User Guide & Operator s Manual

Similar documents
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Wireless Home Security System Product Manual (Model #80355)

SCORPION. micron security products

Alarm Security Kit - NVR

Manual for Fire Suppression & Methane Detection System

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

NESS D Zone Control Panel and Dialler OWNER S MANUAL

User Manual. Humidity-Temperature Chart Recorder. Model RH520

tattletale User Guide Consumer unit version P a g e

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Using your LED Plus keypad

GAUGEMASTER PRODIGY EXPRESS

Electronically Controlled Air Suspension (ECAS) for Trucks

Car Alarm Series 2 B 2 Buttons

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

Contents Installing the ucal Software on your PC/Laptop ucal Programmer Version Connecting the ucal Programmer to your PC/Laptop

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

GSM Autodialer Professional GJD700 Speech & Text Autodialer

CA-125 Owner's Manual

VEHICLE THEFT/SECURITY SYSTEM

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

G-100/200 Operation & Installation

ADDING and/or DELETING PIN NUMBERS (Plus other simple programming commands) in My DK-16 or DK-26 DIGITAL KEYPAD

User's Guide. Integrating Sound Level Datalogger. Model Introduction

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

MAGICAR M871A. Car alarm with two-way remote User s guide

UM-X Field display for continous level sensors

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

1R / 4-BUTTON SERIES

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

PR-D9W. GB Version 1

Stop Alert Flasher with G-Force sensor

Reference Guide and Step-by-Step Installation Manual. Table of Contents

User Guide. Temperature and Humidity Datalogger. Model 42280

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

ABS Flash Code (Blink Code) Instructions

SR-i900 Series. Phone (480)

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

air seeder monitor 1020 Air Seeder Monitor Installation & Operation Instructions

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Universal Wireless Effects Controller USER S GUIDE SA115

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

ATS Control Panel. User s Manual

What s in the Box? Welcome. The GymAware Kit. Congratulations on your purchase of a GymAware PowerTool POWERTOOL CHARGER.

Passive Anti -Theft System (PATS) Diagnostic Flowcharts. Issue: This bulletin provides diagnostic information for the Passive Anti-Theft System.

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

IQ SYSTEM DISPLAY MODULE (IQDM-P) OWNER S MANUAL

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

GSM Alarm System User Manual

Quickie Rhapsody Service Manual

REC FIM LOCKPICK INSTALLATION OPTIONS

K9 Heat Alarm Owners Manual HA-1520

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Operating Manual Color Changing Fountains

GPS INSTALLATION & USER GUIDE. Internet. Compatible with the following controllers. Nomad SD/SD2. ALL RIGHTS RESERVED Rev

HYDRA HV OPERATION MANUAL. 2.0 Making Connections on your HYDRA speed control. Rosin core electrical solder

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

Preface. Manual Revisions

Cisco SPA 500 Series IP Phones

Moomba 2007/2008. Troubleshooting (Electronic Throttle Engines)

Upgrade Instructions. View Manager 96 v Software Upgrade

MotorCycle Alarm by DEF COM 3 INSTALLATION MANUAL 80 C

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

User Guide. Model Insulation Tester / Megohmmeter

User Guide Reflow Toaster Oven Controller

Water Tank Level Monitor

OWNER'S MANUAL Installation, Operation, and Maintenance Information

Back-UPS Pro 1300/1500 Installation and Operation

DAB+ / FM Tuner Model: TU-201

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

PAC1 Door Access Controller

Home Security Alarm System

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

HWS100 Wireless Home Security System

Schlage Wireless Locks User Guide

Flarm LED indicator. Version 1.1

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

TC-9102 Series Surface Mount Temperature Controllers

Digital Keypad Use s Manual

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide

Instruction Manual Temp 4/5/6 Temperature Meter Series

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

ExStik TM ph Waterproof Meters

The Child Reminder System Installation Manual

SEC-ALARM200 WIRELESS ALARM SYSTEM

GSM ALARM SYSTEM GCM 8

Transcription:

