Instruction manual Temperature regulator SM6S Operating instructions Temperature regulator SM6S

Similar documents
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

PD 100A. Printing data system

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

Modular I/O System Analog and Digital Interface Modules

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Infrarot-Bewegungsmelder IP44

Digital Pressure Measuring Instrument MDR480

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Duct Humidity Transmitter

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Inwall Room Temperature Unit

Safety technique. Emergency stop module BO 5988 safemaster

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

TC-9102 Series Surface Mount Temperature Controllers

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

Manual. Solar Fountain Mobile Phone Charger

ACS-30-EU-EMDR-10-MOD

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User s Manual Before using the inverter, you need to read and save the safety instructions.

CQM1-SF200/CS1W-SF200

MOUNTING AND OPERATING INSTRUCTIONS

Givare NC-SRS 280 och 880

38 Series - Relay interface modules A

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

User Manual Auto Tuning PID Temperature Controller

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

PSC-A5 Solar Charge Controller Manual

J TB/TW Temperature limiter, temperature monitor

How To Read A Pipe From A Sensor

GSM HOME SECURITY SYSTEM

Quick Connect. quick - simple - efficient.

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

38 Series - Relay interface modules A

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Panel Meters and Controllers Modular Panel Meter Type EDM 35

650W Single Output Power Supply

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Combi B Alarm box. Mounting instructions

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Original instructions Tina 3A/Aps Adaptor unit

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

TT 49 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

Operating Instructions

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

NC-12 Modbus Application

INITIAL SETTING MANUAL

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PIEZOMETER AIRFLOW MEASURING RING

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

max 6f / computer max

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SKR - industry relay

*.ppt 11/2/ :48 PM 1

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Cable Plug acc. to DIN EN , Form A

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Drayton Digistat +2RF/+3RF

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Advantium 2 Plus Alarm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Contents. Document information

WD-AMX Water Detection Controllers

MLC TM Maximum Productivity and Versatility for Control without Compromise!

DALI RC BASIC SO. Control unit Operating instructions

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Electronic Pressure Switch EDS 300

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

HERZ-Thermal Actuators

PRODUCT PROFILE FEATURES

Digital inductive conductivity transmitter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

RM4TG20 three-phase network control relay RM4-T - range V

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Delta Temperature Controller User Manual

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Transcription:

Operating instructions Temperature regulator SM6S SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 1 of 27

Table of contents Contain... Page 2. General plan... 4 3. Description, function and technical data... 4 4. Further functions... 5 5. Safety proceedings in normal use... 5 6. Hazards by electrical energy... 6 7. Mounting notes... 6 8. Switch board cut out... 7 9. Connections... 7 10. Connecting schema... 8 11. Guaranteed values and liability... 9 12. Notes... 9 13. Display and operators control... 11 14. Message by switch-on the regulator... 13 15. Input... 14 15.1 Step 1 Initial setting Mode 14 15.2 Step 2 Main setting mode 16 15.3 Step 4 Lower sublevel 17 15.4 Step 5 Engineering mode 19 15.5 Selection of sensor 23 16. Changing the first and second set value... 24 17. Alarm type (selection)... 25 18. Starting... 26 19. Error alarm on the PV-Reading... 27 20. Cleaning... 27 SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 2 of 27

1. General UNPACKING 1. Indicate visual damages directly to the transporter. 2. Type and notes on the package must agree with the delivery note. 3. Unpack the regulator with the sealed synthetic bag. Open the bag first, when the regulator gets mounted. 4. The type on the unit, the packing and on the delivery note must correspond. 5. Control if there is a fastening bow with the unit. Please inform us by any irregularity. STORING Electric radiation, electrostatically discharge or strong magnetic fields can damage the mounted microprocessor or other electrical parts. STORING CONDITIONS Protect for: Store temperature: Store humidity: possible mechanical damages. humidity Heat and directly insulation. -20 C to +50 C (- 20 F until 120 F). 0-85% relative humidity (avoid condensation!). DIRECTLY USE Please follow all instructions in this manual. Fabrication date The unit identifier is written on the type plate. (side of the covering). The fabrication number is written at the electrical connections. DISCRIPTION OF THE PRODUCT TEMPERATURE-REGULATOR WITH DIGITAL DISPLAY The regulator SM6S contains a control loop with PID-algorithms for Temperature regulation. With this regulator and an adequate temperature sensor it is possible to control a heating or cooling system. The inputs (Sensor) and Alarm types can be adjusted by an intern switch. The adequate Regulator output is fix and must be point out by order. As supply you will find an attachment set for easier mounting of the regulator Additional tool: Ring sealing for IP54 (coming from the switchboard panel) Guide of conformation: Europe: The SM6S is CE checked (EN-61010, EN-50082, EN-55011, EN-55022) EMC SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 3 of 27

