Shortened Manual. For the full version of the manual please go to:

Similar documents
Dive computer, software version 1.17

DIVE COMPUTER SYSTEM INSTRUCTION MANUAL (ios version)

LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided.

AERIS F10. Watch Free Dive Gauge. Operating Manual. (cover art provided separately)

Net Ready. Color Dive Computer. Instruction Manual

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

SUUNTO DX USER GUIDE

SweetPea3R-200 User Guide Version 1.1

Watch GPS Instruction Manual. If you have any other questions or concerns, please call or go to

Instructional videos are posted at:

G-PORTER. Portable GPS Tracker GP-102 User s Manual

Procedure for updating Firmware of EZ4 W or ICC50 W

Smart Apnea Computer. Instruction Manual

G-100/200 Operation & Installation

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

S320. Contents. Page. Components 3. Quick Start Guide 4. Settings 6. Brightness. Volume. Language. Calibrate the screen. Power save.

SUUNTO EON STEEL 1.2 USER GUIDE

FREEDOM. Technical diving computer. from DIVESOFT. User Manual

CONTENTS ABREVIATIONS/TERMS...7 WARRANTY, NOTICES, MODEL...8

cressi.com GIOTTO USER MANUAL

Motion Activated Camera User Manual

GPSMAP 78 series. quick start manual. for use with the GPSMAP 78, GPSMAP 78s, and GPSMAP 78sc

SUUNTO D4I USER GUIDE

System update procedure for Kurio 7 (For build number above 110)

How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)

12 Volt 30 Amp Digital Solar Charge Controller

MAGICAR M871A. Car alarm with two-way remote User s guide

ix3m Dive Computer Installable Apps Manual ver. 1.1

User Manual. Product Model: MiTraveler 10C3. OS: Android 4.0

User Manual. Product Model: MiTraveler 7D-4A. OS: Android 4.0

Using AORUS Notebook for the First Time

ix3m Dive Computer Installable Apps Manual ver. 1.0

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

UPS Monitoring and Management Software

ATOM 3.0 OPERATING MANUAL ATOM 3.0 DIVE COMPUTER OPERATING MANUAL

HOOK-3x DSI. Operation manual. lowrance.com ENGLISH. HOOK-3x DSI

Eclipse 180 User s Manual

Using the T&D Thermo App with TR-7wf Data Loggers

4-Channel Thermometer / Datalogger

Section 1: Introduction Section 2: igolf Neo Section 3: igolf Neo Sync Section 4: Appendices... 26

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

PeopleGIS Leica RTK GPS Instructions

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

OCSM Series. High Resolution Digital Crane Scale. User Guide

Hi-Tech Dive. For Experienced Divers

Using GIGABYTE Notebook for the First Time

WARNING - is used in connection with a procedure or situation that may result in serious injury or death.

User s Manual for Fingerprint Door Control Software

Quick Start Guide RIVA/Athena Sea-Doo ECU

en COBRA3 USER S GUIDE

245YDS 3 9:30AM P4 USER GUIDE

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

UNIVERSAL BLUETOOTH KEYBOARD CASE FOR TABLETS 7-8 INCHES

1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS WARNINGS, CAUTIONS, AND NOTES SUUNTO Vyper2 AT A GLANCE

Firmware & Software update procedures Amicroe TouchTAB IV.

B2W Maintain. Setup and Preventive Maintenance

LCD MONITOR / 8 CHANNEL DVR COMBO

SUUNTO ZOOP USER S GUIDE

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

SNMP Web Management. User s Manual For SNMP Web Card/Box

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Table of Contents. System Requirement of MP3 Player: Connection and Downloading Downloading DRM10 Files... 8.

SD Memory Card Recorder Instructions. ver

iloq P10S.10/20 Programming device User's Guide

Unauthorized reproduction of any or all of this manual is strictly prohibited. The contents of this manual are subject to change without notice.

Keep it Simple Timing

Bluetooth Installation

Using GIGABYTE Notebook for the First Time

Quick Start Guide to computer control and robotics using LEGO MINDSTORMS for Schools

Watch Your Garden Grow

Using GIGABYTE Notebook for the First Time

Tablet PC User Manual

Bluetooth Handsfree Kit. Car Speakerphone (For Bluetooth Mobile Phones)

OCS-S High Resolution Digital Crane Scale

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc

Specifications. What s Inside The box

AK10 INSTRUCTION BOOK INSTRUCTION MANUAL

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, and 62st

Video Baby Monitor System. User Guide

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

Fig. 2. Fig. 1a. Fig. 1b. Fig. 3

Acellus Natural 3D Tablet

Device Diagram Compatible with: Charging your wristband

5X, Mark 5X, Mark 5X Pro & Elite 4X

Alber Training and Education Product Tutorial. Battery Monitor Data Manager Software (BMDM)

