Section F Index PEOPLE PROTECTIVE DEVICES

Similar documents
Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION , PAGE 1 SECTION WIRING DEVICES

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Electrical Grounding. Appendix C

Generator DoCKInG StatIonS

Title: Grounding and Bonding Rev-01

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Electrical Hazards. Power Tools. Extension Cords

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

ADM1TE 5/30A DIN rail single phase two wire energy meter

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

ELECTRICAL INSPECTION BULLETIN (Effective )

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Construction work requires electrical

User's Guide. True RMS Industrial Multimeter

12-Volt 10-Amp Regulated Power Supply

Series 8146/5-V37 and Series 8150/5-V37

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

INSTALLATION & SERVICE MANUAL. Display Panel

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Manual Ranging MultiMeter

Section B: Electricity

CHARGING SYSTEMS INTERNATIONAL

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

IEC Connectors. Introduction

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ASCO SERIES 185 Power Transfer Switches

MCR1900 Media Converter 19-Slot Chassis

Operating Instructions

Universal MATE-N-LOK Connectors

ORIGINAL CABLE PLATES

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

LIEBERT VNSA Installation Sheet

LOXONE 12 Channel Amplifier

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Top Commercial / Residential Electrical Requirements *

Extension Cord Safety Policy

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

SECTION LOW VOLTAGE LIGHTING CONTROLS

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

12 Volt 30 Amp Digital Solar Charge Controller

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Installation Instructions

Utility Distribution Systems

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

8146/5 Series Breaker Panelboards

NEC 2014 Code Changes

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

HOUSING QUALITY STANDARDS (HQS)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

AutoRanging Digital MultiMeter

HARTING Ethernet Cabling 8-poles Overview

mpm DIN CONNECTORS

AMPSEAL* Automotive Plug Connector and Header Assembly

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Waterproof Connectors for Outdoor Use

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Your Guide to. Electrical Safety

Installation and Operating Instructions (for chargers shown below)

SOLAR POWER - THE NEW WAY TO RV!

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Product and functional description

ST Series POWER SUPPLIES USER INSTRUCTIONS

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Parallel Circuits. Objectives After studying this chapter, you will be able to answer these questions: 1. How are electrical components connected

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Industrial Control Power Transformers

CompactLogix Power Supplies Specifications

Power surges can also be generated by equipment in your facility such as:

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Phase-Adaptive Power Module

HARTING Ethernet Cabling 4-poles Overview

Transcription:

Section Index PEOPLE PROTECTIVE DEVICES Ground ault Receptacle Product eatures...1 Ground ault Hospital Grade Receptacle Product eatures...2 Ground ault Cord Sets, Plugs & In-Line GCI Product eatures...3 Receptacles...4 Circuit Watch Ground ault Devices...5 Ground ault Receptacle Technical Specifications...6