2. General plan This description concerns to the 48 x 48 x 167,2 mm regulator type SM6S on microprocessor base. Input Thermo elements: Pt.100 (IEC-751), 3-conductor circuit: E, K, J Specific resistance 100 Ω or less. Sensor break is getting signalized. The Regulator is switching off the regulator output. Maximum specific resistance of 10 Ω per conductor. Sensor break and short circuit are getting signalized, The regulator is switching off the regulator output in both cases. Display accuracy: ± 0.3 % of Scale range ± 1 Digit Temperature compensation: ± 1 C at 25 C ± 10 C (± 1 F at 75 F ± 50 F ) Supply voltage: 100-240 VAC, 50/60 Hz or 24V AC/DC Dimension: 48 x 48 x 167,2 mm ( B x H x T ) Mounting: Front tableau assembly, minimum space to other units - 30 mm Covering: Operation: non-combustible Polycarbonate / Colour: black or grey Front foil 3. Description, function and technical data Actual value ( PV ) Theoretical value ( SV ) Actual value accuracy Sample time 7 Segment red LED, 4-digit 4 x 8 mm 7 Segment green LED, 4-digit 4 x 8 mm Within ± 0,3 % of the scale ± 1 Digit (compensation accuracy ± 1 C to 25 C ± 10 C) (±1 F at 75 F ± 50 F) 250ms PID Characteristic curve Proportional band (P) 0-999 C / 0-99,9 C 0 210 F Integral time (I) 0-999 sec Differential time (D) 0-300 sec Cycle 1-120 sec Factory adjustment Solid State Relay 3 sec Relay 30 sec PD Regulation characteristic Proportional band (P) 0-999 C / 0-99,9 C 0 210 F Differential time (D) 1-300 sec SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 4 of 27

ON / OFF Regulation characteristic Hysteresis 0,1 to 99,9 C 0 210 F Output Relay (-R/M) 250 VAC, 3 A resistance load 250 VAC, 1 A inductive load Solid State (-S/M) 12 VDC, 40mA short circuit safe current (-A/M) 4-20mA insulated Load resistor max. 550 Ohm Heating - defect alarm The current which is getting used by the consumer is getting measured by the current transformer. The measurement starts only when the unit is switched on. The Alarm is getting released when the input Current limit remains. Range: 20A (Option W12) or 50A (Option W15) Adjustment: 0,0-20,0 A for range 0-20A 0,0-50,0 A for range 0-50A 0,0 switches off the functions Accuracy: ± 5% Behaviour: ON / OFF Output: Relay 250VAC 3A resistance load Threaded fastening bow Option BL 250VAC 1A resistance load Front tableau thickness 1-15 mm 4. Further functions Regulator output switch off and Display Off. All exits are getting switched off. The actual value display shows OFF. Locking functions Lock 1 Lock 2 Blocking all Parameters (theoretical value, Alarm 1, Alarm 2 and heating defect alarm). Blocking all Parameters without actual value. 5. Safety proceedings in normal use Before starting the regulator: Check all Safety installation for their function; Be sure that nobody is in danger. Check regulator at least once at a shift for visual damages and the safety installations for their functionality. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 5 of 27