4G LTE router: MIFI-4G

User Manual. Thermo Scientific Orion

NEED MORE HELP? PLEASE SEE OUR FAQ SECTION AT:

Model: Manual DC: WIRELESS COLOR FORECAST STATION

PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

40. Rebreather Full Cave Diver

Digital Video Recorder Client and Network Manual V1.1 Table of Contents

TABLE OF CONTENTS 1. GENERAL INFORMATION CHECKLIST GETTING STARTED SUUNTO T6 FEATURES CARE AND MAINTENANCE...

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

KViewCenter Software User Manual 2012 / 04 / 20 Version

JVC Monitor Calibration 2 User's Guide

Infrared Scouting Camera. Ltl 5210(5MP) & Ltl 5210A(12MP) USER S MANUAL

Transcription:

Shortened Manual For the full version of the manual please go to: http://liquivision.com/docs/xen_user_manual.pdf Liquivision Products, Inc -1- XEN Manual

CONTENTS IMPORTANT NOTICES... 3 MENU TREE... 4 USER AGREEMENT AND WARRANTY... 5 GETTING STARTED BEFORE DIVING THE XEN... 5 Turning the XEN on/off... 5 Register Your Unit/Activate Your Dive Software... 5 Setup Time/Date & Battery Type... 6 GETTING STARTED FEATURES OF THE XEN... 6 MENUS... 7 Shut Off... 7 LOCK/UNLOCK... 7 Dive Log... 7 Simulate Dive... 7 Alarms... 7 Connect to PC... 8 DIVE DISPLAYS... 9 Basic Information... 9 Battery Indicators... 9 Battery Savings Mode... 9 Stopwatch... 10 Reset AVG... 10 Ascent/Descent Indicators & Alarms... 10 Exiting the water... 10 Last dive information... 11 ALTITUDE COMPENSATION/SURFACE PRESSURE ADJUSTMENTS... 12 XEN PC INTERFACE... 12 CONTACT INFORMATION... 12 Liquivision Products, Inc -2- XEN Manual

IMPORTANT NOTICES Abbreviated Manual This manual is a shortened version of the manual for quick setup and reference. For the full detailed user s manual, please visit: http://liquivision.com/docs/xen_user_manual.pdf. WARNING DANGERS OF DIVING Scuba diving is a dangerous sport, and can lead to injury, disability or death. Always dive within the limits of your training, skills and experience. Technical diving activities, including decompression diving, mixed gas diving, rebreather diving, wreck and cave diving, all substantially increase the risks of scuba diving. You can die while diving. WARNING ELECTRONICS CAN FAIL ALWAYS CARRY BACKUP The XEN dive computer hardware, like any electronic equipment whose components mature and age. If they fail during your dive, they can stop providing you with critical information. You must have a plan to handle the failure of the XEN dive computer during your dive. You should carry backup instruments, including a depth gauge, submersible pressure gauge, digital bottom timer or dive watch, a compass, and have access to decompression tables. Do not risk your life on only one source of information. WARNING ALWAYS CHECK FOR SOFTWARE UPDATES The XEN dive computer software likely still has bugs. We have looked for them and tried to eliminate them, but they can still appear during use. Bugs can cause the units to provide inaccurate or incomplete information, or cause the unit to reset or turn off and stop providing any information at all. You should always check for software updates (http://liquivision.com/downloads/xensoftwarehistory.php) and install all applicable updates, every time you prepare to use the XEN dive computer. Liquivision Products, Inc -3- XEN Manual

1. Shut Off 2. Lock 3. Dive Log 4. Display Settings 4.1. Brightness 4.2. Auto Dim 4.3. Refresh 4.4. Layout 4.5. Velocity 4.6. Stopwatch DF 4.7. Dark Mode 4.8. Show Hours 4.9. Colours 4.10. Simulate Dive 4.10.1. Depth 4.10.2. Time 4.10.3. Speed 4.10.4. Start 4.10.5. Cancel 5. Alarms 5.1. Alarms 5.2. Depth 5.3. Time 5.4. Ascent Rate 5.5. Descent Rate 6. Preferences MENU TREE 6.1. Units 6.2. Log Period 6.3. Tap Sens. 6.4. Tap Count 6.5. Min. dive 6.6. Min. SI 6.7. Status 6.8. Battery Type 6.8.1. White ER144335M 6.8.2. Blue ER17335M 6.8.3. Green ICR1340 6.9. Battery Meter 6.9.1. Symbol 6.9.2. Volts 6.10. Battery Test 7. Salinity 8. Time/Date 8.1. 12h/24h 8.2. Time 8.3. Date 8.4. Year 8.5. Calibrate Time 8.6. Exit 9. Connect to PC 10. Exit Liquivision Products, Inc -4- XEN Manual

