Installation Guide. DEVIreg Touch. Electronic Intelligent Timer Thermostat.

Similar documents
Installation Guide. DEVIreg 530. Electronic Thermostat.

DEVIreg 330 (+5 to +45 C)

GB/DAS User Instruction

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Installation Instructions

Drayton Digistat +2RF/+3RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

HERZ-Thermal Actuators

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Article: Version:

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

T0118 T2118 T3118. Instruction Manual

Portable Air Conditioner

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Installation & User Instructions

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

User Manual THR840DUK Digital Thermostat

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

OZW30. Central Unit SYNERGYR

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Duct Humidity Transmitter

oj microline touch thermostats PRODUCT PROGRAMME intelligent thermostat design in three dimensions Floor Heating ELECTRIC Hvac CONTROLS & POWER

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

TIG INVERTER INSTRUCTION MANUAL

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Product and Application Description

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Manual. Solar Fountain Mobile Phone Charger

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

User Manual. Video Doorphone CDV-1020AQ

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

How To Set Up An Inverter

Infrarot-Bewegungsmelder IP44

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Meaco 30L and Meaco 40L dehumidifier instruction manual

MOUNTING AND OPERATING INSTRUCTIONS

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

EBDSPIR-PRM, EBDSPIR-PRM-IP

ACS-30-EU-EMDR-10-MOD

INFRARED QUARTZ WALL HEATER

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Wind Sensor W-RS485 with RS485 Interface

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Danfoss Link Mobile Phone Butler

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Wireless 7 Day Programmable Room Thermostat

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

How To Use A Power Supply On A Powerline 2.2 (Ai)

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

The original heating cable just got better

COLOR VIDEO DOOR PHONE CDV-71BE/D

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Architect/Contractor Information Package

Installation and maintenance instructions. Danfoss Vent

Radiant Temperature Sensor TY7321

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

MAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

IN-OUT Thermometer with Cable Free Sensor and Clock

Single Channel Loop Detector

OPLC Installation Guide

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

2013 Wireless Video Intercom INSTALLATION GUIDE

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Wireless Indoor/ Outdoor Thermometer

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

Power Socket (2 Gang)

Operating Instructions. Room temperature controller

Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING. Manual

PD 100A. Printing data system

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Manual & Technical Documentation V1.1

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Nest Learning Thermostat Installation Guide. Installation step-by-step

Transcription:

Installation Guide DEVIreg Touch Electronic Intelligent Timer Thermostat www.devi.com

Table of Contents 1 Introduction............... 3 1.1 Technical Specifications..... 4 1.2 Safety Instructions........ 7 2 Mounting Instructions......... 8 3 Settings................. 12 3.1 Initial Settings.......... 12 3.2 Forecast.............. 16 3.3 Window Open.......... 18 3.4 Maximum Floor Temperature. 19 4 Symbols................. 23 5 Warranty................. 24 6 Disposal Instruction.......... 24 1 Introduction DEVIreg Touch is an electronic programmable timer thermostat used for controlling electrical floor heating elements. The thermostat is designed for fixed installation only and can be used for both direct heating of the entire room and for comfort heating of the floor. Among others, the thermostat has the following features: A touchscreen display with backlight. An easy-to-follow menu-driven programming and operation. Installation Guide 3

An installation wizard with room/floor type-specific setup. Support for multiple frame systems. Compatible with several 3rd party NTC sensors. Thermostat settings can be specified before installation and imported to the thermostat using a web-generated code, or copied from a thermostat in a similar installation. Smart access to thermostat settings after installation by using a web code interface for easy setup or remote troubleshooting. More information on this product can also be found at: touch.devi.com 1.1 Technical Specifications DEVIreg Touch Operation voltage Standby power consumption Relay: Resistive load Inductive load 220-240 V~, 50/60 Hz Max. 0.40 W Max. 16 A / 3680 W @ 230 V cos φ= 0.3 Max. 1 A 4 Installation Guide

Sensing units NTC 6.8 kohm at 25 C NTC 10 kohm at 25 C NTC 12 kohm at 25 C NTC 15 kohm at 25 C (Default) NTC 33 kohm at 25 C NTC 47 kohm at 25 C Sensing values: (Default NTC 15 K) 0 C 20 C 50 C Control Ambient temperature Frost protection temperature Temperature range 42 kohm 18 kohm 6 kohm PWM (Pulse Wide Modulation) 0 to +30 C 5 C to +9 C (default 5 C) Room temperature: 5-35 C. Floor temperature: 5-45 C. Max. floor: 20-35 C (if unrecoverable seal is broken then up to 45 C). Min. floor: 10-35 C, only with combination of room and floor sensor. Installation Guide 5

