Analog Door Phone Model LUADS MAT Code #408466555



Similar documents
PagePac Door Phone Controller V Installation and Operation Manual

11/16/92 AT&T. AT&T Door Phone Controller. Installation and Operation Manual

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: Fax:

Universal Paging Access Module

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers , , , , , and

LOXONE 12 Channel Amplifier

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Model 1756 Test Lead Kit

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

PagePac PAGEPAL V

PCM Paging Control System

GSM Door Phone System

Add Door Phones to Your Phone System

K-TECH EMERGENCY SPEAKERPHONE INSTRUCTION BOOK

SINGLE-ZONE TELEPHONE INTERFACE

DAR-101. GB Version 1

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

How To Install A Doorbell Fon Unit

VOIP-500 Series Phone Quick Installation Guide

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

DSB-100 Portable Premium Bluetooth Speaker Owner s Manual

Operating Instructions

VPP T1250 Emergency Telephones Installation & Operation Manual

Panasonic. Proprietary Telephone for Electronic Modular Switching System MODEL NO. KX Illustrated Model: White 1

Security Auto Dialer. Owner s Manual. Please read before using this equipment.

About the HotWire Slot Standalone Shelf

About the BitStorm 6051 POTS Splitter

Product Manual. Precision Inbound Call Routing Fast Outbound Line Hunting Streamlined Telecommunications

TCB-2 Auto Answer Coupler Product Manual

System Tel (Telephones) Ltd Fax Web

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Dock-N-Talk U S E R S G U I D E. Forming a New World of Communication. SM

Doorbell Intercom Security System

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

COLOR VIDEO DOOR PHONE CDV-71BE/D

Crown Jewel Telephone entry system

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

VK-250 WARRANTY REGISTRATION FORM

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

Model 70A00-1. GSM Cellular Communications Center

Operating Instructions

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Active Monitor Box McCrypt S.T.E.V.E. 15. Order No

6002TA Analog Port Terminal Adapter User Manual

HM-W536 Install Guide

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

User guide Conference phone Konftel 100

IP DSLAM IDL Quick Installation Guide

Fire Fighter Phone System Installation Instructions

Mobile Data Power Model: MDP-25

USER GUIDE. AURA SOHO Conference Phone. Optional Accessories. External Microphone CP sold as a pair

Four-Line Intercom Speakerphone 944

Owner s Instruction Manual. 2500/2554 Telephones Message Waiting

PCM2000 Configuration Guide

User guide The Konftel 200W conference phone

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Digital FM/AM Receiver

Industrial Ringdown/Autodialer Telephone SCR Series

VIDEO DOOR PHONE SYSTEM

The Bouncer Bluetooth Stereo Speaker

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Installation and Operating Manual

Operation Manual for Users

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

IMPORTANT SAFETY INSTRUCTIONS

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

TIF-101 Telephone Interface Installation and Use

Big Button Plus 20200

Configuring the 930A for Common PBX Metallic Signaling Interfaces

Single Day Alarm Clock with. Bluetooth and USB Play-through

DK Series Handsets. User Guide V3.6. Hybrid IP Communication System. Digital Key Telephone.

Installation & Operation Manual for EC-8 Phone Line Consolidator

User Manual Door Camera

OPERATING INSTRUCTIONS

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)


Installation & Operation Manual For Emergency/Information Phones

Quick Reference Guide

Quick Reference Guide

RCD Inspection Log Book

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

PORTABLE ALARM CLOCK. Dual Alarm. FM Radio. Wake-up Sounds. USB Phone Charger G-1CR

AA9604 Auto Attendant

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)

AS-801 Promotion-On- Hold Segregator. Version 2.10

HP UPS R1500 Generation 3

USER MANUAL QUATTRO 3 CONFERENCE SPEAKERPHONE MODEL 302

Memcom Emergency Telephone

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

MultiVOIP FX SIP Gateways

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Transcription:

Analog Door Phone Model LUADS MAT Code #408466555 Installation and Use Manual Telephone line powered Two-way, hands-free communication Vandal-resistant brushed stainless steel faceplate with mounting gasket and heavy-duty call button Adjustable microphone and speaker volume Adjustable call timer duration Defeatable call timer Responds to forward disconnect Selectable Auto Answer feature allows remote monitoring Issue 2, July 2006 2003 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2106-01B 1503