6. Hazards by electrical energy Allow only qualified personnel to work on the electrical supply. Check the electrical equipment regular! Fix loose connections and change burnt parts directly. Keep the switchboard door always closed. Allow only qualified personnel to work at the switchboard. 7. Mounting notes Avoid following subjection of environmental conditions: Soot, Dust and corrosive Gases; Air moisture higher than 85% and deeper than 30% relative humidity; Condensation; Environmental temperature higher than 50 C (120 F)and deeper than 0 C (0 F); Vibrations or heavy beats; EMC-load, Installation close to power supplier and high voltage electrical equipment; splashing with liquids Safety regulations Do not use the regulator in space travel, aviation, atom reactor, medicine and explosive environment Due to the used Temperature sensor the regulator can regulate temperatures between -199 C (-199 F) and + 1820 C (+ 3300 F). For any risks of producing such temperatures is only the user liable. When a damage can occur by a mistake of the regulation a safety switch off must be carry out. Regulation range For adjusting the theoretical value in the provided range, the borders for the minimum and maximum theoretical value must be separated. Instructions, Manipulation at the unit The user is responsible to understand the operation instructions and to avoid any kind of manipulation which influenced the safety of the unit.. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 6 of 27

8. Switch board cut out The switchboard cut out for the SM6S is 45 x 45 mm. The ideal sheet thickness is between 1-3 mm. The minimum distance to other units is 30 mm. 9. Connections 16 The connection wires with 1mm 2 should equipped with according 4 mm cable lugs. The cable lugs should fasten from left under the according connecting terminals. Please see the installation terms. Mount the touch protecting cap! 1 2 3 4 17 7 8 9 10 11 18 12 SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 7 of 27

10. Connecting schema Power supply: Please see sticker at the unit. 100-240 VAC If the Voltage of a 24V-unit is 230 VAC heavy defects appears. Clamp Name Meaning 1-2 PWR Voltage supply: 100 to 240V AC 3-4 EV1 Alarm contact 17-18 DI1 Event Input: adjustment second set value 16-18 DI2 Event Input: adjustment third set value (optional) 7-8 01 Control solid state 9-12 V Not connected 10-12 AV Connection thermo element 10-11 A Connection temperature sensor PT100 / Ni120 11-12 B Bridge at PT100 Sensor connections Thermo elements direct. Thermo element Thermo element with compensation line and thermo binders! Compensation conductor Thermoelement Pt.100 3-conductor circuit. At a 2-conductor PT 100 a bridge must be wired at the unit. Pt. 100 3 - conductor The connection resistor should not exceed the value of 10 Ω for each conductor. Otherwise a higher Temperature gets measured. Pt. 100 3 - conductor SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 8 of 27

11. Guaranteed values and liability Basically our Terms of payment and delivery are significant. The manufacturer is by no means liable for any failures at persons or subjects, if they result of following respond: No intended purpose of the regulator; Inappropriate mounting, initiation, operation and maintenance of the regulator; Initiation of the regulator by defect safety installations or inappropriate mounted and not functionable safety and protection installations; Not observing the instructions given in the handbook refering transport, mounting, initiation, operation, maintenance and storing the regulator; Alterations effected without any authorization; Catastrophic cases caused by outside effects and superior force. 12. Notes Basically for the safe handling and trouble free use of this regulator is the knowledge of safety instructions. This operation manual, specially the safety instructions, must observed by all persons working with this regulator. Also all laws and rules for accident prevention at the working place must be observed. Hazards by handling of the regulator The regulator type SM6S correspond to the actual stand of the art and the official safety specification. But the possibility of hazards for persons and the machine still exists. Use the regulator only: for its intended purpose in perfect conditions all hazards which are influencing the safety of the unit must be erased. Safety rules Organisatoric proceedings. All existing safety installations must be controlled permanently. Safety installing Before starting the regulator all safety installations must be mounted in accordance with regulations and operative. Remove safety installations only, when the regulator is: Out of gear; Safe against reinitiating. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 9 of 27

Safety arrangements The operation instructions must be placed permanently at the working place. Additional to the operating instructions all general valid and local laws and reglementations for accident prevention and environment protection must be observed. Training of personnel The regulator is only to be operated by well skilled and instructed personnel. The responsibility of the personnel for the mounting, initiation, operation, maintenance and repair-work must be strictly appointed. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 10 of 27

13. Display and operators control Front view of SM6S 1 3 2 1. Process value (PV) (actual value) 2. Set value (SV) 3. Action display 4. Up-key 5. Down-key 6. MODE-key 7. ON / OFF-key 4 5 6 7 SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 11 of 27

