Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects



Similar documents
WHEN IT RAINS, IT POURS WATER DAMAGE RESTORATION

Energy Efficiency. Energy Efficient Home Cooling:

How To Understand Evaporator

May 14, Write Your Own (WYO) Principal Coordinators and the National Flood Insurance Program (NFIP) Direct Servicing Agent

Glossary of HVAC Terms

Case Studies. Disaster Recovery Restoration Remediation Decontamination

Molds and mildew are fungi that grow

Glossary of Heating, Ventilation and Air Conditioning Terms

Introduction to Structural Drying. Manual

Answers to Your Questions from the Webinar

air conditioners how to choose a cooling system

Characteristics of Evaporators

Question: Can a gymnasium floor be restored after being exposed to water damage?

Dealing with damp and mould growth

Preventing Mold by Keeping New Construction Dry

University of Nevada, Reno Facilities Services Department STANDARD OPERATING PROCEDURE. Facilities Maintenance Services

WET/DAMP BASEMENTS ANSWER: BASEMENT WALLS AND FLOORS CAN BECOME WET BY A LEAK, CAPILLARY SUCTION OR CONDENSATION.

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Home inspectors are not mold inspectors, however they do inspect for defects that

THE PSYCHROMETRIC CHART AND ITS USE

BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

Innovent LASER Packaged Fresh Air Conditioning Units

Lesson 36 Selection Of Air Conditioning Systems

IICRC Technical Advisory on In-Place Drying

Air-Conditioning Buying Guide

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

How do I measure the amount of water vapor in the air?

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

University of Vermont

Why is my air conditioner dripping on my customers?

Integrated Solar Radiant Systems

HOW MUCH AIRFLOW IS NEEDED?

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Renovating Your Basement

How To Dry A Building

Mooring USA Education Program

Restoring Peace of Mind.

CONDENSATION. Section Break (Next Page)

Copyright 2014 National Flood School

Quick, Low-Cost Water Dry-Out Techniques for Schools & Commercial Buildings Under Construction Case Study #3 Duration: 1-2 hours

Kiln Drying Basics for the Small Producer

Unit FFL 1 Respond to requests for fire damage limitation work

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

Dehumidification Frequently Asked Questions

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Basic S.W.A.T. Protocols

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Measuring The Right Thing For Humidity Control It s the Dew Point Stupid!

IUB Water Damage Restoration Guideline

Refrigeration Basics 101. By: Eric Nelson

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

ECHO System for Basements

How does solar air conditioning work?

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

bout your HOUSE before you start Renovating Your Basement Moisture Problems

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Basic Mold Prevention

How to Prevent Liquid Damage Property Losses

Understanding Evaporation:

THREE. Heating and Cooling

WITH A GOOD FAITH EFFORT BY BOTH TENANTS AND LANDLORDS, WE CAN KEEP MOLD OUTSIDE, WHERE IT BELONGS.

HVAC Processes. Lecture 7

bout your house before you start Renovating Your Basement Moisture Problems

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

Dealing with damp, condensation and mould growth in your home.

Old Dominion University Mold Management Plan

Moisture in Buildings A Practical Guide to Avoiding Moisture & Mold

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Natural Air Drying Corn Paul E. Sumner University of Georgia Biological and Agricultural Engineering Department

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Building Energy Systems. - HVAC: Heating, Distribution -

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

THE PSYCHROMETRIC CHART: Theory and Application. Perry Peralta NC State University

Building and Grounds Maintenance Checklist

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Infrared Moisture Detection

New Trends in the Field of Automobile Air Conditioning

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Pool Dehumidification Basics

Table Z. Troubleshooting Chart for Air Conditioners. Cause

The Fallacies of Venting Crawl Spaces January 3, 2002 Craig DeWitt, PhD, PE

Mold Preventing I nterior System

Service & Maintenance:

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Working with Restoration Companies

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

CONDENSATION IN REFRIDGERATED BUILDINGS

Temperature and Humidity

A Guide to Water Damage Restoration MISSION STATEMENT THE DOME COMMITMENT

Basement Insulation: Best Practices for Efficient, Durable, & Healthy Homes

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Part 2: Drying Out Your Home

Transcription:

4.02.08 updated Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects Moisture Removal Systems www.groundheaters.com www.wackerneuson.com

Controlling moisture on the job Challenges Rain, humidity, and temperature can cause construction materials such as lumber, sheetrock, and trim to absorb moisture, and without the right environment, it is difficult to effectively dry these materials. Water damage from Mother Nature, defective material, broken pipes, and fire can seriously harm structures and businesses. If immediate action is not taken, the standing moisture will permeate and encourage growth of mold and bacteria. Solutions Create the ideal environment for evaporation by encouraging wet molecules to migrate to dry molecules. The drier the surrounding air becomes, the faster moisture will release from saturated materials and turn from a liquid to vapor. Equipment ranging from dehumidifiers to heat exchangers to air movers is available to help manage important factors required for moisture removal: humidity, temperature, and airflow.