MPM I Electronic Seed Monitor User Guide & Operator s Manual

TABLE OF CTENTS - General information 1-3 Warnings and Alarms 4-5 Monitor Operation 6 Programming 7-10 Troubleshooting 11 Replacement Parts 12 GENERAL INFORMATI MPM I Electronic Seed Monitor The electronic seed monitor system consists of a console with non-volatile memory which is mounted in the tractor; seed tubes with computerized sensors, and a planting harness to which the individual seed tube sensors connect. Seed flow for up to 36 rows, in two 18 row sections (left/right) may be monitored with one monitor. The monitor system is powered by the tractor battery (requires 12 volts DC). The console receives information from each of the sensors and translates this information. The single backlit Liquid Crystal Display (LCD) shows the active section, the number of monitored rows per section, the relative seed rate for each row (using a bar graph display) and scrolls various alarm and warning messages when a condition exists. A continuous audio alarm will sound upon system malfunction or underflow conditions for any monitored row. Alarms must be acknowledged by the user. Various warnings may sound the buzzer or flash one or more icons. The monitor will power down if no activity is sensed for more than one hour. No activity means there has been no new seed flow and no operator push key input. 1

GENERAL INFORMATI MITOR KEY FUNCTIS Each key press is acknowledged by the monitor with a short beep. Ends and saves the new setup during installation. Acknowledges and silences alarms in the operation mode Selects the application mode (left/right) at the beginning of installation setup Selects the active section(s) (left/right) in the normal mode. Does not have an affect on a system that is configured to monitor only one section. GENERAL INFORMATI LCD FUNCTIS The monitor collects data on the planting rates from all active rows and calculates an average. This average will determine the 100% mark. Seed rate for each row is then compared to the average value and the result is displayed on the bar graph. In the example below, rows 4 & 12 are indicating that they are planting 10% higher than average, where as rows 8 and 16 indicate 10% less than the average being planted. The information regarding each section is displayed alternately every 5 seconds. While operating a system with two sections programmed, one or both sections may be selected any time. When only one section is selected, the monitor calculates the average based on the remaining active rows from that section. ING SECTIS Press key once to show one section. The flashing icon shows the section that is not selected. The selected section is continuously displayed on the LCD. Press key again to activate both sections. Ex: Press key second time. The information regarding each section will display alternately every 5 seconds. For simple applications, where only one section is programmed, the display will automatically lock on that section. Pressing key will have no affect. NOTE: When alternating between two sections, the display will lock on the section containing the first recognized alarm until the alarm is acknowledged by pressing the key or the alarm condition is removed. Pressing the key will turn the beeper on. Holding the key for periods of 2 seconds increases the volume until it reaches the maximum, at which time it rolls over to the minimum level. / Powers the unit on and off. CHANGING THE AUDIO Press and hold down the key. The SETUP and icons will turn on and the beeper will sound continuously. The intensity of the sound will change every 2 seconds. After the maximum volume is reached, the next change will set the volume to a minimum and will continue to get louder every 2 seconds. When the desired volume is reached, release the key. 2 3