Display 1 PV-Display Indicates the process value or setting characters in setting mode. 2 SV Display Indicates the SV (set value) or set data in setting mode. In Monitor mode, indicates MV(manipulated variable), remaining step time (program control), step number (Program control) or set value memory number (fixed value control) Action display 3 O1 Lit when control output OUT1 is ON. For direct current output type, flashes corresponding to the MV in125 ms cycles. O2 Lit when control output OUT2 (EV2, DS or DA option) is ON. For direct current output type, flashes corresponding to the MV in125 ms cycles. EV1 Lit when Event output 1 is ON EV2 Lit when Event output 2 (EV2 option) is ON AT Flashes while AT or Auto-Reset is performing. R/L Lit while in Remote action (EIT option) T/R Lit during Serial communication (C5W or C5 option) TX (transmitting) output. Keys 4 Increases the numeric value. If this key is pressed for 1 sec during Program control, the unit proceeds to the next step. 5 Decreases the numeric value 6 Selects the setting mode, and registers the set data, If the MODE Key is pressed in RUN mode for 3 sec, the unit moves to Monitor mode. 7 By pressing this key for 1 sec, one of the following items selected in (OUT/OFF key function) is indicated. Control output OFF function: Turns control output ON or OFF Auto/Manual control: Switches the Auto/Manual control. Program control: Starts or stops the program control. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 12 of 27

14. Message by switch-on the regulator When the power supply of the regulator is getting switched on, the unit carries out a self-test. If the regulator is recognising an internal error, the display is blinking. In this case send the unit back to the manufacturer. The Sensor display shows, which probe type is getting installed. This is very important to control, because the connection of a wrong thermo element causes defects. By operation the theoretical value (lower display) and the actual value (upper display) are indicated. The regulator starts to work directly. 14.1 Regulator switch ON/OFF By operation the regulator can be switched on or off by the key ON/OFF. This key must be pushed for 1 second. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 13 of 27

15. Input 15.1 Step 1 Initial setting Mode Step Display Key FS Menue name and (hold pushed for 3 Sec.) (FS = Factory setting) Operating mode (Actual PV and SV are displayed) 1 PT 100 Selection of sensors (see chapter 15.6) 2 250 Maximum theoretical value: The Operator can adjust the theoretical value to the minimum value. ( Factory adjusting FS = 250 ) 3 0 Minimum theoretical value: The Operator can adjust the theoretical value to the minimum value. (FS = 0) 4 005 Alarm type selection: 005 = Upper / Lower area alarm 007 = Treshold alarm 5 yes Only for alarm type 005 SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 14 of 27

6 1 Alarm value A1 (Option) Please note the adjusted alarm type. 0 or rather 0,0 switch off the alarm function. Alarm range: belongs to alarm type: ±199 C or minimum to maximum from choosen sensor. 7 9 Alarm hysteresis: Cares for a Hysterese between pick up and release of the Alarm Relay. 8 0 Temperature alarm 1 (A1) set up delay time: (0S) 9 Alarm enabled / disabled 10 0 Loop break alarm 11 0 Loop break alarm - span SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 15 of 27

12 001 Event input Adjust second set value 001 = 2. SW settable 000 = 2.SW not settable 13 000 Event input Adjust third set value 001 = 3.SW settable 000 = 3.SW not settable 15.2 Step 2 Main setting mode (FS = Factory setting) Step Display Key FS Menue name Operating mode (Actual PV and SV are displayed) 1 150 Input set value 1 The first set value can be adjusted by the UP/DOWN key. 2 100 Input set value 2 The second set value can be adjusted by the UP/ DOWN key. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 16 of 27

15.3 Step 4 Lower sublevel (FS = Factory setting) Step Display Key FS Menue name 150 Operating mode (Actual PV and SV are and displayed) 1 The self-optimization can be released in the startand stop phase. Please see, that the regulator switches two times. First up to 0%, then to 100% power. Between this time the optimal parameters P, I and D are getting calculated. 2 10 Proportional band range 0 999K / 0-99,9 C The Proportional band works proportional to the actual- and theoretical value at the regulation output. 3 200 Integral time range 0-999 Seconds The integral time appoints the time of the output to change the power from 0 to 100% and reverse. ATTENTION: I:D at least 4:1! 4 50 Differential time range 0-300 Seconds The differential time appoints, in which time distance to the actual- and theoretical value a reaction should happens! ATTENTION: I:D at least 4:1! 5 ARW (Anti-Reset Windup) Range: 0... 100 % (values > 50% : additional absorption to reduce overswing value < 50% : results a steeper ascent by start-up SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 17 of 27

