Process Control & Instrumentation part IV Control loops

Similar documents
Process Control Primer

A simple method to determine control valve performance and its impacts on control loop performance

REMOTE CONTROL MANUAL

PROCESS CONTROL SYSTEM DESIGN Process Control System Design. LECTURE 6: SIMO and MISO CONTROL

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

HVAC Processes. Lecture 7

How To Control Humidity With A Humidifier

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Operational Overview and Controls Guide

FAST METHODS FOR SLOW LOOPS: TUNE YOUR TEMPERATURE CONTROLS IN 15 MINUTES

saving energy in comfort Factsheet Recair Enthalpy

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Dr. Yeffry Handoko Putra, S.T., M.T

Control of an industrial process using PID control blocks in automation controller

Technical Support Bulletin Nr. 20 Special AC Functions

Frequently Asked Questions

stable response to load disturbances, e.g., an exothermic reaction.

Rev. No. 0 January 5, 2009

Printing and Publishing Energy Savings Guide

CONTROL STRATEGIES FOR HVAC SYSTEMS

Sensing and Control. A Process Control Primer

How Ground/Water Source Heat Pumps Work

Industrial Steam System Process Control Schemes

A Design of a PID Self-Tuning Controller Using LabVIEW

Measurement Products. PID control theory made easy Optimising plant performance with modern process controllers

Microcontroller-based experiments for a control systems course in electrical engineering technology

5 Factors For Finding Your HVAC Comfort Zone

Control System Definition

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

Introduction. Motor Types

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Lambda Tuning the Universal Method for PID Controllers in Process Control


Variable Air Volume - VAV

Impact of Control System Technologies on Industrial Energy Savings

Energy Saving Fact Sheet Air Conditioning

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Best Practices for Controller Tuning

Keywords: Fuzzy Logic, Control, Refrigeration Systems and Electronic Expansion Valves.

Absolute and relative humidity Precise and comfort air-conditioning

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

(Refer Slide Time: 2:03)

Designer. of control solutions NA O7.124A

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Glossary of Heating, Ventilation and Air Conditioning Terms

RF 1. Contents: Connecting diagram. Detailed information:

ENERGY SAVING BY COOPERATIVE OPERATION BETWEEN DISTRICT HEATING AND COOLING PLANT AND BUILDING HVAC SYSTEM

So far we have investigated combinational logic for which the output of the logic devices/circuits depends only on the present state of the inputs.

A Glossary of HVAC Terms:

Fundamentals of HVAC Control Systems

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Switch Mode Power Supply Topologies

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

SR2000 FREQUENCY MONITOR

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

6.2.2 TECHNICAL ARGUMENTS FOR OWN SCADA AND OWN SCADA WITH PID CONTROL.

CHAPTER 11: Flip Flops

USER S INFORMATION MANUAL

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

Advantages of Auto-tuning for Servo-motors

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Creating Efficient HVAC Systems

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

Degree programme in Automation Engineering

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Thermostat with display

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

ngenieros Ingenieros Asociados De Control S.L.

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Air Conditioning Clinic

CGC s Hybrid System Loop Control

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

air conditioners how to choose a cooling system

A Study of Speed Control of PMDC Motor Using Auto-tuning of PID Controller through LabVIEW

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

INTERFERENCE OF SOUND WAVES

Chapter 10. Control Design: Intuition or Analysis?

COMMISSIONING OF HVAC SYSTEMS

Inwall Room Temperature Unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a

Programming Logic controllers

HVAC Systems: Overview

Get the FACTS about SEER and Deliver Better Customer Value

DALI Driver Configurator User Guide

How to choose a heat pump and use it wisely

Transcription:

This chapter aims to bring basic knowledge of control strategies in HVAC systems through a real case study: Temperature control of an open office. Objectives: At the end of this course, you should be able to: Define process control principles and terminology Define basic components of control system Describe the effects of ON/OFF control Describe the effect of proportional control, PI control and PID control. Tune PI controller and understand the need to tune PID controller properly Distinguish the difference between open loop and closed-loop control system Define advantages of cascade control strategy. Hypothesis: Let s consider the open office shown as below. We only consider summer season. This open office is characterized by its sensible loads P S, latent loads P L, air volume flow rate Q SA, indoor temperature T R and Humidity H R. The current system provides a constant volume flow (Q SA ). Humidity is not controlled but constant indoor temperature is required for comfort of occupants whatever loads variations. We also consider well balance ductworks that imply Q SA = Q RA T OUT H OUT Q RA T R H R Q SA H S P S and P L I. How to maintain constant indoor temperature manually: Practical approach Considering hypothesis, can you list the different origins of thermal loads variations: o Internal loads: human bodies release heat and water computers and lighting release heat o external loads: external climate variations position of the sun throughout the day building insulation

