Stepper motor driver 2H1106T

Similar documents
Datasheet of the Easy Servo Drive ES-D VDC, 8.2A Peak, Close-loop, No Tuning. Version

Avoidance of dust, oil mist and corrosive gas. Temperature. Service Environment. <80%RH, no condensation, no frosting Vibration 5.

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

FASTERCNC CO,. LTD. FASTERCNC CO,. LTD.

User Manual for CH-PFC76810

User s Manual Before using the inverter, you need to read and save the safety instructions.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

UIM2901-5A MACH3 breakout board

User s Manual. For DM542. Fully Digital Stepper Drive. Version All Rights Reserved

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

SYSTEM 4C. C R H Electronics Design

PSC-A5 Solar Charge Controller Manual

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

User s Manual. Wind/Solar Hybrid Controller NV-SW10C48. Please Read This User Manual Carefully Prior to Installation and. Operation of This Product.

WD-AMX Water Detection Controllers

POINTS POSITION INDICATOR PPI4

650W Single Output Power Supply

Points Position Indicator (PPI1) for Points Motors with Common Ground

IO-DIM6 6-Channel, Digital to Analogue Converters

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

IO-RM3 3-Stage Relay Module

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Pololu DRV8835 Dual Motor Driver Shield for Arduino

Manual. Solar Fountain Mobile Phone Charger

Electronic Control Devices The European Product Catalogue 2007

BB800 Off-Grid Solar System

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Fire & Security DETECTORS

M860. User s Manual. High Performance Microstepping Drive. For. Version All Rights Reserved

LED LIGHTING CATALOG 2014 vol.1. Dimmer Power Supplies

.OPERATING SUPPLY VOLTAGE UP TO 46 V

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

SYSTEM 45. C R H Electronics Design

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

12 Volt 30 Amp Digital Solar Charge Controller

FPAB20BH60B PFC SPM 3 Series for Single-Phase Boost PFC

Solar Controller / Battery Charger User s Manual

DLP-PU/E Instruction Manual

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

User s Manual AURORA 1.2K/2.2K

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Model: DC-A2IO Advanced HVAC Controller

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

CNC-IN tel: Instruction

TMS TANK MANAGEMENT SYSTEM

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

High Power Programmable DC Power Supplies PVS Series

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Battery Power Inverters

ST Series POWER SUPPLIES USER INSTRUCTIONS

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Micro-Step Driving for Stepper Motors: A Case Study

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Step Motor Driver User Manual

XS-3525/8S-3. Preliminary DataSheet Version 2.02

11. PROTECTIVE CIRCUITS, LED INDICATORS and FAULT CONDITIONS... 15

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Photovoltaic Solar Energy Unit EESFB

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

YSmart Technology Co.,Ltd

Contents. Document information

Electronic Control Devices The European Product Catalogue 2007

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Switch Mode Power Supply Topologies

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

DC Motor control Reversing

KONSTANTER SPL / SPL Programmable Electronic Load

3-phase, bidirectional energy meter

Magnet field- and Radiation Tolerant New Power Supply System MARATON - Technical Overview. 22-Sep-03 1

How To Control A Battery Cell Phone With A Battery Power Control System

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

GST301. (Single Protection Zone) Operation Manual

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

How To Read A Pipe From A Sensor

Advantium 2 Plus Alarm

3000W Power Inverter

Emergency lighting units EM powerled

Power Supplies 3. SDN-P DIN Rail Series

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Fire Alarm Control Panel. Family. Operating Manual

Transcription:

Stepper motor driver 2H1106T Characteristic : 1.Using new digital sinusoidal micro-segmentation algorithm 2.Support single / dual control pulse input 3.A test run function, power failure, phase memory function 4.Positioning accuracy, low noise, small temperature rise, high efficiency 5.Simple high-performance, multi-function, operation, cost-effective 6.With short circuit, overvoltage, undervoltage, overtemperature protection and improving functions 7.Motor parameters automatically adapt to the function to ensure maximum play all types of motor function Stepper Motor driver Specification : Input Power supply : AC50V-110V 6A(MAX) Output Current Drive Way Suitable stepper motor 2.0A-6.0A PWM constant current chopping,two phase Sine wave output current 85,86,110,130 series two phase stepper motor Ambient -10 ~55 15~85%RH No condensation. Non-corrosive, environment Keeping enviroment Size (L*W*H) Weight flammable, explosive, conductive gas, liquid and dust -40 ~+55, <93%RH,No condensation, no frost 160X65X115 mm 0.95Kg Setting Current 2H1106T SW8-SW10 000 001 010 011 100 101 110 111

Phase current 2.0A 2.5A 3.0A 3.5A 4.0A 4.5A 5.5A 6.0A Setting Microstep selection SW1 SW5 00000 00001 00010 00011 00100 00101 00110 00111 01000 01001 Steps/rev 200 400 500 600 800 1000 1200 1600 2000 2400 SW1 SW5 01010 01011 01100 01101 01110 01111 10000 10001 10010 10011 Steps/rev 2500 3000 3200 3600 4000 5000 6000 6400 7200 8000 SW1 SW5 10100 10101 10110 10111 11000 11001 11010 11011 ---- 11111 Steps/rev 10000 12000 12800 20000 24000 30000 40000 60000 ---- Tesp Describtion : Microstep Users can set the driver Microstep by the SW1-SW5 five switches, total 28 micro-step. When you set the microstep, pls stop the driver working The of the specific Microstep subdivision, please refer to the instructions of the driver panel figure. Output current Users can set the driver Microstep by the SW1-SW5 five switches. The of the specific Microstep subdivision, please refer to the instructions of the driver panel figure.. SW7 sets pulse mode, on as double pulse mode, Double pulse off as pulse + direction mode.,cw+/cw is Clockwise,CCW+/CCWis Counterclockwise, need to confirm the wire of stepper motor Automatic half current function Users can set the driver half flow function by SW6. "OFF" indicates the quiescent current is set to half of the dynamic current, that is to say, 0.5 seconds after the cessation of the pulse, current reduce to about half automatically. "ON" indicates the quiescent current and the dynamic current are the same. User can set SW6 to "OFF", in order to reduce motor and driver heating and improve reliability.

Self test function signal Motor Power Indicator Lightor Installation When SW1-SW5 is OFF, Inner of drive send 1K pulse to test whether the motor,wire,and self is normal PUL+ and PUL- are the positive and negative side of control pulse signal; DIR+ and DIR- are the positive and negative side of direction signal; ENA+ and ENA- are the positive and negative side of enable signal. A+ and A- are connected to a phase winding of motor; B+ and B- are connected to another phase winding of motor. If you need to backward, one of the phase windings can be reversed. It uses DC power supply,recommended working voltage is 50-110VAC,power is over 300W,voltage shouldn t be over 115VAC and below 50VAC There are two indicator lights. Power indicator is green. When the driver power on, the green light will always be lit. Fault indicator is red, when there is over-voltage or over-current fault, the red light will always be lit; after the driver fault is cleared, if re-power the red light will be off. The size of motor driver is 151 97 53 mm,mounting holes is 139mm Chest and upright installation are ok,we suggest upright installation During installation, it should be close to the metal cabinet for heat dissipation. signal interface and sequence in time :

Inner electric circuit of motor drive : Connection of Output alarm

注意 :OUT 为光电隔离 OC 输出, 最高承受电压 30VDC, 最大饱和电流 100mA 驱动器 正常工作时, 输出光耦不导通 Note : OC is output of photoelectric isolation, Max voltage capability is 30VDC,maximum saturation current is 100 MA motor driver. Output optocoupler is not conducted under the normal working condition. connection and installing size :