6 1 CYCLE TIME The cycle time appoints, in which time distance the regulation output should be switched. Relay = 30 seconds SSR = 1-3 seconds 100 Maximum output (%) Normally a performance of 100% is required. By very fast systems the performace can be reduced. 8 0 Minimum output (%) Normally a performance of 0% is required. 9 0 Rate of change 10 Configuration Heating: HEAT Cooling: cool 11 1 Alarm value A1 (Option) Note the Alarmtype. 0 or 0,0 switches of the alarm function. Alarm range: belongs to Alarm type ±199 C or minimum to maximum of choosen sensor. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 18 of 27

12 0 Loop break alarm time 13 0 Loop break alarm span 15.4 Step 5 Engineering mode (FS = Factory setting) Step Display Key FS Menue name and (hold pushed for 3 sec.) 150 Operating mode (actual PV and SV are displayed) 1 Set value lock 2 001 Event input DI1 allocation SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 19 of 27

3 000 Event input DI2 allocation 4 005 Alarm type selection 005 = Upper set range value alarm 5 yes Alarm type value 0 enabled / disabled 6 1 Alarm value A1 (Option) Note the Alarmtype. 0 or 0,0 switches of the alarm function. Alarm range: belongs to Alarm type ±199 C or minimum to maximum of choosen sensor. 7 9 Alarm hysteresis: (1,0 C) Caused a hysteresis between pull-in or release of the alarm relay. 8 0 Temperature alarm 1 (A1) Adjustment delay time (0S) SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 20 of 27

9 Temperature alarm 1 (A1) Selection: Energized / Deenergized Energized: De-energerized: 10 1.000 Sensor correction coefficient 11 0,0 Sensor correction 12 0,0 Process filter time constant 13 Set value rise/fall rate start type 14 0 Set value rise rate SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 21 of 27

15 0 Set value fall rate 16 OFF Indication when control output OFF. 17 20 Autotune Bias 18 1,0 Autotune gain 19 OFF OUT/OFF key function 20 00,00 Indication time SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 22 of 27

15.5 Selection of sensor Now the regulator parameters are adjusted. If the results will not met the requirements we suggest to start first the autotuning. The system should be levelled out new. If the result are deficient again, we suggest following: 1. Double Proportional band Reduce 2 x Integral- and Differential time. Please see Formula, that I:D should be at least 4:1. By faster Systems you can adjust following ratio: 5:1; 6:1; 7:1 By starting the regulator the upper LED Display shows the adjusted Sensor. After approx. 2 sec. the actual value and the theoretical value are shown. The unit is now ready for regulation. During regulation the LED shows the actual state with OUT, A1, A2, AT. When the LED is blinking the output is activated. Is the AT LED blinking the regulator is in optimation process and should not be disturbed. (search in PID Modus for the optimal PID Parameters ). When the regulator found the Parameters, the blinking of the AT LED stops. Description: see page 12 SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 23 of 27

16. Changing the first and second set value 1. Push the MODE key. 2. The first theoretical value can be adjusted by the UP/DOWN key. 3. Acknowledge with the MODE key. The new theoretical value appears on the display. The display flips over to the set-up of the second theoretical value. 4. The second theoretical value can be adjusted by the UP/DOWN key. 5. Confirmation with the MODE key. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 24 of 27

