MLD 500, MLD 300 Multiple Light Beam Safety Devices and transceiver with integrated muting

Similar documents
MLDSET Light Beam Safety Device Sets for access guarding with muting function

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Barcode Reader Series BCL 31, BCL 32, BCL 34

SAFETY LIGHT CURTAINS

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Mechatronics Automation Technology

MSI-s/R. Modular Safety Interface. CONNECTING AND OPERATING INSTRUCTIONS Original Instructions. without prior notice /05.

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Introduction to the Actuator Sensor-Interface

Safety Light Curtains. We make safety easy.

Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs

IFEA Industriell kommunikasjon. AS-i Training

OPERATING INSTRUCTIONS S300. Safety laser scanner

Storage and conveyor APPLICAtIoNS EFFICIENtLY SoLVED

SMS 4 / SMS 5 safety mat Product information

Our smallest sensor. F 10 laser sensors in a subminiature design. Optical sensors Ultrasonic sensors Inductive sensors Capacitive sensors

HERZ-Thermal Actuators

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

OPERATING INSTRUCTIONS S3000. Safety laser scanner

PROFIBUS fault finding and health checking

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

EUROMAP 78. Electrical Interface between Injection Moulding Machines and External Safety Devices. Version 1.0, November pages

W 27-2: The photoelectric switch series with expanded possibilities

It simply works! Safe process monitoring.

The CP FO provides access to different communication services of the PROFIBUS bus system:

Permissible ambient temperature Operation Storage, transport

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Industrial Communication

Automatic Fire Fighting Monitors

Introduction to PROFIBUS and PROFINET

Industrial Bar Code Scanners

Product Information Sheet UH36 Hi Pot Tester

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

E3T Miniature Photoelectric Sensors

FACTORY AUTOMATION MANUAL ID-NET SETUP PROCEDURE USING PROGRAMMING BARCODES

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Single Mode Fiber Lasers

Safety Relays ESM/ESM-F

Monitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

MINIMAT-EC-Servo Screwdriver Spindles

Productivity Solutions for Lean Manufacturing

NC-12 Modbus Application

SAFETY ENGINEERING SOFTWARE

Presence Sensing Safety Devices

New XUY roller sensors

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Simple. Intelligent. The SIMATIC VS 100 Series. simatic MACHINE VISION.

S-series DeviceNet Interface Card

Industrial Bar Code Scanners

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

User and installation manual

WHITE PAPER. A Comparison of Conventional and Robotic Palletizers

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Combi switchbox with integrated 3/2 way pilot valve

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Electrical connection

Automatically identify your pallets and storage locations. Our Auto ID solutions will save you time and money.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

ELM Security System Electronic Locking & Monitoring

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Charge Controller CC611/CC612 Preliminary datasheet

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

CLV45x Bar Code Scanner

Alpha 488 S. Twisting in a new dimension

CLV440/442 Bar Code Scanner

The SISTEMA Cookbook 4

SCHMIDT ManualPress 300 Series Manual Presses with Process Monitoring

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

BOS 73K... BOS 74K...

TruBend: More. bending. freedom. Machine Tools / Power Tools Laser Technology / Electronics Medical Technology

Multizone Application >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138

OZW30. Central Unit SYNERGYR

Industrial Bar Code Scanners

Product Profile Machine Safety - Jokab Safety products

Multi-Protocol decoder with Load regulation

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

Linear Motion & Assembly Technologies - Guarding System

Safety at injection moulding machines

S a f e G u i d a n c e. Single Lamp Control and Monitoring

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

W150: Miniature photoelectric switch series with completely integrated electronics

Line Monitoring and Control in Subsea Networks

CP Page 1342 Mar 2008 Siemens ITS

PHOENIX CONTACT Features

PLICSMOBILE: Measurement data via the mobile network

Laserlyte-Flex Alignment System

Transcription:

MLD 500, MLD 300 Multiple Light Beam Safety Devices and transceiver with integrated muting PRODUCT INFORMATION