Open simulation folder office sans regul and run executable file. Verify and change, if necessary, the initial conditions: number of occupants: 0 outdoor temperature : 32 C outdoor relative humidity: 40% valve opening: 0% What are indoor temperature and moisture value? o The same as outdoor What happens when number of occupants increases up to 30? o Indoor temperature and moisture rise What should you do to bring indoor temperature down to 24 C? Students propose and try different solutions. The objective is to let them highlighting that: They need to observe the temperature They need to open manually the water chiller valve, progressively otherwise temperature drops too quickly. Now it s getting late, let s call it a day! everybody pack up and go back home, but you need to maintain 24 C during the night, and outdoor temperature drop to 26 C. Students realize it is a struggle to adjust temperature. Finally, what are you doing exactly when you re adjusting the temperature? 1. You need crucial information: what is the value of indoor temperature required? 24 C. 2. Simultaneously, you observe the temperature by the means of a thermometer. 3. You compare what you want with what you ve got 4. You think about action to lead in order to open or close the valve 5. Your brain sends a signal to your hand to turn on and off the valve 6. You repeat the sequence 1-2-3-4-5 until what you observe is equal to what you want This is the fundamental principle of control. To control a physical quantity X, you need to: o Measure the value by the means of a sensor o Compare the measured signal variable PV and the Set Point SP o Think about how to act properly to reduce or eliminate the error ε = SP PV o Generate a control signal Y R as a function of ε o Vary the control variable by modulating valve opening What type of devices would you need to install in order to replace Human being? o A sensor or temperature transmitter o A controller o A actuator for command valve opening, such as: solenoid, motor, pneumatic transducer

II. How to maintain constant indoor temperature automatically: The closed-loop 1. Terminology and definitions X is the controlled value PV is the process variable or measurement signal SP is the Set Point ε is the error, ε=sp-pv Corrector is the algorithm that generate Y R : Either PID algorithm or ON/OFF Y R is the control signal, also called CO as Control Output: Either progressive or ON/OFF signal. TCV is the Temperature Control Valve that modulates the Control Variable (which is a physical quantity) Disturbances are all external or internal factors that disturb controlled value X 2. Closed-loop blocks diagram PV T R Q SA SP T OUT Y R Q CW P S and P L SP : Set Point Controller (TCr) ε Y R : Control Output Disturbances: e.g. Internal and external loads P S Control variable: e.g. Chilled Water Flow Q CW + Think Act Generate - X: controlled value e.g. Temperature T R Corrector Actuator or driver e.g. motorized 2-way valve Process e.g. Cooling Coil, Duct, building etc PV : Process Variable Measurement signal Measure & Transmit Sensor + transmitter e.g. here only sensor TEr

In order to simplify blocks diagram, one considers that Act, Generate & Measure functions can merge together to create a single function H. The reduced blocks diagram becomes, At part load conditions: SP remains constant but Disturbances may vary Disturbances: P S H Z Controller (TCr) SP ε Y R + Corrector H - + ± PV Motorized 2-way valve TCV Cooling Coil, Duct, building & sensor TEr At Set Point change: Disturbances remain constant but SP may vary SP ε Y R + Corrector H - PV o H is the process transfer function o H Z is the disturbance transfer function

III. ON/OFF control In order to study the performance of ON/OFF control, we consider the following context: Control of supply air temperature. The required supply air temperature is roughly around 20 C. Label the schematic diagram with:, PV,SP, Y R Encircle the following functions: Think, Act, Generate, Measure and H Open simulation folder office regul ON/OFF and run executable file. Verify and change, if necessary, the initial conditions: number of occupants: 0 outdoor temperature : 32 C outdoor relative humidity: 40% TC S Hysteresis: Set point High: 22 C Set point Low: 19 C Observe the evolution of trends. Change Hysteresis parameters. What do you observe and what conclusions can you draw about ON/OFF control? o The ON/OFF controller switch the output Y R o Y R is a square wave whose frequency depends on hysteresis o The control valve is either totally opened or totally closed o and T R are periodic signals o and T R amplitude and frequency depend on hysteresis o The smaller the hysteresis is, the higher the risk of damaging control valve is

How does ON/OFF control work? Cooling Natural Heating Cooling T R High Set point Low Set point Y R is a square wave whose frequency depends on hysteresis go above High Set point, as a result: Y R is switched ON Valve opens, cooling capacity increases But continue to rise for a short spell, due to process inertia and then decrease. go bellow Low Set point as a result: Y R is switched OFF Valve closes, cooling capacity drops quickly rise quickly, due to high air flow rate bringing in a large amount of warm air Even if this control strategy requires cheap devices such as Thermostat and electrical on/off valve, ON/OFF control does not provide good performance in that case