Notice Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing. However, information is subject to change. Important Safety Information Always follow these basic safety precautions when installing and using the system: 1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. DO NOT block or cover the ventilation slots and openings. 4. Never spill liquid on the product or drop objects into the ventilation slots and openings. Doing so may result in serious damage to the components. 5. Repair or service must be performed by a factory authorized repair facility. 6. DO NOT install telephone wiring during a lightning storm. 7. DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations. 8. Never touch uninsulated wires or terminals, unless the line has been disconnected at the paging or controller interface. 9. Use caution when installing or modifying paging or control lines. Service Requirements In the event of equipment malfunction, all repairs should be performed by Bogen or an authorized agent. It is the responsibility of users requiring service to report the need for service to Bogen or to one of our authorized agents. Bogenʼs Applications Department may be reached at: 1-800-999-2809. 2

Package Contents (1) LUADS (1) Dual gang electrical box (4) Panel screws (1) Hex wrench Features Auto Answer The LUADS can be programmed to automatically answer an incoming call. This feature can be enabled or disabled using a jumper. Timer Duration The LUADS can be programmed to automatically disconnect a call after a preset amount of time has elapsed. The timer can be set between 15 seconds and 2 minutes. When the call is initiated by the unit, then the timer starts as soon as the button is pushed. When the call is initiated by another phone (Auto Answer), then the timer starts once the unit answers the call. With the timer disabled, the call time will be unlimited and the LUADS will not disconnect the call until a 300 ms or longer loss of loop current is detected. If your telephone line/phone system extension does not supply a loop current break when the calling party hangs up, then the call timer feature must be used (enabled). Speaker Volume Adjusts the speaker volume of the unit. Microphone Level Adjusts the microphone return talk level of the unit. In certain noisy locations (e.g., background traffic, machinery, or wind) the microphone threshold level may need to be decreased, otherwise the unit might pickup the background noise thereby causing the unit to remain in the talk mode. Noise Reduction Slowly mutes the level when background noise only, not active audio, is detected. Active LED When lit, the LED indicates that the unit is active (off-hook). Active LED is intended for diagnostic use only. 3

Programming TEL Line Connector - Analog station line connection (Tip and Ring) is made via an RJ11 connector that is pre-wired to a 2-position pluggable terminal block. Not polarity sensitive. Auto Answer Feature - The Auto Answer feature can be enabled or disabled depending on where the jumper is set. Timer - The Timer feature is jumper selectable and can be enabled or disabled. Speaker Volume - The Speaker Volume POT can be adjusted to increase or decrease the speaker volume to the desired level. Mic Level - A Mic Level POT is provided on the LUADS for increasing or decreasing the microphone return talk level. NOISE REDUCTION OFF Timer Duration - The LUADS is equipped with an adjustable call timer duration feature that automatically hangs up the unit after the preset time has Noise Reduction - The Noise Reduction feature can be enabled or disabled by setting the jumper. 4

Wiring Phone Connection To connect the LUADS to a phone system, simply connect the analog station line to the RJ11, which is already wired to a pluggable terminal block that is preassembled to the circuit board. The connections to the terminal block are not polarity sensitive. Surge Protection To increase surge protection, connect a protective Earth Ground to the spare lug provided. The location of the spare lug is shown below. 5

Installation The LUADS comes with a standard dual gang electrical box. Make all electrical connections prior to installing the LUADS into the electrical box. Surface Mounting the LUADS (Indoor/Outdoor) 1. Mount electrical box. 2. Make electrical connections (see Wiring) and attach the faceplate to the electrical box using the four hex drive screws (tool provided). 6

Specifications Power: Telephone line powered (18V DC / 20 ma minimum) Timer Duration: 15 seconds to 2 minutes Loop Current Loss Disconnect: 300 ms minimum Ring Voltage: 40V AC RMS minimum REN: 0.7A Connections: RJ11 pre-wired to a 2-position pluggable terminal block Earth Ground lug Dimensions: 5" W x 5" H x 2-1/4" D (fully assembled) 4-5/8" W x 4-5/8" H x 2" D (aluminum box) Product Weight: 4 lb. 7