USER AGREEMENT AND WARRANTY Please go download our user agreement and warranty: http://liquivision.com/xen_manuals.php. You must accept the User Agreement and Warranty in order to active the software and begin using your product. If you do not, you must return your unused product within 30 days. GETTING STARTED BEFORE DIVING THE XEN Turning the XEN on/off To turn the unit on, simply install a new or charged battery and tap on the top three times. To turn the XEN off, select Shut Off from the main menu. Register Your Unit/Activate Your Dive Software To register your unit, you must visit: http://www.liquivision.com/activate.php. Before registration, you can navigate through your unit s menus, but it is not ready to dive. You will see the Unit is locked screen (below, left). Once you enter your information and agree to our User Agreement and Warranty, you will be given a PIN number. Once you select the Enter PIN option you will be able to type this PIN into your unit by tapping up and down on the XEN. Freediving Software The Xen has the option to use Freediving Software available here: http://liquivision.com/downloads/xen-freesoftwarehistory.php. The Freediving Software offers advanced freediving decompression calculations in order to avoid decompression sickness as well as 3 modes (life deco, manual deco & gauge mode) to choose from. The integrated dive planner can be used to plan nitrox deco after deep dives. The Freediving Software is capable of sampling every 4 seconds for the dive log. It also offers a freediving display with larger numbers, colour customization and surface interval in minutes & seconds. For more information please visit: http://liquivision.com/xen_freedivespecs.php. Liquivision Products, Inc -5- XEN Manual

Setup Time/Date & Battery Type Once you have registered and unlocked your XEN unit, the main screen will still say NOT Ready to Dive: Edit Your Time/Date, Battery Type. This information must be entered before the unit is dive ready. To do this, go to date/time on the main menu. You will also need to set the battery to the type you are using. Please go to preferences and select battery type to select the correct battery. Battery types and names are below: DISPOSABLE RECHARGEABLE ER 17335M LFP123A ICR16340 1700mAh 530mAh 650mAh Blue White Green GETTING STARTED FEATURES OF THE XEN Battery Compartment Color OLED Display Front Bungee Holes Front Strap Holes Infra Red Aperture (for connection to PC Interface) Serial Number & CE Mark Liquivision Products, Inc -6- XEN Manual

MENUS Tap 3 times on the top of your unit to enter the menus. Tap left on this option to turn your XEN off. 1 Shut Off 2 LOCK/UNLOCK This menu item allows you to lock all your menu settings so they cannot change accidentally, though you will still be able to tap through the menus. To lock, just select the LOCK menu item and enter 123. Your XEN is now locked, and the menu item changes to UNLOCK To unlock, just select UNLOCK and enter 123 once again. When a unit is put in LOCK mode, the scrollbar will turn Red. Once you unlock, the scrollbar will turn back into green. 3 Dive Log The Dive Log keeps track of dives you did with your XEN, including their depth and temperature profiles. With use of a XEN PC Interface and related software you can download this information to your desktop or laptop. The number of dives recorded by the Dive Log depends on the Log Period you select. The default setting is 10 seconds and on this setting you will be able to record approximately 1500 hours of dive time with one tank. 4 Simulate Dive This option is here so you can experiment with your dive screen without getting yourself or your XEN wet. When you enter Simulation, it will open sub-menu asking you for depth and time of the dive, its speed and then you can select Start. 5 Alarms Your XEN can display visual alarms when you exceed any of the following parameters: Maximum depth Maximum dive time Maximum ascent rate Maximum descent rate When the alarm is activated for any parameter, that piece of information will start blinking on your screen for one minute. If you do not correct the situation within one minute, the parameter display will invert (i.e. it will appear as black letters on colored background) until you correct situation causing the alarm. Once you do that, the alarm will turn off. The only exception is a time alarm. It will blink for 1 minute, after which it will go back to normal. Liquivision Products, Inc -7- XEN Manual

6 Connect to PC Tap into this menu item before starting the download of your dive logs in your PC application of choice. Refer to its manual for more information. If you tap into this item accidentally, don't worry the wait for PC communication will time out after 30 seconds, and you will be back to main menu. Note that you don t have to select this option to update your firmware. Liquivision Products, Inc -8- XEN Manual