IV. Industrial PID controllers features o Blocks diagram Control parameters: P, PB or Gain Ti Td AUTO/MANU switch Y RMANU SP ε Y R + Corrector H - PV Tracking switch o PB: Proportional Band = 100/Gain [%] o Gain or P : Proportional Gain o T i : Integral value is a time constant set in second, minutes or repeat/mn o T d : Derivative value is a time constant set in second or minutes o AUTO/MANU control: o Automatic mode: Process is controlled automatically by the controller o Manual mode: you control the process by yourself. o Set Point tracking control: only available in Manual mode, the tracking mode makes Set Point tracking Process Variable in order to eliminate error ε just before moving to Automatic mode. o Direct/Reverse acting control: This mode defines which way Y R varies. o If PV increase when Y R increase, you choose the Reverse acting mode o If PV decrease when Y R increase, you choose the Direct acting mode In the case study, what acting control mode should you choose? Justify your answer. o If Y R then valve opening and Q CW thus cooling capacity, as a result Indoor temperature & PV. You choose Direct acting mode.

V. Effects of P.I.D actions 1. Caution B.T.S FEE [D. Bord lycée St Michel 54] sem 14 Never, never, never start any Controller in Automatic mode without ensuring Controller is properly tuned. In order to highlight dangers of such action, teacher leads experiment using a system of water flow controlled by a controller with bad PI parameters 2. Context for this study In order to study the effects of PID actions, we still consider the control of supply air temperature The required supply air temperature can vary from 17 C to 21 C. This is the controlled range. Q SA SP Y R Q CW P S and P L PV Open simulation folder office regul soufflage and run executable file. Verify and change, if necessary, the initial conditions: number of occupants: 0 outdoor temperature : 32 C outdoor relative humidity: 40% TC S : Manual Internal Set Point tracking control Y R =0% PB=100% I=0 r/mn D=0mn Configure the recorder as shown below

3. Proportional control Adjust manually at 17 C, ensure Set Point = 17 C Move on to automatic mode, and make a Set point step change from 17 to 21 C. What do you observe? ε S o Error remains after transient response: that is steady state error or static error Steady state Do it again twice: PB=50% then PB=20% What do you observe and what conclusions can you draw about P control? PB=50%, Gain=2 Transient response Overshoot [%] o Static error is reduced but overshoot has increased PB=20%, Gain=5 o The system is unstable o Valve open and close periodically. o Temperature oscillates like a sine wave Proportional control: Doesn t provide accurate control Gain reduces static error but influences stability

4. Proportional & Integral control Move on to automatic mode and for these 4 sets of Proportional & Integral parameters: o PB=100%, I=30s and D=0mn o PB=100%, I=3s and D=0mn o PB=100%, I=7,5s and D=0mn o PB=50%, I=7,5s and D=0mn make a Set point step change from 17 C to 21 C. What do you observe and what conclusions can you draw about PI control? Case N 1 Case N 2 Case N 3 Case N 4 o Integral action provides accuracy Proportional & Integral control: Provides accurate control in any cases but a proper combination of PI value is required to avoid instability

5. Proportional, Integral & Derivative control Move on to automatic mode and for these 2 sets of parameters: o PB=50%, I=7,5s and D=0,02mn o PB=50%, I=7,5s and D=0,05mn make a Set Point step change from 17 C to 21 C. Case N 1 Case N 2 Compare these results to the previous one (Part N 4. Case N 4). What do you observe and what conclusions can you draw about PID control? o Derivative action improves stability but overshoot remains high. Proportional, Integral & Derivative control: Derivative control brings stability but a proper combination of PI & D value is required to avoid instability.

VI. How to tune a Controller B.T.S FEE [D. Bord lycée St Michel 54] sem 14 Tuning a controller consists of adjusting PID parameters in order to achieve the required performances: Accuracy : Measure=Set point at steady state Quick response Good stability There are several methods to tune a PID controller. In this chapter, we focus on a model-based method that implies you have the transfer function model of the process. SP Y R Q CW H parameters are: Its static gain K= PV/ Y R Its time constant τ [s] Its time delay T [s] PV H. 1. Graphical method for process modeling Y R Y R H 0.63x PV+PV MIN, PV PV Method procedure: Ensure controller is in manual mode Start on the recorder. Adjust Y R in order to lead PV to low limit of the control range, e.g. around 17 C Wait for steady state Make a Y R step change in order to lead PV to high limit of the control range, e.g. around 21 C Wait for steady state then stop recording. Deduce H parameters T τ