WARNINGS AND ALARMS WARNINGS AND ALARMS SYSTEM ALARMS A system alarm is entered when the monitor detects a faulty sensor or one of several other communication faults. The corresponding row number starts flashing and the beeper sounds. All segments on the corresponding bar graph are turned off. Pushing the key to acknowledge the alarm will turn the beeper off. The row number will continue to flash until the alarm condition is removed. If the monitor detects a faulty sensor and there is no planting activity present, the monitor will scroll CHECK CNECTI UNDER FLOW ALARMS If the seed rate for one or more rows is less than 55% of the calculated average, the corresponding 60% segment will stay on, the corresponding row number starts flashing and the alarm sounds. Pushing the key to acknowledge the alarm will turn the alarm off. The 60% segment of the bar graph remains on and the row number continues to flash until the alarm condition is corrected. NOTE: All alarms present within a short time before planting stops, are frozen on the screen and the text LOW or FAIL will display on the LCD. If the underflow is between 0%-10%, this warrants a FAIL condition. If the underflow is between 10%-55%, a LOW condition is generated. If multiple rows have an underflow condition, FAIL will display if any one or more rows is between 0%-10%. This allows the user to identify and fix the problem rows. NOTE: This warning will not trigger unless a minimum time of continuous planting has passed. NOTE: If all the rows show a seed rate of zero, the condition will not generate an alarm. It will be assumed the planter has stopped. The row numbers and the bottom 60% segment will remain on for all selected rows. MULTIPLE ALARMS If more than one alarm condition occurs at the same time, pushing the key will acknowledge all alarms that are currently displayed. For example, if one row on the left and one row on the right is alarming; pushing the key will only acknowledge one of them. However, if there are two alarms on the left, both alarms would be acknowledged with one push of the key. SECTI NOT ED WARNING If the monitor was programmed for two sections and only one is currently selected for the display (by pressing the key), the icon of the disabled section will flash for a period of 1 minute, then turn off at each power up. If seed flow is sensed in the disabled section, the icon for that section (left or right) will begin to flash. SEED PLANTING STOPPED When the monitor detects no seed flow on all rows, the monitor will emit 3 short beeps to alert the user. This warning will occur each time the planter is stopped, each time the planter is raised at the end of a row or if the mechanical drive fails while planting. NOTE: This warning will not trigger unless a minimum time of continuous planting has passed. SEED COUNTING SENSOR IN CALIBRATI WARNING All seed counting sensors run a self calibration sequence on power up. While in calibration the bottom segment of each corresponding bar graph will flash if the monitor detects movement or planting activity. If the monitor does not detect this, the message WAIT CALIBRATI will be scrolled. SEED COUNTING SENSOR TOO DIRTY WARNING After the seed counting sensors end their internal self calibration, the monitor may detect one or more sensors are either too dirty or blocked. If the monitor detects planting or movement, the corresponding bar graph remains flashing. The monitor will display CLEAN SENSORS on the LCD if no movement or planting is detected, prompting the user to clean the tubes. If the tubes are dirty, they will still show seed flow with less accuracy. If the tubes are blocked the user will get an alarm as soon as planting starts. The corresponding bar graph will remain flashing until the problem is corrected and the monitor is powered down and then powered back up. LOW BATTERY WARNING The monitor is constantly monitoring its input voltage to quickly detect low power conditions. If the monitor detects that the input voltage has dropped below 10.5V, it will display LOW POWER on the LCD, provided that the monitor does not detect planting. NOTE: After the alarms have been acknowledged and if the alarm condition is still present, the LCD will continue to display the alarm condition. 4 5

MITOR OPERATI REPLACING A FAULTY SENSOR To replace a faulty sensor: Turn the monitor off Disconnect the faulty sensor Turn the monitor back on Plug in the replacement sensor. The monitor will chirp twice to acknowledge the new sensor was learned and saved. To replace more than one faulty sensor, proceed as sated above beginning with the lowest numbered row in the left section and continue to replace sensors in increasing order. Then move on to the right section and continue in increasing row number order. NOTE: If the monitor is not turned off and then on, the replacement sensor(s) will be ignored until the next power on, at which point they will be randomly learned by the monitor. FIELD OPERATI Press the / key to turn the monitor on & off Information regarding each section is displayed alternately every 5 seconds. LEFT / RIGHT CFIGURATI Press the key once to show LEFT section only. Press the key a second time to show RIGHT section only Press the key a third time to return to each section being displayed alternately every 5 seconds. NOTE: key has no function when only a single section is being used. Press the key to increase or decrease volume. See Changing the Audio Volume Press the key to silence alarms. See Warnings and Alarms PROGRAMMING NOTE: The following steps only apply to systems that were not preprogrammed at the factory. 1. ALL the seed tubes with sensors must be disconnected from the harness and the monitor must be off. 2. Press the key. The monitor automatically enters the setup procedure. If the monitor was accidentally powered on with no sensors attached, the user can turn the monitor off at this point and the previous configuration is not lost. 3. Press the key. Each time you press the key the mode will toggle between left/right. The selected display will be solid and the configuration not currently selected will be flashing. 4. Press and hold the key to confirm the selection and continue holding until the row numbers appear on the display. During confirmation, the display will alternate between NEW and SYS to alert the user that the previous configuration will be lost. With the left/right mode selected, the monitor automatically starts with the left section. The LEFT icon shows solid and the RIGHT icon starts to flash. 6 7