MLD the cost-effective alternative. The new Multiple Light Beam Safety Devices with integrated cost savings potential. The Multiple Light Beam Safety Devices of the MLD 300 and MLD 500 series are active opto-electronic protective devices for persons at access points or at hazard locations of machines and plants. They are available as 2-, 3- and 4-beam transmitter-receiver systems as well as 2- and, for the first time, 3-beam transceiver systems. The user can select from the several function classes of the MLD series to get the optimal model for the application and respective requirements. In addition to the start/restart interlock and contactor monitoring functions, various muting modes can be selected. No PC is necessary for configuration, as the functions are set via the pin assignments at the connection of the devices. Thus, no additional modules are required and, should it be necessary to exchange a device, the sensor does not need to be reconfigured. Standards conformity MLD 300 MLD 500 Type in accordance with EN/IEC 61496 Type 2 Type 4 SIL in accordance with IEC 61508 and EN/IEC 62061 SIL 2 SIL 3 Performance Level (PL) in accordance with EN ISO 13849-1 PL d PL e

Access guarding, perimeter guarding, muting your requirements are decisive. Transceiver innovation The 3-beam transceiver can replace more complex systems. Suitable for low temperature environment Completely functional up to -30 C. Simple start-up All settings, e.g. configuration of the muting modes, are made without the use of a PC; a device can be replaced by means of Plug & Play via M12 connection technology without any programming. Device versions with integrated AS-i Safety interface Direct connection to the AS-i bus without additional coupling modules. Muting without additional devices Integrated muting functions, configurable via pin assignments. Status indicators optionally included in the receiver. Pre-mounted Muting Sensor Sets for L- and T-designs enable sequential and parallel muting. Fast and precise laser alignment Integrated laser alignment aid (option) for easy and fast alignment for long distances. 7-segment display Easy determination of the sensor behavior and appropriate countermeasures.

Whether transceiver or transmitter-receiver system the MLD advantages are always included. The respective equipment (function class) of the MLD series can be selected depending on the application. This applies not only to integrated muting functions, but also to other optional performance characteristics. The MLD 330 and MLD 530 series has, for example, a 7-segment display, which you can use to immediately determine the cause of sensor behavior and initiate the proper countermeasures. Transceiver system Transmitter-receiver system This system consists of an active transceiver (transmitter/ receiver in one housing) and a passive Deflecting Mirror without electrical connection. Systems consisting of transmitter and receiver are well-suited for high operating ranges. 2- and 3-beam systems available Operating range from 0.5 to 8 m M12 connection technology, also with integrated AS-i Safety interface High robustness against interference through multiple scanning 2-, 3- and 4-beam systems available Operating range type 1 (MLD -R /-T): 0.5 to 50 m Operating range type 2 (MLD -xr /-xt): 20 to 70 m M12 connection technology, also with integrated AS-i Safety interface High robustness against interference through multiple scanning Function MLD 310 MLD 312 * MLD 510 MLD 320 MLD 520 MLD 330 MLD 530 MLD 335 MLD 535 Automatic start/restart X X Start/restart interlock (RES) X X X Contactor monitoring (EDM) X X X Configurable operating modes X X X 2-sensor muting (timing controlled, sequence controlled) X 4-sensor muting (timing controlled) X Laser alignment aid (optional for transmitter-receiver systems) X X *) MLD 312 with external test

Alignment and mounting a child's play. Easy alignment with integrated laser alignment aid. The series is predestined for wide-area perimeter guarding, which is realized with Deflecting Mirrors. With the integrated laser alignment aid, adjustment of such safeguards is noticeably simplified. A reflective element integrated in the cap on the receiver side of the system ensures clear visibility of the alignment laser spot, even over long distances. The Deflecting Mirror columns necessary for perimeter guarding are simply and quickly aligned, step-by-step. The setup time is considerably reduced. Multicolored status indicator The practical aid for daily operation: the colored indicator displays the respective sensor operating state, even over large distances - and during muting, of course. BT-240 swivel mount (optional) With the swivel mount, the safety sensor can be flexibly turned 240 on its own axis, easily aligned and reliably mounted an extremely practical solution for further simplifying use of the devices and for accelerating the installation. BT-P40 clamp bracket (optional) With the clamp brackets, the safety sensor can, when used in device columns, be flexibly adjusted in height and easily aligned in its vertical position. Easy alignment with integrated laser alignment aid when setting up access guarding.

Integrated AS-i interface. The Multiple Light Beam Safety Devices of the MLD series are available with an integrated AS-i Safety interface. The MLD/AS-i safety sensors can be integrated immediately into the AS-interface network, i.e., without additional safety-oriented coupling modules and hence cost-effectively.

