11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and accessories 443. Chemical products

Similar documents
MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide

Troubleshooting Salt Generators

Anytime from anywhere on earth. and control system with remote access. Pentair. automation

Agricultural and Veterinary Chemicals Code (Listed Chemical Product Home Swimming Pool and Spa Products) Standard 2014

Dr. Kornder. Anlagen- und Messtechnik GmbH & Co. KG. Company Profile

Compact ph Measuring Instruments

The TransCut 300 plasma cutting system - Plasmacutting with liquid working medium

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

PART 1 - INTRODUCTION...

Pool water so pure, it s like taking a swim in a natural spring.

FAQ s & Product & Troubleshooting Guide 37

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

ProMinent Aquatics List Pricing

Taking care of your pool Water treatments A clean and safe pool, all year round.

Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that

Flow switches Series AD/VH

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Dissolved Oxygen Sensors

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

BATTERIES 2010, 2003 by David A. Katz. All rights reserved. Permission for academic use with original copyright retained.

High pressure reactors Where are your limits?

Power consumption (kw)

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

General Purpose ph/orp Sensors

Desalination of Sea Water E7-1

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

BOD measurement. BOD measurements. Respiration. Biological Oxygen Demand. Depletion/Respiration

WATER CHEMISTRY AND POOL WATER BALANCE

The Electrical Control of Chemical Reactions E3-1

Vacuum drying oven for non-flammable solvents

Conductivity and TDS Meters

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

RO Reverse Osmosis equipments

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Morgue refrigeration unit

Clinic Washer-Disinfectors. Washer-Disinfector Line

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

How To Ensure Safety At A Swimming Pool Or Spa

Typical TIG-plasma solutions

Manual. Solar Fountain Mobile Phone Charger


Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

EPOXYMAN (LINE-A-POOL) SWIMMING POOL MAINTENANCE GUIDE 1. INTRODUCTION. 2. CONTROL OF ph 3. SANITATION. Chlorine Donors. 3.

Conlift1, Conlift2, Conlift2 ph+

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

SITRANS F flowmeters SITRANS F M

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Pro Logic Version Diagnostics Manual

Disposing of the product - Protection of the environment:

The Chemical Adjustment Reference Cheat Sheet

Galvanic Parts Per Million Dissolved Oxygen Systems

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

The Determination of an Equilibrium Constant

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Name. Lab 3: ENZYMES. In this lab, you ll investigate some of the properties of enzymes.

Excellent textile care, water and energy savings in one.

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

ENZYME ACTION: TESTING CATALASE ACTIVITY

Compact pressure switch Flameproof enclosure Ex d Model PCA

Serie Idegis Tecno. Piscina Privada / Private Pool

Electronic Flow Switches

Petri Dish Electrolysis Electrolysis Reactions

Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.

Best Practice in Boiler Water Treatment

DETERMINING THE MASS OF A COPPER ATOM

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

High-standard toilet equipment featuring exclusive, timeless design

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers

Automation & Sanitization REPLACEMENT PARTS

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

ph and CONDUCTIVITY ph and conductivity in fountain solution are necessary for plate humidification.

Overheating limit control

A chlorine free swimming pool that s free of odours and taste, soft and gentle on the skin.

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Bringing good things ahead

LC/LCD ranges level controllers

ph and Acidity in Wine and Fruit Juice

Basic Pool & Spa Care

Ospa Water Care Guide for private swimming pools and whirlpools

ph 200 ph-/redox-/temperature Meter Operating instructions

WSD130 SOLDERING STATION

Milwaukee USER MANUAL

Procedure Code A Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

Purification of Floodwater by Electrolysis

Customer application report

MEMBRANE VACUUM MINI PUMPS

Transcription:

432

. Aquasalt Aquasalt 434. Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and accessories 443. Chemical products 433