PROGRAMMING PROGRAMMING 5. Plug each seed tube with sensor into the harness in a predetermined order. Row 1 first, Row 2 second and so on up to 18 rows. When a sensor is plugged in, the corresponding row number on the LCD display will stay solid, the monitor will chirp twice and the LED (Light Emitting Diode) on the seed tube sensor will turn on for approximately 30 seconds to show connection is made. NOTE: Unless there is a faulty sensor, the installer should just have to connect the sensors in the proper order without checking the monitor to acknowledging each sensor Follow steps 5 thru 7 to install the second section. If no seed tubes are installed on the second section, press and hold the key until the word DE shows on the screen followed by a long beep and the SAVE? icon turns off. NOTE: Individual seed tubes may be unplugged for special situations. An alarm will sound which can be silenced by touching the key. The monitor will recognize the seed tube(s) when reconnected. 6. When all the seed tubes with sensors for the current section are installed, check to be sure the monitor displays solid numbers for the number of sensors connected. 7. If this condition is satisfied, press and hold the key to save the setup for the current section. The SAVE? icon will show followed by continuous short beeps indicating the monitor is preparing to save. The installer has five seconds to decide if he wants to save the current configuration. During this time short beeps will sound. To complete the save, hold the key pressed until the word DE shows on the screen followed by a long beep and the SAVE? icon turns off. When the key is released the monitor will continue with the second section installation. 8 9

PROGRAMMING TROUBLESHOOTING The words WAIT CALIBRATI will scroll across the display. This simply means that the monitor is running a check of all the sensors. The red light on the back of each sensor will be illuminated while this check is taking place. After the monitor completes this check, it will go to the field operation mode, as shown to the right. NOTE: Each time the monitor is powered up, the words WAIT CALIBRATI will scroll across the display. This indicates that the console is running a check of all the sensors. After several seconds, the check will be completed and if all sensors are functional the display will show the field operation mode. PROBLEM: Single Sensor communication alarm comes on (alarm on with no bar graph and a blinking row number on a single row Faulty seed tube sensor. -Replace Sensor. Break in the harness just before the seed tube sensor. -Inspect for break in harness and repair. If break can t be found, replace harness section. The connector is dirty or corroded.-clean connector. PROBLEM: Sensor communication alarms come on for all sensors (alarm on with no bar graphs and blinking row numbers on all rows.) The monitor is faulty. -Replace monitor Break in the harness just after the monitor. -Inspect for break in harness and repair. If the break can t be found, replace harness section. Connector is dirty or corroded. -Clean connector. PROBLEM: Sensor communication alarms come on for some sensors (alarm on with no bar graphs and blinking row numbers on all rows.) Break in the harness. -Inspect for break in harness and repair. If break can t be found, replace harness section corresponding with the alarming sensors. Connector is dirty or corroded -Clean connector. PROBLEM: Seed tube sensor dirty or blocked warning comes on (after calibration, bar graph keeps blinking for a single row.) Seed tube is dirty. -Clean sensor. Faulty seed tube sensor. -Replace sensor. PROBLEM: LED on the seed tube sensor will not come on. Faulty seed tube sensor. - Replace sensor. Connector is dirty or corroded -Clean connector. Break in the harness just before the sensor. - Repair harness. PROBLEM: System low error message Pinched wire on harness. - Repair or replace harness. PROBLEM: COP error message appears Internal console error. -Press. If this doesn t help, reprogram the monitor. If still malfunctioning, send in for service. PROBLEM: Monitor not reading population. Radar is possibly not working. - Turn console on and unplug radar wire. Look for radar on error message. If faulty replace radar. PROBLEM: The alarm "Under planting" or "no planting" sounds on a single sensor while planting. (Alarm on with a single bar graph segment on and a blinking row number on a single row.) Seed tube sensor is blocked.-clean sensor. Faulty seed tube sensor. - Replace sensor. 10 11

REPLACEMENT PARTS REPLACEMENT PARTS ITEM PART # DESCRIPTI 1 VA598004 MPM I monitor console* 2 VA598005 MPM II monitor console* *Includes MPM console, mounting bracket, power adapter cable and cleaning brush. 3 L318954 4-row Harness 3 L318956 6-row Harness 3 L318958 8-row Harness 3 L318962 12-row Harness 3 L318966 16-row Harness 3 L318974 24-row Harness 3 L318986 36-row Harness other harness available 4 VA598003 Seed tube with sensor VA598503 Seed tube only 5 VA598H03 Sensor only 6 VA291009 Mux adaptor, ground speed 7 VA598708 Y Adaptor harness for MDS 8 KA6147 Magnetic Distance Sensor Kit 9 KD8751 Magnetic Distance Sensor Pulse Wheel 10 KD8771 Spring wave washer 11 VMO355519 Cleaning brush 12 VA48377 Power adapter cable 12 13

Precision Planting Counts. 30 Years of Research and Innovation in every planter. Inc. 17135 W. 116th St. Lenexa, KS 66219 Phone (913) 438-1700 Fax (913) 438-5455 www.monosemplt.com