Product eatures Ground ault Receptacle Devices Listed to UL Standard 943, Class A & UL 498 Chamfered corner allows for easy ground terminal access Shallow depth allows for easy installation. Both 15 amp and 20 amp GR receptacles have feed through ampacity rating of 20 amps at 125V AC ace and base molded of rugged, impact-resistant thermoplastic material Wide flanged wire pockets easily accept up to #12 Awg wire CSA Certified Large, dual direction test and reset buttons for convenient operation Matching wall plate included with each receptacle Plated corrosion-resistant yoke Deep pocketed wire well to securely hold wire Back & side wiring clamp-type terminals G52IA WHY GROUND AULTS ARE DANGEROUS Electricity normally flows into a tool or appliance through a hot wire and returns through a neutral wire normally grounded. A ground fault occurs when worn or damp insulation or faulty wiring in electrical equipment allows current to leak to ground through an unintended path. If a human is in that path, he can complete the circuit. Shock, injury or electrocution can result, depending on the age and health of the operator, how well-grounded he is, and the path of the current through his body. HOW THE GR RECEPTACLE MINIMIZES GROUND AULT HAZARDS Bryant s GR ground fault receptacle constantly monitors the current flowing through a circuit. When a ground fault current leakage in excess 4-6 milliamperes is detected (a level approaching a potentially hazardous condition), the GR s sensitive electronic circuitry automatically trips a switch, interrupts the circuit and cuts off the power. It acts within 25 milliseconds or less faster than a heartbeat preventing possible injury to a normally healthy person. Ground fault current levels in the range of 4-6 milliamperes will not affect the heart rhythm of a healthy adult. Heart fibrillation generally occurs between 50-100 milliamperes. The ability of the GR to sense low-level ground faults assures optimum protection for people in homes... industrial plants... offices... and hospitals... wherever electricity is used. UL STANDARD 943, THIRD EDITION All Bryant GR s are engineered and manufactured in accordance with UL Standard 943. As of January 1, 2003, the third edition of the standard increased the performance requirements for ground fault circuit interrupters. Bryant ground fault products manufactured after this date conform to these standards. The main changes associated with the third edition are as indicated: Miswiring of a GCI by reversing line-load can cause a lack of GCI protection. When energized, the Bryant GR reset button will pop-out if one tries to reset the GR when miswired. This indicates that power is present, but GR protection is not. Wiring must be corrected before the reset button will properly engage. Transient voltage surges can damage the sensitive electronics associates with all ground fault products. To minimize surge damage, all Bryant GR s are built with protection to test at peak voltage of (2 KV, 1 KA), (4 KV, 2 KA) & (6 KV, 3 KA). Moisture can cause corrosion internal to the ground fault mechanism, especially because of its use in and around wet environments. Bryant GR s feature conformal coated PC boards to resist humidity and corrosion. In today s world, environmental noise is everywhere, from radio communications to cell phones. Bryant GR s are designed with immunity to R of 0.5V over a frequency range of 150 khz to 230 MHz, minimizing negative effects. All Bryant GR s undergo stringent quality review. Each product manufactured is tested, numbered and labeled before ever leaving our factory to assure optimal performance and customer satisfaction. NATIONAL ELECTRICAL CODE REQUIREMENTS OR GROUND AULT CIRCUIT INTERRUPTERS or information regarding the application of ground fault circuit interrupters, consult the following articles of the National Electrical Code: ARTICLE 210 -BRANCH CIRCUITS 210.8 Ground ault Protection for Personnel ARTICLE 527 -TEMPORARY INSTALLATIONS 527.6(A) Ground ault Protection for Personnel ARTICLE 527 -COMMERCIAL GARAGES, REPAIR AND STORAGE 527.6(A) Ground ault Circuit Interrupter Protection for Personnel ARTICLE 517 -HEALTH CARE ACILITIES 517.17 Ground ault Protection ARTICLE 680 - SWIMMING POOL, OUNTAINS AND SIMILAR INSTALLATIONS 680.51(A) Transformers and Ground ault Circuit Interrupters 680.56(A) Ground ault Circuit Interrupter Consult your local electrical authorities for additional information and guidance. 1 Product specifications appearing in the following section are subject to change without notice.

Product eatures Hospital Grade Ground ault Receptacle Devices Brass yoke CSA Certified Both 15 amp and 20 amp G receptacles have an ampacity rating of 20 amps at 125V AC Recessed test and reset buttons to prevent accidental tripping from oversized molded plugs Reinforced contact terminals to assure maximum plug retention Large, combination back & side wiring clamp-type terminals accept up to #12 Awg wire ace and base molded of a rugged impact-resistant thermoplastic material PC Board is conformal coated to resist humidity and corrosion. Hi conductive brushes Plaster-cleaning captive mounting screws Listed to UL Standards 943, Class A & 498 Hospital Grade Large contacts for excellent conductivity and reliable performance Back wired terminations G83WA 2

Product eatures Ground ault Devices Cord Sets, Plugs and In-Line GCI UL Listed Available in surge or ground fault protection Green LED pilot light indicates available power Automatic reset on power failure; manual reset when ground fault occurs SJTW-A cord #14/3 12/3 SJO cord Easy-to-operate sealed key pad Sealed molded plug Bright fault light indicator Heavy-duty molded connector High-impact PVC watertight housing Rugged lexan construction Built in 5±1 MA ground fault current protection UL Listed, CSA Approved High-visibility yellow cord T1254G6 GCI115 High-impact thermoplastic construction Convenient test and reset (silicone cover) protected buttons Center screw mounting available High impact ABS housing UV stabilized 94VO Available in black or high-visibility yellow Provides grounded neutral and open neutral protection Testing instructions on front of device Large neon indicating light UL Listed. Meets UL Standard 943 for portable applications 5±1 MA fault current protection Compact angle design Ultrasonically welded housing 1 piece sealed key pad test & reset buttons Advanced patented electronic design for fast response to ground fault currents CSA Certified 3 NEMA 5-15R portable plug in GCI GP15BY GP153R 3