Sensor failure monitoring Cable specification max. Ball pressure test temperature Pollution degree Controller type Software class Storage temperature The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or shortcircuited 1x4 mm 2 or 2x2,5 mm 2 75 C 2 (domestic use) 1C A IP class 21-20 C to +65 C Protection class Class II - Dimensions Weight 85 x 85 x 20-24 mm (in-wall depth: 22 mm) 103 g Electrical safety and Electro-Magnetic Compatibility for this product is covered by the compliance with the EN/IEC Standard Automatic electrical controls for household and similar use : EN/IEC 60730-1 (general) EN/IEC 60730-2-9 (thermostat) DEVIreg Touch 6 Installation Guide

1.2 Safety Instructions Make sure the mains supply to the thermostat is turned off before installation. IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35 C. Please also note the following: The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. The thermostat must be connected to a power supply via an all-pole disconnection switch. Always connect the thermostat to continuous power supply. Do not expose the thermostat to moisture, water, dust, and excessive heat. Installation Guide 7

2 Mounting Instructions DEVIreg Touch Please observe the following placement guidelines: Place the thermostat at a suitable height on the wall (typically 80-170cm.). The thermostat should not be placed in wet rooms. Place it in an adjacent room. Always place the thermostat according to local regulation on IP classes. Do not place the thermostat on the inner side of an exterior wall. Always install the thermostat at least 50 cm. from windows and doors. Do not place the thermostat in a way that it will be exposed to direct sunlight. 8 Installation Guide

Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor. Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings. Equally distant and >2cm from two heating cables. The conduit should be flush with the floor surface - countersink the conduit if necessary. Route the conduit to the connection box. The bending radius of the conduit must be min 50mm. Installation Guide 9

Follow the steps below to mount the thermostat: 1. Open the thermostat: DEVIreg Touch Important: Do NOT press on the display screen when removing the front part. Press your fingers under the side of the front part and pull toward you: 2. Connect the thermostat according to the connection diagram. 10 Installation Guide

The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector. Note: Always install the floor sensor in a conduit in the floor. 3. Mount and reassemble the thermostat. Fasten the thermostat to a socket or an exterior wall box by driving the screws through the holes in each side of the thermostat. Put the frame on. Click the display module back in place Important: Do NOT press on the display screen when clicking the display module back in place. Installation Guide 11

Initially main supply the thermostat for 15 hours to fully charge the battery. The current time and day is then kept for 24 hours if mains supply is off. All other settings are stored permanently. 3 Settings 3.1 Initial Settings Initial settings must be specified when the unit is activated for the first time: 1. Use the arrows in the right side of the screen to go to your language, and press to select it. Then press in the upper right corner to confirm. DEVIreg Touch 12 Installation Guide

2. Press the hour numbers and use the < and > arrows to set the hour. Press to confirm. 3. Press the minutes numbers and use the < and > arrows to set the minutes. Press to confirm. Press again to go to the SET DATE screen. 4. Press the day, month and year respectively and set the date using the < and > arrows and pressing to confirm. When the date is correct, press to confirm on the SET DATE screen. 5. If you have already made the installation setup online, press ENTER CODE and go directly to Step 13 now. Otherwise press SETUP WIZARD and go to Step 6. Installation Guide 13

6. On the SETUP information screen, press to start. 7. Use the < and > arrows to select whether only a floor sensor or a combination of room and floor sensors should be used. Press to confirm. Note: A "room only" option may also be available. For details, see the "Maximum Floor Temperature" section. 8. Use the < and > arrows to select the installed floor sensor type. (Measured resistance and corresponding temperature are shown in brackets). Press to confirm. 14 Installation Guide

9. Use the < and > arrows to select the flooring type. Press to confirm. 10. Use the < and > arrows to select the room type. Press to confirm. 11. Use the < and > arrows to select the approximate load of the heating element. If an external relay is used or the installed output is unknown, select the " " option. Press to confirm. Installation Guide 15