DIVE DISPLAYS & DIVE MENUS 1 Basic Information STANDARD SIMPLE ALTERNATE LARGE 2 Battery Indicators - If the battery icon is yellow on the surface, you should change your battery before beginning your next dive. - If the battery icon is yellow underwater, you have enough battery life to complete your dive. - If the battery icon is red on the surface, you MUST change your battery immediately. - If the battery icon turns red during your dive, you should stop your dive and begin your ascent immediately, while still following proper ascent protocols (proper ascent speed, respect the Safety Stop) 2.1 Battery Savings Mode In the event that your battery is very low during the dive, your XEN will go into Battery Savings mode. It is a mode that tries to preserve the battery as much as possible, so that the XEN keeps functioning as long as possible. This mode changes the following things: all the information on the display will turn green (the color that is most powereconomical) the display brightness will be set to low WARNING You must change your battery immediately when the indicator turns red Lithium batteries sustain high power for a long time, but once the power starts to drop, it does so very fast. A red battery indicator means that the battery power will drop to insufficient power within a few minutes. Liquivision Products, Inc -9- XEN Manual

3 Stopwatch The Stopwatch is a timer that you can turn on and off, start, pause, and restart during your dive. To access the stopwatch, tap three times on the top of the unit to access the menus. The stopwatch is the first option. Here is how it appears in each of the four screen layouts: STANDARD SIMPLE ALTERNATE LARGE If the Stopwatch is Off, your XEN s underwater menu has an item called Stopwatch On. If you select this item by tapping either side of your XEN unit, you will activate the Stopwatch function and you will see your dive display rearrange itself it will show the Stopwatch in addition to the information it was previously displaying. When the Stopwatch function is On and you return to the underwater menus, you will see a menu item called Stopwatch, and this takes you to the submenus that control the use of the stopwatch. Stopwatch Shortcut: if the Stopwatch is On, then by tapping three/five times on a side of your XEN, you will be taken directly to the stopwatch sub-menu: 4 Reset AVG This option will reset the average depth that has been calculated from the beginning of the dive, and start calculating it from this point onwards. Keep in mind, however, that the average depth in your dive log will be average depth over the whole dive. 5 Ascent/Descent Indicators & Alarms The XEN provides you with a number of graphical cues to help you manage your descent and ascent rates, based on the Alarms you have set up. To access them go to preferences on the Xen s main menu and turn velocity on. Velocity: OFF or not ascending/descending Velocity: ON, ascending at 9 mpm 6 Exiting the water Once you are shallower than 0.6 meters/2 feet, your XEN will go back into surface mode and offer you access to surface menus. However, for next few minutes, it will remain in post-dive mode. You can control length of this period, in menu setting Minimum Surface Interval. This means that if you resume your dive within Liquivision Products, Inc -10- XEN Manual

that period, it will be counted as continuation of previous dive, instead of a new one. This also means, that all the numbers, such as maximum depth, average depth, dive time, etc. will not be reset. 7 Last dive information When on the surface, and not in Sleep Mode, your XEN will display information about the last dive that you have done. Surface interval it is time elapsed since your last dive. If it is less than 24 hours, you will see the number of hours and minutes. If it is more than 24 hours, you will see number of days and hours. If it is more than 10 days ago, you will not see any surface interval. Last depth is the maximum depth of your last dive, with one decimal place. Depending on your unit settings, it will be either in meters, or in feet, and you will see m or ft printed after the number. Last time is the total time of the last dive, displayed according to your dive time settings either as total number of minutes, or as hours:minutes. Liquivision Products, Inc -11- XEN Manual

ALTITUDE COMPENSATION/SURFACE PRESSURE ADJUSTMENTS Your XEN continuously tracks atmospheric pressure to determine the surface pressure at the start of your dive. When it senses a sudden change in ambient pressure, it understands that you have entered the water and that a dive is beginning. Your XEN can generally distinguish between a sudden change in pressure caused by water entry, vs. other types of sudden changes in pressure, such as a plane taking off, or driving up a mountain. You can always check what XEN assumes as the current surface pressure by going to the Status screen. XEN PC INTERFACE The XEN PC Interface can be used to download your dives and to update your XEN software. Connect the USB cable provided to your PC and to the PC Interface At this point, you should get a message New Hardware Detected Place the XEN unit on its side, with the PC interface aiming for the eight holes on the backplate The distance from the PC interface to the XEN should be 2-4 cm or 1-2 inches You need to install the drivers onto your PC in order to perform the update. Please see www.liquivision.com for more details. CONTACT INFORMATION 200-3731 North Fraser Way Burnaby, BC, Canada V5J 5J2 (604) 299 0167 info@liquivision.ca www.liquivision.com Liquivision Products, Inc -12- XEN Manual