NEMA 5-15 NEMA 5-20 GR Ground ault Receptacles 2-Pole 3-Wire Grounding 15 Amp 125V; 20 Amp 125V eatures - Specifications RECEPTACLE Bryant Ground ault Receptacles conform to UL Standards 943, Class A and National Electrical Code requirements eed-thru units can be wired to protect additional downstream receptacles on the same circuit Compact shallow design permits flush mount ing in standard 2 1/2 (63.5) deep outlet box Wall Plate included with each receptacle One-piece triple-wipe brass line contacts Heavy zinc-plated steel rustresistant yoke, Hospital Grade has brass yoke ace and base molded of rugged impactresistant thermoplastic material Combination back & side wiring clamp-type terminals accept up to #12 stranded or solid conductors. Both 15 amp and 20 amp GR receptacles have ampacity interrupting rating of 20 amp at 125V AC Meets disconnect speed of 25 milliseconds at operating voltages 102-132 volt range for fault currents of 264ma based on UL formula T=( 20 ) 1.43 Sensitive to fault currents as low as 5ma ± 1ma. rom noload to full-rated load Large 10 mm, 50 joule, 250V rms MOV (metal oxide varistor) Withstand rating of 2000 amperes UL Listed ile #E57705 Guide #KCXS CSA Certified Class 1451 ile #LR65058 Operating temperatures from -35 C to +66 C NOM COMMERCIAL GRADE G52IA G52WA CATALOG NUMBER 15 AMP 125V NEMA 5-15 20 AMP 125V NEMA 5-20 COLOR EED-THRU EED-THRU G52A G53A Brown G52BKA G53BKA Black G52GYA G53GYA Gray G52IA G53IA Ivory G52RA G53RA Red G52WA G53WA White HOSPITAL GRADE CATALOG NUMBER 15 AMP 125V NEMA 5-15 20 AMP 125V NEMA 5-20 COLOR EED-THRU EED-THRU G82A G83A Brown G82GYA G83GYA Gray G82IA G83IA Ivory G82RA G83RA Red G82WA G83WA White BLANK ACE CATALOG NUMBER 20 AMP 125V COLOR DESCRIPTION EED-THRU G53INTA Brown Blank ace Ground ault Interrupter G53INTGRYA Gray Blank ace Ground ault Interrupter G53INTIA Ivory Blank ace Ground ault Interrupter G53INTRA Red Blank ace Ground ault Interrupter G53INTWA White Blank ace Ground ault Interrupter PRODUCT DIMENSIONS ( ) Indicates mm dimensions 1.70 (43.2).32 (8.1) 4.08 (103.6) 2.62 (66.5) 3.81 (96.8) 3.28 (83.3) 2.70 (68.6) G53INTIA 1.30 (33.0) G52A 1.15 (29.2) NOTE: GCI type receptacles should not be used in critical care patient areas or for life support equipment applications due to the possibility of power interruption. 4