12. Use the < and > arrows to select whether the timer should be activated or not. Press to confirm and end the initial thermostat setup. Skip Step 13. 13. Enter your web-generated code. Then press to end the initial thermostat setup. If no check mark ( ) appears, the hexacode is incorrect. 3.2 Forecast The forecast feature is used when you switch between economy temperature and comfort temperature. If forecast is turned on, heating will start so that the requested temperature is reached at the specified time. For example, if your comfort temperature is set to 22 C and the comfort period starts at 6.00 o'clock am, heating will start before 6 o'clock so that your room temperature will be 22 C at 6 o'clock. If forecast is turned off, heating will not start until 6 o'clock and it will take a while to reach a room temperature of 22 C. 16 Installation Guide

The forecast feature also optimises heating stop when switching from comfort temperature to economy temperature. How to turn the forecast feature on and off. 1. Touch the thermostat display to activate it, then press menu. 2. Press SETTINGS in the bottom right corner of the menu. Then press OPTIONS. Installation Guide 17

3. Press FORECAST. Then press ON to optimise heating start/stop or OFF to simply let the heating start/stop at the specified time. Press to confirm. To return to the normal temperature display, press the back arrow in the upper left corner of the screen until you get to the main menu, then press. 3.3 Window Open How to turn "window open detection" on or off 1. Touch the thermostat display to activate it, then press menu. DEVIreg Touch 2. Press SETTINGS in the bottom right corner of the menu. Then press OPTIONS. 18 Installation Guide

3. Press WINDOW OPEN. Then press ON to temporarily turn off heating in case of a sudden temperature drop in the room or OFF to let the thermostat heat during sudden temperature drops in the room. Press to confirm. To return to the normal temperature display, press the back arrow in the upper left corner of the screen until you get to the main menu, then press. 3.4 Maximum Floor Temperature How to set the maximum floor temperature 1. Touch the thermostat display to activate it, then press menu. Installation Guide 19

2. Press SETTINGS in the bottom right corner of the menu. Then press IN- STALLATION and MAN- UAL SETUP. 3. Press MAX. FLOOR. Then use the < and > arrows to set the allowed maximum floor temperature. Press to confirm. To return to the normal temperature display, press the back arrow in the upper left corner of the screen until you get to the main menu, then press. 20 Installation Guide

If you break the small plastic seal on the back of the display module, e.g. using a screwdriver, it will be possible to set the maximum floor temperature up to 45. Furthermore, it will be possible to use only a room sensor. However, this option is not recommendable due to an increased risk of overheating the floor. IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35 C. Note: Please contact the floor supplier before changing the maximum floor temperature and be aware of the following: The floor temperature is measured where the sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top. Floor manufactures often specify the max. temperature on the top surface of the floor. Installation Guide 21

Thermal resistance [m2k/ W] Examples of flooring 0.05 8 mm HDF based laminate 0.10 14 mm beech parquet 0.13 22 mm solid oak plank < 0.17 Max. carpet thickness suitable for floor heating 0.18 22 mm solid fir planks Details > 800 kg/m 3 650-800 kg/m 3 > 800 kg/m 3 acc. to EN 1307 Approximate setting for 25 C floor temperature 28 C 31 C 32 C 34 C 450-650 35 C kg/m 3 22 Installation Guide

4 Symbols The following symbols may appear in the upper left corner of the temperature display: Symbol What it means The thermostat is in manual mode, i.e. the timer function is off. The timer lets you automatically switch between economy and comfort temperatures according to a predefined schedule. An away period has been planned. On the date of departure, the away period starts at 00:00 and the specified away temperature will be maintained 24 hours a day until the date of return at 00:00. At this time the normal temperature settings will resume. An error has occurred. If you press the warning symbol, more information on the error will appear. Installation Guide 23

5 Warranty 5 Y E A R 6 Disposal Instruction 24 Installation Guide

Installation Guide 25

26 Installation Guide

Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: EH@DEVI.com www.devi.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logotype are trademarks of Danfoss A/S. All rights reserved. 08090461 & VIGDU202 Produced by Danfoss 07/2012

DEVIreg Touch Design Frame 140F1064 Intelligent Timer Thermostat Floor / Room Sensor 220-240V~ 50-60Hz~ 0 to +30 C 16A/3680W@230V~ IP 21 Product Documentation DK EL 7224215603 NO EL 5402666 FI SSTL 2600100 Designed in Denmark for Danfoss A/S 5 703466 215135