Aquasalt Aquasalt Bold Aquasalt Sure 434

Aquasalt Pleasure and benefits for our health Aquasalt removes the unpleasant smell from chlorine in your swimming pool and prevents the premature loss of colour of your swimwear. Furthermore, slightly salty water (7 times less salty than sea water) is beneficial for our body, since it provides antiseptic properties for our skin, eyes and nose, and prevents irritations due to chemical products. The AQUASALT electrolysis cells are built using a Titanium alloy coated with different special metals, which act as a catalyst for the production of disinfection substances. The high quality and resistance of these cells gives the AQUASALT systems a longer durability and service life when compared to other products with similar features in the market. The AQUASALT electrolysis cells are built using a Titanium alloy coated with different special metals, which act as a catalyst for the production of disinfection substances. The high quality and resistance of these cells gives the AQUASALT systems a longer durability and service life when compared to other products with similar features in the market. Water Treatment System Using Salt Electrolysis Aquasalt offers a brand new concept on water treatment for our swimming pool. The salt electrolysis provides a high water quality, free of chlorinated chemical products, which may irritate the eyes and the mucosa, as well as dry out the skin. Our simple and robust equipments will help you save time and money during maintenance. Automatic ph Control ph is one of the most important factors in salt electrolysis. Thanks to our ph Control, the ph adjustment and control will be carried out automatically and will be very easy to adjust (standard option for AS Bold systems). It will always keep a value close to 7., which is the optimum level for disinfection. How does Aquasalt work? Our salt electrolysis systems use common salt, which must be added to the swimming pool in a concentration of 3 to 35 g/litre according to the type of water. This salty water will go through a titanium plate, where chlorine and active oxygen are produced. These disinfection elements will keep our swimming pool free of organic matter and pathogens. This operational procedure is fully automatic and safe, and has a maximum voltage of 5 V (similar to common batteries). Less costs and less maintenance Forget about keeping and handling hazardous chemical products in your home: with Aquasalt this will no longer be necessary, thus helping you get a significant saving. Also, chlorinated products are highly oxidant and produce high corrosion levels, which damage the plant room of the swimming pool. Temperature measuring device Redox measuring device ph measuring device ph dosing device Power supply cable Salt electrolysis Safe systems With Aquasalt you will no longer have to add skimmer tablets, thus preventing the risk of children touching them or playing with the rests of granulated chlorine,which usually remain on the borders of the swimming pool. 435

Aquasalt Sure These salt chlorination systems for swimming pools are composed of a control cabinet and an electrolysis cell with titanium coating. Automatic operation: In parallel to the filtration system. Sure programmer: LED indicators with an easy and userfriendly operation. Selfcleaning cell: Polarity is automatically changed in order to reduce scaling on the cell. Connection: 50 mm, glued. Manual adjustment of chlorine production. Automatic lack of salt indication. Flow sensor: Should there be no flow, the system will detect a gas accumulation and stop the operation. 250 30 35 Technical Specifications Supply voltage: 240 Vac 5060 Hz. Cell: Made of titanium with a selfcleaning coating. Cell assembly: Vertical / Horizontal. Service life of the cell: 0.000 h. Salinity range: 3 36 kg/m 3. Min. flow: 5 m 3 /h. Max. flow: 20 m 3 /h. Max. pressure: 2 bar. Temperature: 4 40 ºC. Polarity inversion: Automatic. 50 50 230 800500 80050 800502 800503 800504 800529 Model AS 0 AS 5 AS 20 AS 25 AS 35 Aquasalt 2 ph regulator with peristaltic dosing device 4 L/h.5 bar Cell production g/h 0 5 20 25 35 Max. volume m 3 45 60 90 20 50 ph control Dosing pump 436

Aquasalt Aquasalt ph regulators and dosing pumps ph regulator including a high quality electrode ph, to measure the ph in swimming pools and peristaltic dosing pump. Userfriendly ph Regulator assembled in a watertight box with IP65 degree. Automatic calibration system using its own patterns. Body of the ph electrode made of Epoxy 2 x 50 mm. Measuring range within 0 ph. Supply voltage: 240 Vac 5060 Hz. Peristaltic dosing pump with a flow of L/h. Pressure 3 bar. IP65 Protection. 800529 AQUASALT 2 ph Regulator ph with peristaltic dosing device 4 L/h.5 bar 800525 AQUASALT 2 Peristaltic dosing pump 4 L/h.5 bar 800520 ph Kit for salt chlorination systems AQUASALT 2: 2 plastic clamp ø 50, ph probe, probe holder, reducer /2 3/8, pattern solution ph7 and ph4 80052 REDOX Kit for salt chlorination systems AQUASALT 2: plastic clamp ø 50, ORP REDOX probe, probe holder, pattern solution 465 mv 800523 Temperature Kit for salt chlorination systems AQUASALT 2: Plastic clamp ø 50, temperature probe, probe holder. 437