Ground ault Devices 15 Amp 125V AC T1254G6 eatures - Specifications QUADPLEX GROUND AULT CORD SET Rugged Lexan construction Green LED pilot light indicates available power 12/3 SJO cord Compact design Nonmetallic, non-conductive box eliminates marred surfaces that often occur with heavy steel boxes UL Listed ile #E57705 Meets OSHA requirements NOM PORTABLE GCI Convenient portable GCI protection Use with power tools, appliances, etc. Meets OSHA jobsite requirements UL Listed and CSA certified IN-LINE GCI CORD SET GCI housing is watertight for outdoor use Rugged, high-impact PVC for long life Easy-to-operate sealed keypad Meets NEC for GCI power at construction sites UL Listed and CSA Certified Provides protection for 2- and 3-wire grounded appliances and tools Bright fault indicator light GROUND AULT PLUG High-impact thermoplastic construction Color-coded terminals Clamp-type terminals Advanced patented electronic design Compact angle design UL Listed ile #E57705 Guide #KCXS CSA Certified Trip response time for ground fault and grounded neutral less than 25ms 3-pin grounding plug, NEMA 5-15P Mechanical trip indicator Requires manual reset after each trip, including loss of power QUADPLEX GROUND AULT CORD SETS CATALOG NUMBER COLOR DESCRIPTION GCI115 T1254G6 Yellow 6 t., 12/3 SJO cord, pilot light, Lexan T1254G25 Yellow 25 t., 12/3 SJO cord, pilot light, Lexan IN-LINE GCI CORD SETS, OUTDOOR RATED GCI115 Yellow/Black 1 1 /2 t., 14/3 SJTW-A cord, trip light, PVC GCI615 Yellow/Black 6 t., 14/3 SJTW-A cord, trip light, PVC GCI2515 Yellow/Black 25 t., 14/3 SJTW-A cord, trip light, PVC GROUND AULT PLUGS, USER ATTACHABLE GP15B Black Compact, 2-pole 3-wire plug, thermoplastic GP15BY Yellow Compact, 2-pole 3-wire plug, thermoplastic PORTABLE 3 OUTLET PLUG IN GCI GP153R GP153R PRODUCT DIMENSIONS ( ) Indicates mm dimensions Portable GCI class A 3 outlet plug-in module with manual set, 2-pole 3-wire, 15 Amp 120V AC 15A. 125V NEMA 15-5P 2.56 (65.0) #14-3 SJTW-A 15A. 125V NEMA 15-5P.93 (23.6).79 (20.1) 1.69 (42.9) 9.00 (228.6) 5.19 (131.8) A (SEE CAT. NO.) 5.50 (139.7) AULT LIGHT 5.83 (148.0) 4.15 (105.4) 1.58 (40.1) GP15BY 3.45 (87.6) 2.02 (51.3) RONT 1.23 (31.2) SIDE GCI115 GP153R GP15B 5

Ground ault Receptacle Technical Specifications Ground ault Receptacle DESCRIPTION Typical Specification Catalog No. G52I Manufacturer s Identification Bryant G52IA Description Straight Blade Duplex GCI Receptacle Type 2-Pole, 3-Wire, Grounding Rating 20A, 125V AC eed through 15A 125V AC ACE CERTIICATION UL Listed, ile E57705, Guide #KCXS Complies with UL Standards 498 and 943 CSA Certified to 22.2 No.144 Meets all 2002 NEC requirements COMPONENTS MATERIALS Cover Thermoplastic Base Thermoplastic Line Contacts Brass Mounting Yoke Plated Steel (Hospital Grade - Brass) Terminal Screws #8-32 Back Wire Clamp Steel Ground Screw Steel (Green) #8-32 Test/Reset Buttons Mounting Screws Thermoplastic Plated Steel PERORMANCE Electrical Mechanical Surge Immunity.......................... Peak voltage 6 KV, peak current 3 KA Trip Level............................... 4-6mA Trip Time............................... 0.025 sec nominal requency.............................. 60Hz Voltage................................. 120V AC +10% - 15% Voltage Range........................... 102-132V AC Abnormal Overvoltage..................... UL943 Terminal Identifications.................... Terminals identified in accordance with UL 943 (Line, Load, Hot & White) Terminal Accommodations.................. #14- #12 AWG Copper Conductor only Product Identifications..................... Ratings are a permanent part of the device Environmental lammability............................. UL 94 V2 Operating Temperatures................... -35 C to 66 C (-30 to 150 ) Maximum Humidity........................ 95% Corrosion Resistance...................... UL 943 Resistance to Environmental Noise........... UL 943 0.5V over a frequency range of 150 khz to 230 MHz Additional G53A (see catalog page -4) G82A (see catalog page -4) PRODUCT DIMENSIONS ( ) Indicates mm dimensions 1.70 (43.2).32 (8.1) G83A (see catalog page -4) 4.08 (103.6) 2.62 (66.5) 3.81 (96.8) 3.28 (83.3) 2.70 (68.6) 1.30 (33.0) 1.15 (29.2) G52A 6 See catalog page -1, -2 for catalog numbers, features, product descriptions and product photograph