgmps for the 21st Century: A Risk-Based Approach; A Science and Risk-Based Approach to Product Quality Regulation Incorporating an Integrated Quality Systems Approach, Concept Paper, August 21, 2002. 2. US Food and Drug Administration, Guidance for Industry, PAT A Framework for Innovative Pharmaceutical Manufacturing and Quality Assurance, Draft, August 2003. 5

Appendix Chemical Analysis Technologies Currently, there are several methods for rapid, non-contact chemical analysis, and several of the more widely used technologies are summarized below. Each of the methods has its own advantages, disadvantages, and best application areas. UV (Ultra-Violet) /visible spectrophotometry, the most commonly used traditional spectroscopy tool, recognizes a chemical by measuring the absorption spectrum after transmitting UV or visible light through a solution or a thin film. It requires sample preparation for the transmission measurement, which is a drawback for in-situ measurement. FT-IR (Fourier Transform Infra-Red) spectroscopy uses either the transmitted or reflected infrared light spectrum generated by an IR source. When the frequency of the incident IR light matches the molecular vibration of a diatomic molecule (such as O-H, N-H, or C=O), absorption of the IR light is detected. The measured absorption frequencies from a sample can therefore be correlated with its chemical composition. Like UV/VIS spectroscopy, a fluorescence spectrophotometer shines monochromatic light on a sample. While a UV/VIS spectrometer relies on absorption spectra after transmission of light through a sample, a fluorescence spectrophotometer picks up emission spectra that result from atomic excitation of the sample. For UV/VIS spectroscopy, a sample should be transparent, however for fluorescence spectroscopy, it does not have to be, making it more suitable for PAT applications. The Raman effect is a fundamental process in which energy is exchanged between light and matter. When light impinges on a substance it can be scattered or absorbed. Most of the scattered light will have the same frequency as that of the incident light. However, a small fraction of the incident light can go into setting molecules in the material into vibration. The energy for this excitation comes from the incident light. The frequency change of this scattered light must equal the vibrational frequency of the excited molecules. This process of energy exchange between excited molecules and incident light is known as the Raman effect. The process of Raman scattering can be viewed as the transition of a molecule from its ground energy state to an excited vibrational state, accompanied by the simultaneous absorption of an incident photon and emission of a Raman scattered photon. The Raman scattered light can be collected by a spectrometer and displayed as a spectrum, in which its intensity is displayed as a function of its frequency change. Since each molecular species has its own unique set of molecular vibrations, the Raman spectrum of a particular species will consist of a series of peaks or bands. 6

About the Authors This paper was prepared by Eric Claude and Chris Rice of MPR Associates, Inc. For more information about this paper or MPR Associates, please contact: Eric Claude Phone: 703-519-0535 Email: eclaude@mpr.com The address at our Alexandria headquarters is: MPR Associates, Inc. 320 King Street Alexandria, VA 22314 Phone: 703-519-0200 Fax: 703-519-0224 MPR Associates is an engineering and consulting firm founded in 1964 and headquartered in Alexandria, Virginia. MPR provides technology development solutions for life science firms, with a focus on product design (instruments, delivery systems, devices), manufacturing process development, training, and validation. Key expertise is available in process engineering, mechanical design, materials science, electronics, controls, software, and GMP compliance. Please also refer to the Technology section of our web site at www.mpr.com for additional information. 7