17. Alarm type (selection) 007 - Upper threshold alarm: The alarm relay kicks in when the value exceeds (setpoint value + alarm value). Alarm value range: Minimum to maximum from configured sensor. m in m ax 002 - Lower threshold alarm: The alarm relay kicks in when the value drops below (setpoint value - alarm value). Alarm value range: Minimum to maximum from configured sensor min max 003 - Upper/lower threshold alarm: The alarm relay kicks in when the value drops below or exceeds (setpoint value ± alarm value). Alarm value range: 1 to maximum from configured sensor min max 005 - Upper/lower area alarm: The alarm relay drops out when the value drops below or exceeds (setpoint value ± alarm value). Alarm value range: 1 to maximum from configured sensor (factory setting) min max 004 - Upper alarm (does not depend on setpoint value): The alarm relay kicks in when the value exceeds the configured alarm value. Alarm value range: Minimum to maximum from configured sensor. min max 009 - Upper threshold alarm with standby: The alarm relay kicks in when the value exceeds (setpoint value + alarm value). Alarm value range: Minimum to maximum from configured sensor. The alarm is suppressed in the initial phase and is only activated when the actual value first drops to within the alarm range. min max 010 - Lower threshold alarm with standby: The alarm relay kicks in when the value drops below (setpoint value - alarm value). Alarm value range: Minimum to maximum from configured sensor. The alarm is suppressed in the initial phase and is only activated when the actual value first drops to within the alarm range. 011 - Upper/lower threshold alarm with standby: The alarm relay kicks in when the value drops below or exceeds (setpoint value ± alarm value). Alarm value range: 1 to maximum from configured sensor The alarm is suppressed in the initial phase and is only activated when the actual value first drops to within the alarm range. SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 25 of 27 min min max max

The associated parameters can be entered in the second level. This level must only be accessible to skilled personnel. Access to the Parameter-face: You can switch over the parameter face with the UP- and MODE-key. The self-optimization is reached at the first set point. You can activate the self-optimization with the UP- and DOWN key. The next parameter is reached by switching over the MODE-key. At the end of the parameter face the basic mode is reached with the MODE-key. Regulation parameter Proportional band Integral time Differential time Proportional cycle 0 to 999 C, by Pt.100 with decimal dot 0 to 99,9 C. 0 to 999 sec. 0 to 300 sec. 1 to 120 sec. Factory set: Proportional band (P) 10 C. Integral time (I) 200 sec. Differential time (D) 50 sec. Proportional cycle 30s at relay output, 3s by output with semiconductor relay. Important: To receive a meaningful regulation, the I : D ratio must be at least 4 : 1! Adjust the proportional cycle in dependence to the output type and the gradient of the controlled system. Relay output Semi-conducteur relay ma Output = 15-40 sec. = 1-5 sec. = without Proportional cycle! Attention: The cycle time at the relay output should not be adjusted under 15 seconds, because a shorter time increases the wear at the contacts. The gradient is getting calculated of the temperature rise per time. The inverse time shows the optimal proportional cycle time. Alarm date: Alarm 1, Alarm 2 (option) The value can be adjusted in the range of the chosen alarm type and probe. 18. Starting After mounting the SM6S professionally with all safety and mounting directions and after understanding the operation instructions the starting should execute like this: 1. Check on the PV-display the correctness of the sensor after switching OFF and ON the mains. If the display is not fitting with the connected sensor, the sensor must be adjusted with the right parameters of the probe (page 15). SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 26 of 27

2. The maximum and minimum theoretical value set up for the user can be adjusted in the second face (Parameter face limit dates). The user can only adjust the theoretical value in this given range. 3. Optimal regulator results: The standard parameters for the starting regulation are factory set. When the system is getting switched ON, the regulator starts with the adjusted basic regulation values. If a direct regulation result is wanted, the self-optimization in parameter face 2 are getting activated. The regulator is analysing the regulation system and calculating the optimum parameter. This optimization is also carried out during the process, when Lock 1 and Lock 2 are not adjusted. 19. Error alarm on the PV-Reading Broken probe: When a damage is detected at the thermostat or PT 100, or the adjusted maximum sensor value exceed 5%, the PV-display shows four blinking lines on the upper side ( ---- ) The regulator switches off the regulation output during this error. When the input remain under the minimum sensor value for 1%, the PV-display shows four blinking lines on the lower side ( ---- ). Self diagnosis: During the start phase the regulator controls itself. In this Phase the adjusted Sensor and the maximum value are shown! 20. Cleaning Clean the regulator front only with a wet rag. Do not use any kind of solvents in no way! SM Klebetechnik Vertriebs GmbH Otto-Hahn-Straße 19a 52525 Heinsberg /Germany Page 27 of 27