Configure muting modes without a PC. With the Multiple Light Beam Safety Devices of the MLD series, a total of 6 different muting operating modes can easily be set. Configuration is performed by means of wiring or pin assignments at the plug and socket. Further auxiliary equipment, such as a PC, software etc., is no longer required and additional muting devices are not required. When setting up the muting application, this considerably simplifies the overall construction. Freely configurable muting! With the individual operating modes, the sensor is well equipped for a wide range of muting applications. In addition to 2- and 4-sensor muting (timing controlled, sequence controlled), partial muting is, for example, also possible. In this case, the lower beams can be muted while the upper beam remains active. As a result, a safeguard that would otherwise be necessary, e.g. by means of guards or other protective sensors, can be eliminated. Helps reduce cabling! If a muting signal comes from a system control, the user can use the 8-pin plug (machine interface) directly on the sensor for this signal. This reduces cabling requirements. Further-more, the muting enable function can be used to enable or disable the muting sequence via an external signal. This increases security against tampering.

Muting accessories for automated transfer stations. Whether for timing controlled or sequence controlled muting MLD devices are designed to simplify the setup of muting solutions as much as possible. For example, various Muting Sensor Sets with pre-mounted sensors make installation fast and easy. MLD in L-shape design for sequence controlled 2-sensor muting. The Muting Sensor Set, available as an accessory, includes two sensors or two reflectors. The entire device is premounted and prealigned. L-shape designs are used in situations where pallets exit danger zones, particularly if little space is available outside of the danger zone.

MLD accessories for T-shape design for timing controlled 4- and 2-sensor muting. With these muting types, the transport material can be moved through the protected field in both directions. Timing controlled 4-sensor muting is used if the specific application situation requires that the muting sensor light beams do not cross, but must instead be parallel, e.g. due to reflective materials or interfering environmental conditions. Muting occurs both during the forward movement as well as during the backward movement. Decisive for the triggering of muting is the sequence in which the muting sensors are activated. With the Muting Sensor Set, the user no longer needs to worry about how the muting sensors are configured.

Safeguarding with and without muting simply innovative! The series can be used with standard access guarding as well as for applications where muting is required. Here, too: just connect and the device is immediately ready. Access guarding with MLD 500 Multiple Light Beam Safety Devices in a robotics application. Access guarding with 3-beam transceiver of the MLD 300 series for conveyor and storage systems. The operating range changeover of the MLD sensors prevents mutual interference when several systems are close to each other. MLD 500 Multiple Light Beam Safety Device with integrated muting indicator in an AS-i Safety application with sequence controlled muting.

AS-i-based muting simple, efficient, economical. MLD with ASM a very good team. In cooperation with the Leuze electronic Safety Monitor ASM-m, the MLD Multiple Light Beam Safety Devices permit the easy construction of access guarding with muting based on AS-i Safety at Work. Fewer addresses more slaves. The ASM-m Safety Monitor takes care of controlling the muting process, including driving the muting indicator integrated into the MLD via AS-interface. It is now no longer necessary to assign an AS-i slave address specifically for the muting indicator. This also applies to an external muting indicator connected to the local socket of the safety sensor. This saving allows even more AS-i slaves, such as safety sensors, to be connected to an AS-i network for each AS-i Safety Monitor.

Optoelectronic Sensors Cubic Series Cylindrical Sensors, Mini Sensors, Fiber Optic Amplifiers Measuring Sensors Special Sensors Light Curtains Forked Sensors Double Sheet Monitoring, Splice Detection Inductive Switches Accessories Identification Systems Data Transmission Systems Distance Measurement Barcode Readers RF-IDent-System Modular Interfacing Units Industrial Image Processing Systems Optical Data Transmission Systems Optical Distance Measurement/Positioning Mobile Code Readers Safety Sensors Safety Systems Safety Services Safety Laser Scanners Safety Light Curtains Transceivers and Multiple Light Beam Safety Devices Single Light Beam Safety Devices AS-i-Safety Product Range Safety Sensor Technology for PROFIBUS DP Safety Switches, Safety Locking Devices and Safety Command Devices Safety Relays Sensor Accessories and Signal Devices Safety Engineering Software Machine Safety Services Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Phone +49 (0) 7021 / 573-0 Fax +49 (0) 7021 / 573-199 info@leuze.de www.leuze.com en 03-2013/01 601021