Effective methods to remove moisture from con Match your machine selection to your site needs Dryvex refrigerant systems Maintain a low humidity level by removing moisture from the air and surrounding material. Moisture-laden air passes across the evaporator coil causing water to condense from a vapor to a liquid. Dryvex convection systems Utilizing heat and air movement, this powerful open drying system uses clean outside air, rather than recycled air, to dry flooded structures and their contents. The outside air is conditioned to a low relative humidity of 5 to 15 percent and blown into the building using flexible ductwork. Thermostatically controlled, the supply blower circulates dry, fresh air throughout the structure. Large quantities of moisture are absorbed and extracted from the building through a second return blower. The best solution for: Speeding tape, mud, and paint processes Drying concrete Reducing mold growth Spaces occupied by people Water damaged structures Refrigerant dehumidification maintains a low humidity level safely, efficiently, and economically. The best solution for: Flooded or water damaged buildings Extracting moisture from construction materials such as: wall studs, subflooring, hardwood floors, sheetrock, ceiling tiles, and wood trim Convection dehumidification facilitates extremely quick drying while eliminating potential mold or bacteria growth in the building.

struction materials and buildings: Liquid-to-air systems Used in conjunction with any or our hydronic heaters, this closed drying system utilizes a series of liquid-to-air Heat Xchanger systems to dry flooded structures and their contents. The Heat Xchanger systems are placed inside the structure to pressurize, heat, and condition the air to a low relative humidity. Air movers are used to extract the moisture-laden air from the building. Dryvex air movers Speed drying time by improving the water evaporation process. During evaporation, moisture naturally wicks to the surface of a material before converting to a vapor. A layer of water vapor gas called the boundary layer forms. In order to speed the evaporation process, the boundary layer must continuously be swept away from the surface. These high cfm air movers are a convenient and economical way to provide rapid air movement. The best solution for: Flooded or water damaged buildings Extracting moisture from construction materials such as: wall studs, subflooring, hardwood floors, sheetrock, ceiling tiles, and wood trim Liquid-to-air dehumidification enables quick drying and eliminates potential mold or bacteria growth in the building. Works best: In conjunction with a refrigerant, convection, or liquid-to-air dehumidification system Air movers are vital to create an ideal moisture removal environment. Wacker Neuson Climate Technology is a proud member of the USGBC. Additionally, heaters featuring this logo, may assist with LEED project certification for Indoor Air Quality Credits IEQ 3.1/3.2

Control your environment Reducing drying time determines the success or failure of many construction and restoration projects. Introducing Energy in the form of Heat, accompanied with a higher airflow rate leads to greater evaporation potential, resulting in reduced drying times. 44.32 100 100 80 80 60 60 40 40 20 20-0 -0-20 -20 218.3 Grains/pound How to control the evaporation rate: Grains/pound Temperature F C Grains/ Pound Humidity If the temperature remains constant, a lower relative humidity will occur, resulting in a faster drying rate. 120 48.89 570.4 115 46.11 487.3 Airflow The rate at which evaporation will occur. A higher airflow rate will speed up the evaporation process, while a lower airflow rate will slow down the process. 110 43.33 416.1 105 40.56 354.9 100 37.78 302.3 95 35.00 257.1 90 32.22 218.3 85 29.44 184.9 80 26.67 156.3 75 23.89 131.7 70 21.11 110.7 65 18.33 92.8 60 15.56 77.5 55 12.78 64.8 50 10.00 53.6 45 7.22 44.3 Remember HAT Temperature Nothing influences evaporation rate more than heat. Rising air temperatures increase the moistureholding capacity of the air. If relative humidity remains constant, and air temperature and vapor pressure are high, evaporation will take place at a faster rate. The amount of water that air molecules can hold depends upon temperature. Hot or warm air can retain much more than cool and cold air. This chart illustrates how much moisture air can hold by temperature at saturation, 100 percent humidity.

Expandable drying solutions Drying Heating Air exchange Whether it s simply drying out construction materials or restoring a water damaged building, the Wacker Neuson Climate Technology line offers a number of solutions to match any size challenge. Mobile units are completely self-contained with onboard generator and fuel tank Shortens insurance claim cycles and decreases claim costs by reducing drying time Drastically minimizes reconstruction costs Decreases secondary damage from mold and bacteria growth Refrigerant Commercial Dehumidifiers Use a Dryvex refrigerant system to keep your restoration and construction projects on schedule and within budget. Inexpensive to run and easy to use, the Dryvex dehumidifier is guaranteed to decrease drying time. Indirect-Fired Air Heaters Versatile, innovative and robust indirect-fired air heaters offer safe, clean and dry heat and are extremely fuel efficient, helping lower operating cost and keeping your restoration projects on schedule. Wacker Neuson offers variety of models and sizes, including Diesel or Natural Gas/LP options. Air Movers Complete the perfect environment for fast, efficient drying. Equipped with an ultrahighefficiency 16-inch axial fan, the AM3000 moves an impressive 3,000 cfm on just 2 amps of power. Attach the optional caster package for top-down drying. Liquid-to-Air Heat Xchangers Finish work is a breeze with an HX Heat Xchanger system on the job. Simply position the equipment in the desired location and enjoy a clean, warm, dry environment. This accessory is used with any Wacker Neuson hydronic heater. Three models are available: HX50, HX100, and HX200. 4.02.08 updated www.groundheaters.com www.wackerneuson.com 0986105/Mar-2012/Layout Goes Studio/Printing Marek Group Key Features and Benefits: