Autosampler Supplies for Agilent GC and HPLC Systems with CTC Autosamplers

Similar documents
Maintaining Your Agilent LC and LC/MS Systems. Our measure is your success.

Sample Vials and Accessories. [ For all ACQUITY UPLC, HPLC, and GC Systems ]

GC-xt. The most flexible GC /GC-MS liquid sample injector

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

GENERAL CHROMATOGRAPHY. Your Essential Resource for Supplies

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Rheodyne Manual Sample Injector Valves

Gas Chromatography Liner Selection Guide

FREE SAMPLE PACK Just ask.

Index Syringes. Hamilton Syringes. Hamilton General Information 142. Hamilton Syringes Syringe Needles

Agilent 1100 Series Well-plate Sampler & Micro Well-plate Sampler. Reference Manual

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Maintaining your Agilent GC and GC/MS Systems

Maintaining Your Agilent 1100 Series HPLC System. Optimize performance and maximize efficiency in your lab. Learn essential HPLC maintenance tips

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Gas Chromatograph GC Consumables. p/n:

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

SCION SQ Series GC-MS

EQuan MAX Getting Connected Field Service Guide

T100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Split / Splitless Injection for Capillary GC

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Analysis of Liquid Samples on the Agilent GC-MS

Syringe Selection Guide

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

ORGANIC SAMPLE PREPARATION

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Vials and Accessories

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Smartline HPLC by design

Valves. Installing a sample loop on a Rheodyne manual sample injection valve in Rohnert Park, CA

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

High Sensitivity MS Determination of Carryover in a New Autosampler Design

TY-FLO Needle Valves

Mass Spectrometry. Fundamental GC-MS. GC Considerations

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Agilent 7697A Headspace Sampler Data Sheet

Installing a Capillary Column into an ECD and a Micro ECD

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

SciTech, sro Praha Ceník Jour Research tisk

Lavender Oil Analysis Using Agilent J&W DB-WAX Ultra Inert Capillary GC Columns

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

ChromQuest 5.0 Chromatography Data System

The Electron Capture Detector (ECD)

How To Test For Contamination In Large Volume Water

Product information CHRONOS 4.1

RENEWABLE BROCHURE. World Class Battery Engineering Flooded & AGM Batteries

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

LC Application Note.

Innovative vs Traditional

Identification of Arson Accelerants by Gas Chromatography

The Theory of HPLC. Gradient HPLC

Clarus 580 Gas Chromatograph

designed to never let you down PerkinElmer Series 200 HPLC Systems

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High pressure reactors Where are your limits?

Protocol: HPLC (amino acids)

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Analysis of Drugs by using the Ultra Inert Inlet Liners with Wool

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

A Complete Solution for Method Linearity in HPLC and UHPLC

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Washing. Sterilising. Filling. Closing. Inspecting. Labelling

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Purification of reaction mixtures using flash chromatography.

Determination of Caffeine in Beverages HPLC-1

HPLC Basics, Equipment, and Troubleshooting

Micro Cryo-Trap Model 971

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

With proper calibration, the upper limit may be extended as needed.

WATERS QUANTITATIVE ANALYSIS solutions

C196-E056F LC-2010HT. Shimadzu High-performance Liquid Chromatograph

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Paper Chromatography: Separation and Identification of Five Metal Cations

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Mitos P-Pump. product datasheet

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Maintaining your Agilent GC and GC/MS Systems Maximize your efficiency. Minimize your downtime. Get the results you need.

Fractional Distillation and Gas Chromatography

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

AxyPrep TM Mag PCR Clean-up Protocol

EnAlgae SOP: Biogas analysis

Transcription:

Autosampler Supplies for Agilent GC and HPLC Systems with CTC Autosamplers Proven reliability that complements Agilent instruments the most reliable in the industry. A wide selection to suit your high-throughput applications. Now conveniently available from one company Agilent. Our measure is your success.

Agilent is your one-stop shop for CTC-approved supplies. In the past, if you used a CTC autosampler with your Agilent GC or LC system, you would have to order supplies separately which meant searching through multiple catalogs and completing multiple purchase orders. Agilent now offers a portfolio of CTC-recommended supplies for your GC PAL, CombiPAL, HTS PAL, and HTC PAL autosamplers. You can now order supplies for your CTC autosampler at the same time you order your Agilent columns and accessories and know that every vial, syringe, and accessory that touches your Agilent analytical systems meets Agilent's uncompromising standards. So you can count on Agilent a company with over 40 years of chromatography experience for the CTC-recommended supplies you need to ensure precise sample handling, optimize system productivity, and get the results you need. HTS and HTC PAL for 1100 and 1200 Series HPLCs GC and CombiPAL for 7890 and 6890 Series GCs CTC Autosamplers feature robotic arms for transporting samples in vessels such as micro, 2, 10, or 20 ml Headspace vials, and well plates. Samples are introduced using specially designed syringes or sample loops. 2

GCCTC CTC Analytics PAL Autosampler Supplies They may be small but they have a BIG effect on your productivity and results. Vials, caps, syringes, and other accessories are the least expensive components of your LC or GC system; however, they can contribute to huge problems such as injector damage, evaporative loss, ghost peaks, and analyte degradation. Agilent understands how critical these parts are to your results which is why all supplies designed for use with CTC autosamplers must meet the most stringent standards and specifications. *Now, Agilent offers you a complete selection of vials, caps, syringes, well plates, and more all approved by CTC to work with their HTS PAL, HTC PAL, GC PAL, and CombiPAL systems. So you can spend less time ordering supplies and more time focusing on method development and analysis. Discover the convenience of ordering your CTC-recommended supplies from Agilent. Visit www.agilent.com/chem/store, or call toll free: 1 800 227 9770, option 1 (in the US and Canada). 3

Choose CombiPAL and GC PAL liquid injection vials and caps for flexibility and high throughput. These micro and 2 ml vials and caps are designed to work seamlessly with CombiPAL and GC PAL magnetic needle guides and bar code readers. They also offer superior maneuverability, so your most complex runs will proceed successfully. The following chart features our most popular part numbers: CombiPAL and GC PAL Liquid Injection Vials and Caps Description Unit Part No. 2 ml vials Crimp top vial, wide opening, clear 100/pk 5181-3375 Crimp top vial, wide opening, amber, write-on spot 100/pk 5181-3376 Crimp top vial, wide opening, clear, write-on spot 1000/cs 5183-4492 Crimp top vial, wide opening, amber, write-on spot 1000/cs 5183-4493 Screw top vial, wide opening, clear 100/pk 5182-0714 Crimp/snap top vial, wide opening, clear 100/pk 5182-0544 2 ml caps Crimp cap, 11 mm magnetic 100/pk 5188-5386 Screw cap, PTFE/silicone septa 100/pk 5182-0720 Snap cap, blue polyethylene, PTFE/silicone septa 100/pk 5182-0541 Micro vials Crimp top vial, 0.8 ml, amber glass, flat bottom 1000/pk 5183-4487 Crimp top vial, 0.1 ml, clear, tapered 500/pk 5180-0844 Crimp top vial, 0.3 ml, clear, round 500/pk 5180-0841 Crimp top vial, 0.7 ml, amber, round 500/pk 5180-0805 Crimp top vial, 0.5 ml, amber, conical 500/pk 5180-0806 Micro caps Crimp caps with PTFE/silicone septa 500/pk 5180-0842 4

GCCTC CombiPAL and GC PAL liquid injection syringes: recommended by CTC to sustain high reproducibility and accuracy. A key feature of CTC's GC PAL and CombiPAL systems is the ability to inject a wide range of sample volumes up to 500 μl for LVI applications. To help you take full advantage of this flexibility, Agilent offers a wide range of C-type syringes from 1.2 μl through 500 μl to accommodate fast and large-volume injections. Each C-type syringe is subjected to stringent quality control procedures to make sure it meets the highest levels of precision and accuracy. CombiPAL and GC PAL Liquid Injection Syringes Volume (μl) Description Unit Gauge Needle Part No. 1.2 Fixed needle 26 26/51/AS G6500-80113 5 Fixed needle 26 26/51/AS G6500-80114 10 Fixed needle 26 26/51/2 G6500-80115 26 26/51/AS G6500-80116 Replacement plunger 10/pk G4200-80105 Fixed needle 23 23S/51/AS 5188-6596 25 Fixed needle 26 26/51/AS G6500-80117 Replacement plunger 10/pk G4200-80104 100 Fixed needle 26 26/51/AS G6500-80118 250 Fixed needle 26 26/51/AS G6500-80119 Replacement plunger 10/pk G4200-80102 500 Fixed needle 26 26/51/AS G6500-80120 Replacement plunger G4200-80106 5

GCCTC CombiPAL headspace supplies help protect the integrity of your data. Our fixed-needle headspace syringes feature a sideport needle for gas flushing, in conformance with strict CTC standards. Use with Agilent s Merlin Microseal to minimize instrument downtime and to prevent lost or compromised data caused by septum leaks and liner contamination. CombiPAL Headspace Syringes Volume (ml) Description Gauge Part No. 1 Fixed needle 23 G6500-80107 Replacement plunger G4200-80101 2.5 Fixed needle 23 G6500-80109 Replacement plunger G4200-80107 5 Fixed needle 26 G6500-80111 Replacement plunger G4200-80108 CTC recommends screw-top vials and caps for the tightest seal and the most reproducible headspace results, and the precision-thread vials and caps listed below are an excellent choice for dependability and ease of use. They are ideal for applications in the environmental, food and beverage, industrial hygiene, drug analysis, and clinical chemistry industries. CombiPAL Headspace Supplies Description Part No. 10 ml, screw top clear vial, 100/pk 5188-5392 20 ml, screw top clear vial, 100/pk 5188-2753 10 ml, screw top amber vial, 100/pk 5188-6538 20 ml, screw top amber vial, 100/pk 5188-6537 UltraClean 18 mm magnetic screw cap with silicone/ptfe septa, 100/pk 5188-2759 Liner, inlet for SPME, deactivated 5188-6471 6

LCCTC HTS and HTC PAL liquid injection vials and caps are designed to withstand the challenges of increased sample throughput. HTS and HTC PAL high-throughput LC injection systems are configured to cope with today's high-throughput LC/MS demands. And Agilent brings you a wide choice of well plates, vials and caps that are engineered to work with these injectors, providing the flexibility you need. The following chart features our most popular part numbers: HTS and HTC PAL Liquid Injection Vials and Caps Description Unit Part No. 2 ml vials Screw top vial, wide opening, clear 100/pk 5182-0714 Screw top vial, polypropylene, with 0.2 ml integrated glass insert 100/pk 5188-5390 Crimp top vial, wide opening, clear 100/pk 5181-3375 Crimp/snap top vial, clear, write-on spot 100/pk 5182-0546 2 ml caps Screw cap, PTFE/silicone septa 100/pk 5182-0720 Screw cap, pre-slit PTFE/silicone septa 100/pk 5183-2076 Crimp cap, silver aluminum, PTFE/silicone septa 100/pk 5182-0552 Snap cap, blue polyethylene, PTFE/silicone septa 100/pk 5182-0541 Micro vials Crimp top vial, 0.8 ml, amber glass, flat bottom 1000/pk 5183-4487 Crimp top vial, 0.1 ml, clear, tapered 500/pk 5180-0844 Crimp top vial, 0.3 ml, clear, round 500/pk 5180-0841 Crimp top vial, 0.7 ml, amber, round 500/pk 5180-0805 Crimp top vial, 0.5 ml, amber, conical 500/pk 5180-0806 Micro caps Crimp caps with PTFE/silicone septa 500/pk 5180-0842 7

HTS and HTC PAL liquid injection X-type syringes last up to 10 times longer than standard syringes. Designed specifically for CTC autosamplers, these X-type syringes feature zero carryover and a long-lasting plunger for applications that demand precision and productivity. They are strongly recommended for high-throughput applications. Agilent offers a wide selection of fixed-needle, 22-gauge, Pointstyle 3 syringes to accommodate a variety of applications. HTS and HTC PAL Liquid Injection Syringes Volume (μl) Description Unit Gauge Needle Part No. 25 X-type Fixed Needle 22 22S/51/3 G4200-80117 Replacement plunger for X-type syringe 3/pk G4200-80112 50 X-type Fixed Needle 22 5188-6485 Replacement plunger for X-type syringe 3/pk 5188-5395 100 X-type Fixed Needle, fast aspiration and eject 22 22/51/3 G4200-80118 X-type Fixed Needle, low dead volume 22 22S/51/3 G4200-80119 Replacement plunger for X-type syringe 3/pk G4200-80111 10 Fixed Needle 22 22S/51/3 G4200-80113 Replacement plunger 10/pk G4200-80103 25 Fixed Needle 22 22S/51/3 G4200-80114 Replacement plunger 10/pk G4200-80104 100 Fixed Needle 22 22/51/3 G4200-80115 Fixed Needle 22 22S/51/3 G4200-80116 Replacement plunger 10/pk G4200-80105 250 Fixed Needle 22 22/51/3 G6500-80102 Replacement plunger 10/pk G4200-80102 500 Fixed Needle 22 22/51/3 G6500-80103 1000 Fixed Needle 22 22/51/3 G6500-80104 2500 Fixed Needle 22 22/51/3 G6500-80105 5000 Fixed Needle 22/51/3 G6500-80106 500 Replacement plunger G4200-80106 1000 Replacement plunger G4200-80101 2500 Replacement plunger G4200-80107 5000 Replacement plunger G4200-80108 8