2. Calculation of P & I parameters A PI controller is good enough for such process control. Use these formulas: o Ti = τ o Gain = τπα/(2kt) α depends on the type of response you want: 0,5 > α > 0,2. The smaller the coefficient α is, the faster the response is but the higher overshoot is. Calculate the PI parameters and test the closed-loop performance: o Make set point step change from 17 to 21 C and vice versa o Then enter a 19 C set point, wait for steady state and bring outdoor temperature down from 32 to 26 C What do you observe? Set point step responses 21 C 17 C Disturbance response 19 C We can conclude that when a Controller is properly tuned then: o If Set point step response is good then disturbance response may be good too

VII. Controlling indoor temperature using Open loop control In this context, open loop control means we don t control directly indoor temperature but rather supply air temperature, taking in account outdoor temperature variations. TY is a linear function that converts outdoor temperature into a Set Point sent to TC S : Supply air temperature required _MAX _MIN T OUT_MIN T OUT_MAX Outdoor temperature T OUT Open simulation folder office regul open loop and run executable file. Verify and change, if necessary, the initial conditions: number of occupants: 0 outdoor temperature : 32 C outdoor relative humidity: 40%. Without any calculations, how can you get the values: _MAX, _MIN, T OUT_MIN and T OUT_MAX? o When outdoor temperature T OUT 24 C, you don t need to cool the air thus _MAX =24 C o When outdoor temperature is 32 C, you re supposed to know value that gives T R =24 C, Indeed is one of the considerations required for sizing air handling unit.

Ensure TC S is properly tuned then set TY parameters. Test this open loop strategy changing outdoor temperature from 32 to 26 C. What do you observe? 24 C 23 C T R 20 C o As it s getting cooler outside, supply air temperature varies automatically by the means of TC S, as a result indoor temperature T R remains roughly constant. o This strategy seems to be efficient as regard of outdoor temperature variations. What s happening when number of occupants vary from 0 to 30? 24 C 20 C T R o Indoor temperature T R rises and deviates from its required value when the number of occupants increases, even if remains constant. What conclusions can you draw about open loop control? o This strategy reduces influence of external loads variations is not suitable for internal loads variations.

VIII. Controlling indoor temperature using closed-loop control Open simulation folder office regul reprise and run executable file. Verify and change, if necessary, the initial conditions: Number of occupants: 0 Outdoor temperature : 32 C Outdoor relative humidity: 40%. Using tuning procedure seen previously: o Find H parameters: K, τ, T o Deduce TC R P&I parameters allowing a fast indoor temperature response, without any overshoot. o Test efficiency of parameters making set point step change from 23 to 25 C and vice versa. o What do you observe? Set point step responses T R Response time T RT: 75s

Then enter a 24 C set point and vary number of occupants from 0 to 30 and then outdoor temperature from 32 to 26 C. What can you say about control performance? Compare results to those obtained previously with open loop strategy. Number of occupants increases quickly Outdoor temperature drops quickly T R T R =2 C Response time T RT : 150s o This closed loop strategy is more efficient then open loop control, indeed, indoor temperature remains constant whatever disturbances. o However, in case of external disturbance: o response time is quite long, around 150s o T R =2 C

IX. Upgrading single loop control strategy to cascade control strategy A cascade control strategy includes 2 controllers: o the master controls indoor air temperature T R o the slave controls supply air temperature How does it work? It s 10 o clock, all staff members arrive at the office and start working really hard, then o Master reads indoor temperature and say: hey slave! It s getting warmer can you quickly increase cooling o Slave receives this information from his Master and reply: Ok! I reduce supply air temperature o Master continues observing indoor temperature and commands: Right, stop cooling, it s good now, it s 24 C Suddenly, it s getting cloudy, outdoor temperature drops quickly Slave says to himself: Hey! is decreasing, I have to reduce cooling capacity quickly before indoor temperature decreases too much

Open simulation folder office regul cascade and run executable file. Verify and change, if necessary, the initial conditions: Number of occupants: 0 Outdoor temperature : 32 C Outdoor relative humidity: 40%. Master TC R : Auto Internal Set Point Reverse acting mode PB=8% I=3 r/mn D=0mn Slave TC S : Auto External Set Point Direct acting mode PB=80% I=8 r/mn D=0mn Make set point step change from 23 to 25 and vice versa. Set point step responses T R T RT =60s Then enter a 24 C set point, wait for steady state, and vary number of occupants from 0 to 30 and then outdoor temperature from 32 to 26 C. What can you say about control performance? Compare results to those obtained previously with single closed-loop strategy. T R T R = 1.2 C T RT : 100s o Cascade control strategy reduces Set point and disturbance response time by reacting faster than single closed-loop.