Aquasalt Bold ph integrated These salt chlorination systems for swimming pools are composed of a control cabinet, an electrolysis cell made of titanium with coating and a ph controller. Automatic operation: In parallel to the filtration system. Bold programmer: Multiline LCDDisplay with control keyboard. It allows configuring the disinfection mode, as well as the lights. Selfcleaning cell: Polarity is automatically changed in order to reduce scaling on the cell. Connection: 50 mm, glued. Covered Mode: The system reduces production when the swimming pool is covered. Flow sensor: Should there be no flow, the system will detect a gas accumulation and stop the operation. Language selection. Manual chlorine regulation. Automatic chlorine regulation. ph control. Automatic lack of salt indication. Automatic excess of salt indicaction. Water temperature indication (optional). 250 50 50 30 35 230 Technical Specifications Supply voltage: 240 Vac 5060 Hz. Cell: Made of titanium with a selfcleaning coating. Cell assembly: Vertical / Horizontal. Service life of the cell: 0.000 h. Salinity range: 3 36 kg/m 3. Min. flow: 5 m 3 /h. Max. flow: 20 m 3 /h. Max. pressure: 2 bar. Temperature: 4 40 ºC. Polarity inversion: Automatic adjustable. PH control: Included. Dosing pump: Not included. 800506 800508 80050 80052 80054 800525 Model AB 0 AB 5 AB 20 AB 25 AB 35 AQUASALT Peristaltic dosing pump 2 4 L/h.5 bar Cell production g/h 0 5 20 25 35 Max. volume m 3 45 60 90 20 50 ph control Dosing pump ORP Control 438

Aquasalt Aquasalt Aquasalt Bold ph + ORP These highperformance salt chlorination systems for swimming pools are composed of a control cabinet and an electrolysis cell with titanium coating. Bold programmer: Multiline LCDDisplay with control keyboard. It allows configuring the disinfection mode. In addition, it allows to control the lights of the swimming pool. Includes a display of the salt percentage in the swimming pool. Selfcleaning cell: Polarity is automatically changed in order to reduce scaling on the cell. Builtin ph controllers to optimise the effect of the chlorine produced. Connection: 50 mm, glued. ORP Control (Redox Potential). In order to adjust the chlorine levels in the swimming pool and prevent an overdosing. Covered Mode: The system reduces production when the swimming pool is covered. Flow sensor: Should there be no flow, the system will detect a gas accumulation and stop the operation. Language selection. Automatic lack of salt indication. Automatic excess of salt indication. Water temperature indication (optional). 250 50 30 35 230 Technical Specifications Supply voltage: 240 Vac 5060 Hz. Cell: Made of titanium with a selfcleaning coating. Cell assembly: Vertical / Horizontal. Service life of the cell: 0.000 h. Salinity range: 3 36 kg/m 3. Min. flow: 5 m 3 /h. Max. flow: 20 m 3 /h. Max. pressure: 2 bar. Temperature: 4 40 ºC. Polarity inversion: Automatic adjustable. PH control: Included. ORP control: Included. Dosing pump: Not included. 50 Model Cell production g/h 80055 80056 80057 80058 80059 800525 ABR 0 ABR 5 ABR 20 ABR 25 ABR 35 AQUASALT Peristaltic dosing 0 5 20 25 35 pump 2 4 L/h.5 bar Max. volume m 3 45 60 90 20 50 ph control Dosing pump ORP control 439

Salt electrolysis demonstration Salt electrolysis demonstration briefcase 2693 Complete briefcase for salt demonstration 268208 Spare demonstration salt chlorinator 3207 Spare stainless steel electrodes 2 32070 Spare aluminium electrodes 2 704502 Beaker 270600 Test tube 440

Aquasalt Salt electrolysis demonstration briefcase 320709 Plastic flask of 50 ml (empty) 320708 6in indicator strips 50 strips 2730 Reagent for chlorine determination, 50 ml 26790 Electronic conductivity analyser. 0 9990 µs 320706 Peroxide indicator strips 00 strips 270403 Demonstration folder for salt chlorinator 44

Spare parts and accessories Spare parts and accessories 800526 ph electrode 800527 800528 Redox electrode Temperature probe 800530 80053 800532 800533 800534 AQUASALT 2 complete cell 0 g/h AQUASALT 2 complete cell 5 g/h AQUASALT 2 complete cell 20 g/h AQUASALT 2 complete cell 25 g/h AQUASALT 2 complete cell 35 g/h 3770 Analysis case for startup. Reading available through easytouse photometer. Analysis parameters. DPD3 chlorine. Cyanuric acid. Alkalinity. Calcium hardness. ph. 442

Chemical products Aquasalt Chemical products for swinnimg pools 3470 347700 3472 3473 34709 3475 34705 34708 34706 34703 34707 3470 3474 Liquid ph reducer for swimming pools Granular ph reducer for swimming pools Antiscaling product for swimming pools Alkalinity reducer for swimming pools Granular dichloro for swimming pools Liquid enzymatic Ultraclear for swimming pools ph increaser for swimming pools in powder form ph increaser for swimming pools in pearl form Clear alkalinity increaser for swimming pools Chlorine stabilizer for swimming pools in powder form Hardness (TH) increaser for swimming pools Flocculant for swimming pools in cartridges Liquid Oxipure for swimming pools kg 2 2 3 5 6 6 7 4 5 5 5 443