LCCTC From biological samples to high pressure chromatography, you can trust your results to our HTS and HTC PAL liquid injection valve loops and needle seals. Whether your HTS or HTC PAL autosampler uses the NEW Agilent proprietary Rheodyne high-pressure 600-bar injection valve or Valco Cheminert injection valves, Agilent can help you find a sample loop to meet your most challenging applications including: Rheodyne 600 bar injection valve loops, which include high-pressure Swagelok fittings. Cheminert metal loops, which feature two 1/16 in. stainless steel nuts and two stainless steel ferrules. Cheminert PEEK loops, which include two PEEK nuts and two PEEK ferrules. HTS and HTC PAL Liquid Injection Valve Loops and Needle Seals Description Part No. Description Part No. Rheodyne 600 bar Valve Supplies Stainless Steel Loops: Supplied with Swagelok fittings required for high pressure 5 μl 5188-6486 50 μl 5188-6489 10 μl 5188-6487 100 μl 5188-6490 20 μl 5188-6488 Stator, Rheodyne 600 bar 5188-6491 RheBuild Kit, 600 bar, includes Rotor Seal and 3/32 hex wrench 5188-6492 Needle Seals, Rheodyne valve, 600 bar, 10/pk 5188-6478 Cheminert Valve Supplies PEEK Loops: Include two PEEK nuts and two PEEK ferrules 2 μl 5188-6469 10 μl 5188-6467 5 μl 5188-6470 20 μl 5188-6468 Metal Loops: Include two 1/16 in. stainless steel nuts and two stainless steel ferrules 2 μl 5188-6457 500 μl 5188-6463 10 μl 5188-6458 1000 μl 5188-6464 50 μl 5188-6460 2000 μl 5188-6465 100 μl 5188-6461 5000 μl 5188-6466 250 μl 5188-6462 PEEK Needle Seal, Valco, 22 gauge, 10/pk 5188-6476 Teflon Needle Seal, Valco, 22 gauge, 10/pk 5188-6477 9

Ensure a lifetime of performance with these general CTC autosampler supplies now available through Agilent. Agilent now offers a broad selection of CTC-recommended sampling trays, well plates, and sampling accessories including high-throughput micro vial sample trays and 96- or 384-well plates and closures. So now you can order your CTC supplies from Agilent, along with your columns and other accessories. CTC Autosampler General Supplies Description Part No. Sample tray, 200 vials, 0.7 or 1mL G6500-80100 Sample tray, 98 2 ml or 78 1 ml vials G6500-80101 Sample tray, 32 10 or 20 ml vials G6500-80121 Sample tray, for PAL stack G6500-80122 96 Well plates, 0.5 ml, polypropylene 5042-1386 96 Deep well plates, 1 ml, polypropylene 5042-6454 384 Well plates, 90 μl, polypropylene 5042-1388 Closing mats for 96 well plates, silicone 5042-1389 Well plate foil cutter, max 22 gauge needle 5188-6479 Replacement standard wash kit 5188-6597 Don t forget to order your Agilent-engineered columns along with your CTC supplies. From low-level detection to high-throughput applications, you can rely on Agilent Columns. Together with our CTC-recommended autosampler supplies, Agilent columns help preserve the integrity of your results while helping your system work to its full potential. Agilent J&W Capillary GC Columns: The industry s best low-bleed columns for sensitivity, precision, and performance. A broad range of low-bleed standard and stationary phases. Superior inertness and high temperature limits. Consistent retention, narrow peaks, and improved resolution of closely eluting peaks. In addition, all columns meet Agilent s uncompromising standards, so you can achieve reliable qualitative and quantitative results even for your most challenging compounds. 10

ZORBAX ZORBAX Rapid Resolution High Throughput (RRHT) 1.8 μm columns: The perfect choice for your HTS and HTC PAL high-throughput LC injection systems. Process samples up to 20 times faster than conventional HPLC, when teamed with Agilent s 1200 Series Rapid Resolution LC System. Reduce your analysis time by up to 95% without compromising resolution. Easily scale and reliably transfer conventional LC methods without re-validation. Analyze complex separations on shorter columns. Identify highly sensitive compounds through LC/MS with less co-elution. Recently, we expanded our portfolio to give you over 120 column choices including lengths from 15 mm-150 mm, IDs from 2.1 mm-4.6 mm, and 12 ZORBAX bonded phases, plus bare silica. So you can achieve optimal results under varying temperatures, pressures, and ph ranges. Stock up now, so you never run out of the columns you need. Visit www.agilent.com/chem/store, or call toll free: 1 800 227 9770, option 1 (in the US and Canada). 11

When you choose CTC-recommended supplies from Agilent, you get more than just dependable products. You also get Over 40 years of chromatography expertise. Unmatched technical support on the Web, by phone or in person. A 90-day warranty from the date of shipment. For more information about CTC autosamplers or Agilent products and services: Visit our Web site: www.agilent.com/chem Contact your local Agilent Representative Contact your Agilent Authorized Distributor In the U.S. and Canada, call 1-800-227-9770 Sales Option 1, then 1 Technical Support Option 4, then 2 Stay up to date on the latest Agilent products. Register at www.agilent.com/chem to receive exclusive benefits, such as: Personalized email notifications that reflect your selected interests How-to videos, chromatogram libraries, application notes, and more Free firmware and software updates Faster registration for free e-seminars and other training Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2007 Printed in the U.S.A. June 21, 2007 5989-6837EN